N877DA

PIPER PA-28-140 · 1969 · Fixed-wing single-engine · 1 engine · 4 seats · Valid Registration

Registered owner: WEST PRAIRIE AIRCRAFT LLC, AR (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

9 reports on file, 2002-07-24 – 2004-08-04.

WARNING INDICATION · 2004-08-04 Matched by certificate designator
ATA 2821

Part: FILTER — CONTAMINATED (NR 2 ENGINE) · airframe 10,383 hrs · 1,624 cycles

ON TAKEOFF EICAS ENGINE FUEL FILTER RT, WHEN PWR REDUCED LIGHT WENT OUT AND REMAINED OUT. ALL OTHER ENG IND NORMAL. FOUND MAINT MSG 73-90122 LP FUEL FILTER ELEMENT RT ENGINE IS BLOCKED. REPLACED RT ENGINE LP FUEL FILTER AS PER MM. PERFORMED FUEL AND OIL LEAK TEST, TEST NR 2 AND ALL CHECKS NORMAL.

Source: SDR DL777040720
WARNING INDICATION · 2004-08-03 Matched by certificate designator
ATA 7330

Part: FILTER — CONTAMINATED (NR 1 ENGINE) · airframe 10,373 hrs · 1,622 cycles

EICAS MSG ENGINE FUEL FILTER LT OCCURRED INTERMITT, EICAS MSG ENGINE FUEL FILTER LT OCCURRED MOMENTARILY DURING CLIMBOUT. T/S PER FIM 73-11 TASK 801. REPLACED LT ENGINE FUEL FILTER PER MM. RAN ENGINE, LEAK CHECK GOOD.

Source: SDR DL777040721
WARNING INDICATION · 2004-03-05 Matched by certificate designator
ATA 3810

Part: VALVE — FAILED (WATER PRESSURE) · airframe 8,286 hrs · 1,324 cycles

CREW REPORTS LOSS OF WATER PRESSURE IN CABIN, DIVERTING TO JFK FOR REPAIRS. INSPECTED ALL WATER AND AIR PRESSURE LINES AT WATER TANKS AND VERIFIED ALL VALVES CLOSED. NO LEAKS. CKD AIR COMP AND VERIFIED GOOD AIR PRESS. FOUND AIR COMP CHECK VALVE STUCK OPEN AND VERY LOW AIR PRESS AFTER PRESS REGULATOR WITH APU AIR ON. RECOMMEND REPLACE CHECK VLV/IN-LINE FILTER AND PRESSURE REG FWD POTABLE WATER SYS TO MCO AND PLACARD PER MEL 38-10-01B WATER SYSTEM DRAINED. MTC REMOVED AND REPLACED CHECK VLV SYSTEM, CHECKS OK.

Source: SDR DL777040217
SMOKE/FUMES/ODORS/SPARKS · 2003-09-24 Matched by certificate designator
ATA 2530

Part: CHILLER — ODOR (AFT GALLEY) · airframe 6,302 hrs · 1,026 cycles

DURING FLT ELECTRICAL ODOR IN CHILLERS ON THE RT SIDE OF AFT GALLEY. CHILLERS TURNED OFF AND ODOR DISSIPATED. NOTE THE AFT GALLEY HEATER WAS TURNED ON PRIOR TO THE ODOR BEING NOTICED/REPLACED A3 RT AFT CHILLER.

Source: SDR DL777030868
SMOKE/FUMES/ODORS/SPARKS · 2003-09-24 Matched by certificate designator
ATA 2530

Part: CHILLER — ODOR (A3 GALLEY) · airframe 6,302 hrs · 1,026 cycles

ELECTRICAL ODOR FROM AFT GALLEY CHILLERS. REMOVED AND REPLACED A3 CHILLER.

Source: SDR DL777030873
WARNING INDICATION · 2003-07-12 Matched by certificate designator
ATA 3610

Part: CONTROLLER — MALFUNCTIONED (NR 2 ENGINE) · airframe 5,318 hrs · 877 cycles

ENROUTE, BLEED OFF LT ENG EICAS MSG ILLUMINATED, REPLACED THE LEFT HIGH PRESSURE FAN AIR CONTROLLER AND THE LEFT MANIFOLD DUAL TEMP SENSOR (M36004). RAN THE ENGINE AT HIGH POWER ALL CHECKS WERE NORMAL. ETOPS CATEGORY 'B': DIVERSION OR TURNBACK.

Source: SDR DL777030635
FALSE WARNING · 2003-07-12 Matched by certificate designator
ATA 3620

Part: SENSOR — FAULTY (BLEED AIR SYS) · airframe 5,318 hrs · 877 cycles

CREW REPORTS BLEED OFF ENG L MESSAGE RESET AND TRIPPED AGAIN APPROX 40 MINUTES LATER. A/C RETURNING TO ATL FOUND MAINT MESSAGE 36-10500. MANIFOLD DUAL TEMP SENSOR LEFT FAILED. REPLACED SAME PER M/M. RAN ENGINE TO POWER AND ALS PERFORMED ENGINE BLEED AIR OPERATIONAL TEST PER M/M. NO MESSAGES. OPS CK GOOD. ETOPS CATEGORY 'B': DIVERSION OR TURNBACK.

Source: SDR DL777030632
NO TEST · 2002-08-05 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — UNSERVICEABLE (CABIN) · airframe 1,306 hrs · 222 cycles

AFT GALLEY EMERGENCY LIGHTS INOP. FOUND POWER SUPPLY BAD. REPLACED POWER SUPPLY.

Source: SDR DL777020908
FALSE WARNING · 2002-07-24 Matched by certificate designator
ATA 3150

Part: WARNING SYSTEM — FALSE ACTIVATION (COCKPIT) · airframe 1,167 hrs · 200 cycles

ON DESCENT PASSING FL270 AFT CARGO HEAT LIGHT CAME ON ALONG WITH THE FOLLOWING STATUS MSG. ELMS P110 PANELÂ¥ IFE COOLING FAN EQUIPMENT VENT FAN AIR/GND LÂ¥ L AND R RECIRC FAN. T/S PER FIM MAINT MSG FAULT CODE 24-18801. PERFORMED ELMS P110 EU INITIALIZE SELF TEST. TEST PASSED. ALL MSG CLEARED AND SHOWN NOT ACTIVE ON MAT.

Source: SDR DL777020880