N828JB
Registered owner: JETBLUE AIRWAYS CORP, NY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
36 reports on file, 2015-08-07 – 2026-10-26.
Part: OIL SYSTEM — LEAKING (APU) · airframe 48,663 hrs · 16,618 cycles
FLT 69, BOS-FLL. ODOR OF MOLDY DIRTY SOCK ODOR FROM PACK 1. AFTER PACK 1 WAS TURNED OFF THERE NO LONGER WAS AN ODOR . COMPLIED WITH I/N 2017-T015 N IDENTIFIED SOURCE OF ODOR TO APU LEAKS. PERFROMED LEVEL A ECS DECON. PERFROMED ENGINE RUNS, ISSOLATED EACH BLEED SOURCE. CABIN AIR QUALITY CHKD GOOD.
Part: A/C PACK — ODOR (NR 2) · airframe 46,769 hrs · 15,808 cycles
FLT # 2823 FLL- MSY." DIRTY SOCK SMELL DURING TAKE OFF AND CLIMB AS WELL AS APPROACH AND LANDING. PACK 2 SUSPECTED ( PACKS ).; (RESOLVED ON W/O: 1483807 TASKCARD: NR-00004 ) PERFORMED PACK 1 + 2 BURN DECONTAMINATION PER INFO NOTICE 2017-TO15M. R/R RECIRCULATION FILTERS AS PER AMM 21-21-41. RAN BOTH PACKS, NO ODORS PRESENT, APU PLACED ON MEL. MDDR 613195 CLEARED. MX-4 UPDATED PLACARD RMVD.
Part: UNKNOWN — ODOR (CABIN) · airframe 46,713 hrs · 15,785 cycles
FLT # 291 BOS- TPA. " FLIGHT ATTENDANTS SMELLED DIRTY SOCK SMELL ON CLIMB OUT & DESCENT.; COMPLIED W/ INFO NOTICE 2017-T015 STEP 1 AND 2 IDENTIFIED ODOR AS TYPE 1 APU PLACED ON MEL ON ITEM 2. DECONTAMINATION LEVEL WAS ACCOMPLISHED PER AMM 21-00-00-615-802. A/C OK FOPR SVC.
Part: UNKNOWN — ODOR (CABIN) · airframe 46,481 hrs · 156,690 cycles
FLT 1251, HPN-RSW. DIRTY SOCK OR BURNED POPCORN ODOR IN DESCENT BELOW 10000FT,;COMPLIED WITH INFORMATION NOTED 2017-T015 STEPS 1 & 2. IDENTIFIED ODOR AS TYPE 5 PACK 1. REF LP 4628603-2 AND 4628604-1. AIRCRAFT IS OK FOR SERVICE.
Part: A/C PACK — ODOR (NR 1) · airframe 46,394 hrs · 15,662 cycles
FLT 839, JFK-BQN, PASSING 10000FT WE BOTH SMELLED OIL. COMPLIED WITH THE PROCEDURE AND AFTER 3 MINS, TURNED ON THE NR 1 PACK AND OODR CAME BACK. MUSTY ACID ODOR. COMPLIED WITH INFO NOTICE 2017-T015 STEPS 1 & 2 INDENTIFIED ODOR AS A TYPE 5. NO 30 DAY HISTORY. NR 1 PACK WILL BE PLACED ON MEL REF LOG PAGE 4480585 ITEM # 1. ACFT OK FOR SERVICE.
Earlier reports · 2015–2025 · 31 reports
2025
Part: A/C PACK — ODOR (ZONE 100)
FLT#1283, JFK-MCO. F/A REPORT DIRTY SOCK SMELL AND AMMONIA SMELL IN CABIN WHEN PACKS WERE SELECTED ON ( APU SYSTEM).
Part: A/C PACK — CONTAMINATED (ZONE 100) · airframe 44,931 hrs · 15,092 cycles
FLT#698, MCO-LGA. STRONG FUMES ON DECENT NOT DIRTY SOX @ FLIGHT IDLE; PERFORMED ECS DECONTAMINATION 1 PACK BURN IAW AMM 21-00-00-615-802-A, R/R OZONE FILTERS AND HEPA FILTERS, FOLLOWED BY OPS CHECK, RAN ENG 1 THAN ENG 2 NO SMELL PRESET AT THIS TIME, A/C IS OKAY FOR CONT SVC, COMPLIED WITH INFO NOTICE 2017-T015 SECTION B2.
Part: OIL SYSTEM — LEAKING (APU) · airframe 44,890 hrs · 15,077 cycles
FLT#257, BOS-BZN. APU OILY ODOR / DIRTY SOCKS AFTER GATE ARRIVAL MILD ODOR IN FLIGHT DECK STRONG ODOR IN AFT CABIN IN GALLEY; COMPLIED WITH INFO NOTICE 2017-T015L SECTION B ISOLATED FAULT TO TYEP 1 EVIDENCE OF OIL LEAK IN APU INLET AREA PER TSM 05-50-00-810-085-B APU PLACED ON MEL REF LP 4255102 MDDR# 590973 FOR PRECAUTIUONAY R/R BOTH HEPA FILTERS A/C IS OK TO CONT SVC PACK ECS DECONTAMINATION ALSO PERFORMED.
2024
Part: COFFEEMAKER — ODOR (ZONE 200) · airframe 41,066 hrs · 13,605 cycles
FLT#39, FLL-SFO. 'INFLIGHT CREW REPORTED SMELL OF SOMETHING BURNING AROUND GALLEY OFF BUTTON ELIMINATED SMELL ( COFFEE MAKERS ).' (SUPPLEMENTAL INFORMATION TO FOLLOW)
2023
Part: CONTROL UNIT — FAILED (10GG) · airframe 38,398 hrs · 12,546 cycles
FLT#30 SAN-FLL. 'NORMAL BRAKES INOP AUTO BRAKES INOP; FOUND BSCU AT FAULT. REMOVED AND REPLACED BSCU IAW AMM 32-42-34. ALL OPS CHECKS OK. NO FULTS PRESENT. OK FOR SVC.'
Part: NONE — NONE · airframe 36,551 hrs · 11,848 cycles
FLT#48, TPA-LGA.' RAISED LANDING GEAR GOT A L/G DOOR NOT CLOSED AND WENT OUT WITHIN 10 SEC. ECAM SHOWS EVERYTHING UP AND LOCKED. WHEN WE LOWERED THE GEAR GOT ECAM MESSAGE AGAIN FOR ABOUT 2 SEC; REPLACED THE LH MLG DOOR SWIVEL END ASSY THAT IS ATTACHED TO THE END OF THE CABLE CONTROL ASSY. LH MLG DOOR NOW OPENS AND CLOSES NORMALLY AND NO MESSAGES ON ECAM. REF AMM 32-31-38 AND AMM 32-31-11.'
2021
Part: SERVO — FAILED (ELEVATOR SYS) · airframe 30,776 hrs · 9,788 cycles
FLT 400, MSY-BOS. F/CTL ELAC 2 PITCH FAULT. SHORT SHARP BRIEF PITCH JOLT FOLLOWED BY ABOVE ECAM. RESET SUCCESSFUL ; R+R LH INBD ELEVATOR SERVO IAW AMM 27-34-51. OP CHECKED GOOD BUT FAILS ELEVATOR DAMPING TEST. REFER TO DEFECT 3181961 ITEM 2 FOR REPLACEMENT. R+R LH INBD ELEVATOR SERVO AGAIN IAW AMM 27-34-51. OP CHECKS/LEAK CHECKS GOOD. DAMPNING CHECK PASSES. INSTALLED SAME ELAC 2 AND SEC 2 IAW AMM 27-93-34 AND 27-94-34. OP CHECKS GOOD.
Part: SERVO — FAILED (ELEVATOR SYS) · airframe 30,776 hrs · 9,788 cycles
FLT 400, MSY-BOS. F/CTL ELAC 2 PITCH FAULT. SHORT SHARP BRIEF PITCH JOLT FOLLOWED BY ABOVE ECAM. RESET SUCCESSFUL ; R+R LH INBD ELEVATOR SERVO IAW AMM 27-34-51. OP CHECKED GOOD BUT FAILS ELEVATOR DAMPING TEST. REFER TO DEFECT 3181961 ITEM 2 FOR REPLACEMENT. R+R LH INBD ELEVATOR SERVO AGAIN IAW AMM 27-34-51. OP CHECKS/LEAK CHECKS GOOD. DAMPNING CHECK PASSES. INSTALLED SAME ELAC 2 AND SEC 2 IAW AMM 27-93-34 AND 27-94-34. OP CHECKS GOOD.
Part: SERVO — FAILED (ELEVATOR SYS) · airframe 30,776 hrs · 9,788 cycles
FLT 400, MSY-BOS. F/CTL ELAC 2 PITCH FAULT. SHORT SHARP BRIEF PITCH JOLT FOLLOWED BY ABOVE ECAM. RESET SUCCESSFUL ; R+R LH INBD ELEVATOR SERVO IAW AMM 27-34-51. OP CHECKED GOOD BUT FAILS ELEVATOR DAMPING TEST. REFER TO DEFECT 3181961 ITEM 2 FOR REPLACEMENT. R+R LH INBD ELEVATOR SERVO AGAIN IAW AMM 27-34-51. OP CHECKS/LEAK CHECKS GOOD. DAMPNING CHECK PASSES. INSTALLED SAME ELAC 2 AND SEC 2 IAW AMM 27-93-34 AND 27-94-34. OP CHECKS GOOD.
Part: SLIDE — DEFORMED (PAX DOOR) · airframe 30,161 hrs · 9,584 cycles
DURING HEAVY MAINTENANCE, DEFORMATION SLIDE RAFT PASSENGER CREW DOOR 841 AT FWD GALLEY AREA; (REF AEROMAN N/R 2021-156408) R & R ESCAPE SLIDE RAFT DOOR 841 IAW AMM 25-62-44-000-804-A AND AMM 25-62-44-400-803-A AND PERFORMED OPERATIONAL TEST IS OK
Part: SLIDE — DEFORMED (PAX DOOR) · airframe 30,161 hrs · 9,584 cycles
DURING HEAVY MAINTENANCE, DEFORMATION SLIDE RAFT PASSENGER CREW DOOR 831 AT FWD GALLEY AREA; (REF AEROMAN N/R 2021-156409)R & R ESCAPE SLIDE RAFT DOOR 831 IAW AMM 25-62-44-000-012-A AND AMM 25-62-44-400-007-A AND PERFORMED OPERATIONAL TEST IS OK
Part: SLIDE — DEFORMED (PAX DOOR) · airframe 30,161 hrs · 9,584 cycles
DURING HEAVY MAINTENANCE, DEFORMATION SLIDE RAFT PASSENGER CREW DOOR 842 AT AFT GALLEY AREA; (REF AEROMAN N/R 2021-156406) R & R ESCAPE SLIDE RAFT DOOR 842 IAW AMM 25-62-44-000-804-A AND AMM 25-62-44-400-803-A AND PERFORMED OPERATIONAL TEST IS OK
Part: SLIDE — DEFORMED (PAX DOOR) · airframe 30,161 hrs · 9,584 cycles
DURING HEAVY MAINTENANCE, DEFORMATION SLIDE RAFT PASSENGER CREW DOOR 832 AT AFT GALLEY AREA; (REF AEROMAN N/R 2021-156407) R & R ESCAPE SLIDE RAFT DOOR 832 IAW AMM 25-62-44-000-012-A AND AMM 25-62-44-400-007-A AND PERFORMED OPERATIONAL TEST IS OK
2020
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 27,859 hrs · 8,757 cycles
FT # 1710, PAP-FLL. EMERGENCY POWER SUPPLY UNIT (10WL) (FWD) BATTERY FAIL TEST; REMOVED AND REPLACED (10WL) EMRGENCY POWER SUPLY UNIT BATTERY PER AMM 33-57-38. OPS CHECK GOOD AT THIS TIME.
Part: LIGHT — FAILED (R1 DOOR SLIDE) · airframe 27,859 hrs · 8,757 cycles
FT # 1710, PAP-FLL. R1 DOOR SLIDE REQUIRES REPLACEMENT DUE TO EMERGENCY LIGHT FAILURE; REMOVED & REPLACED R1 DOOR SLIDE PER AMM 25-62-44-400-803-A OPS CHK OK. ACCOMPLISHED OPS TEST OF THE EMERGENCY LIGHTS IAW AMM 33-51-00-710-001.
2018
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 21,525 hrs · 6,468 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON MAIN CABIN FWD WET AREA FLOOR STRUCTURE AT Y254 BETWEEN FR 16 AND FR18 HAS CORROSION ON TOP SURFACE BS FR 16 -BS FR18 STR 23L; REMOVED CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-00-14-283-002. REMOVED AND REPLACED FLOORBEAM FROM FR 12 TO FR 24 Y254 STR 23L PER SRM 51-42-11 PARAG 2D, 2E, AND 2F. SRM 53-00-14-283-002. REF SERVICE ORDER 440497 NR 20452 FOR ALL WORK ACCOMPLISHED.
Part: STRUCTURE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 21,525 hrs · 6,468 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON REF NR 20453 MAIN CABIN FWD WET AREA FLOOR STRUCTURE -Y81 FR 16 STR 23R; REF NR 20453 REMOVED CORROSION ON FLOOR STRUCTURE -Y81 FR 16 STR 23R VERIFIED BEYOND ALLOWABLE LIMITS IAW SRM 53-11-14-283-007 REMOVED AND REPLACED IAW SRM 51-72-11 DRW D53114118.
Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 21,525 hrs · 6,468 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON REF NR 20386 MAIN CABIN FLOOR SUPPORT Y772 BETWEEN FR 66 & 67 STR 23; REF NR 20386 REMOVED AND REPLACED AFT CABIN FLOORBEAM FR 66 Y772 IAW SRM 51-42-11 & 53-00-14-283-002
Part: DOOR SILL — CORRODED (FUSELAGE) · corrosion level 2 · airframe 21,525 hrs · 6,468 cycles
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON REF NR 20449 AFT CABIN R2 DOOR SILL GIRT BAR AREA HAS SURFACE CORROSION FR 66 STR 23L -Y1732; REF NR 20449 REPAIRED AFT CABIN R2 DOOR SILL GIRT BAR FR 66 STR 23L -Y1732 IAW SRM 53-41-14-300-001 FIG 001 PRINCIPLE 10.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 21,360 hrs · 6,446 cycles
EMERGENCY LIGHT FAILED TO TEST. R & R THE EMERGENCY LIGHT BATTERY AT EPSU 10WL IAW AMM 33-51-38.
2017
Part: UNKNOWN — ODOR (CABIN) · airframe 17,722 hrs · 5,267 cycles
FUMES REPORTED IN CABIN BY FLIGHT ATTENDANTS. DIVERTED. TROUBLESHOT DEFECT IAW TSM 05-50-00 AND ACCOMPLISHED MULTIPLE ENGINE RUNS WITH DIFFRENT BLEED SOURCES AND APU BLEED IAW AMM 71-00-00. NO DEFECTS NOTED OR ODOR NOTED EITHER. AIRCRAFT OK FOR SERVICE.
Part: INTAKE — CONTAMINATED (APU) · airframe 17,239 hrs · 5,100 cycles
DURING DESCENT FROM 4000AGL AND BELOW, AN OVERWHELMING ODOR OF INDUSTRIAL FUMES. TROUBLESHOT IAW NOTICE 2017-T015A SECT B. FOUND THE FAINT ODOR WITH BLEEDS OFF AND CABIN FANS ON. REMOVED AND REPLACED RECIRCULATION FILTERS WITH APU BLEED. APU AIR INTAKE CONTAMINATED. CLEANED INTAKE, AFTER NO ODOR NOTED. ECS DECONTAMINATION PERFORMED IAW AMM 21-00-00. FINAL ENGINE RUNS AND APU RUN CHECKS NORNAL WITH EACH BLEED ISOLATED. NO ODOR NOTED WITH BLEEDS OFF NO ODOR NOTED. NOTED. NR 1 AND 2 ENGINES REPLACED. AIRCRAFT OK FOR SERVICE.
Part: ENGINE — FAILED (LEFT) · airframe 17,040 hrs · 5,033 cycles
EXPERIENCED STRONG FUMES ON DESCENT IN COCKPIT. CABIN FUMES SMELLED LIKE WET SOCKS AND DUSTY BURNING ODOR SIMILAR TO A HEATER TURNING ON FOR FIRST TIME. FUMES NOTICED AT FL215 AND WORSE BELOW FL160. SAME ODOR NOTICED ON DEPT BUT AT A LESSER STRENGTH AFTER FOLLOWING QRH PROCEDURES FUMES DEMINISHED AFTER TURNING OFF PACKS 1 AND 2 . FUMES WERE STRONGEST IN COCKPIT AND AFT CABIN. ON W/O 852394 REPLACED NR 2 ENGINE IAW TC A320-71-00-20-000-040. ENGINE NR 1 REPLACEMENT COMPLETED IAW TASK CARD UNDER WO 852396.
Part: ENGINE — FAILED (720001-01-001-RH) · airframe 17,040 hrs · 5,033 cycles
EXPERIENCED STRONG FUMES ON DESCENT IN COCKPIT. CABIN FUMES SMELLED LIKE WET SOCKS AND DUSTY BURNING ODOR SIMILAR TO A HEATER TURNING ON FOR FIRST TIME. FUMES NOTICED AT FL215 AND WORSE BELOW FL160. SAME ODOR NOTICED ON DEPT BUT AT A LESSER STRENGTH AFTER FOLLOWING QRH PROCEDURES FUMES DEMINISHED AFTER TURNING OFF PACKS 1 AND 2 . FUMES WERE STRONGEST IN COCKPIT AND AFT CABIN. ON W/O 852394 REPLACED NR 2 ENGINE IAW TC A320-71-00-20-000-040. NR 1 ENGINE REPLACEMENT COMPLETED IAW TASK CARD UNDER WO 852396.
Part: UNKNOWN — ODOR (CABIN) · airframe 17,007 hrs · 5,018 cycles
DURING DESCENT, PASSING 4000 FEET, A DIRTY SOCK ODOR WAS STRONG. FA'S ALSO CALLED UP TO SAY THEY SMELLED THE ODOR. REACTIVATED PACK 2 IAW 21-51-00-440-002 AND (M) PROCEDURES. ACCOMPLISHED HIGH POWER RUN IAW AMM 71-00-00-710-013-C. RAN THE NR 2 PACK FROM NR 2 ENGINE BLEED AND NR 1 ENGINE BLEED AND APU BLEED, ALL SEPARATELY. ALL OPS CHECKED OK. NO ODORS PRESENT. RAN PACK 2 IN ALL FIVE CONFIGS IAW INFO NOTICE 2017-T015A SECTION B TABLE 1 AND TSM 71-00-00-810-801-A, 49-00-81-810-874A. ACFT OK FOR SERVICE.
Part: UNKNOWN — ODOR (CABIN) · airframe 17,003 hrs · 5,017 cycles
MUSTY MILDEW ODOR DURING CLIMB OUT, PASSING THROUGH CLOUDS BUT THEN DISAPATED. POSSIBLY DURING CRUISE AGAIN. BUT STRONG DURING DESENT WHEN PASSING THROUGH CLOUDS. PERFORMED POST-WASH BORESCOPE INSPECTION ON NR 1 & 2 ENGINES, LPC STAGE 2.5 IAW AMM 72-00-00-200-1A. FOUND NO OIL PUDDLING OR ACTIVE LEAKS. PERFORMED CABIN ODOR IDENTIFICATION INSPECTION TSM 05-50-00-810-831-A. FOLLOWED INFO NOTICE 2017-T015A. CONFIRMED PACK 2 AT FAULT. ACCOMPLISHED TSM PROCEDURE WITH ASSITANCE OF FLIGHT CREW FOR ENG FAULT ISOLATION. PACK 2 REQUIRED DEACTIVATION, COMPLIED W/INFO NOTICE 2017-T015A SECTION C. A/C IS OK FOR SVC. MDDR CLEARED MX-4 UPDATED PLACARD REMOVED MCC NOTIFIED.
Part: FILTER — ODOR (CABIN) · airframe 16,895 hrs · 4,982 cycles
AN ODOR OF DIRTY SOCKS EXPERIENCED IN THE FLIGHT DECK DUIRNG CLIMB AND THROUGH 15000FT. APU WAS SHUTDOWN FOR TAKE OFF BUT CABIN CREW SAID THEY SMELLED IT ON TAKE OFF AT ROWS IN REAR OF THE ACFT. IT WAS A VERY SRTONG ODOR AND DISSAPATED WHILE CLIMBING THROUGH FL 250. THE ODOR RETURNED DURING DESCENT, 15000-11000 FT BY ALL CREW. ACCOMPLISHED A NR 1 & 2 ENGINE WATER WASH IAW AMM 72-00-00-100-900-A, & EC 720000-1-4. R & R THE OZONE FILTERS 1 AND 2 IAW AMM 21-51-41.
Part: FILTER — ODOR (CABIN) · airframe 16,895 hrs · 4,982 cycles
ODOR OF DIRTY SOCKS EXPERIENCED IN FLIGHT DECK, CLIMBING THROUGH 15000FT. APU WAS SHUTDOWN FOR TAKEOFF BUT CABIN CREW SAID THEY SMELLED IT ON TAKE OFF AT ROWS IN REAR OF THE ACFT. IT WAS A VERY SRTONG ODOR AND DISSAPATED WHILE CLIMBING THROUGH FL 250. THE ODOR RETURNED ON DESCENT 15000-11000 FT. ACCOMPLISHED A NR 1 & 2 ENGINE WATER WASH IAW AMM 72-00-00-100-900-A & EC 720000-1-4. R & R THE OZONE FILTERS 1 AND 2 IAW AMM 21-51-41.
2016
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 11,823 hrs · 3,542 cycles
FLT 552, DURING MAINTENANCE, IT WAS DISCOVERED THAT THE EMERGENCY LIGHTS FAILED OPS CHECK. R & R EMERGENCY LIGHT BATTERY AT FIN 10WL AND 11WL PER AMM 33-51-38. OPS CHECK OK. TEST PASSED.
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 11,823 hrs · 3,542 cycles
FLT 552, DURING MAINTENANCE, IT WAS DISCOVERED THAT THE EMERGENCY LIGHTS FAILED OPS CHECK.. R & R EMERGENCY LIGHT BATTERY AT FIN 10WL AND 11WL IAW AMM 33-51-38. OPS CHECKED OK. TEST PASSED.
2015
Part: PUMP — FAILED (FUEL SYSTEM) · airframe 8,754 hrs · 2,601 cycles
AFTER TAKEOFF, BURNING ODOR FILLED REAR CABIN AND COCKPIT, QUICKLY DISSAPATED. SHORTLY AFTER CENTER TANK PUMP 1 LOW PRESSURE. DID NOT RESET AFTER SELECTING CENTER TANK PUMP 1 OFF. ODOR DISAPPEARED COMPLETELY. NOTE NO SMOKE WAS SEEN AT ALL CENTER TANK SYSTEMS, PUMP, SINGLE. ACCOMPLISHED INSPECTION IAW TSM 24-00-00-810-823A. NO EVIDENCE OF ELECTRICAL OR ANY OTHER DAMAGE. R & R CTR TANK PUMP 1 SUPPLY GFI CONTACTOR IAW TSM 28-21-00, OPS TEST GOOD, NO FAULT NOTED.