Maintenance disclosures

L · 2026-05-28 Matched by certificate designator
ATA 3350

EMERGENCY LIGHT BATT FAULT ON EICAS. INTEROGATED CMC AND FOUND FAULT CODE 33500001UT1. FOLLOWED FIM TASK 33-50-00-810-801-A00. TROUBLE SHOT TO FWD RH EMERGENCY LIGHT POWER UNIT. RAR FWD RH EMERGENCY LIGHT POWER UNIT IAW AMM 33-50-01. OPS CHECK GOOD.

Source: SDR SIMA20260528002 · FAA SDRS
O · 2025-05-20 Matched by certificate designator
ATA 5210

DOOR L1 HARD TO OPEN OPEN AND CLOSED L1 SEVERAL TIMES IAW AMM SDS 52-11-00, NO FUTHER DEFECTS NOTED

Source: SDR SIMA20250520001 · FAA SDRS
J · 2025-04-23 Matched by certificate designator
ATA 7500

BLEED 1 FAIL IN FLIGHT. LEVEL AT 10000'. CHECKLIST CLEARED THE FAULT. BLEED 1 FAIL AGAIN IN FLIGHT AND CABIN PRESSURE BEGAN TO RISE. LAST NOTED WAS 6000 CABIN ALT. EMERGENCY DECLARED. T/S PER FIM 36-11-00-810-809-A00 RAR RH SIDE TORQUE MOTOR CONTROL FILTER ON #1 ENG SECURED AND TORQUED FWD SERVO LINES. IAW EMB 170 AMM 36-11-06 OPS CHECK GOOD IAW EMB 175AMM 36-11-00

Source: SDR SIMA20250423001 · FAA SDRS
O · 2025-03-11 Matched by certificate designator
ATA 5210

MAIN CABIN DOOR (L1) DIFFICULT TO OPEN FROM THE OUTSIDE AND CLOSE FROM THE INSIDE CYCLED DOOR PER GROUND HANDLING CHECKLIST. NO DEFECTS NOTED AT THIS TIME.

Source: SDR SIMA20250311001 · FAA SDRS