34 reports on file, 1995-11-10 – 2003-10-19.

SMOKE/FUMES/ODORS/SPARKS · 2003-10-19 Matched by certificate designator
ATA 3100

Part: POWER SUPPLY — BURNED (COCKPIT) · airframe 49,904 hrs · 6,414 cycles

IN FLIGHT SMOKE FROM POSER SUPPLY/ MONITOR ASSY POWER SUPPLY HAS A DISTINCT ODOR OF SMOKE. REPLACED ASSY.

Source: SDR DLM11030937
SMOKE/FUMES/ODORS/SPARKS · 2003-10-18 Matched by certificate designator
ATA 2340

Part: AMPLIFIER — ODOR (PA SYSTEM) · airframe 49,900 hrs · 6,410 cycles

PA FAILED IN FLT. PA AMP NR 1 CB PULLED AND AMP REMOVED DUE TO COMPLAINTS OF ELECTRICAL ODOR. REPLACED PA AMP.

Source: SDR DLM11030934
Earlier reports · 1995–2002 · 32 reports

2002

SMOKE/FUMES/ODORS/SPARKS · 2002-10-06 Matched by certificate designator
ATA 2530

Part: CONTROL PANEL — MALFUNCTIONED (GALLEY OVEN) · airframe 47,486 hrs · 6,032 cycles

OVEN NR 2 BURNING METAL ORDO FROM ELECTRICAL TOUCH PANEL AREA AROUND PANEL HOT C/B PULLED RESET C/B RAN OVEN TO 350 DEGREES FOR 20 MINUTES NO DEFECTS NOTED OK FOR SERVICE

Source: SDR DLM11021173
SMOKE/FUMES/ODORS/SPARKS · 2002-05-15 Matched by certificate designator
ATA 3410

Part: INDICATOR — OVERHEATED (F/O SIDE) · airframe 45,592 hrs · 5,726 cycles

AT CRUISE GOT A VERY STRONG ACRID ELEC SMELL NOTICED THAT F/O IVSI WENT BLANK AND WAS HOT TO TOUCH. PULLED CB AND DIVERTED TO SNN CA FOUND F/OS IVSI TO HAVE BURNT SMELL. WIRING AND CONNECTORINSPECTED NO TROUBLE FOUND. RPLD F/OS IVSI.

Source: SDR DLM11020555
OTHER · 2002-04-28 Matched by certificate designator
ATA 2310

Part: MEGAPHONE — FAILED (AFT) · airframe 45,518 hrs · 5,710 cycles

AFT CABIN MEGAPHONE WILL NOT TEST. REPLACED MEGAPHONE.

Source: SDR DLM11020487

2001

SMOKE/FUMES/ODORS/SPARKS · 2001-08-25 Matched by certificate designator
ATA 2120

Part: ODOR — DETECTED (CABIN) · airframe 42,906 hrs · 5,359 cycles

ODOR OF BURNING RUBBER IN CABIN DURING CRUISE. UNABLE TO LOCATE OR DUPLICATE.

Source: SDR DLM11011405
OTHER · 2001-08-16 Matched by certificate designator
ATA 2210

Part: CONTROL PANEL — FAILED (COCKPIT) · airframe 42,788 hrs · 5,345 cycles

AFTER T/O, A/P & A/T WOULD NOT ENGAGE. REPLACED GCP PER MM.

Source: SDR DLM11011358
SMOKE/FUMES/ODORS/SPARKS · 2001-07-30 Matched by certificate designator
ATA 2121

Part: FAN — NOISY (CABIN) · airframe 42,547 hrs · 5,318 cycles

ORIGINAL DEPARTED NGO. ELECTRICAL FUMES DETECTED ONE HOUR INTO FLIGHT. STRONGEST ODOR IN FORWARD CABIN CLOSE TO THE STAR WARS PANEL DIVERTED TO NARITA. LANDING WEIGHT 425,000LBS. PERFORMED ENTIRE CABIN INSPECTION. FOUND NR 2 RECIRCULATION FAN MAKING EXCESSIVE NOISE DEACTIVATED NR 2 RECIC-FAN AND DEACTIVATED NR 4 RECIRC-FAN DUE TO HIGH SERVICE TIME AS PRECAUTION FWD FAN TO MCO AND PLAC REF MEL 21-22-03 LANDING WEIGHT WITHIN LIMITS NO INSPECTION REQUIRED PER M/M. RMVD AND REPL 4 RECIRC FAN. REPL 2 RECIRC FAN. OPS CK GOOD

Source: SDR DLM11011263
NO TEST · 2001-06-03 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN) · airframe 41,808 hrs · 5,228 cycles

EMERGENCY LIGHT BATTERY 2 LOW MESSAGE IN COCKPIT DURING TEST. REPLACED BATTERY PACK.

Source: SDR DLM11010900
FLT CONT AFFECTED · 2001-05-05 Matched by certificate designator
ATA 2760

Part: CONTROL CABLE — ICED (RT SPOILER) · airframe 41,420 hrs · 5,185 cycles

ON DESCENT WHILE ATTEMPING TO DEPLOY SPOILERS NO SPOILERS DEPLOYED ON RIGHT SIDE. ALSO DID NOT GET RIGHT SPOILERS ON GROUND AND WHEN PLACING FLAPS TO 15 DEGREES GOT ROLLING MOMENT AND FLAP ASYMMTRY LIGHT D305007004. FOUND LARGE AMOUNT OF ICE BUILDUP IN RIGHT FORWARD SECTION OF THE RIGHT WHEEL WELL CAUSING SPOILER CABLE OPERATION RESTRICTION. REMOVED ALL ICE VISUALLY CHECKED AND PERFORMED SATISFACTORY OPERATIONAL CHECK OF ALL FLIGHT CONTROLS PER M/M. CLOSED OFF WATER SHUTOFF VALVE LAV M - C/W SERVICE BULLETIN MD11-53-064.

Source: SDR DLM11010715
SMOKE/FUMES/ODORS/SPARKS · 2001-04-02 Matched by certificate designator
ATA 2530

Part: COMPRESSOR — OVERHEATED (GALLEY CHILLER) · airframe 41,065 hrs · 5,128 cycles

PRIOR TO DEPARTURE FWD GALLEY CHILLER COMPRESSOR MAKING VERY LOUD NOISE AND GETTING WARM HOT / SMOKE - REPLACED CHILLER.

Source: SDR DLM11010549
PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2001-03-12 Matched by certificate designator
ATA 2210

Part: FUEL CONTROL — FAILED (AUTOPILOT) · airframe 40,816 hrs · 5,098 cycles

ON TAKE OFF AFTER PROF SELECTED AT 1000FT AGL AUTO THROTTLES RETARDED THROTTLES 1 AND 3 - REPLACED FCC 1

Source: SDR DLM11010410
INADEQUATE Q C · 2001-02-21 Matched by certificate designator
ATA 5210

Part: HANDLE — MISLOCATED (L-1 DOOR) · airframe 40,549 hrs · 5,070 cycles

L1 DOOR OPEN CONTROL HANDLE FOUND WITH INSUFFUCIENT CLEARANCE TO CREW REST MODULE. MODIFIED STRUCTURE PER ERA 388450-14.

Source: SDR DLM11010307
OTHER · 2001-01-05 Matched by certificate designator
ATA 5311

Part: FRAME — CUT (FUSELAGE) · airframe 39,890 hrs · 5,001 cycles

THE FS 1681 FRAME WAS CUT AT LONG 47R AND THE FRAME SECTION FROM FS 47R TO THE FACTORY SPLICE AT 47L. THE FRAME SECTION WAS REMOVED TO ALLOW ACCESS TO UNDERLYING STRUCTURE. THE FRAME WAS REINSTALLED WITH THE FACTORY SPLICE AT L-47L AND AN IDENTICAL SPLICE AT L-47R. THE REPAIR WAS ACCOMPLISHED PER ER/A 379699-14, REV A.

Source: SDR DLM11010043

2000

NO TEST · 2000-11-17 Matched by certificate designator
ATA 3350

Part: BATTERY — FAILED (CABIN) · airframe 39,404 hrs · 4,954 cycles

EMERGENCY LIGHT BATTERY 1 LOW DURING TEST. REPLACED BATTERY.

Source: SDR DLM11002246
NO TEST · 2000-09-10 Matched by certificate designator
ATA 3510

Part: LATCH — FAILED (OXYGEN DOOR) · airframe 38,606 hrs · 4,875 cycles

FIRST CLASS RT CTR STU SEAT OXYGEN DOOR DID NOT OPEN ON TEST. RESET LATCH MECHANISM ON FWD CABIN RIGHT CENTER ATTENDANT SEAT OXYGEN DOOR. CHECKS GOOD PER AMM 35-21-07-5.

Source: SDR DLM11001767
NO TEST · 2000-09-10 Matched by certificate designator
ATA 3510

Part: LATCH — STUCK (OXYGEN DOOR) · airframe 38,606 hrs · 4,875 cycles

L-2 STU SEAT OXYGEN DOOR DID NOT OPEN ON TEST. REPLACED LATCH MECHANISM ON L-2 FWD FLIGHT ATTENDANT SEAT OXYGEN DOOR. CHECKS GOOD PER AMM 35-21-07-5.

Source: SDR DLM11001768
WARNING INDICATION · 2000-08-25 Matched by certificate designator
ATA 7830

Part: SWITCH — OUT OF ADJ (NR 3 ENGINE) · airframe 38,385 hrs · 4,849 cycles

NR 3 U/L ILLUMINATED AIRBORNE STAYED ON UNTIL DESCENT FOR LANDING, EXTINGUISHED LAST 15 MIN OF FLIGHT. ADJUSTED STOW SWITCHES.

Source: SDR DLM11001649
WARNING INDICATION · 2000-08-13 Matched by certificate designator
ATA 7314

Part: CONNECTOR — DAMAGED (FUEL TANK) · airframe 38,208 hrs · 4,826 cycles

AIRCRAFT ARRIVED WITH MCO NR 007341002 TAIL LEFT PUMP OFF LIGHT ILLUMINATED IN FLIGHT (TRANSFER PUMP. FOUND RECEPTACLE IN PUMP HOUSING WITH BURNED PINS AND WIRING. THE RECEPTACLE SMELLED OF FUEL BUT NO EVIDENCE OF A FUEL LEAK WAS NOTED. REPLACED HOUSING P/N 60-845-2M, COMPANY P/N 280001331, S/N OFF: 3143A, S/N ON: 5043A.

Source: SDR DLM11001558
FLUID LOSS; WARNING INDICATION · 2000-07-12 Matched by certificate designator
ATA 7261

Part: ENGINE — LEAKING (NR 1) · airframe 37,719 hrs · 4,773 cycles

AIR TURNBACK, NR 1 ENG OIL QTY DROPPED TO 9 ON T/O ATL. REPLACED ENGINE FOR INTERNAL OIL LEAK.

Source: SDR DLM11001325
OVER TEMP; SMOKE/FUMES/ODORS/SPARKS · 2000-07-11 Matched by certificate designator
ATA 2121

Part: FAN — OVERHEATED (AIR DISTRIBUTION) · airframe 37,695 hrs · 4,770 cycles

ELECTRICAL SMELL IN FRONT OF TOURIST SECTION TO BUSINESS GALLEY, STRONGER ON RIGHT SIDE. SMELL DISSIPATED WHEN CABIN BUS SWTCHED OFF. INSPECTED SIDEWALL LIGHTING CEILING AREA AND GALLEY. ALSO, CHECKED CARGO COMP, ALL OK. HOWEVER AT CEILING AREA FOUND NR 2 REC, FAN OVERHEATED. REPLACED FAN.

Source: SDR DLM11001315
NO TEST · 2000-06-30 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — FAILED (CABIN) · airframe 37,513 hrs · 4,750 cycles

ON PREFLIGHT, EMERGENCY LIGHT TEST FAILED. REPLACED NR 5 POWER SUPPLY

Source: SDR DLM11001240
NO TEST · 2000-05-16 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (COCKPIT) · airframe 36,789 hrs · 4,675 cycles

EMERGENCY LIGHTS COCKPIT TEST, FAILS BATTERY 2 LOW. REPLACED U1-206 BATTERY.

Source: SDR DLM11000964

1999

PARTIAL RPM/PWR LOSS; WARNING INDICATION · 1999-12-08 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 3)

NR 3 ENG SURGE ON T/O ROLL. T/O ABORTED. MTC FOUND METAL EQUIP SWAP WITH ACFT 803, ACFT 807 NR 3 ENG CHANGE.

Source: SDR DLM11992687
FLUID LOSS · 1999-07-17 Matched by certificate designator
ATA 3810

Part: DRAIN VALVE — LEAKING (POTABLE WATER)

POTABLE WATER SUPPLY DECREASE FROM FULL TO EMPTY IN 4 HOURS. FOUND RT ELECT DRAIN VALVE LEAKING INTERNALLY. CAPPED LINE AND VALVE. CLEARED WATER AND ICE OUT OF AFT STAB COMP, DEFERRED REPLACEMENT OF VALVE.

Source: SDR DLM11991605
NO TEST · 1999-06-14 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

EMERGENCY LIGHTS TEST SHOWS BAT 2. ALL LIGHT ILLUMINATED. REMOVED AND REPLACED NR 2 BATTERY PACK. EMERGENCY LIGHTS TEST PASS. ALL LIGHTS ILLUMINATED.

Source: SDR DLM11991347
NO TEST · 1999-06-14 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

DURING EMERGENCY LIGHT TEST, GOT NR 2 BAT LOW MESSAGE.

Source: SDR DLM11991346

1998

NO TEST · 1998-02-26 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

EMERGENCY FLASHLIGHT WOULD NOT TEST. REPLACED FLASHLIGHT.

Source: SDR DLM11980485
NO TEST · 1998-01-10 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

BAT 6 LOW LIGHTS DURING EMERGENCY LIGHTS TEST AFT SECTION EMERGENCY FLOOR LIGHTS AND SIGNS INOP. FOUND LT DOOR EMERGENCY LIGHT ASSY SHORTED TO GROUND L2-531. REPLACED LIGHT ASSY, OPN NORMAL.

Source: SDR DLM11980090

1997

OTHER · 1997-04-24 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE)

RT FUSELAGE SKIN SURROUNDING THE FWD AND AFT LAVATORY VACUUM WASTE AIR EXHAUST PORTS WAS FOUND CORRODED ON THE OUTER SURFACE AROUND THE AFT EDGES OF THE PORT CUTOUTS. THE SUBJECT SKIN IS MADE FROM 0.068 2024-T3 AL CLAD MATERIAL WITH A LOCAL 0.060 THICKNESS. REPAIR WITH 0.071 2024-T3 CLAD DOUBLER; TWO INTERNAL FINGER DOUBLERS.

Source: SDR DLM11970795
NO TEST · 1997-03-03 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

FLASHLIGHT AT 4R INOP. REPLACED BATT AND STRAP, OPS OK.

Source: SDR DLM11970389

1995

NO TEST · 1995-11-21 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (CABIN)

FLT ATTENDANT CREW REST AND L2 RED EMERGENCY LT INOP. REPLACED BULB, OPN OK.

Source: SDR DLM11954452
NO TEST · 1995-11-21 Matched by certificate designator
ATA 3350

Part: BULB — FAILED (CABIN)

FLOOR TRACK EELS INOP, SEAT 35 AND 42 LEFT, 45 AND 39 RT. RELAMPED, OPN CKS OK.

Source: SDR DLM11954447
SMOKE/FUMES/ODORS/SPARKS · 1995-11-10 Matched by certificate designator
ATA 7261

Part: OIL SEAL — FAILED (NR 3 ENGINE)

AIR TURNBACK, OIL SMELL IN CABIN CAUSED BY NR 3 ENG. LOCKED OUT PRESSURE REGULATOR VALVE FWD TO MC OPER MEL 36-12-01. REPLACED COALESCER BAG, REPLACED NR 3 ENG PER ROUTINE CARD DECK, OPERATION NORMAL.

Source: SDR DLM11954335