N8305H

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Peninsula Airways Inc.Operatoron 2010-04-26Operator named in NTSB report

Accident & incident history

Accident · 2010-04-26 Operator named in NTSB report
PIPER PA-32-301 No injuries Part 135Peninsula Airways Inc.

Operated by PENINSULA AIRWAYS INC (per NTSB report)

Source: NTSB case ANC10LA032

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

7 reports on file, 1996-11-02 – 2019-12-08.

OTHER · 2019-12-08 Matched by certificate designator
ATA 5520

Part: PANEL — CRACKED (RH ELEVATOR) · airframe 26,834 hrs · 11,654 cycles

RH ELEVATOR PANEL 344PT IS CRACKED AT FASTNER HOLE; 2ND FROM AFT EDGE ON O/B ROW / EVALUATED DAMAGE TO LOWER SURFACE OF PANEL 344PT AND FOUND TO BE OUT OF LIMITS I/A/W BOEING 737 SRM 55-20-70. INSTALLED NEW/ SERVIABLE 344PT PANEL ON RH ELEVATOR I/A/W BOEING 737 SOPM 20-50-01 AND DRAWING # 183A0107 REV A. A-TAG= HI1427

Source: SDR SWAA2022041233454
OTHER · 2007-02-03 Unresolved
ATA 8500

Part: ENGINE — MAKING METAL · airframe 16,050 hrs

DURING ROUTINE INSPECTION FOUND METAL IN FILTER. SUSPECT METAL FROM CAM AND LIFTERS. LYCOMING RECOMMENDED ENGINE BE REMOVED AND SENT TO FACTORY FOR WARRANTY. ENGINE OVERHAULED BY LYCOMING 3/10/06. TSO 384.3

Source: SDR PNSA070107
ELECT. POWER LOSS-50 PC; WARNING INDICATION · 1999-06-24 Unresolved
ATA 2432

Part: BATTERY — DISCHARGED (BATTERY COMPT)

DURING CRUISE, CHARGING SYSTEM WOULD NOT INDICATE POSITIVE CHARGE RATE. RETURNED TO BASE. REPLACED BATTERY, OPS CHECK OK.

Source: SDR PNSA990603
SMOKE/FUMES/ODORS/SPARKS · 1997-02-07 Unresolved
ATA 3030

Part: SWITCH — SHORTED (CABIN)

SMOKE EMITTING FROM PITOT HEAT SWITCH. RETURNED TO BASE. CHANGED SWITCH, NO OTHER DAMAGE.

Source: SDR PNSA970201
OTHER · 1996-12-26 Unresolved
ATA 8010

Part: SWITCH — MALFUNCTIONED (STARTER)

STARTER WAS INTERMITTANT, RETURNED TO BASE.

Source: SDR PNSA1207
OTHER · 1996-11-22 Unresolved
ATA 2731

Part: CONTROLS — FROZEN (ELEVATOR TRIM)

ELEVATOR TRIM FROZEN, THAWED ICE, LUBED DRUM, CHECKS OK.

Source: SDR PNSA961104
OTHER · 1996-11-02 Unresolved
ATA 2731

Part: CONTROLS — LACK OF LUBE (ELEVATOR TRIM)

ELEVATOR TRIM STIFF. RETURNED TO AIRPORT.

Source: SDR PNSA961101