N812DE

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

26 reports on file, 1996-05-18 – 2003-01-11.

WARNING INDICATION · 2003-01-11 Matched by certificate designator
ATA 7320

Part: EEC — MALFUNCTIONED (NR 2 ENGINE) · airframe 32,019 hrs · 4,561 cycles

ON TO ROLL SELECT FADEC ALTN ILLUMINATED AGAIN ABORTED TO APPROXIMATELY 60 KTS MESSAGE OCCURS SHORTLY AFTER TAKEOFF POWER IS SET NORMAL FULL POWER USED ON BOTH TAKEOFFS. REPLACED NR 2 ENGINE EEC.

Source: SDR DLM11030052
Earlier reports · 1996–2002 · 25 reports

2002

OTHER · 2002-04-16 Matched by certificate designator
ATA 5713

Part: STRINGER — CRACKED (WING) · airframe 28,545 hrs · 3,985 cycles

A CRACK WAS FOUND IN AT WS 826.5 STR 34 IN THE LOWER SKIN STRINGER. THE CRACK WAS APPROX 6 INCHES IN LENGTH RUNNING IN THE RADIUS OF THE STRINGER. REPAIRED ER/A 412871-14.

Source: SDR DLM11020450
OTHER · 2002-04-12 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (FUSELAGE) · airframe 28,545 hrs · 3,985 cycles

CORROSION ON FUSELAGE SKIN AT LAVATORY VACUUM WASTE AIR EXHAUST, FS 1937 & 1959, FOUND DURING HMV. CORROSION BLENDED. INSTALLED DOUBLERS PER ER/A 412865-14, REV NEW.

Source: SDR DLM11020428
OTHER · 2002-01-11 Matched by certificate designator
ATA 3240

Part: BRAKE — UNSERVICEABLE (NBR 8 POSITION) · airframe 27,945 hrs · 3,850 cycles

ON T/O ROLL NOTICEABLE PULL TO RIGHT. DURING CLIMBOUT CHECKED BRAKE TEMP NO. 8 READ 280 ALL OTHERS AT 60. 20 MINS INTO CLIMB TEMP BEGAN TO INCREASE RAPIDLY. TEMP DIFF LIGHT ALSO ILLUM MAX TEMP AT 475 DEG.__REMOVED AND REPLACED NBR 8 BRAKE ASSY. BLEED NBR 8 BRAKE DID ANTISKID RTS CHECK GOOD

Source: SDR DLM11020040

2001

SMOKE/FUMES/ODORS/SPARKS; NO WARNING INDICATION · 2001-08-19 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — MALFUNCTIONED (LAVATORY) · airframe 26,380 hrs · 3,597 cycles

LAV F - SMELLED OF CIGARETTE SMOKE BUT NO ALARM. FOUND USED DISCARDED CIGARETTE IN LAV-F WASTE BASKET. NO EVIDENCE OF BURNING GARBAGE. WASTE CONTAINER FIRE BOTTLES CHECK OKAY AND HEAT SENSE INDICATORS ARE NORMAL. AREA UNDER LAV SINK OKAY. REPLACED OVERHEAD SMOKE DETECTOR AND TESTS OKAY. PERFORMED LAV SMOKE TEST FROM FLT ATTN FWD PANEL AND LAV SMOKE TEST OKAY.

Source: SDR DLM11011362
OTHER · 2001-07-12 Matched by certificate designator
ATA 3350

Part: LENS — DAMAGED (CABIN) · airframe 25,967 hrs · 3,532 cycles

PASSENGER SEAT 121B EMERGENCY TRACK FLOOR LIGHT DAMAGED. REPLACED LENS.

Source: SDR DLM11011156
OTHER · 2001-03-10 Matched by certificate designator
ATA 3520

Part: OXYGEN MASK — DEPLOYED (CABIN) · airframe 24,645 hrs · 3,307 cycles

UPON ENGINE SHUT DOWN ALL OVERHEAD MASKS DEPLOYED WITH AIR SYSTEM IN MANUAL AT AC POWER TRANSFER - NO FAULTS FOUND - UNABLE TO DUPLICATE

Source: SDR DLM11010403

2000

OTHER · 2000-12-20 Matched by certificate designator
ATA 7110

Part: COWLING — DAMAGED (NR 1 ENGINE) · airframe 23,761 hrs · 3,156 cycles

ON TAXI IN TO GATE GRU THE RED STOP LGT WAS ON AND THE ACFT CONTINUED TO TAXI FOWARD APPROX 10 METERS CAUSING NBR 1 ENG TO STRIKE THE JETWAY DAMAGING THE NOSE COWL-FLT CANCELED IR-0855/21DEC/GRU/2489770 - 1 ENGINE LIPSKIN DAMAGED AT 1200 OCLOCK POSITION DUE TO CONTACT WITH THE PASSENGER LOAD BRIDGE. DENT MEASURES APROX 14 INCH CIRCUNFERENCIAL. CA-INTERIM REPAIR ACCOMPLISHED AS PER ER/A 379596-14 AND TIME LIMITED AS PER P.S 900-5-1 NBR04. DYE PENETRANT REVEALED NO CRACKS.

Source: SDR DLM11002492
OTHER · 2000-10-10 Matched by certificate designator
ATA 3520

Part: RELAY — FAILED (OXYGEN MASK) · airframe 22,854 hrs · 3,013 cycles

DURING POWER TRANSFER CREW REPORTED A UNCOMMANDED DEPLOYMENT OF THE PASSENGER OXYGEN MASKS. MTC CHECKED SYSTEM VIA M/M AND REPLACED RELAYS R2-253 AND R2-106.

Source: SDR DLM11002039
SMOKE/FUMES/ODORS/SPARKS · 2000-09-23 Matched by certificate designator
ATA 2500

Part: SMOKE — DETECTED (CABIN SEAT) · airframe 22,650 hrs · 2,987 cycles

SEAT 01H CALL LIGHT AND VIDEO INOP. PASSENGER REPORTED BRIEF ELEC SMOKE ODOR. MTC UNABLE TO DUPLICATE OR FIND FAULT WITH SYSTEM OPERATION.

Source: SDR DLM11001846
SMOKE/FUMES/ODORS/SPARKS · 2000-06-24 Matched by certificate designator
ATA 2312

Part: RADIO — ODOR (COCKPIT) · airframe 21,368 hrs · 2,793 cycles

APPROX 90 MIN INTO FLT AT FL370, A STRONG ODOR IN COCKPIT AND COCKPIT DOOR AREA. SATCOM 1 C/B POPPED AND REMAINED OUT FOR DURATION OF FLT. ODOR DISAPATED AFTER 20-25 MINS. REPLACED SATCOM RADIO FREQ UNIT AND SDU-C/B REMAINS IN. NO ODOR NOTED. A/C OK FOR SERVICE

Source: SDR DLM11001204
OTHER · 2000-05-03 Matched by certificate designator
ATA 2560

Part: BATTERY — INOPERATIVE (FLASHLIGHT) · airframe 20,642 hrs · 2,681 cycles

ON TRIP CHECK FOUND 2L I/B EMERGENCY FLASHLIGHT DOES NOT FLASH AT BATTERY INDICATION. REPLACED 2L I/B EMERGENCY FLASHLIGHT BATTERY, NOW IND OK.

Source: SDR DLM11000879
SMOKE/FUMES/ODORS/SPARKS · 2000-02-10 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (GALLEY)

ELEC SMELL IN AFT GALLEY, HEARD LOUD NOISE FROM CHILLER G6. REPLACED CHILLER.

Source: SDR DLM11000282

1999

OTHER · 1999-08-17 Matched by certificate designator
ATA 3520

Part: OXYGEN GEN — DISCHARGED (AFT LAV)

4L AFT LAV MASKS WERE DEPLOYED IN FLIGHT. WHILE CHECKING CONDITION OF O2 GENERATOR, MECHANIC DISCHARGED SAME. GENERATOR OPERATED CORRECTLY AND WAS REPLACED BY MECHANIC.

Source: SDR DLM11991842
SMOKE/FUMES/ODORS/SPARKS · 1999-06-12 Matched by certificate designator
ATA 5240

Part: CIRCUIT BREAKER — TRIPPED (2R DOOR)

FOUND C/B FOR 2R DOOR ELECTRIC MOTOR POPPED, WOULD NOT RESET. FWD TO MCO AND PLACARD.

Source: SDR DLM11991327
WARNING INDICATION · 1999-06-07 Matched by certificate designator
ATA 2910

Part: CONTROL — MALFUNCTIONED (NR 3 ENGINE)

OVERHEAD C/B A-3 RT HYD CONTROL C/B POPPED CANNOT CONTROL ALL RIGHT EDP. REPLACED ENG HYD PUMP CONTROL RT CB AND RELAYS. NR 3 DEPRESS SOLENOID NEEDS CANNON PLUG.

Source: SDR DLM11991285
WARNING INDICATION · 1999-06-06 Matched by certificate designator
ATA 2910

Part: CONTROLLER — FAILED (HYD SYST)

ENG HYD PUMP CONTROL RIGHT POPPED 45 MIN AFTER T/O. UNABLE TO CONTROL R HYD PUMPS IN MANUAL OR AUTO. RETURNED TO ATL. REPLACED HYD SYS CONTROLLER.

Source: SDR DLM11991273
NO TEST · 1999-03-30 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DEFECTIVE (CABIN)

EMERGENCY LIGHT TEST SHOWS LT BATT 6 LOW. FOUND PIN 6 ON CONNECTOR R1-272 MAKING INTERMITTENT CONTACT, ALSO PIN 6 ON CONNECTOR P1-272 MISALIGNED. REPLACED PIN CONTACT NR 6.

Source: SDR DLM11990698

1997

NO TEST · 1997-11-12 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

DURING TEST, BATT 6 LO MESSAGE. REPLACED POWER SUPPLY AND BATTERY PACK. POWER SUPPLY (P/N 60-4411-3) (S/N 1097), BATTERY PACK (P/N 55-1988-1). BATTERY PACK AND POWER SUPPLY COME AS SEPARATE UNITS. REPLACED BOTH PRECAUTIONARY.

Source: SDR DLM11972333
NO TEST · 1997-11-08 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

EMERG LIGHT TEST FAILED. REPLACED BAT 6 AND POWER SUPPLY, TEST OK.

Source: SDR DLM11972295
FALSE WARNING · 1997-03-22 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — FAILED (LAVATORY L)

LAV SMOKE LEVEL 2 ALERT. FOUND LAV-L SMOKE DETECTOR FAILING. FWD TO MCO AND PLACARD PER MEL 26-13-01A, HISTORY NO.

Source: SDR DLM11970537
NO TEST · 1997-02-12 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

EMERGENCY LT BATT 6 LOW ALERT DURING TEST. REPLACED BATTERY, OPS NML.

Source: SDR DLM11970266
NO TEST · 1997-01-01 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — INOPERATIVE (1R LAVATORY)

SMOKE DETECTOR IN 1R LAVATORY TESTED INTERMITTENTLY. REPLACED DETECTOR, CHECKS NORMAL.

Source: SDR DLM11970003

1996

FLAME/FIRE · 1996-08-21 Matched by certificate designator
ATA 2370

Part: VIDEO MULTIPLEX — FAILED (CABIN)

FLAMES SHOT OUT OF VIDEO MULTIPLEX UNIT. FWD TO MCO AND PLAC 25-22-01, SYSTEM DEACTIVATED.

Source: SDR DLM11961938
NO TEST · 1996-06-15 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

BATTERY PACK NR 6 FAILED PWR UP TEST. REPLACED BATTERY PACK, TEST OK.

Source: SDR DLM11961441
SMOKE/FUMES/ODORS/SPARKS · 1996-05-18 Matched by certificate designator
ATA 2530

Part: OVEN — MALFUNCTIONED (AFT GALLEY)

OVEN NR 307 IN AFT GALLEY WOULD NOT TURNED OFF WITH SWITCH. PULLED C/B'S TO ALL TO STOP OVERHEATING. IT WAS GIVING OFF A BURNING ODOR AND VERY HOT. ATL MTC NOTIFIED.

Source: SDR DLM11961210