N876CA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

39 reports on file, 2011-10-05 – 2017-06-16.

OTHER · 2017-06-16 Matched by certificate designator
ATA 5330

Part: SKIN — DENTED (BS 690) · airframe 40,158 hrs · 44,024 cycles

AFT FUSELAGE BS 690, STRINGER 25R, A LARGE DENTED DAMAGE CUT OUT AND REPAIRED.

Source: SDR JJBA20170616016
OTHER · 2017-02-13 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (EMERGENCY LIGHTS) · airframe 39,778 hrs · 43,592 cycles

EMERGENCY EXIT LIGHT AT ROWS 10 AND 20 INOPERATIVE. REMOVED AND REPLACED THE BATTERIES. OPS CHECKED GOOD.

Source: SDR JJBA20170213010
WARNING INDICATION · 2017-02-03 Matched by certificate designator
ATA 2913

Part: PUMP — INOPERATIVE (HYD SYSTEM) · airframe 39,755 hrs · 43,568 cycles

NR 1 HYD PRESSURE AND NR 1 HYD STANDBY PRESSURE READS ZERO. QUANTITY READS 2 QUARTS. FOUND CASE DRAIN TUBE ASSY LEAKING. R & R DRAIN TUBE LEAK & OPS CHECKED. EDP INSPECTED. R & R EDP CASE DRAIN TUBE, FAILED OPS CHECK. R & R CASE DRAIN FILTER. R & R THE EDP OPS CHECK FAILED. HYD PRESSURE AT ZERO. R & R EDP PRESSURE TUBE, EDP LEAK CHECKED, OPS CHECKED FAILED. R & R NR 1 EDP DUE TO CAVITATION. OPS & LEAK CHECKED GOOD. BLED HYD SYS, NO AIR IN THE SYSTEM. HYD PRESSURE READS NORMAL NO CAUTION LIGHTS.

Source: SDR JJBA20170203006
Earlier reports · 2011–2016 · 36 reports

2016

OTHER · 2016-12-23 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHTS) · airframe 39,547 hrs · 43,327 cycles

CENTER OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. R & R EMERGENCY LIGHT BULB. OPS CHECKED GOOD.

Source: SDR JJBA20161223019
FALSE WARNING · 2016-11-12 Matched by certificate designator
ATA 2612

Part: FIRE LOOP — INOPERATIVE (NR 2 NACELLE) · airframe 39,332 hrs · 43,083 cycles

NR 2 ENGINE FIRE DETECTION FAULT B ILLUMINATED. R & R THE NR 2 FIRE LOOP. OPS CHECKED GOOD. NO DEFECTS NOTED.

Source: SDR JJBA20161112017
WARNING INDICATION · 2016-11-10 Matched by certificate designator
ATA 2913

Part: PUMP — INOPERATIVE (HYD SYSTEM) · airframe 39,322 hrs · 43,074 cycles

NR 2 HYD PUMP CAUTION ILLUMINATED IN FLIGHT. R & R NR 2 EDP. OPS & LEAK CHECKED GOOD. LEFT AND NOSE DOORS REMAINED OPEN DURING RETRACTION. BLED AIR FROM HYD SYSTEMS 1 & 2. PERFORMED GEAR SWING. OPS & LEAK CHECKED GOOD. THE GEAR PINS WHERE INSTALLED. RETURN TO FIELD.

Source: SDR JJBA20161110013
OTHER · 2016-10-10 Matched by certificate designator
ATA 3350

Part: CIRCUIT BOARD — INOPERATIVE (EMERGENCY LIGHTS) · airframe 39,204 hrs · 42,938 cycles

2D & 18D EMERGENCY LIGHT WILL NOT EXTINGUISH. R & R THE PRINTED CIRCUIT BOARD FOR EMERGENCY LIGHT CONTROL BOX. OPS CHECK SAT.

Source: SDR JJBA20161010012
OTHER · 2016-10-06 Matched by certificate designator
ATA 5100

Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 39,194 hrs · 42,925 cycles

POSSIBLE SMOKE WITH FUEL LEAK NR 1 ENGINE NACELLE DRAIN. PERFORMED THREE ENGINE RUNS FOR 20 MINUTES EACH WITH NO LEAKS NOTED.

Source: SDR JJBA20161006009

2015

FALSE WARNING · 2015-11-14 Matched by certificate designator
ATA 2130

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 37,903 hrs · 41,517 cycles

CABIN PRESS LIGHT ILLUMINATED IN FLIGHT. PERFORMED CABIN PRESS OPERATIONS CHECK. OPERATIONS CHECK WAS SATISFACTORY.

Source: SDR JJBA20151210007
OTHER · 2015-04-02 Matched by certificate designator
ATA 3350

Part: SWITCH — DEFECTIVE (CABIN) · airframe 36,565 hrs · 40,044 cycles

EMERGENCY LIGHTS NOT ILLUMINATED GREEN ON FLIGHT ATTENDANTS PANEL. RELAMPED SWITCH.

Source: SDR JJBA20150402001
OTHER · 2015-02-20 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 36,298 hrs · 39,791 cycles

EMERGENCY ESCAPE PATH PHOTO LUMINESCENT STRIPS NOT ILLUMINATING. R & R CABIN OVERHEAD & SIDEWALL LIGHTS.

Source: SDR JJBA20150220006
FLT CONT AFFECTED · 2015-01-22 Matched by certificate designator
ATA 2700

Part: FLT CONTROLS — STIFF · airframe 36,169 hrs · 39,644 cycles

FLIGHT CONTROLS ARE ABNORMALLY STIFF & RESISTANT TO PITCH & ROLL IN FLIGHT. PERFORMED CABLE TENSION CHECKS, NO DEFAULT FOUND. OPERATIONS CHECK FLIGHT IS REQUIRED.

Source: SDR JJBA20150122010
OTHER · 2015-01-10 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN) · airframe 36,116 hrs · 39,585 cycles

EMERGENCY LIGHTS STAY ON WHEN SELECTED TO OFF. REPAIRED BROKEN WIRES 33518GG221 & 3518G22.

Source: SDR JJBA20150110007

2014

NO TEST · 2014-11-19 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (EXTERIOR) · airframe 35,850 hrs · 39,315 cycles

RIGHT AFT EXT EMER LIGHT INOPERABLE. R & R BULB.

Source: SDR JJBA20141119009
NO TEST · 2014-11-19 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (EXTERIOR) · airframe 35,850 hrs · 39,315 cycles

LEFT AFT EXT EMER LIGHT INOPERABLE. R & R BULB.

Source: SDR JJBA20141119008
OTHER · 2014-11-13 Matched by certificate designator
ATA 3040

Part: CONTROLLER — FAULTY (WINDOW HEAT) · airframe 35,819 hrs · 39,284 cycles

FIRST OFFICER`S WINDSHIELD HEAT CB POPPED IN FLIGHT. R & R WINDSHIELD TEMPERATURE CONTROLLER.

Source: SDR JJBA20141113007
OTHER · 2014-05-27 Matched by certificate designator
ATA 3240

Part: LINE — DAMAGED (NR 1 BRAKE) · airframe 34,824 hrs · 38,291 cycles

LOST NR 2 HYD PRESS. R & R NR 1 BRAKE LINE. SERVICED NR 2 HYD.

Source: SDR JJBA20140527011
NO TEST · 2014-02-11 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 34,237 hrs · 37,663 cycles

LEFT AFT EGRESS LIGHT INOPERABLE. R & R BULB.

Source: SDR JJBA20140211007

2013

OTHER · 2013-09-13 Matched by certificate designator
ATA 7500

Part: DUCT — DISCONNECTED (BLEED AIR) · airframe 33,682 hrs · 36,986 cycles

RAPID DECOMPRESSION ON CRUISE AT FLIGHT LEVEL 19,000. SYS AUTO AND MANUAL MODES INOPERATIVE. FOUND BLEED AIR DUCT DISCONNECTED BY AFT RECIRCULATION FAN, RECONNECTED AND OPS CHECKED GOOD.

Source: SDR JJBA20130913007
NO TEST · 2013-07-17 Matched by certificate designator
ATA 3350

Part: BATTERY — INOPERATIVE (EMERGENCY LIGHT) · airframe 33,348 hrs · 36,636 cycles

TWO EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY BATTERY FOR FWD MOST EMERGENCY FLOOR LIGHTING STRIP IRW AMM 33-51-05. NO DEFECTS NOTED, OPS CHECKED SATISFACTORY.

Source: SDR JJBA20130717012
NO TEST · 2013-07-13 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (EMERGENCY LIGHTS) · airframe 33,321 hrs · 36,606 cycles

TWO EMERGENCY RED FLOOR LIGHTS AT ROW 1 INOPERATIVE. REPAIRED BROKEN WIRE. OPS CHECKED SATISFACTORY.

Source: SDR JJBA20130713009

2012

WARNING INDICATION · 2012-11-27 Matched by certificate designator
ATA 7320

Part: FCU — DEACTIVATED (ENGINE) · airframe 32,034 hrs · 35,134 cycles

DURING APPROACH NR 2 PROP RPM DROPPED SUDDENLY. GROUND MX CREW R & R THE FCU. AN OPS AND LEAK CHECK PRODUCED SATISFACTORY RESULTS.

Source: SDR JJBA20121127011
NO TEST · 2012-11-09 Matched by certificate designator
ATA 3350

Part: LIGHT — MALFUNCTIONED (CABIN) · airframe 31,936 hrs · 35,021 cycles

DURING PRE-FLIGHT CREW NOTICED THE NR 2 & NR 3 EMERGENCY LIGHTS DID NOT ILLUMINATE WHEN TESTED. GROUND MX CREW SWAPPED THE P2 AND P3 EMERGENCY LIGHT BATTERIES AND PERFORMED AN OPS CHECK WHICH PRODUCED SATISFACTORY RESULTS. THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20121109005
NO TEST · 2012-10-26 Matched by certificate designator
ATA 3350

Part: BATTERY — UNSECURE (EMERGENCY LIGHT) · airframe 31,885 hrs · 34,957 cycles

DURING PRE FLIGHT, CREW NOTICED THE FORWARD RT EMERGENCY EXIT SIGN WAS NOT ILLUMINATING DURING A TEST. GROUND MX CREW RE SEATED THE EMERGENCY LIGHT BATTERY AND CONDUCTED AN OPS CHECK WHICH PRODUCED SATISFACTORY RESULTS. ACFT RETURNED TO SERVICE.

Source: SDR JJBA20121026006
WARNING INDICATION · 2012-10-18 Matched by certificate designator
ATA 3231

Part: BELLCRANK — BROKEN (MLG DOORS) · airframe 31,840 hrs · 34,900 cycles

DURING APPROACH, WHEN THE THE LANDING GEAR WAS LOWERED, RECEIVED A WARNING INDICATION THAT THE NLG DOORS FAILED TO CLOSE. DECLARED AN EMERGENCY AND WAS ABLE TO LAND SAFELY WITHOUT FURTHER INCIDENT. GROUND MX FOUND THE NLG DOOR BELLCRANK BROKEN. MX R & R THE BROKEN BELLCRANK. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20121018004
NO TEST · 2012-10-03 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 31,745 hrs · 34,786 cycles

DURING PREFLIGHT, CREW NOTICED THAT TWO OVERHEAD EMERGENCY LIGHTS WERE NOT OPERATING. GROUND MX CREW REPLACED THE EMERGENCY LIGHT BATTERIES AT PS4 AND PS6. AN OPS CHECK PRODUCED SATISFACTORY RESULTS AND THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20121003001
OTHER · 2012-07-17 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (FUSELAGE) · airframe 31,359 hrs · 34,345 cycles

ON LANDING, THE CREW OBSERVED THE TOUCHED RUNWAY LIGHT ILLUMINATE. THE CREW NOTIFIED MX OF THE ILLUMINATED LIGHT. GROUND MX CREW INSPECTED ACFT AND FOUND DAMAGE TO THE TAIL BUMPER AREA. THE ACFT WAS REMOVED FROM SERVICE IMMEDIATELY. THE FDR WAS ANALYZED AND CONFIRMED THAT A TAIL STRIKE DID OCCUR. GROUND MX PERFORMED A HARD LANDING INSPECTION, A TOUCHED RUNWAY INSPECTION, AND MADE SKIN REPAIRS TO THE TAIL BUMPER SECTION OF THE ACFT. ONCE ALL INSPECTIONS AND REPAIRS WERE SATISFACTORY THE ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20120717013
NO TEST · 2012-02-20 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — FAILED (EMERGENCY LIGHTS) · airframe 30,521 hrs · 33,375 cycles

FLIGHT CREW DICOVERED 2 EMERGENCY LIGHTS IN THE CEILING WOULD NOT TEST DURING GROUND TEST PRIOR TO LOADING PASSENGERS. OUT STATION MX PERFORMED AN OPS TEST OF THE SYS AND IT TESTED SATISFACTORY. ACFT WAS RETURNED TO SERVICE.

Source: SDR JJBA20120220001
NO TEST · 2012-02-17 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT) · airframe 30,509 hrs · 33,362 cycles

DURING THE PRE-FLIGHT INSPECTION, AIRCREW NOTICED THAT 2 CEILING EMERGENCY LIGHTS WERE INOPERATIVE. R & R THE PS-6 EMERGENCY BATTERY PACK. AN OPS CHECK WAS PERFORMED ON THE EMERGENCY LIGHTING SYS WITH A SATISFACTORY RESULT. ACFT WAS RELEASED TO FLIGHT STATUS.

Source: SDR JJBA20120217001
NO TEST · 2012-02-17 Matched by certificate designator
ATA 3350

Part: BULB — LOOSE (EMERGENCY LIGHT) · airframe 30,509 hrs · 33,362 cycles

DURING THE PRE-FLIGHT INSPECTION, FLIGHT CREW NOTICED THAT 2 OF THE CEILING EMERGENCY LIGHTS WERE INOPERATIVE. MX RESEATED THE CEILING EMERGENCY LAMPS AND PERFORMED AN OPS CHECK OF THE EMERGENCY LIGHTING SYS. OPS CHECK OF EMERGENCY LIGHTING SYS WAS FOUND TO BE SATISFACTORY. ACFT WAS RELEASED TO FLIGHT STATUS.

Source: SDR JJBA20120217002
NO TEST · 2012-02-08 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 30,455 hrs · 33,302 cycles

DURING PRE-FLIGHT INSPECTION, FLIGHT CREW NOTICED THAT THE EMERGENCY LIGHTING SYS FORWARD AND MID CEILING ISLE LIGHTS WERE INOPERATIVE. GROUND MX CREW R & R EMERGENCY LIGHTING POWER SUPPLY PS-6. PERFORMED OPS CHECK OF EMERGENCY LIGHTING SYS, OPS CHECKED SATISFACTORY. ACFT RELEASED TO FLIGHT STATUS.

Source: SDR JJBA20120208004
NO TEST · 2012-02-07 Matched by certificate designator
ATA 3350

Part: BULB — OUT OF ADJUST (EMERGENCY LIGHT) · airframe 30,451 hrs · 33,298 cycles

DURING PRE-FLIGHT INSPECTION FLIGHT CREW NOTICED THAT THE CEILING EMERGENCY LIGHTS AT ROWS 3 AND 6 WERE INOPERATIVE. GROUND MX CREW READJUSTED BULBS AT CEILING EMERGENCY LIGHTS AT ROWS 3 AND 6, CHARGED THE EMERGENCY LIGHTING SYS AND PERFORMED OPS CHECKS ON EMERGENCY LIGHTS. SYS CHECKED SATISFACTORY, ACFT RELEASED TO FLIGHT STATUS.

Source: SDR JJBA20120208001
NO TEST · 2012-01-25 Matched by certificate designator
ATA 3350

Part: BULB — INOPERATIVE (EMERGENCY LIGHT) · airframe 30,375 hrs · 33,217 cycles

DURING PRE-FLIGHT INSP, AIRCREW NOTICED THE NR2 AND NR3 OVERHEAD LIGHTS INOPERATIVE DURING EMERGENCY LIGHTS CHECKS. GROUND MX CREW REPLACED THE LIGHT BULBS FOR THE NR2 AND NR3 LIGHT ASSEMBLIES, PERFORMED EMERGENCY LIGHTS CHECKS. SYS CHECKED SATISFACTORY. ACFT RETURNED TO FLIGHT STATUS.

Source: SDR JJBA2012012987601
NO TEST · 2012-01-19 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 100) · airframe 30,346 hrs · 33,185 cycles

EMERGENCY LIGHT STRIP IN ROW 1 WAS FOUND INOPERATIVE DURING A PRE-FLIGHT INSP BY AIRCREW. GROUND MX CREW REPLACED THE LIGHT STRIP, PERFORMED OPS CHECKS AND FOUND TO BE SATISFACTORY. ACFT RETURNED TO FLIGHT STATUS.

Source: SDR JJBA2012011910201
NO TEST · 2012-01-11 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 30,299 hrs · 33,137 cycles

DURING PRE-FLIGHT INSPECTION, AIRCREW NOTICED THE MIDDLE 2 CEILING EMERGENCY LIGHTS INOPERATIVE WHILE PERFORMING EMERGENCY LIGHT CHECKS. GROUND MX CREW REPLACED BOTH LIGHT BULBS, PERFORMED OPS CHECKS, AND SYS CHECKED SATISFACTORY. ACFT WAS RELEASED TO FLIGHT STATUS.

Source: SDR JJBA2012011210001
NO TEST · 2012-01-05 Matched by certificate designator
ATA 3350

Part: CONNECTOR — UNSECURE (EMERGENCY LIGHTS) · airframe 30,263 hrs · 33,100 cycles

2 RED LIGHTS AT ROW 1 EMERGENCY EXIT LIGHT STRIP INOPERATIVE. RESECURED CONNECTORS. OPS CHECK SATISFACTORY.

Source: SDR JJBA2012010600001

2011

NO TEST · 2011-12-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT) · airframe 30,126 hrs · 32,946 cycles

FLIGHT CREW REPORTED, THAT THE EMERGENCY CEILING LIGHTS ARE NOT WORKING. MX CREW R & R BATTERY PACKS PERFORMED OPS CHECKED SATISFACTORY.

Source: SDR JJBA2011121300001
NO TEST · 2011-10-10 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — FAILED (EMERGENCY LIGHT) · airframe 29,810 hrs · 32,598 cycles

DURING A "L" CHECK, MX CREW FOUND RT FORWARD EGRESS LIGHT NOT WORKING. R & R BATTERY PERFORMED OPS CHECK SATISFACTORY.

Source: SDR JJBA20111010001
NO TEST · 2011-10-05 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 29,774 hrs · 32,560 cycles

FLIGHT CREW REPORTED THE FORWARD EMERGENCY CEILING LIGHTS ARE NOT ILLUMINATING. MX CREW R & R BATTERY PACK PERFORMED OPS CHECK SATISFACTORY.

Source: SDR JJBA20111005001