Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

21 reports on file, 1995-02-26 – 2003-04-28.

OTHER · 2003-04-28 Matched by certificate designator
ATA 5210

Part: HANDLE — STUCK (DOOR ASSIST) · airframe 46,375 hrs · 6,512 cycles

DOOR 1L WAS ACTUATED BY THE EXTERIOR EMERGENCY HANDLE, DOOR ASSIST BOTTLE BLEW AND HANDLE STUCK IN EMERGENCY POSITION. DOOR WOULD NOT OPEN OR CLOSE ELECTRICALLY. RESET HANDLE AND RESERVICED ASSIST BOTTLE, OPS NORMAL.

Source: SDR DLM11030396
Earlier reports · 1995–2002 · 20 reports

2002

PARTIAL RPM/PWR LOSS · 2002-05-21 Matched by certificate designator
ATA 7200

Part: ENGINE — STALLED (NR 3) · airframe 42,250 hrs · 5,765 cycles

NR 3 ENG STALLED ON T/O ROLL AT 30 KNOTS. REMOVED AND REPLACED NR 3 ENG PER ROUTINE CARD DECK.

Source: SDR DLM11020575
NO TEST · 2002-03-04 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 41,354 hrs · 5,592 cycles

EMERGENCY FLASHLIGHT AT 4R INBOARD BATTERY LOW. REMOVED AND REPLACED FLASHLIGHT AND BATTERY, OPS NORMAL.

Source: SDR DLM11020256
WARNING INDICATION · 2002-01-11 Matched by certificate designator
ATA 3244

Part: TIRE — FLAT (RT MLG) · airframe 40,856 hrs · 5,488 cycles

TIRE FAIL EICAS MESSAGE DURING CLIMB. TIRE PRESSURE ON RIGHT MAIN OUTSIDE AFT TIRE ZERO. TEMP INDICATIONS NORMAL. FOUND NR 8 TIRE AT 0 PSI. REPLACED NR 8 WHEEL ASSY. ALSO REPLACED NR 7 WHEEL ASSY PRECAUTIONARY.

Source: SDR DLM11020036

2001

WARNING INDICATION · 2001-11-07 Matched by certificate designator
ATA 3233

Part: ACTUATOR — BENT (CENTER GEAR) · airframe 40,181 hrs · 5,366 cycles

ATB DUE TO CENTER GEAR WILL NOT RETRACT. FOUND CENTER GEAR RETRACT ACTUATOR BENT. REPLACING SAME.

Source: SDR DLM11011773
FLUID LOSS; WARNING INDICATION · 2001-09-18 Matched by certificate designator
ATA 7920

Part: ADAPTER — BROKEN (NR 3 ENGINE) · airframe 39,734 hrs · 5,300 cycles

OIL QTY ON ENG 3 DROPPED RAPIDLY TO 1 QT AFTER ABOUT 20 MINUTES IN FLIGHT . INITIALLY OIL PRESSURE WAS GOOD, SLOWLY DROPPED TO THE BOTTOM OF THE GREEN BAND 90 PSI. THE ENGINE WAS OPERATED AT IDLE UNTIL LANDING WITH THIS OIL PRESSURE. ON DECEL DURING ROLLOUT PRESSURE WENT RED IT WAS THEN SHUT DOWN. FOUND OIL COOLER BYPASS VALVE SERVO OIL RETURN LINE ADAPTER BROKEN. REPLACED AND CKD CHIP DETS, ALL OK. REPLACED MAIN OIL FILTER, NO METAL. RAN ENG T/O POWER, ALL CKS OK.

Source: SDR DLM11011560
OTHER · 2001-07-12 Matched by certificate designator
ATA 2560

Part: BATTERY — DISCHARGED (FLASHLIGHT) · airframe 39,091 hrs · 5,183 cycles

LED ON EMERGENCY FLASHLIGHT AT 4R NOT FLASHING. REPLACED BATTERY LIGHT, OPN CHECKS NORMAL.

Source: SDR DLM11011152
WARNING INDICATION · 2001-05-20 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 38,455 hrs · 5,079 cycles

ON PRE FLT FOUND TEST SWITCH EMERGENCY LIGHT NR 6 BATTERY LOW MESSAGE ON. REMOVED AND REPLACED SEAT 54B LIGHT ASSY AND HARNESS SYSTEM CHK'S NORMAL PER MM, OK FOR SVC.

Source: SDR DLM11010809

2000

WARNING INDICATION · 2000-10-08 Matched by certificate designator
ATA 2621

Part: BOTTLE — DISCHARGED (NR 1 ENGINE) · airframe 35,818 hrs · 4,649 cycles

FOUR HOURS INTO FLIGHT, ENGINE FIRE AGENT LOW LIGHT ENG 1 WARNING CAME ON. REPLACED NR 1 ENGINE NR 1 FIRE BOTTLE. SQUIB NOT FIRED. SUSPECT AGENT LEAKED OUT AS SOME AGENT STILL PRESENT IN BOTTLE.

Source: SDR DLM11001964
OTHER · 2000-08-29 Matched by certificate designator
ATA 2497

Part: WIRE — DAMAGED (GALLEY) · airframe 35,304 hrs · 4,568 cycles

DURING MTC CVG FOUND DAMAGED GALLEY AND EXTERNAL FEEDER WIRE. ALL DAMAGE WAS FOUND UNDER METAL CLAMPS. REPLACED CABLES.

Source: SDR DLM11001668
NO TEST · 2000-07-30 Matched by certificate designator
ATA 3397

Part: WIRE — CHAFED (ROW 30 - 41) · airframe 34,879 hrs · 4,504 cycles

EMERGENCY LIGHTS FROM ROW 30 TO 41 INOP. REPAIRED CHAFED WIRE AT TERMINAL STRIP IN OVERHEAD LIGHTS, TEST OK.

Source: SDR DLM11001433
FALSE WARNING · 2000-01-30 Matched by certificate designator
ATA 2612

Part: SMOKE DETECTOR — MALFUNCTIONED (LAVATORY)

IN CRUISE, LAVATORY SMOKE ALERT ILLUMINATED FOR LAV H. CLOSE VISUAL INSP IN LAV COMPARTMENT SHOWED NO SMOKE, NO HEAT OR EXTINGUISHING AGENT DISCHARGE. PULLED AND RESET LAV H SMOKE DETECTOR CB AND SYS SMOKE DET CB AT 1L. ALERT RETURNED WHEN CBS RESET. VERIFIED NO TRASH COMPARTMENT EXTINGUISHER DISCHARGE AND HEAT DETECTION DECAL NO INDICATION OF HEAT PRESENT. REPLACED LAV H SMOKE DETECTOR PER M/M. OPS CHECKS OK AND ALL INDICATIONS NORMAL.

Source: SDR DLM11000223

1999

SMOKE/FUMES/ODORS/SPARKS · 1999-09-30 Matched by certificate designator
ATA 2520

Part: VIDEO UNIT — FAILED (ROW 13G)

FLIGHT ATTENDENTS REPORTED VIDEO DISPLAY AT SEAT 13G WAS VERY HOT EVEN THOUGH DISPLAY WAS OFF. NOTICEABLE ELECTRICAL SMELL WAS NOTICED BY PASSENGERS THROUGHOUT B ZONE. AT SUGGESTION OF ATL MCC TURNED OFF ADB SWITCH. DISPLAY COOLED AND SMELL DISPAYED. REPLACED DISPLAY UNIT.

Source: SDR DLM11992181
NO TEST · 1999-05-10 Matched by certificate designator
ATA 3350

Part: SOCKET — SHORTED (ROW 44 & 45)

EMERGENCY LIGHTS FAIL TEST BATTERY 5 AND BATTERY 6 LOW. FOUND SHORTED LIGHT SOCKETS AT SEAT 44 AND 45. REPLACED SAME, GROUND TEST OK.

Source: SDR DLM11991037

1998

NO TEST · 1998-08-22 Matched by certificate designator
ATA 3397

Part: WIRE HARNESS — FAILED (CABIN)

EMERGENCY LIGHT AT SEAT 37B INOP. REPLACED LIGHT/HARNESS ASSY.

Source: SDR DLM11981739

1997

FALSE WARNING · 1997-08-21 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — DIRTY (LAVATORY)

LAVATORY SMOKE ALERT 8 PLUS 30 INTO FLIGHT APPEARED TO BE DUE TO PAX USE OF HAIR SPRAY INTO LAV 3L. ALERT MUST BE CLEARED ON GROUND. REPLACED DETECTOR.

Source: SDR DLM11971638
NO TEST · 1997-07-06 Matched by certificate designator
ATA 3397

Part: WIRE — SHORTED (CABIN)

DURING A CHECK OF EMERGENCY TRACK LIGHTING AT THE GATE, A SECTION OF ESCAPE PATH TRACK LIGHTING WAS FOUND INOPERATIVE. IT WAS DETERMINED THAT TWO WIRE RUNS WERE DAMAGED BETWEEN ROWS 38 AND 49 RIGHT AISLE. THESE CABLES WERE REPLACED RETURNING THE SYSTEM TO NORMAL.

Source: SDR DLM11971305
SMOKE/FUMES/ODORS/SPARKS · 1997-04-03 Matched by certificate designator
ATA 2530

Part: WARMING PLATE — FAILED (MID GALLEY)

SMELL OF BURNING PLASTIC/INSULATION IN B/C CENTERLINE WARMING PLATE UPPER UNIT.

Source: SDR DLM11970602

1996

NO TEST · 1996-07-10 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (COCKPIT)

EMERGENCY BATT TEST FAILS, BATT 1 LOW. FOUND F/C FLOOR TRACK SHORTED OUT AND BATT MAKING LOUD NOISE WHEN SELECTED ON. REPLACED BATT AND REPAIRED TRACK.

Source: SDR DLM11961668
NO TEST · 1996-04-07 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

BATTERY 3 LOW MSG ON TEST FOR EMERGENCY LIGHT SYSTEM. REPLACED BATTERY.

Source: SDR DLM11960788

1995

OTHER · 1995-02-26 Matched by certificate designator
ATA 5730

Part: SKIN — WORN (WING LE)

DURING INSPECTION, FOUND WEAR DAMAGE TO WING LEADING EDGE AT THE INTERSECTION OF NR 1 AND NR 2 LEADING EDGE SLATS. REPAIRED PER SRM 57-10-00 PG 63.

Source: SDR DLM11950830