N839CA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

53 reports on file, 1995-07-27 – 2017-08-22.

OTHER · 2017-08-22 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 32,580 hrs · 35,775 cycles

EMER LIGHTS ON OVHD NR 2,3,6 INOP. R&R PS 3 POWER SUPPLY AND BATTERY OPS CHECK SAT NO DEFECTS NOTED. POWER SUPPLY UNIT PN 60-3844-3 SN 3600 TT 32579.88 TC 35775.

Source: SDR JJBA20170822019
OTHER · 2017-08-17 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 32,548 hrs · 35,742 cycles

TWO CEILING EMERGENCY LIGHTS FOUND INOPERATIVE. R & R THE BATTERY PACK.

Source: SDR JJBA20170817016
SMOKE/FUMES/ODORS/SPARKS · 2017-02-12 Matched by certificate designator
ATA 2120

Part: UNKNOWN — HAZE (CABIN) · airframe 31,878 hrs · 35,004 cycles

HAZE IN THE CABIN WITH APU RUNNING. RAN APU FOR EXTENDED PERIOD WITH BLEEDS ON IAW AMM 49-20-00. NO SMOKE OR HAZE NOTED. OPS CHECKED GOOD.

Source: SDR JJBA20170212012
Earlier reports · 1995–2016 · 50 reports

2016

OTHER · 2016-10-13 Matched by certificate designator
ATA 3397

Part: CONNECTOR — DAMAGED (CABIN LIGHTS) · airframe 31,274 hrs · 34,328 cycles

ALL OF THE OVERHEAD LIGHTS ON THE RIGHT SIDE INOPERATIVE. CRIMPED ELECTRICAL CONNECTOR 3320-J38. OPS CHECKED GOOD.

Source: SDR JJBA20161013017
WARNING INDICATION · 2016-09-23 Matched by certificate designator
ATA 3417

Part: ADC — INOPERATIVE (NR 2) · airframe 31,188 hrs · 34,230 cycles

GEAR UNSAFE HORN SOUNDING WHEN GEAR IS RETRACTED. R & R NR 2 ADC, OPS CK SATISFACTORY ON GROUND, REQUIRES OCF. AN EMERGENCY WAS DECLARED AND RETURN TO FIELD.

Source: SDR JJBA20160923010
OTHER · 2016-07-26 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — MALFUNCTIONED (EMERGENCY LIGHTS) · airframe 30,947 hrs · 33,946 cycles

EMERGENCY EXIT LIGHT. RACKED PS6 BATTERY PACK. OPS CHECK GOOD.

Source: SDR JJBA20160726008
OTHER · 2016-05-14 Matched by certificate designator
ATA 5541

Part: RIB — DAMAGED (RUDDER) · airframe 30,657 hrs · 33,598 cycles

DAMAGE FOUND ON TOP OF TRAILING RUDDER. REMOVED DAMAGE ON TOP OF TRAILING RUDDER.

Source: SDR JJBA20160514008
OTHER · 2016-01-07 Matched by certificate designator
ATA 2560

Part: DITCHING DAM — LOW PRESSURE (CABIN) · airframe 29,956 hrs · 32,845 cycles

RIGHT SIDE DITCHING DAM PRESS INDICATES 1000 PSI. SERVICED DITCHING DAM TO PROPER PSI.

Source: SDR JJBA20160107005

2015

OTHER · 2015-11-13 Matched by certificate designator
ATA 5330

Part: SKIN PANEL — DENTED (FUSELAGE) · airframe 29,727 hrs · 32,599 cycles

DISCOVERED ACFT DAMAGE NEAR LOWER FUSELAGE ON RT SIDE, DENT, DURING L CHECK. TWO DENTS & SCRATCH BETWEEN X219.0 - X232.5 & BETWEEN STRINGERS 27S - 29S. REPAIRED DAMAGE IAW RD 8-53-14442.

Source: SDR JJBA20151113004
OTHER · 2015-10-18 Matched by certificate designator
ATA 2697

Part: CONNECTOR — DIRTY (SMOKE WARNING) · airframe 29,611 hrs · 32,465 cycles

BAGGAGE SMOKE WARNING TEST 2 WON'T TEST. CLEANED & RE-SEATED CONNECTOR.

Source: SDR JJBA20151018004
OTHER · 2015-10-09 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 29,554 hrs · 32,401 cycles

LAST 2 EMER CEILING LIGHT INOPERATIVE. PERFORMED OPERATIONS CHECK OF THE EMER LIGHT SYS.

Source: SDR JJBA20151009002
OTHER · 2015-10-07 Matched by certificate designator
ATA 3350

Part: BATTERY — NOT SEATED (CABIN) · airframe 29,548 hrs · 32,394 cycles

EMERGENCY THRESHOLD LIGHT INOPERATIVE. RE-SEATED BATTERY.

Source: SDR JJBA20151007001
OTHER · 2015-08-05 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 29,426 hrs · 32,256 cycles

LEFT FWD SEAT TRACK CORRODED. R & R SEAT TRACK.

Source: SDR JJBA20150805004
OTHER · 2015-08-02 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (FUSELAGE) · airframe 29,426 hrs · 32,256 cycles

FORWARD RT INBD SEAT TRACK CORRODED. REPAIRED IAW RD 8-53-14284.

Source: SDR JJBA201508020001
OTHER · 2015-07-26 Matched by certificate designator
ATA 5350

Part: TAIL CONE — NICKED (FUSELAGE) · airframe 29,426 hrs · 32,256 cycles

RIGHT SIDE TAIL CONE AT FS 762.409 & FS 780.252 HAS A NICK. REPAIRED NICK IAW RH 8-55-2867. CUT OUT DAMAGED AREA.

Source: SDR JJBA20150726007
FLUID LOSS; WARNING INDICATION · 2015-05-14 Matched by certificate designator
ATA 3250

Part: MANIFOLD — LEAKING (NLG STEERING) · airframe 29,203 hrs · 32,023 cycles

ON FINAL WHEN GEAR SELECTED DOWN, OBSERVED THREE GREEN & NO RED & NR 2 ENG HYD PUMP CAUTION ILLUMINATED. CREW OBSERVED HYD QTY DECREASED FROM FOUR TO ONE QUART THEN BOTH OTBD SPLR HYD CAUTION LIGHTS ILLUMINATED ALONG WITH NOSE STEERING CAUTION LIGHT. R & R STEERING MANIFOLD.

Source: SDR JJBA20150514006
OTHER · 2015-05-06 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 29,152 hrs · 31,968 cycles

EMERGENCY LIGHTS WILL NOT ILLUMINATE. R & R EMER LIGHT BATTERIES.

Source: SDR JJBA20150506003
OTHER · 2015-04-08 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 28,966 hrs · 31,774 cycles

EMERGENCY LIGHTS WILL NOT ILLUMINATE. R & R ALL EMER LIGHT BATTERIES.

Source: SDR JJBA20150408005
OTHER · 2015-02-03 Matched by certificate designator
ATA 7200

Part: ENGINE — MALFUNCTIONED · airframe 31,787 hrs · 43,454 cycles

WHILE IN DESCENT, BOTH ENGINES WENT TO FULL POWER BY THEMSELVES. PERFORMED ENGINE RUNS ON LT & RT ENGINE AT DIFFERENT POWER SETTINGS. PERFORMED GVI OF LT & RT PROP ASSEMBLY. NO DEFECTS NOTED.

Source: SDR JJBA20150203012
FALSE WARNING · 2015-01-11 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — FALSE ACTIVATION (LAVATORY) · airframe 28,479 hrs · 31,265 cycles

LAVATORY SMOKE DETECTOR BEEPING IN FLIGHT WITH NO VISIBLE SMOKE. R & R LAVATORY SMOKE DETECTOR.

Source: SDR JJBA20150111006

2014

OTHER · 2014-11-10 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 28,095 hrs · 30,882 cycles

EXIT LIGHT OVER TYPE TWO EXIT DOES NOT ILLUMINATE. R & R ALL SEVEN EMER LIGHT BATTERIES.

Source: SDR JJBA20141110004
PARTIAL RPM/PWR LOSS · 2014-09-30 Matched by certificate designator
ATA 7321

Part: FUEL CONTROL — MALFUNCTIONED (NR 2 ENGINE) · airframe 27,829 hrs · 30,620 cycles

NUMBER 2 ENG WENT TO ZERO PERCENT TORQUE. R & R FUEL CONTROL & FUEL PUMP. RIG & LEAK CHECKED GOOD. PERFORMED MFC POWER RUNS & ALL READINGS WITHIN LIMITS.

Source: SDR JJBA20140930001
SMOKE/FUMES/ODORS/SPARKS · 2014-08-08 Matched by certificate designator
ATA 2150

Part: A/C PACK — FAULTY (AC BAY) · airframe 27,497 hrs · 30,290 cycles

SMOKE IN THE COCKPIT WITH BLEEDS ON, WHEN SELECTED OFF SMOKE WENT AWAY & NO SMOKE IN THE CABIN TO REPORT. DEFERRED IAW MEL. R & R NR 2 PACK. OPERATIONAL CHECKED SATISFACTORY.

Source: SDR JJBA20140808002
PARTIAL RPM/PWR LOSS · 2014-07-08 Matched by certificate designator
ATA 7200

Part: ENGINE — POWER LOSS (NR 1) · airframe 27,336 hrs · 30,128 cycles

ABORTED TAKEOFF, NR 1 ENG DID NOT ACHIEVE TAKEOFF POWER.

Source: SDR JJBA201407080016
OTHER · 2014-07-07 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 27,331 hrs · 30,123 cycles

EMERGENCY LIGHTS INOPERABLE AT ALL SWITCH POSITIONS. CHARGED BATTERIES.

Source: SDR JJBA20140707012
OTHER · 2014-07-07 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 27,331 hrs · 30,123 cycles

EMERGENCY LIGHTS COME ON & GO OFF. R & R EMER BATTERIES.

Source: SDR JJBA20140707014
OTHER · 2014-06-14 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — DISCHARGED (CABIN) · airframe 27,222 hrs · 30,016 cycles

EMERGENCY DO NOT ILLUMINATE WITH FLIGHT ATTENDANT`S PUSH BUTTON IN CABIN. CHARGED EMERGENCY POWER SUPPLY.

Source: SDR JJBA20140614005
SMOKE/FUMES/ODORS/SPARKS · 2014-02-23 Matched by certificate designator
ATA 2120

Part: UNKNOWN — SMOKE (CABIN) · airframe 26,594 hrs · 29,357 cycles

SMOKE IN CABIN WHEN APU STARTED. DEFERRED IAW MEL. PERFORMED OPERATIONAL CHECK OF APU, NO SMOKE OR FUMES CAUSED BY DEICE FLUID IN APU INTAKE.

Source: SDR JJBA20140223012
OTHER · 2014-01-30 Matched by certificate designator
ATA 2560

Part: LINE — LOOSE (BOTTLE) · airframe 26,484 hrs · 29,233 cycles

LEFT DITCHING DAM LOW. SECURED LINE FROM LT N2 BOTTLE TO GAUGE SERVICED TO 1500.

Source: SDR JJBA20140130019
FLUID LOSS · 2014-01-24 Matched by certificate designator
ATA 3230

Part: TUBE — LEAKING (LANDING GEAR) · airframe 26,474 hrs · 29,221 cycles

SMOKE IN CABIN AT GATE. TYPE THREE EMERGENCY EXIT PULLED, DITCHING DAM POPPED FLUID LEAKING FROM BELLY. BOTH ENGS OFF & APU IS THE ONLY AIRCRAFT POWER. FOUND SMOKE TO BE HYD FLUID. R & R GEAR DOWN TUBE ASSEMBLY.

Source: SDR JJBA20140124015

2013

OTHER · 2013-11-03 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT) · airframe 2,607 hrs · 28,737 cycles

EMERGENCY THRESHOLD LIGHT BY ROW 10 NOT ILLUMINATING. R & R BATTERY PACK. OPS CHECK SATISFACTORY.

Source: SDR JJBA20131103002
NO TEST · 2013-08-07 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 25,528 hrs · 28,112 cycles

EXTERNAL AND INTERNAL EMERGENCY LIGHTS WILL NOT ILLUMINATE. R & R EMERGENCY LIGHT POWER SUPPLY, OPS CHECKED SATISFACTORY.

Source: SDR JJBA20130807002
OTHER · 2013-07-31 Matched by certificate designator
ATA 7314

Part: PUMP — MALFUNCTIONED (NR 1 ENGINE FUEL) · airframe 25,480 hrs · 28,063 cycles

NR 1 ENGINE FLUCTUATED. R & R ENGINE MFC/HP FUEL PUMP. OPS AND LEAK CHECKS SATISFACTORY.

Source: SDR JJBA20130731014
FLUID LOSS; WARNING INDICATION · 2013-02-11 Matched by certificate designator
ATA 2910

Part: UNION — BROKEN (HYD SYSTEM) · airframe 24,467 hrs · 26,911 cycles

DURING CRUISE FLIGHT THE CREW REPORTED THAT THE NR 2 HYD PUMP ANNUNCIATOR ILLUMINATED. CREW OBSERVED THE NR 2 HYD QTY TO BE NEAR ZERO. DECLARED AN EMERGENCY. LANDED SAFELY. GROUND MX CREW INSPECTED AND FOUND THE UNION FITTING ON THE PRESSURE MANIFOLD BROKEN. R & R FITTING. REPLENISHED HYD FLUID IN NR 2 SYSTEM. BLED SYS OF AIR AND CHANGED THE FILTERS IN THE SYS. ENGINE DRIVEN PUMP WAS CHANGED DUE TO THE FACT IT WAS REPORTED TO HAVE OPERATED IN EXCESS OF 15 MINUTES WITH NO FLUID. ALL LEAK AND OPS CHECKS WERE SATISFACTORY.

Source: SDR JJBA20130211008

2012

NO TEST · 2012-10-31 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 24,057 hrs · 26,426 cycles

DURING PRE FLIGHT, THE CREW NOTICED THE GALLEY EMERGENCY LIGHT EXIT SIGN WAS NOT ILLUMINATING. MX FOUND THE EMERGENCY LIGHT BATTERY DEPLETED. R & R BATTERY, OPS CHECK PRODUCED SATISFACTORY RESULTS. ACFT RETURNED TO SERVICE.

Source: SDR JJBA20121031008
SMOKE/FUMES/ODORS/SPARKS · 2012-10-15 Matched by certificate designator
ATA 2121

Part: FAN — FAILED (COCKPIT) · airframe 23,988 hrs · 26,338 cycles

AFTER PUSH BACK, THE CREW IN THE COCKPIT SMELLED A SMOKE LIKE ODOR RESONATING FROM THE CO PILOT INSTRUMENT PANEL. THE CREW DECLARED AN EMERGENCY AND RETURNED TO THE GATE. MX INVESTIGATED THE REPORTED ISSUE AND FOUND THE EFIS COOLING FAN JAMMED AND OVERHEATING. THEY R & R THE EFIS COOLING FAN. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AND THE SMOKE LIKE SMELL WAS NO LONGER PRESENT. THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20121015003
NO TEST · 2012-04-26 Matched by certificate designator
ATA 3350

Part: LIGHT — BROKEN (CABIN) · airframe 22,943 hrs · 25,175 cycles

DURING PRE-FLIGHT, CREW NOTICED FORWARD SECTION OF FLOOR EMERGENCY LIGHTING DID NOT ILLUMINATE WHEN TESTING. DISCOVERED THE FORWARD SECTION OF THE EMERGENCY FLOOR LIGHTING WAS BROKEN. R & R EMERGENCY LIGHT IAW AMM 33-51-00. AN OPS CHECKED SATISFACTORY AND ACFT RETURNED TO SERVICE.

Source: SDR JJBA20120426008
NO TEST · 2012-02-08 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 22,524 hrs · 24,660 cycles

DURING PRE-FLIGHT INSPECTION, FLIGHT CREW NOTICED THAT THE F/A EMERGENCY NORMAL GREEN LIGHT WAS INOPERATIVE. GROUND MX CREW R & R NORMAL GREEN EMERGENCY LIGHT BULB. PERFORMED OPS CHECK OF EMERGENCY LIGHTING SYSTEM, OPS CHECKS WERE SATISFACTORY. ACFT RELEASED TO FLIGHT STATUS.

Source: SDR JJBA20120208002
NO TEST · 2012-02-06 Matched by certificate designator
ATA 3397

Part: CONNECTOR — UNSECURE (EMERGENCY LIGHTS) · airframe 22,513 hrs · 24,647 cycles

FLOOR EMERGENCY ESCAPE PATH LIGHTING AT SEAT ROW 10-11, FOUND INOPERATIVE DURING FLIGHT CREW GROUND TEST. RESEATED CONNECTOR ON FLOOR EMERGENCY LIGHTS AT ROW 10-11. OPS CHECKED SATISFACTORY WITH NO ADDITIONAL DEFECTS.

Source: SDR JJBA20120206001

2011

FALSE WARNING · 2011-11-30 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — MALFUNCTIONED · airframe 22,123 hrs · 24,218 cycles

FLIGHT CREW REPORTED THAT THE SMOKE DETECTOR WARNING LIGHT FLICKERED ON FINAL. MX R & R SMOKE DETECTOR. PERFORMED OPS CHECK SATISFACTORY.

Source: SDR JJBA2011130100001
FALSE WARNING · 2011-10-08 Matched by certificate designator
ATA 2611

Part: SENSOR — DIRTY (SMOKE DETECTOR) · airframe 21,828 hrs · 23,894 cycles

FLIGHT CREW REPORTED BAGGAGE SMOKE DETECTOR LIGHT ILLUMINATED ON LANDING ROLL. MX CREW CLEANED SENSING COMPONENTS, PERFORMED OPS CHECK SATISFACTORY.

Source: SDR JJBA20111008001
OTHER · 2011-09-27 Matched by certificate designator
ATA 3242

Part: BRAKE — BROKEN (MLG) · airframe 21,774 hrs · 23,833 cycles

DURING LINE CHECK, MX FOUND MAIN WHEEL BRAKE ROTOR IN PIECES. R & R BRAKE, PERFORMED OPS AND LEAK CHECK SATISFACTORY.

Source: SDR JJBA20110927001A

2003

OTHER · 2003-12-09 Matched by certificate designator
ATA 1430

Part: BOLT — BENT (CONTROL HORN) · airframe 4,758 hrs · 6,354 cycles

DURING DETAIL NR 6 INSPECTION FOUND RUDDER CONTROL HORN MOUNT BOLT BENT AND TORQUE TUBE MOUNT BOLTS LOOSE.

Source: SDR 8394094

2002

ELECT. POWER LOSS-50 PC · 2002-11-14 Matched by certificate designator
ATA 2430

Part: CIRCUIT BOARD — INOPERATIVE (RT GENERATOR) · airframe 3,093 hrs · 4,161 cycles

RT GENERATOR FELL OFF LINE IN FLIGHT AND FLIGHT CREW WAS UNABLE TO TIE RIGHT GENERATOR BUS BACK TO ELECTRICAL SYSTEM. MAINTENANCE REPLACED RIGHT DC POWER A257 BUS TIE CONTROL PCB ASSEMBLY.

Source: SDR 8393298

2000

OTHER · 2000-06-25 Matched by certificate designator
ATA 5310

Part: DOOR FRAME — FRACTURED (FUSLEAGE)

ENTRANCE DOOR, FORWARD SUPPORT CABLE ANCHOR BROKEN. ANCHOR IS MADE FROM WRONG TYPE MATERIAL AND BREAKS WHEN ANY SIDE LOAD IS APPLIED TO CABLE; THUS, CREATING A SAFETY HAZARD. (X)

Source: SDR 20001115SH017

1998

OTHER · 1998-08-11 Matched by certificate designator
ATA 3230

Part: VALVE — FAILED (LT WING)

LANDING GEAR WILL NOT EXTEND NORMALLY MANUAL EXTENSION ONLY. LANDING GEAR SERVICE VALVE FAILURE. REPLACED GEAR SERVICE VALVE. (M)

Source: SDR 98ZZZM620

1997

FLUID LOSS · 1997-09-02 Unresolved
ATA 6120

Part: PITCH CHANGE ROD — CRACKED (PROPELLER)

PITCH CHANGE ROD CRACKED IN LAST THREAD ON ENGINE SIDE. CRACK PROPAGATED THROUGH THREAD TO INSIDE CAUSING OIL LEAK. CRACK FOUND DURING MAGNETIC PARTICLE INSPECTION AND VERIFIED DURING PRESSURE CHECK OF ROD OUTSIDE OF PROPELLER. ROD WAS NEW AT OVERHAUL.

Source: SDR 97ZZZX4291
OTHER · 1997-07-14 Matched by certificate designator
ATA 3425

Part: DISPLAY PROCESSR — FAILED (COCKPIT)

NR 2 DISPLAY PROCESSER UNIT FAILED. REPLACED DPU-84.

Source: SDR 97ZZZM787
OTHER · 1997-07-10 Matched by certificate designator
ATA 6112

Part: DE-ICE BOOT — TORN (RIGHT PROP)

RIGHT PROP ONE DE-ICE BOOT TORN.

Source: SDR 97ZZZM767
OTHER · 1997-06-26 Matched by certificate designator
ATA 3233

Part: ACTUATOR — FAILED (NLG)

NO NOSE GEAR DOWN INDICATIONS REPORTED. FOUND NLG ACTUATOR WITH OPEN CIRCUIT.

Source: SDR 97ZZZX3362
OTHER · 1997-03-15 Matched by certificate designator
ATA 6140

Part: TACH GENERATOR — SHAFT SHEARED (LT POWER SECTION)

LEFT PROP INDICATOR INOPERATIVE.

Source: SDR 97ZZZM566

1995

OTHER · 1995-09-27 Matched by certificate designator
ATA 2562

Part: ELT TRAY — BROKEN (AFT FUSELAGE)

DURING SCHEDULED MAINTENANCE, THE ELT WAS DISCOVERED UNSECURED. MOUNTING TRAY FOUND BROKEN IN HALF. ELT WAS HANGING FROM REMOTE SWITCH WIRING AND ANTENNA CABLE. RUDDER CONTROL CABLE PULLEY AT FS 570- 107 CHIPPED, CAUSED BY A PIECE OF MOUNTING TRAY JAMMED IN PULLEY. OPERATOR BELIEVES BROKEN TRAY CAUSED BY ACCUMULATION OF MOISTURE (WATER) AND SUBSEQUENT FREEZING. ALL DAMAGE COMPONENTS HAVE BEEN REPLACED WITH NEW.

Source: SDR 95ZZZM548
INFLIGHT SEPARATION · 1995-07-27 Matched by certificate designator
ATA 6112

Part: DE-ICE BOOT — MISSING (RT PROPELLER)

RIGHT PROP, BLADE S/N 317MA, MISSING DE-ICE BOOT. PROPELLER AND BLADES WERE OVERHAULED BY HARTZELL AT WHICH TIME NEW BOOTS WERE INSTALLED. UPON INSPECTION OF BLADE, SUBMITTER STATES THE PROBLEM LIES WITH THE PAINT BEING APPLIED. THE BLADES PRIOR TO BOOT INSTALLATION. (M)

Source: SDR 95ZZZM234