N806DE

EMBRAER SA EMB-550 · 2016 · Fixed-wing multi-engine · 2 engines · 12 seats · Valid Registration

Registered owner: DOUBLE EAGLE AVIATION II LLC, TX (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Executive Flight Services, LLC (E07A)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

30 reports on file, 1995-12-17 – 2019-09-20.

OTHER · 2019-09-20 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 798 hrs · 654 cycles

EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.

Source: SDR XMXR20191211023
OTHER · 2019-09-20 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 798 hrs · 654 cycles

EMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.

Source: SDR XMXR20191211024
Earlier reports · 1995–2018 · 28 reports

2018

OTHER · 2018-05-18 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 455 hrs · 350 cycles

EMERGENCY LIGHTS FLICKER ON AND OFF WITH SYSTEM IN ARM POSITION. REPLACED THE BATTERY PACK.

Source: SDR E07A201805210004
OTHER · 2018-05-18 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 455 hrs · 350 cycles

EMERGENCY LIGHTS FLASH ON AND OFF WHEN SYSTEM IN ARM POSITION. REPLACED THE BATTERY PACK.

Source: SDR E07A201805210003

2003

ENGINE FLAMEOUT; WARNING INDICATION · 2003-03-20 Matched by certificate designator
ATA 7200

Part: ENGINE — FLAMED OUT (NR 1) · airframe 48,005 hrs · 5,623 cycles

AT 133 KNOTS THE NR 1 ENGINE SURGED WITH FLAME-OUT, THE FRONT AND BACK. INSPECTION IN THE FRONT AND BACK, LOOKS OK. DUE TO AD 2002-21-10, THIS IS A GROUP 3 TAKEOFF SURGE AND THE ENGINE WILL BE CHANGED.

Source: SDR DLM11030260
SMOKE/FUMES/ODORS/SPARKS · 2003-03-08 Matched by certificate designator
ATA 5241

Part: SOLENOID — INOPERATIVE (L2 DOOR) · airframe 47,920 hrs · 5,614 cycles

L2 DOOR SMELLS LIKE ELECTRICAL BURNING AND WILL NOT OPERATE ELECTRICALLY. REPLACED LOCK/RELEASE SOLENOID PER M/M. OPS GOOD. NO MORE BURNING SMELL.

Source: SDR DLM11030228

2002

SMOKE/FUMES/ODORS/SPARKS · 2002-11-23 Matched by certificate designator
ATA 2121

Part: FAN — SEIZED (NR 1 PACK) · airframe 46,682 hrs · 5,442 cycles

STRONG ELECTRICAL BURNING ODOR DURING DESCENT, JUST AFTER WINDSHIELD HEAT WAS TURNED ON. CREW DEACTIVATED WINDSHIELD HEAT, TURNED ECON OFF AND ISOLATED THE NR 1 PACK. FUMES DISSAPATED. CREW COULD HEAR MOTOR FAN THAT SOUNDED AS IF IT WAS BINDING. FUMES SEEM STRONGEST AROUND C/B PANEL. FOUND AVIONICS COOLING FAN NR 3 WITH C/B POPPED. REPLACED FAN. FAN OPS NORMAL. C/B REMAINS CLOSED.

Source: SDR DLM11021361
WARNING INDICATION · 2002-11-02 Matched by certificate designator
ATA 3230

Part: ACTUATOR — LEAKING (MLG OVERCENTER) · airframe 46,427 hrs · 5,397 cycles

GEAR FAILED TO RETRACT ON FIRST ATTEMPT. SECOND ATTEMPT SUCCESSFULL. PERFORMED GEAR SWING TO DUPLICATE PROBLEM. SWUNG GEAR 4 TIMES. NO PROBLEMS NOTED. SYSTEM CHECKS GOOD. DURING GEAR SWING, FOUND LT GEAR OVERCENTER LOCK ACTUATOR LEAKING . R & R LT GEAR OVER CENTER LOCK ACTUATOR PER M/M.

Source: SDR DLM11021285
OTHER · 2002-06-19 Matched by certificate designator
ATA 2500

Part: CHILLER — FAILED (AFT GALLEY) · airframe 44,656 hrs · 5,097 cycles

AT CRUISE FLT ATTDS INFORMED US THERE WAS A STRONG ELECTRICAL SMELL IN THE AFT GALLEY CHILLER #8 RED FAIL LIGHT WAS FLASHING. SHUT DOWN CHILLER #8 AND #7. GALLEY POWER WAS ALSO TURNED OFF. DIVERTED TO JFK. SMELL SEEMED TO DISSAPATE. CORR ACTION: FOUND NBR 7 CHILLER FAN GRINDING. CHECKED AREA OF CHILLERS NO EVIDENCE OF ELECT WIRING CHAFFED OR BURNT. CHECKED AFT COOLING FAN FOUND OK #8 CHILLER OPS NORMAL. RPLD #7 CHILLER. PERFORMED OVER WEIGHT LANDING INSPECTION PER M.M.

Source: SDR DLM11020687
NO TEST · 2002-04-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 44,039 hrs · 5,016 cycles

ON PREFLIGHT, EMERGENCY LIGHT TEST FAIL. EMERGENCY LIGHT BATTERY 6 LO MSG ON. REPLACED EMERGENCY LIGHT BATTERY 6 PER M/M. EMERGENCY LIGHT TEST PASS.

Source: SDR DLM11020479

2001

SMOKE/FUMES/ODORS/SPARKS · 2001-08-18 Matched by certificate designator
ATA 2530

Part: OVEN — MALFUNCTIONED (AFT GALLEY) · airframe 41,316 hrs · 4,676 cycles

AFT GALLEY FWD OVEN GIVING OFF BURNING SMELL. REPLACED OVEN.

Source: SDR DLM11011359
OTHER · 2001-06-18 Matched by certificate designator
ATA 3241

Part: TRANSDUCER — FAILED (ANTISKID SYS) · airframe 40,580 hrs · 4,580 cycles

NR 10 TIRE BLOWN ON LANDING. REPLACED NR 10 ANTISKID TRANSDUCER.

Source: SDR DLM11011004

2000

NO TEST · 2000-12-18 Matched by certificate designator
ATA 2611

Part: BATTERY — MISSING (SMOKE DETECTOR) · airframe 38,330 hrs · 4,305 cycles

IR-1330/18DEC/LAX/ 060558 - FRC-261-02208 LAV 4R SMOKE. DETECTOR BATTERY MISSING. CA-REPLACED DETECTOR BATTERY AT 4R. SMOKE DETETOR TESTS NML. MALF-4T0 POS-CN CTL-C12180302 SKILL-02

Source: SDR DLM11002472
WARNING INDICATION · 2000-09-24 Matched by certificate designator
ATA 3610

Part: COMPUTER — MALFUNCTIONED (MANIFOLD FAIL) · airframe 37,448 hrs · 4,209 cycles

AT TOP OF CLIMB GOT NR 2 MANIFOLD FAILURE. SYSTEM RESOLVED ITSELF. FOUND MANIFOLD FAIL COMPUTER BAD. REPLACED SAME.

Source: SDR DLM11001853

1999

FALSE WARNING · 1999-10-27 Matched by certificate designator
ATA 3150

Part: CAWS — INOP (E/E)

ATB AURAL WARNING WITH NO VISUAL CAUSE, UNABLE TO SILENCE HORN. REPLACED CAWS UNIT.

Source: SDR DLM11992378
SMOKE/FUMES/ODORS/SPARKS · 1999-09-01 Matched by certificate designator
ATA 3840

Part: WATER COMP — FAILED (NR 1)

PAX AT 3B NOTICED A HOT WIRE SMELL. THE CREW ALSO NOTICED THE SMELL. LATER F/A AND PASSENGER COMPLAINED OF HEADACHES INSPECTED CEILING FWD CABIN FOR BURNING WIRE CK OK. CHECKED SIDEWALL OF FWD CRAGO COMP FOUND NR 1 WATER COMP BEARING FAILURE. REPLACED NR 1 WATER COMP. CKS GOOD.

Source: SDR DLM11991947
SMOKE/FUMES/ODORS/SPARKS; NO WARNING INDICATION · 1999-07-10 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — MALFUNCTIONED (RT LAVATORY)

THERE WAS A SMALL FIRE OR SMOLDER IN 4R LAV TRASH BIN, IT WAS PUT OUT PROMPTLY BY THE FLIGHT ATTENDANT. NO DAMAGE VISABLE IN CAN. THE SMOKE ALARM DID NOT GO OFF. TESTED SMOKE DETECTOR ON ARRIVAL, CHECKED OK. NO EVIDENCE OF FIRE OR BURNED MATERIAL. TRASH COMPARTMENT AND CONTAINER IN SERVICABLE CONDITION. REPLACED SMOKE DETECTOR PRECAUTIONARY.

Source: SDR DLM11991551
SMOKE/FUMES/ODORS/SPARKS · 1999-06-28 Matched by certificate designator
ATA 2330

Part: MONITOR — FAILED (ROW 40J)

ODOR DETECTED IN AREA OF MONITOR 40J. MONITOR HAD BEEN FLICKERING, NO PICTURE. POWER REMOVED FROM MONITOR, ODOR DISAPPEARED. REPLACED MONITOR AND POWER SUPPLY.

Source: SDR DLM11991462

1998

NO TEST · 1998-12-26 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

FWD CABIN EMERGENCY LIGHT INOP. REMOVED AND REPLACED N01 BATTERY PACK IN THE NR 1 BATTERY POWER SUPPLY, GRD OPS CK OK.

Source: SDR DLM11982631
FLUID LOSS · 1998-05-13 Matched by certificate designator
ATA 3510

Part: OXYGEN LINE — LEAKING (COCKPIT)

IN CRUISE, FOUND CREW 02 BOTTLE EMPTY. FOUND FLEX LINE TO OBSERVER 02 REGULATOR LEAKING BADLY. REPLACED LINE AND REPLACED 02 BOTTLE. LEAK CK GOOD.

Source: SDR DLM11981027

1997

OTHER · 1997-07-19 Matched by certificate designator
ATA 2622

Part: FIRE BOTTLE — LOW PRESS (4L DOOR)

FIRE EXTINGUISHER BOTTLE AT 4L LOW PRESS. REPL BOTTLE.

Source: SDR DLM11971415
OTHER · 1997-05-08 Matched by certificate designator
ATA 5330

Part: SKIN — CORROSION (BS 1937/1959)

THE RT FUSELAGE SKIN SURROUNDING THE FWD AND AFT LAV VACUUM WASTE AIR EXHAUST PORTS WERE FOUND CORRODED ON THE OUTER SURFACE AROUND THE AFT EDGES OF THE PORT CUTOUTS AT FS 1937 AND 1959 RESPECTIVELY. THE CORROSION BLEND OUT ON THE FWD PORT HOLE REQUIRED A MAX DEPTH OF 0.016. THE AFT PORT HOLE REQUIRED THAT THE SKIN BE CUTOUT IN THE DAMAGED AREA. FS 1937 - 0.063 EXT 2024-T3 REPAIR DOUBLER; FS 1956 - 0.071 2024-T3 EXT DOUBLER; GENERAL - 2 INTERNAL FINGER DOUBLERS - SEAL AND TREAT.

Source: SDR DLM11970935
FLT CONT AFFECTED · 1997-01-21 Matched by certificate designator
ATA 2540

Part: FAUCET — LEAKING (LAV M)

WITH A/P ON, WHEN FLIGHT SPOILERS WERE EXTENDED TO FULL, THE AIRCRAFT ROLLED LEFT TOWARD 30 DEGREE BANK. SPOILERS DON'T APPEAR TO EXTEND AT 1/3 AND 2/3 POSITION. AILERON TRIM WAS JAMMED DURING APPROACH, WILL NOT MOVE FROM ZERO POSITION. GROUND SPOILERS DID NOT EXTEND ON LANDING. FOUND ICE BUILDUP IN RIGHT WHEEL WELL IN AREA OF CONTROL CABLES. WATER LEAK FROM LAV -M ABOVE. REPLACED WATER FAUCET IN LAV-M.

Source: SDR DLM11970116

1996

NO TEST · 1996-11-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

EMERGENCY LIGHT SYSTEM FAULTED BATTERY PACK NR 3 AND NR 6.

Source: SDR DLM11962581
OTHER · 1996-11-24 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

EMERGENCY LIGHT SYSTEM FAULTS BATTERY PACK NR 3 AND NR 6.

Source: SDR DLM11962580
OTHER · 1996-05-09 Matched by certificate designator
ATA 7230

Part: COMPRESSOR — FAILED (NR 1 ENGINE)

ON TAKEOFF LOUD BANG LEFT SIDE, VIBRATION, ABORTED T/O. A/C REPORTED SMOKE AND FIRE, FIRED NR 1 AGENT BOTTLE. SHUTDOWN PER CHECKLIST. FOUND COMPRESSOR HAD FAILED, METAL IN TAILPIPE AND BELOW 2.5 BLEED OPENING. MTC IN PROGRESS.

Source: SDR DLM11961115
FALSE WARNING; ENGINE STOPPAGE · 1996-05-09 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 1)

NR 1 ENGINE FAILED DURING T/O RUN. LOUD BANG FROM LEFT SIDE OF A/C HEARD, T/O ABORTED AT 50 KNOTS. A/C REPORTED SMOKE AND FIRE. BLEW NR 1 FIRE BOTTLE AND SHUT DOWN ENGINE. NO EVIDENCE OF FIRE FOUND DURING INSPECTION. CHANGED ENGINE, METAL FOUND IN BLEED VALVE.

Source: SDR DLM11961124
WARNING INDICATION · 1996-04-10 Matched by certificate designator
ATA 2210

Part: AUTOPILOT — INOPERATIVE (NR 1/2)

BOTH A/P INOP, NO CURRENT FAULTS. ACFT RETURNED ATL. PERFORMED RTS ON BOTH FCC, ALL NORMAL.

Source: SDR DLM11960834
ENGINE STOPPAGE · 1996-04-06 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 2 ENGINE)

AFTER TAKEOFF AT 2,600 FT AND 270 KIAS, NR 2 ENGINE FAILED. A/C SHUDDERED, RPM ROLLED BACK AND TEMP WENT TO 754, FIRED EXT AGENT FOR NR 2 ENG. FLIGHT RETURNED TO LAX WHERE MAINTENANCE FOUND METAL IN TAIL PIPE. REPLACED ENGINE AND ROUTED TO SHOP.

Source: SDR DLM11960781

1995

NO TEST · 1995-12-17 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

FAILED EMER LIGHT TEST MSC EMER LIGHT BAT 2 LOW. REPLACED EMER LIGHT BAT 2, OPS CKS OK.

Source: SDR DLM11954721