N82161

EMBRAER S A EMB-505 · 2011 · Fixed-wing multi-engine · 2 engines · 9 seats · Valid Registration

Registered owner: NOBLE LEASING LLC, GA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
FlightWorks, Inc. (A8OA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

3 reports on file, 2014-02-12 – 2018-05-31.

OTHER · 2018-05-31 Matched by certificate designator
ATA 3397

Part: WIRE — CHAFED (CARGO BAY) · airframe 2,346 hrs · 1,787 cycles

THE FLIGHT CREW REPORTED THAT THE AFT BAG/COURTESY LIGHT WENT INOP. MAINTENANCE TROUBLESHOT THE LIGHTING SYSTEM AND FOUND THE WIRING FOR THE BAGGAGE LIGHTS WIRING WAS PINCHED BETWEEN THE REMOVABLE BAGGAGE PANEL AND THE BAGGAGE STRUCTURE, THIS CAUSED THE WIRE TO CHAFE AND EVENTUALLY SHORT TO GROUND. THE WIRING FOR THE LIGHTING CANNOT BE EASILY CHECKED DURING THE INSTALLATION OF BAGGAGE PANELS. THE WIRING WAS REPAIRED AND ROUTED IN A WAY TO PREVENT FURTHER ISSUES. THE AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR 9JLA201807111433
FALSE WARNING · 2015-07-26 Matched by certificate designator
ATA 3260

Part: SENSOR — FAILED (MLG) · airframe 1,326 hrs · 1,016 cycles

CREW RECEIVED WOW FAIL & ANTI-SKID FAIL CAS MSGS AFTER THE GEAR HANDLE WAS PLACED INTO THE DOWN POSITION. DECLARED AN EMERGENCY AND LANDED WITHOUT FURTHER INCIDENT. FOUND THE LT INBD WOW SENSOR TO BE FAULTY. A NEW WOW HARNESS WAS INSTALLED ON THE LT INBD GEAR IAW AMM 32-41-06-400 & 32-45-01-400. OPS CHECKED GOOD.

Source: SDR DJFA20150726001
ELECT. POWER LOSS-50 PC; WARNING INDICATION · 2014-02-12 Matched by certificate designator
ATA 2432

Part: STARTER GEN — FAILED · airframe 978 hrs · 766 cycles

CREW COMPLIED WITH AN EMERGENCY DESCENT DUE TO ELECTRICAL LOSS AFTER BATTERY EXCEEDANCE MESSAGE DISPLAYED. STARTER GENERATOR & GCU WERE REPLACED. PHASE 3 OVERSPEED INSPECTION WAS COMPLIED WITH & NO DEFECTS NOTED. THE ACFT WAS RETURNED TO SERVICE.

Source: SDR DJFA20140212001