N837CA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

33 reports on file, 1995-10-17 – 2017-02-16.

OTHER · 2017-02-16 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 31,505 hrs · 34,625 cycles

EMERGENCY LIGHTS INOPERATIVE. R&R PS1 AND PS2 EMERGENCY BATTERIES OPS CHECK SAT.

Source: SDR JJBA20170216011
OTHER · 2017-02-10 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 31,478 hrs · 34,593 cycles

EMERGENCY LIGHT OVER MAIN CABIN DOOR IS DIM. REPLACED THE LAMPS. OPS CHECKED GOOD.

Source: SDR JJBA20170210009
Earlier reports · 1995–2016 · 31 reports

2016

SMOKE/FUMES/ODORS/SPARKS · 2016-12-09 Matched by certificate designator
ATA 2150

Part: ACM — SMOKE (NR 2) · airframe 31,178 hrs · 34,252 cycles

SMOKE IN CABIN, ELECTRICAL BURNING ODOR AFTER APU TURNED ON. SERVICED THE NR 2 ACM, PERFORMED RUNS, AND OPS CHECKED SAT. NO SMOKE OBSERVED.

Source: SDR JJBA20161209013
SMOKE/FUMES/ODORS/SPARKS · 2016-10-24 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 30,951 hrs · 33,994 cycles

FUEL ODOR IN CABIN WHILE APU OPERATING. RAN APU NO DEFECTS NOTED.

Source: SDR JJBA20161024033
OTHER · 2016-04-08 Matched by certificate designator
ATA 3230

Part: LOCK — ENGAGED (NLG) · airframe 30,004 hrs · 30,010 cycles

NOSE GEAR WOULD NOT RETRACT AFTER TAKEOFF. FOUND NOSE GEAR GND LOCK ENGAGED & DISENGAGED GND LOCK.

Source: SDR JJBA20160408008
OTHER · 2016-02-14 Matched by certificate designator
ATA 3350

Part: CONTACTOR — DIRTY (EMERGENCY LIGHT) · airframe 29,746 hrs · 32,632 cycles

EMERGENCY EXIT LIGHTS INOPERATIVE. REMOVED & CLEANED CONTACTORS.

Source: SDR JJBA20160214006
OTHER · 2016-02-01 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 29,746 hrs · 32,632 cycles

OVERHEAD EMER EXIT LIGHTS DO NOT ILLUMINATE. R & R BATTERIES, REPINNED SWITCH.

Source: SDR JJBA20160201007

2015

SMOKE/FUMES/ODORS/SPARKS · 2015-10-28 Matched by certificate designator
ATA 3413

Part: VSI — DEFECTIVE (NR 1) · airframe 29,137 hrs · 31,982 cycles

CAPTAINS INERTIAL VERTICAL SPEED INDICATOR SCREEN WENT BLANK, THEN THE SMELL OF SMOKE WAS IN THE COCKPIT. INSPECTED SYS & FOUND NR 1 INERTIAL VERTICAL SPEED INDICATOR DEFECTIVE.

Source: SDR JJBA20151028007
OTHER · 2015-05-04 Matched by certificate designator
ATA 5320

Part: CROSSBEAM — CRACKED (FUSELAGE) · airframe 28,403 hrs · 31,172 cycles

FLOOR CROSSBEAM AT FS 167.5 IS CRACKED 19 INCHES FROM PAX DOOR OPENING. REPAIRED FLOORBEAM & CUT OUT DAMAGED SECTION IAW DASH 8 300 RD 8-53-11111.

Source: SDR JJBA20150504005
OTHER · 2015-04-22 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (FUSELAGE) · airframe 28,403 hrs · 31,172 cycles

BAGGAGE BAY DOOR SURROUND SKIN, LOWER FWD CORNER OFFSET. ACCOMPLISHED PERMANENT REPAIR TO ACFT EXTERIOR SKIN BY CUTTING OUT DAMAGED AREA, PERFORMING NDT INSPECTION, FABRICATING & INSTALLING REPAIR DOUBLERS IAW RD 8-53-14157 ISSUE .

Source: SDR JJBA20150422003
OTHER · 2015-03-26 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 28,284 hrs · 31,061 cycles

EMERGENCY LIGHTS INOPERABLE. R & R ALL EMER LIGHTS BATTERIES.

Source: SDR JJBA20150326017
NO TEST · 2015-03-06 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — INOPERATIVE (CARGO BAY) · airframe 28,198 hrs · 30,982 cycles

BAGGAGE SMOKE WARNING TEST, TWO NOT WORKING. R & R AFT CEILING SMOKE DETECTOR, SYS FAILED. REINSTALLED ORIGINAL SMOKE DETECTOR.

Source: SDR JJBA20150306009
SMOKE/FUMES/ODORS/SPARKS · 2015-02-20 Matched by certificate designator
ATA 2120

Part: UNKNOWN — SMOKE (CABIN & COCKPIT) · airframe 28,140 hrs · 30,922 cycles

APU PUT SMOKE INTO CABIN & FLIGHT DECK. APU DID NOT SHUTDOWN ON ITS OWN. RAN APU, NO DEFECTS NOTED.

Source: SDR JJBA20150220007

2014

OTHER · 2014-09-09 Matched by certificate designator
ATA 6123

Part: AUTOFEATHER SYS — MALFUNCTIONED (NR 1) · airframe 27,242 hrs · 29,996 cycles

NUMBER 1 AUTO FEATHER FAILED ON TAKEOFF. RESET AUTO FEATHER SYS. PERFORMED OPERATIONAL CHECK, SYS OPERATED NORMALLY.

Source: SDR JJBA20140909005
OTHER · 2014-06-29 Matched by certificate designator
ATA 2421

Part: GENERATOR — OUT OF POSITION (NR 1 ENGINE) · airframe 26,869 hrs · 29,635 cycles

NUMBER 1 ENG LOST OIL PRESS IN FLIGHT. FOUND NR 1 ENG AC GEN SLID BACK OFF OF ITS BASE.

Source: SDR JJBA20140629002
NO TEST · 2014-03-10 Matched by certificate designator
ATA 2562

Part: BATTERY PACK — DISCHARGED (ELT) · airframe 26,229 hrs · 28,972 cycles

OPERATIONAL CHECK OF EMERGENCY LOCATOR TRANSMITTER, CHECK FAILED. R & R EMERGENCY LOCATOR TRANSMITTER BATTERY PACK ASSEMBLY.

Source: SDR JJBA20140310005
OTHER · 2014-03-07 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 26,210 hrs · 28,950 cycles

EMERGENCY LIGHTS WILL NOT STAY ILLUMINATED. R & R ALL EMERGENCY LIGHT BATTERIES.

Source: SDR JJBA20140307002

2013

OTHER · 2013-11-06 Matched by certificate designator
ATA 5220

Part: DITCHING DAM — LOW PRESSURE · airframe 25,623 hrs · 28,267 cycles

TYPE III EXIT DITCHING DAMS DROPPED TO 1400 PSI. INSPECTED AND SERVICED TO 1700 PSI - NO FURTHER FAULTS.

Source: SDR JJBA20131106005
NO TEST · 2013-08-28 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 25,236 hrs · 27,769 cycles

ROW 1 AND 2 EMERGENCY FLOOR LIGHTS INOPERATIVE. R & R LIGHT, OPS CHECKED SATISFACTORY.

Source: SDR JJBA20130828016
NO TEST · 2013-03-30 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 24,299 hrs · 26,736 cycles

DURING PREFLIGHT, DISCOVERED FLOOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE LIGHT, OPS CHECKED SATISFACTORY.

Source: SDR JJBA20130330015
NO TEST · 2013-03-15 Matched by certificate designator
ATA 3397

Part: CONNECTOR — UNSECURE (EMERGENCY LIGHTS) · airframe 24,206 hrs · 26,634 cycles

DURING PREFLIGHT THE CREW REPORTED THAT FLOOR EMERGENCY LIGHTS AT ROW 6-7 WERE INOPERATIVE. CONNECTOR HAD BECOME DISCONNECTED. SECURED CONNECTOR, OPS CHECKED GOOD.

Source: SDR JJBA20130315005

2012

NO TEST · 2012-11-03 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 23,510 hrs · 25,801 cycles

DURING A LINE CHECK INSPECTION, A TECH NOTICED THE SECOND RED LIGHT ON THE FWD FLOOR EMERGENCY LIGHT STRIP WAS INOPERATIVE. R & R THE LIGHT STRIP AND CONDUCTED AN OPS CHECK WHICH PRODUCED SATISFACTORY RESULTS.

Source: SDR JJBA20121103010
OTHER · 2012-10-28 Matched by certificate designator
ATA 5397

Part: WIRE — OUT OF POSITION (FUSELAGE) · airframe 23,492 hrs · 25,778 cycles

ON ARRIVAL AT THE GATE, THE F/A WAS UNABLE TO OPEN THE MAIN CABIN DOOR. AN EMERERGENCY WAS DECLARED. MX FOUND WIRES BETWEEN THE WALL PUSHING THE WALL INTO THE DOOR. THE WIRES WERE REPOSITIONED AND THE WALL FASTENERS WERE TIGHTENED. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20121028010
NO TEST · 2012-03-20 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 22,379 hrs · 24,473 cycles

DURING A ROUTINE INSPECTION, FOUND THE CABIN LEFT EGRESS LIGHT AT ROW 4A INOPERATIVE. R & R LIGHT BULB IRW 33-51-00 OF THE ACFT MM. AN OPS CHECK WAS PERFORMED WITH SATISFACTORY RESULTS. THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20120320008
NO TEST · 2012-01-16 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 22,037 hrs · 24,089 cycles

DURING OVERNIGHT MX INSPECTION, THE MX CREW NOTICED THE LT AFT EGRESS LIGHT WAS INOPERATIVE WHILE PERFORMING EXTERNAL LIGHT CHECKS. THE LIGHT BULB WAS REPLACED, OPS CHECK WAS PERFORMED, AND SYS CHECKED SATISFACTORY.

Source: SDR JJBA20120116701

2011

NO TEST · 2011-09-10 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 21,342 hrs · 23,325 cycles

FLIGHT CREW REPORTED RT FWD EMERGENCY LIGHTS ABOVE THE FWD EMERGENCY EXIT ARE NOT WORKING. MX CREW COULD NOT FIND ANY DEFECTS NOTED. PERFORMED OPS CHECK WAS SATISFACTORY.

Source: SDR JJBA20110910001

2002

OTHER · 2002-05-29 Matched by certificate designator
ATA 1430

Part: BOLT — BENT (RUDDER)

DURING INSPECTION OF RUDDER CONTROL SYSTEM, FOUND TORQUE TUBE MOUNT BOLTS LOOSE AND CONTROL HORN MOUNT BOLT BENT. PARTS RETURNED TO MFG FOR ANALYSIS, UNIT UNDER INVESTIGATION.

Source: SDR JJB2002F00001

2000

SMOKE/FUMES/ODORS/SPARKS · 2000-05-24 Matched by certificate designator
ATA 2131

Part: CONTROLLER — SEIZED (COCKPIT)

DURING CLIMB-OUT FROM SYR, CREW DETECTED AND ELECTRICAL SHORT SMELL, FOLLOWED BY PRESSURIZATION FAILURE. AIRCRAFT RETURNED TO THE FIELD AND MAINTENANCE PERFORMED A THOROUGH INSPECTION OF CENTER CONSOLE WHERE PRESSURIZATION CONTROLLER IS MOUNTED. INSPECTION RESULTED IN NO FAULT FOUND TO CONFIRM SMELL. CONTROLLER REPLACED TO CORRECT PRESSURIZATION PROBLEM. AIRCRAFT RETURNED TO SERVICE. (M)

Source: SDR 20000725AP007

1998

OTHER · 1998-08-07 Matched by certificate designator
ATA 3231

Part: CAM — BROKEN (LT MLG DOOR)

NR 2 NLG DOOR UPLOCK CAM BROKEN. CAUSE UNKNOWN. REPLACED BROKEN CAM. (M)

Source: SDR 98ZZZM621
WARNING INDICATION · 1998-06-08 Matched by certificate designator
ATA 3231

Part: CAM — FAILED (LT GEAR DOOR)

LEFT NLG WOULD NOT RETRACT FOLLOWING TAKEOFF. LEFT GEAR DOOR CAM ASSY FAILED. REPLACED LT GEAR DOOR CAM ASSY. OPS SATISFACTORY. (X)

Source: SDR 98ZZZX2506

1997

OTHER · 1997-06-17 Matched by certificate designator
ATA 2424

Part: GEN CONTL UNIT — FAILED (LT ENGINE)

LEFT GENERATOR INOPERATIVE, REPLACED GENERATOR CONTROL UNIT.

Source: SDR 97ZZZM764
OTHER · 1997-06-16 Matched by certificate designator
ATA 5230

Part: SEAL — FAILED (CARGO DOOR)

PRESSURIZATION SYSTEM INOPERATIVE. INVESTIGATION FOUND CARGO DOOR SEAL FAILED. REPLACED SEAL.

Source: SDR 97ZZZX3367

1995

OTHER · 1995-10-17 Matched by certificate designator
ATA 2562

Part: ELT TRAY — CRACKED (AFT FUSELAGE)

DURING SCHEDULED INSPECTION OF AFT FUSELAGE, THE ELT MOUNTING TRAY WAS FOUND CRACKED AROUND 2 MOUNT HOLES. ADDITIONALLY, A 3 INCH CRACK ON AFT END OF TRAY WAS NOTED. COMPLETE ELT ASSEMBLY WAS REPLACED WTIH NEW UNIT.

Source: SDR 95ZZZX6367