N875JX

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
CORPORATE AIRLINESOperatoron 2004-10-19Operator named in NTSB report

Accident & incident history

Accident · 2004-10-19 Operator named in NTSB report
British Aerospace Jetstream 32 Fatal injury Part 121CORPORATE AIRLINES

Operated by CORPORATE AIRLINES (per NTSB report)

Source: NTSB case DCA05MA004

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

23 reports on file, 1995-06-23 – 2001-12-06.

OTHER · 2001-12-06 Unresolved
ATA 7603

Part: CONTROL CABLE — BROKEN (POWER LEVER)

AIRCRAFT PREPARED TO DEPART GATE, AS THE POWER LEVERS WERE PUSHED FORWARD. THE CREW NOTICED THAT THE LT ENGINE WAS NOT RESPONDING TO THE INPUT. DURING INSPECTION BY MAINTENANCE PERSONNEL. THE LT POWER LEVER CABLE WAS FOUND SHEARED. THE CABLE HAD SHEARED APPROX. 12 INCHES FROM THE ATTACHMENT POINT OF THE POWER LEVER ARM WHERE THE FIRST UNDER FLOOR CABLE PULLEY IS LOCATED. THESE CABLES ARE SUBJECT OF AD (10,000 CYCLES LIFE LIMIT) THIS CABLE HAD 6125 CYCLES REMAINING. THE CABLE WAS REPLACED WITH NEW TYPE (PN 1379164E408) AND THE AIRCRAFT RETURNED TO SERVICE.

Source: SDR O3X2001F00000
PARTIAL RPM/PWR LOSS · 2001-01-30 Matched by certificate designator
ATA 7700

Part: CONNECTOR (ENG COMPT)

TBN - FLT 7842 - AIRCRAFT WAS EN-ROUTE FROM TBN TO STL, WHEN THE RIGHT ENGINE STARTED TO HAVE TORQUE AND TEMP FLUCTUATIONS. NORMAL PROCEDURES WERE FOLLOWED AND THE ENGINE WAS SHUTDOWN. THE AIRCRAFT LANDED SAFELY AT STL WITHOUT FURTHER INCIDENTS. ENGINE GROUND RUNS CONFIRMED THE FLUCTUATING TORQUE AND TEMP. THE TTL COMPUTER WAS TURNED OFF AND THE ENGINE THEN MAINTAINED A CONSTANT TORQUE AND TEMP. THE AIRCRAFT WAS FERRIED FROM STL TO MQY WITH THE TTL OFF FOR REPAIR. ON ARRIVAL AT MQY, SEVERAL ENGINE RUN WERE PERFORMED WAS UNABLE TO DUPLICATE THE FLUCTUATIONS WITH OR WITHOUT THE TTL COMPUTER ON LINE. FURTHER INSPECTION REVEALED THAT THE CANNON PLUG TO THE TTL VALVE DID NOT HAVE A BACKSHELL INSTALLED THIS EX

Source: SDR FJT01018751
Earlier reports · 1995–2000 · 21 reports

2000

PARTIAL RPM/PWR LOSS · 2000-10-17 Unresolved
ATA 7210

Part: HARNESS — CHAFED (RT NACELLE)

REFERENCE SRD FJT00108751: WHILE ENROUTE FROM STL TO UIN AT AN ALTITUDE OF 4,000 FT THE R/H ENG EGT & TORQUE INST BEGAN TO FLUCTUATE/ A/C YAWED & CONT'D TO DO SO. NORMAL PROC. WERE FOLLOWED & ENGINE REMAINED UNCONTROLLABLE. RT ENG WAS SHUT DOWN. CREW DECLARED EMERGENCY/ A/C LANDED SAFELY AT UIN WITHOUT INC. ENG WERE PERFORMED, WAS UNABLE TO DUPLICATE THE PROB WITH THE TTL COMP. OFF. THE CREW MEL, THE TTL AND A/C ONT'D IN SERVICE. ENG/A/C HAS HISTORY OF FALSE TEMP. & TORQUE INDICATIONS A/C RETURNED TO STL. ENG RUNS & INSP. OF IND. SYS. WAS PERFORMED/NO DISCRE. NOTED. A/C ARRIVED MQY FROM STL AND TTL VALVE WAS REPLACED & MEL CLEARED. A/C WILL RETURN TO MQY FOR FURTHER TROUBLE. AND INSPEC.

Source: SDR FJT00108753
PARTIAL RPM/PWR LOSS · 2000-10-04 Matched by certificate designator
ATA 7210

Part: ENGINE — MALFUNCTIONED (RIGHT)

WHILE ENROUTE STL TO UIN AT ALTITUDE OF 4,000 FT THE RT ENG EG AND TORQUE INSTR BEGAN TO FLUCTUATE. A/C YAWED AND CONT'D TO DO SO. NORMAL PROCEDURES WERE FOLLOWED AND ENGINE REMAINED UNCONTROLLABLE. RT ENGINE WAS SHUT DOWN. CREW DECLARED AN EMERGENCY. A/C LANDED SAFELY AT UIN WITHOUT FURTHER INC. ENGINE RUNS PERFORMED, UNABLE TO DUPLICATE PROBLEM WITH TTL COMPUTER OFF. CREW MEL AND THE TTLAND A/C CONT'D IN SERVICE. ENG/S/C HAS HISTORY OF FALSE TEMP. & TORQUE INDI (9/20 &9/24/00) A/C RET TO STL ENG RUNS & INSP OF INDICATING SYS PERFORMED NO DISCREP NOTED. A/C ARRIVED MQY FROM STL & TTL VALVE REPLACED/MEL CLEARED. A/C WILL RETURN MQY FOR FURTHER TROUBLESHOOTING/INSPEC OF ENG INDIC. SYS.

Source: SDR FJT00108751

1999

FLUID LOSS; WARNING INDICATION · 1999-12-16 Unresolved
ATA 7314

Part: FUEL PUMP — LEAKING (LT ENGINE)

4710 - SAN - LEFT ENGINE FUEL PUMP FILTER BOWL LEAKING FUEL. MAINTENANCE REPLACED LEFT ENGINE FUEL PUMP.

Source: SDR RAIA9912026
FLUID LOSS; WARNING INDICATION · 1999-07-20 Unresolved
ATA 2910

Part: LINE — FAILED (LEFT)

STL - FLT 7504 - BOTH HYDRAULIC PRESSURE GAUGES DROPPED TO ZERO. MAINTENANCE REPLACED LEFT HYDRAULUIC PUMP PRESSURE LINE. (X)

Source: SDR RAIA990723
OTHER · 1999-06-30 Unresolved
ATA 7320

Part: VALVE — FAILED (RT ENGINE)

BMI - FLT 7313 - RIGHT ENGINE EGT FLUX BETWEEN 700 AND 900 DEGREES. MAINTENANCE REPLACED FUEL BYPASS VALVE ON RIGHT ENGINE. (X)

Source: SDR RAIA990649
FLUID LOSS; WARNING INDICATION · 1999-05-11 Unresolved
ATA 2910

Part: LINE — FAILED (RT MLG)

FLT 7394 - STL LOSSED HYDRAULIC PRESSURE ON BOTH SIDES, PERFORMED EMERGENCY GEAR EXTENSION. MAINTENANCE REPLACED RIGHT MAIN LANDING GEAR ACTUATOR LINE. (M)

Source: SDR RAIA990511
OTHER · 1999-04-19 Unresolved
ATA 5720

Part: SCREW — INCORRECT PART (WING TIP)

FLT 7364 - STL - 15 DEGREES HEADING SPLIT. MAINTENANCE REMOVED MAGNETIC SCREWS AND INSTALLED NON-MAGNETIC SCREWS IN BOTH WING TIPS. (M)

Source: SDR RAIA990428

1998

OTHER · 1998-11-23 Unresolved
ATA 3060

Part: DEICE BOOT — FAILED (RIGHT PROP)

FLT 7069 - STL - RIGHT PROP HEAT INOP. MAINTENANCE REPLACED DEICE BOOT ON RIGHT PROP. (M)

Source: SDR RAIA981120
OTHER · 1998-04-01 Unresolved
ATA 3060

Part: BRUSH BLOCK — FAILED (LT PROPELLER)

STL - FLT 7466 - LEFT PROPELLER DEICE FAILED IN-FLIGHT. MAINTENANCE REPLACED LEFT PROPELLER DEICE BRUSH BLOCK. ACFT TT: 12,902.7 HOURS. (X)

Source: SDR RAIA980401
OTHER · 1998-01-07 Unresolved
ATA 3425

Part: HSI — FAILED (RT COCKPIT)

FLT 7396 - STL - FIRST OFFICERS HSI FAILED. MAINTENANCE REPLACED FIRST OFFICERS HSI. (M)

Source: SDR RAIA980106
OTHER · 1998-01-03 Unresolved
ATA 2611

Part: CONNECTOR — INOP (LT ENGINE)

FLT 7344 - STL - LEFT SRL CAPTION ILLUMINATED DURING APPLICATION OF TAKEOFF POWER. MAINTENANCE REPLACED WIRE CONNECTION AT LEFT ENGINE T2 SENSOR. (M)

Source: SDR RAIA980101

1997

FALSE WARNING · 1997-12-02 Unresolved
ATA 2611

Part: DETECTOR — FAILED (BAGG COMPT)

FLT 7204 - FSM CABIN SMOKE LIGHT ILLUMINATED IN FLIGHT. AFTER 5 MINUTES LIGHT EXTINGUISHED. NO OBVIOUS SIGNS OF SMOKE. MAINTENANCE REPLACED AFT BAGGAGE BAY SMOKE DETECTOR. (M)

Source: SDR RAIA971201
FALSE WARNING · 1997-10-26 Unresolved
ATA 2611

Part: SMOKE DETECTOR — FAILED (CARGO COMPT)

FLT 7061 - STL - CARGO SMOKE LIGHT ILLUMINATED. MAINTENANCE REPLACED AFT CARGO SMOKE DETECTOR. (M)

Source: SDR RAIA971017

1996

FALSE WARNING · 1996-12-21 Unresolved
ATA 7722

Part: CONNECTOR — LOOSE (NR 2 ENGINE)

FAT - FLT 4734 - RIGHT SRL CAPTION LIGHT CAME ON. MAINTENANCE RESECURED T2 SENSOR CANNON PLUG. (M)

Source: SDR RAIA961280
OTHER · 1996-10-05 Unresolved
ATA 7510

Part: BLEED GASKET — LEAKS (LT ENGINE)

FAT - FLT 4734 - LEFT ENGINE BYPASSED AT 60 PERCENT TORQUE, EGT SPIKED SEVERAL TIMES DURING REDUCTION. MAINTENANCE REPLACED THE LEFT ENGINE ANTI-ICE VALVE BLEED AIR GASKETS. (M)

Source: SDR RAIA961007
FALSE WARNING · 1996-01-25 Unresolved
ATA 5270

Part: SWITCH — DIRTY (POD DOOR)

MSN - FLT NR 7171 - POD DOOR LIGHT ILLUMINATED AFTER TAKEOFF. MAINTENANCE PLACED ON DMI 52-1. MAINTENANCE LATER CLEARED DMI BY CLEANING MICRO-SWITCH, OPERATION CHECK GOOD. (M)

Source: SDR RAIA960146
NO WARNING INDICATION · 1996-01-21 Unresolved
ATA 6140

Part: CAP LIGHT — MALFUNCTIONED (LEFT)

STL - FLT 7372 - LEFT REVERSE CAP LIGHT WOULD NOT EXTINGUISH. MAINTENANCE DEFERRED REV CAP LIGHT PER MEL. MAINTENANCE CLEARED DMI, PERFORMED OPERATIONAL CHECK REVERSE CAP LIGHT, OPS CHECKED GOOD DURING ROUND RUN. (X)

Source: SDR RAIA960135

1995

OTHER · 1995-11-18 Unresolved
ATA 7530

Part: GASKET — LEAKING (NR 1 ENG)

CMI - FLT 7439 - LEFT FUEL CAPTION AND LEFT BETA LIGHT ILLUMINATED ON TAKEOFF. REPLACED BLEED AIR PORT GASKET. (M)

Source: SDR RAIA951126
FLAME/FIRE · 1995-08-11 Unresolved
ATA 3244

Part: TIRE — FIRE (LT MLG)

STL - FLT NR 7104 - LEFT MAIN TIRE FIRE ON TAKEOFF. MAINTENANCE INSPECTED LEFT MAIN WHEEL WELL, PERFORMED DETAILED VISUAL INSPECTION OF STRUT, WING. REPLACED LEFT MAIN WHEEL, BRAKE AND MAXARET. OPERATION AND LEAK CHECK OK. (M)

Source: SDR RAIA950817
OTHER · 1995-08-09 Unresolved
ATA 3240

Part: BRAKE — REQ'D SERVICE (LT/RT MLG)

STL - FLT NR 7036 - BRAKES WEAK AT HIGH SPEED PEDAL FIRM BUT BRAKES APPEAR WEAK. MAINTENANCE INSPECTED BRAKES AND BLED BOTH BRAKES. TAXI CHECK GOOD. (M)

Source: SDR RAIA950816
FALSE WARNING · 1995-06-23 Unresolved
ATA 6140

Part: SWITCH — FAILED (RT ENGINE)

STL - FLT 7498 - RIGHT BETA LIGHT ILLUMINATED. MAINTENANCE REPLACED RIGHT BETA LIGHT SWITCH. (X)

Source: SDR RAIA950633