N885AA

EXTRA FLUGZEUGBAU GMBH EA-400 · 2001 · Fixed-wing single-engine · 1 engine · 2 seats · Valid Registration

Registered owner: MACHEN36 LLC, DE (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

74 reports on file, 1995-01-30 – 2001-08-23.

NO TEST · 2001-08-23 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (AFT AIRSTAIRS)

TUL - FOUND VENTRAL STAIRS EMERGENCY LIGHT INOPERATIVE. INSTALLED SERVICEABLE VENTRAL STAIRS EMERGENCY LIGHT PER MM 33-50-061-4 PAGE 403, REPAIRED ON E-58 4012889. (M)

Source: SDR AALA20011700
OTHER · 2001-08-19 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (FUSELAGE)

TUL - FOUND CORROSION ALONG LINE STATION 1140 FROM APPROX 24 INCHES RBL TO 36 INCHES RBL SEVERAL AREAS. CUTOUT DAMAGED AREA AND INSTALLED WEB REPAIR PER SRM 51-40-2 PAGES 1-6. (M)

Source: SDR AALA20011667
OTHER · 2001-08-18 Matched by certificate designator
ATA 5712

Part: RIB — CRACKED (WING)

TUL - FOUND STATION 760 RIB CHORD CRACKED BEHIND 760 RIGHT FRAME. STOP DRILLED CRACK. INSTALLED REPAIR DOUBLERS 760 RBL 70.5 IAW SB 727-57-0112 AS EPR CARD 4258 PAGE 2 ITEM 9. (M)

Source: SDR AALA20011666
OTHER · 2001-08-17 Matched by certificate designator
ATA 5330

Part: SKIN

TUL - FOUND BULGE ABOVE LEFT RAM AIR DOOR MIDWAY ALONG LEFT EDGE OF CUTOUT. REMOVED CORROSION AND INSTALLED .080 17-7 PH DOUBLER PER ESO 11697 DATED 8/15/2001. (M)

Source: SDR AALA20011665
OTHER · 2001-08-16 Matched by certificate designator
ATA 2700

Part: SKIN — CORRODED (BS 115)

TUL - FOUND CORROSION UPPER RIGHT HORIZONTAL STAB SKIN T/E BEAM 4 HINGE IN FROM STAB TIP AT ABOUT STAB STATION 115. REPAIRED CORROSION AREA AS PER ESO 11697 DATED 8-16-2001. (M)

Source: SDR AALA20011663
OTHER · 2001-08-16 Matched by certificate designator
ATA 5510

Part: BEAM — CORRODED (HORIZ STAB)

TUL - FOUND CORROSION UPPER RIGHT HORIZONTAL T/E BEAM 3RD ELEVATOR HINGE IN FROM TIP. REPAIRED CORROSION AREA AS PER ESO 11697, 8-16-2001. (M)

Source: SDR AALA20011662
OTHER · 2001-08-14 Matched by certificate designator
ATA 5730

Part: SKIN — CORRODED (WING)

TUL - FOUND LOWER WING LEADING EDGE SKIN CORRODED AFT OF INBOARD FUEL CAP. INSTALLED DOUBLER PER ESO NR 11697 DATED 8-13-2001. (M)

Source: SDR AALA20011664
NO TEST · 2001-07-02 Matched by certificate designator
ATA 3397

Part: SPLICE — DAMAGED (GALLEY)

DFW - DURING OVERNIGHT MAINTENANCE, FIRST CLASS EMERGENCY EXIT LIGHT AT GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT WIRE SPLICE AT FIRST CLASS GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20011337
NO TEST · 2001-02-28 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (AFT AIRSTAIR)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AFT AIRSTAIR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT AFT AIRSTAIR. SYTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20010351
NO TEST · 2001-02-28 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (ENTRY DOOR)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT MAIN ENTRY DOOR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT LEFT SIDE MAIN ENTRY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20010352
NO TEST · 2001-02-26 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

DFW - FOUND DURING OVERNIGHT MAINTENANCE, FLOOR EMERGENCY EXIT LIGHT DIM AT COACH CLASS. REPAIRED EMERGENCY EXIT LIGHT STRIP AT COACH CLASS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20010342
Earlier reports · 1995–2000 · 63 reports

2000

OTHER · 2000-10-05 Matched by certificate designator
ATA 5313

Part: STRINGER — GOUGED (FUSELAGE)

TUL - FOUND DEEP GOUGE, 1 INCH BY 12 INCHES, IN STRINGER 26L AT STATION 580. REMOVED DAMAGED SECTION OF STRINGER AND REPAIRED USING STRINGER SPLICE PER SRM 53-10-3. (M)

Source: SDR AALA20001675
OTHER · 2000-10-03 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (FUSELAGE)

TUL - FOUND STRINGER 27R CORRODED BETWEEN STATION 500-520. REPAIRED STRINGER 27R PER SRM 53-10-3 AND ESO 11697 DATED 10/2/200. FOUND SKIN OUT OF LIMITS. REPAIRED SKIN WITH .100 7075 PLUS 6 DOUBLER PER SRM 53-30-3. (M)

Source: SDR AALA20001633
OTHER · 2000-10-03 Matched by certificate designator
ATA 5313

Part: STRINGER — SPLIT (FUSELAGE)

TUL - FOUND STRINGER 29R IS SPLIT OPEN DUE TO SEVERE CORROSION, 1 INCH BY 3 INCHES, AT STRINGER T-FITTING ATTACHMENT FS 1178 TO 1181. INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)

Source: SDR AALA20001631
OTHER · 2000-10-02 Matched by certificate designator
ATA 5310

Part: STRUCTURE — CRACKED (FUSELAGE)

TUL - FOUND 2 INCH BY 2 INCHE AREA OF FUSELAGE DENTED/CRACKED BELOW FORWARD LAVATORY SERVICE PANEL STATION 280. INSTALLED REPAIR PER ESO 11697, DATED 29 SEP 00. (M)

Source: SDR AALA20001629
OTHER · 2000-09-27 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (FUSELAGE)

TUL - FOUND 6 INCH BY 2 INCH AND .100 DEEP AREA OF CORROSION ON STRINGER 29R AT STATION 1010. FABRICATED AND INSTALLED 11 INCH SECTION OF NEW STRINGER WITH NEW FORWARD AND AFT SPLICE AS PER SRM 53-10-3. (M)

Source: SDR AALA20001632
NO TEST · 2000-08-09 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (AFT AIRSTAIRS)

DFW DURING OVERNIGHT MAINTENANCE AFT STAIR EMERGENCY LIGHT INOPERATIVE. REPLACED AFT STAIR EMERGENCY LIGHT ASSEMBLY. SYSTEM GROUND CHECK NORMAL OPERATION.

Source: SDR AALA20001320
NO TEST · 2000-04-24 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CARGO BAY)

DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHT AT AFT CARGO DOOR INOPERATIVE. REPLACED EMERGENCY LIGHT AT AFT CARGO DOOR. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20000695

1999

SMOKE/FUMES/ODORS/SPARKS · 1999-08-29 Matched by certificate designator
ATA 3340

Part: LIGHT — FAILED (FUSELAGE)

CCS - FLT 2142 - AFTER TAKEOFF CCS-MIA, FUMES WITH SMELL OF BURNING RUBBER NOTED IN FORWARD AREA OF COACH CABIN. NO VISIBLE SMOKE DETECTED. AIRCRAFT RETURNED TO CCS AND LANDED WITHOUT INCIDENT. SMELL TRACKED TO UPPER FUSELAGE ANTI-COLLISIONS STROBE LIGHT. UPPER FUSELAGE ANTI-COLLISION STROBE LIGHT PLACARDED INOPERATIVE PER MEL. REPLACED UPPER FUSELAGE ANTI-COLLISION STROBE LIGHT AT IAH ON 8/30/99. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA991298

1998

OTHER · 1998-10-09 Matched by certificate designator
ATA 2810

Part: WEB — CRACKED (FUEL CELL)

TUL - FOUND 1.5 INCH CRACK ON CENTER NR 2 TANK AFT WALL UPPER SIDE OF BAFFLING OPENING. STOP DRILLED CRACK. INSTALLED DOUBLER PER SRM 57-10-1. (M)

Source: SDR AALA981944
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — CHAFED (BS 500)

TUL - WEB OF BELL FRAME DAMAGED, HOLE WORN THROUGH, AFT SIDE STATION 500 ABOVE AND INBOARD OF STRINGER 27R. REMOVED DAMAGED AREA, INSTALLED DOUBLER FROM 2024-T3 .063 INCH ADDED .080 SHIM, WITH 18 FASTENERS, BOLTS. 1875 INCH DIAMETER PER SRM SRM 51-40-2. (M)

Source: SDR AALA981982
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 1070)

TUL - STATION 1070 BELL FRAME TOP DENTED ABOVE STRINGER 25L. INSTALLED DOUBLER PER SRM 53-10-4. (M)

Source: SDR AALA981949
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DAMAGED (BS 1010)

TUL - FOUND STATION 1010 BELL FRAME DAMAGED BELOW STRINGER 25L AND 26L. CUT OUT DAMAGED AREAS AND INSTALLED DOUBLER REPAIRS PER AARD 53-10-7-3 AND SRM 51-40-3, 7075-T6 .071 DOUBLER 4 RIVETS EACH SIDE, DAMAGE 2 ROWS RIVETS INWEB .25 INCH AND .1875 INCH D RIVETS. (M)

Source: SDR AALA981980
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 1030)

TUL - FOUND STATION 1030 BELL FRAME DENTED INBOARD STRINGER 26R. CUT OUT DAMAGED AREA. INSTALLED DOUBLER PER SRM 53-10-4. (M)

Source: SDR AALA981954
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 950)

TUL - FRAME DENTED AND WEB BULGED STATION 950B LEFT STRINGER 26L. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER AARD 53-10-07-3. (M)

Source: SDR AALA981951
OTHER · 1998-10-09 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 580)

TUL - FOUND CORROSION ON SKIN STATION 580 BETWEEN STRINGER 27 LEFT TO STRINGER 28 LEFT. REPAIRED DAMAGED AREA WITH EXTENDED REPAIR PER SRM 53-30-3. INSTALLED INTERCOSTALS AS NEEDED CLIP AND OTHER ATTACHING HARDWARE INSTALLED. (M)

Source: SDR AALA981947
OTHER · 1998-10-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 400)

TUL - FLOORBEAM UPPER FLANGE CORRODED STATION 400 RBL 21 TO LBL 21. REMOVED CORROSION, INSTALLED FILLER RBL 2 TO 4.5, INSTALLED REPAIR WITH ANGLE ON BOTH SIDES OF FLOORBEAM. (M)

Source: SDR AALA981959
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 600)

TUL - FOUND BELL FRAME SPLICE DENTED STATION 600 BETWEEN STRINGER 26 LEFT - 25 RT. INSTALLED 8 INCH DOUBLER 7075 T-6 .063 WITH 20 .1875 MS20470DD RIVETS, 2 ROWS PAST DAMAGE, 1 ROW ON TOP, .75 SPACING PER 51-40-3 FIG 1 PAGE 3. (M)

Source: SDR AALA981972
OTHER · 1998-10-09 Matched by certificate designator
ATA 5313

Part: STRINGER — CRACKED (BS 720)

TUL - STRINGER 15L CRACKED IN TWO PLACES AT FASTENERS, STATION 720B PLUS 16 INCHES, AFT OF ICE LIGHT. REMOVED DAMAGED AREA OF STRINGER 15L, AFT OF ICE LIGHT STATION 720C. REPAIRED WITH STRINGER SPLICE PER SRM 53-10-3 DETAIL 2. (M)

Source: SDR AALA981956
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 600)

TUL - BELL FRAME DENTED STATION 600 ABOVE STRINGER 23 LEFT. INSTALLED 7.5 INCH DOUBLER .063 7075 T-6 WITH 21 .1875 MS20470DD RIVETS, 2 ROWS PAST DAMAGE, 1 ROW ON TOP .75 SPACING PER SRM 51-40-3 FIG 1 PAGE 3. (M)

Source: SDR AALA981971
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 990)

TUL - FOUND STATION 990 BELL FRAME DENTED ABOVE STRINGER 25L-26L. CUT OUT DAMAGED AREAS OF BELL FRAME. INSTALLED DOUBLER REPAIR PER AARD 53-10-7-3. (M)

Source: SDR AALA981950
OTHER · 1998-10-09 Matched by certificate designator
ATA 5315

Part: STRINGER — CRACKED (BS 720)

TUL - STRINGER 15R CRACKED AT STATIO N720B PLUS 4 INCH JUST FORWARD OF ICE LIGHT. INSTALLED REPAIR TO STRINGER 15R AT STATION 720B PER SRM 53-10-3 FIGURE 5. (M)

Source: SDR AALA981955
OTHER · 1998-10-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 380)

TUL - TOP OF FLOORBEAM CORRODED OUT OF LIMITS RBL 49 TO RBL 71. REPAIRED 380 FLOORBEAM PER SRM 53-10-08 WITH FILLER ON TOP WHERE CUT OUT AND AN ANGLE ON BOTH SIDES OF FLOORBEAM. (M)

Source: SDR AALA981961
OTHER · 1998-10-09 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 1166)

TUL - STATION 1166 BELL FRAME SHEAR TIE CORRODED AFT SIDE OUTBOARD OF STRINGER 29. REMOVED AND REPLACED CORRODED SHEAR TIE PER SRM 51-10-1 PAGE 4. (M)

Source: SDR AALA981979
OTHER · 1998-10-09 Matched by certificate designator
ATA 5320

Part: STIFFENER — CRACKED (BS 1384)

TUL - VERTICAL STIFFENER AT STATION 1384 LBL 8 INCHES ABOVE PANEL 5201 AND ABOVE NR 2 ENGINE ANGLE BRACKET HAS CRACK. STOP DRILLED CRACK. INSTALLED STAINLESS 301 HALF HARD ANGLE DOUBLER .080 PER SRM 51-40-4. (M)

Source: SDR AALA981967
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 680)

TUL - RIGHT BELL FRAME DENTED STATION 680 ABOVE STRINGER 24 AND ABOVE STRINGER 23. INSTALLED DOUBLER REPAIR PER SRM 51-40-3, 2.5 INCH WIDE, 1 INCH DEEP, 17 INCH IN LENGTH, TWO ROWS RIVETS ON SIDE, ONE ROW TOP, 46 EACH .1875 RIVETS TOTAL, MS20470 DD6, 2 ROWS PAST DAMAGE, DOUBLER .063 7057-T6. (M)

Source: SDR AALA981968
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 520)

TUL - LEFT BELL FRAME DENTED AND WEB BULGED AT STATION 520 ABOVE STRINGER 24 LEFT. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER .063 INCH 7075-T6 MATERIAL INSTALLED 27 UNIVERSAL HEAD .1875 INCH 'D' RIVETS AND 4 UNIVERSAL HEAD .25 INCH RIVETS PER SRM 51-40-3 PAGE 3 FIG 1. (M)

Source: SDR AALA981974
OTHER · 1998-10-09 Matched by certificate designator
ATA 5510

Part: BEAM — CORRODED (HORIZ STAB)

TUL - FOUND RIGHT STAB T/E BEAM UPPER BEAM HAS CORROSION ON TOP SURFACE ABOVE NR 1 AND NR 2 SUPPORT RIBS. REPAIRED IAW SRM 55-10-1 DETAIL V. (M)

Source: SDR AALA981945
OTHER · 1998-10-09 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 1166)

TUL - STATION 1166 SHEAR TIE CORRODED AFT SIDE BETWEEN STRINGER 29R-30R. REMOVED AND REPLACED CORRODED SHEAR TIE PER SRM 51-10-6, SRM 51-10-1. (M)

Source: SDR AALA981994
OTHER · 1998-10-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 480)

TUL - FLOORBEAM CORRODED ON UPPER FLANGE RBL 24 TO RBL 63 AT STATION 480. REPAIRED PER SRM 53-10-8, WITH APPROX 6 INCHES FILLER ON TOP FLANGE WITH ANGLES ON BOTH SIDES OF BEAM. (M)

Source: SDR AALA981958
OTHER · 1998-10-09 Matched by certificate designator
ATA 3211

Part: FITTING — CORRODED (MLG)

TUL - LEFT TRUNNION CORRODED IN BEARING BORE. INSTALLED NEW LEFT TRUNNION FITTING. (M)

Source: SDR AALA981995
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 500)

TUL - BELL FRAME DENTED AND WEB BULGED STAITON 500 BETWEEN STRINGER 24L TO 23L. INSTALLED DOUBLER REPAIR PER ESO 51-40-3 PAGE 3 FIG 1 USING 7075-T6 .063 INCH MATERIAL, 22 UNIVERSAL HEAD 'D' RIVETS .1875 INCH DIAMETER CUTTING OUT 3 INCH OF THE TOP LEG DAMAGED AREA. (M)

Source: SDR AALA981975
OTHER · 1998-10-09 Matched by certificate designator
ATA 5512

Part: SKIN — CORRODED (HORIZ STABILIZER)

TUL - LEFT STABILIZER UPPER SKIN HAS CORROSION TOP SURFACE ABOVE REAR SPAR. INSTALLED DOUBLER PER SRM 51-10-1 2024T3 .032 AFTER CORROSION WAS REMOVED. (M)

Source: SDR AALA981991
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DAMAGED (BS 1050)

TUL - FOUND STATION 1050 BELL FRAME DAMAGED ABOVE STRINGER 27R. CUT OUT DAMAGED AREA OF BELL FRAME. INSTALLED DOUBLER REPAIR PER SRM 53-10-4. (M)

Source: SDR AALA981953
OTHER · 1998-10-09 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 600)

TUL - FOUND CORROSION ON SHEAR TIE AFT SIDE OF STATION 600, OUTBOARD OF STRINGER 26 LEFT. REMOVED AND REPLACED CORRODED SHEAR TIE, TREATED AND PRIMED AREA PER 51-10-2. (M)

Source: SDR AALA981990
OTHER · 1998-10-09 Matched by certificate designator
ATA 5312

Part: BULKHEAD — CRACKED (BS 303)

TUL - BULKHEAD 303 AT STRINGER 16L, BELOW DOOR STOP CASTING CRACKED. STOP DRILLED CRACK AND INSTALLED DOUBLER PER ESO 11697, DATED 10/2/98. (M)

Source: SDR AALA981962
OTHER · 1998-10-09 Matched by certificate designator
ATA 5730

Part: SKIN — GOUGED (WS 720)

TUL - FOUND GOUGE IN SKIN BELOW STRINGER 22L AT FS 720A BELOW SEALANT. REMOVED DAMAGE, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-30-3 PAGE 5. (M)

Source: SDR AALA981946
OTHER · 1998-10-09 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 950)

REMOVED CORROSION PER SRM 51-10-6, INSTALLED STRAP PER ESO 11697, DATED 9-15-98. (M)

Source: SDR AALA981988
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 500)

TUL - RIGHT BELL FRAME HAS 3 DENTS STATION 500 BETWEEN STRINGER 24 RT AND 22 RT. INSTALLED DOUBLER ON BELL FRAME PER SRM 51-40-3 FIG 1 PAGE 3, 12 INCH BY .050 DOUBLER 7075-T6 WITH 2 ROWS PAST DAMAGE 1 ROW ON TOP, INSTALLED 27 .1875 MS2047DD RIVETS. (M)

Source: SDR AALA981978
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — GOUGED (BS 950)

TUL - BLENDED OUT GOUGE, HPEC, FLAP PEENED, ALODINE, PRIMED, INSTALLED 17 INCH BY 2 INCH L-ANGLE, 17.7PH STAINLESS STEEL .050 INCH. REPAIRED PER ESO 11697, DATED 9/17/98. (M)

Source: SDR AALA981983
OTHER · 1998-10-09 Matched by certificate designator
ATA 5313

Part: STRINGER — CORRODED (BS 1075)

TUL - STRINGER 27L CORRODED AT STATION 1075 CAUSING 2.5 INCH CRACK IN BELLY SKIN. CUT OUT DAMAGED AREA OF SKIN. REMOVED CORROSION FROM STRINGER 27L PER SRM 51-10-6. INSTALLED DOUBLER ON SKIN PER SRM 53-30-3 FIG 3. INSTALLED 'U' CHANNEL REPAIR ON STRINGER 27L PER SRM 53-103 PAGE 4E, FIG 2 SHEET 3. (M)

Source: SDR AALA981986
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — CORRODED (BS 1166)

TUL - STATION 1166 BELL FRAME SHEAR TIE AFT SIDE OUTBOARD OF STRINGER 29 CORRODED. REMOVED CORROSION PER 51-10-6, TREATED, PRIMED CLEANED AND INSTALLED NEW SHEAR TIE 51-10-1 PAGE 4. (M)

Source: SDR AALA981993
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — BENT (BS 950)

TUL - FOUND STATION 950B AND F BELL FRAME TOP BENT WEB BULGED BETWEEN STRINGER 26R AND 25R. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER AARD 53-10-07-3. (M)

Source: SDR AALA981952
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 560)

TUL - BELL FRAME DENTED TOP LEG STATION 560 BETWEEN STRINGER 24 LEFT AND 23 LT. INSTALLED DOUBLER .063 INCH 7075-T6 WITH 18 'D' RIVETS .1875 INCH UNIVERSAL HEAD AND 4 'D' RIVETS .25 INCH UNIVERSAL HEAD PER SRM 51-40-3 PAGE 3 FIG 1. (M)

Source: SDR AALA981973
OTHER · 1998-10-09 Matched by certificate designator
ATA 5320

Part: SHEAR TIE — CORRODED (BS 600)

TUL - FOUND CORROSION ON SHEAR TIE FORWARD SIDE STATION 600 OUTBOARD, STRINGER 26 LEFT. REPLACED SHEAR TIE, TREATED AND PRIMED AREA PER SRM 51-10-2. (M)

Source: SDR AALA981989
OTHER · 1998-10-09 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 495-500)

TUL - FUSELAGE SKIN CORRODED FROM STATION 495 TO STATION 500 FROM STRINGER 28 R TO 27R. REMOVED CORRODED AREAS AND INSTALLED DOUBLER PER SRM 53-30-3 PAGE 12 FIG 3. TREATED AND PRIMED EFFECTED AREAS. (M)

Source: SDR AALA981948
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 680)

TUL - BELL FRAME DENTED BETWEEN STRINGER 23 LEFT AND 22 LEFT. INSTALLED DOUBLER PER SRM 51-40-3 FIG 1 PAGE 3, 9 INCHES IN LENGTH 2.5 INCHES DEEP, 1 INCH WIDE 22 EACH MS20470DD6 RIVETS AT .780 SPACING 2 ROWS PAST DAMAGE, 1 ROW TOP .063 7075T-6 DOUBLER. (M)

Source: SDR AALA981969
OTHER · 1998-10-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — DAMAGED (BS 380)

TUL - REPAIRED 380 FLOORBEAM RBL 7 TO RBL 30 WITH FILLER ON TOP AND ANGLE ON BOTH SIDES PER SRM 53-10-08. (M)

Source: SDR AALA981960
OTHER · 1998-10-09 Matched by certificate designator
ATA 5311

Part: FRAME — DENTED (BS 660)

TUL - LEFT BELL FRAME DENTED STATION 660 BETWEEN STRINGER 25 LT AND 24 LT. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER FROM 7075-T6 .063 INCH THICK, WITH 15 D RIVETS .1875 DIAMETER AREA 4 D RIVETS .25 INCH DIAMETER UNIVERSAL HEAD PER SRM 51-40-3 PAGE 3 FIG 1. (M)

Source: SDR AALA981970
OTHER · 1998-10-09 Matched by certificate designator
ATA 5512

Part: SKIN — CORRODED (HORIZ STABILIZER)

TUL - FOUND RIGHT STAB UPPER SKIN HAS CORROSION, ABOVE REAR SPAR AROUND FASTENERS, TOP SURFACE JUST OUTBOARD UPPER SPAR CAP. REMVOED CORROSION AND INSTALLED DOUBLER PER SRM 51-10-1, 2024-T3 .032. (M)

Source: SDR AALA981992
OTHER · 1998-10-09 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 344)

TUL - FOUND UPPER FLANGE OF FLOORBEAM CORRODED. REMOVED AND REPLACED TOP CHORD OF STATION 344 FROM RBL 6 INCHES TO LBL 67 INCHES. DRILLED HOLES ALODINED AND PRIMED PER SRM 51-10-2 AND REINSTALLED TWO WEB STIFFENERS STATION 344 BL 0 AND RBL 8 PER SRM 53-10-8. (M)

Source: SDR AALA981957
OTHER · 1998-09-29 Matched by certificate designator
ATA 5320

Part: FLOOR PAN — CORRODED (BS 1146-1173)

TUL - EXTENSIVE CORROSION ON FLOOR PAN AT STATION 1146-1173, LBL 16 - RBL 16. CORROSION BEYOND LIMITS PER SRM 51-10-1. INSTALLED NEW FLOOR PAN AT STATION 1146-1173 PER SRM 53-10-1. (M)

Source: SDR AALA981984
OTHER · 1998-09-29 Matched by certificate designator
ATA 5320

Part: CLIP — CRACKED (BS 950)

TUL - FOUND STRINGER CLIP TORN AND CRACKED STATION 950F, STRINGER 3R (LOWER OUTBOARD SIDE). REMOVED TORN AND CRACKED STRINGER CLIP AND REPLACED WITH NEW STRINGER CLIP AT BS 950F, STRINGER 3R. (M)

Source: SDR AALA981976
OTHER · 1998-09-29 Matched by certificate designator
ATA 5311

Part: FRAME — MISDRILLED (BS 360)

TUL - DOUBLER DRILLED HOLE IN BELL FRAME T BS 360 AFT SIDE OF FRAME BELOW STRINGER 2R. REPAIRED BELL FRAME AT BS 360 BELOW STRINGER 2R. REPAIRED BELL FRAME AT BS 360 BELOW STRINGER 2R PER SRM 51-40-2 FIG1. (M)

Source: SDR AALA981981
OTHER · 1998-09-23 Matched by certificate designator
ATA 5320

Part: FLOOR PAN — CORRODED (BS 1130-1134)

TUL - DOUBLER BULGING AT RIGHT AFT LAVATORY FLOOR PAN AREA, INBOARD OF RIGHT INBOARD SEAT TRACK STATION 1130-1134. CUT OUT AREA THAT WAS BEYOND LIMITS WHEN CORROSION WAS REMOVED AT BS 1131-1135 RBL 25-28, INSTALLED DOUBLER AND FILLER PER SRM 51-40-2, ALODINED AND PRIMED. (M)

Source: SDR AALA981987
OTHER · 1998-09-23 Matched by certificate designator
ATA 5320

Part: FLOOR PAN — CORRODED (BS 1130-1173)

TUL - FOUND CORROSION ON RIGHT LAVATORY FLOOR PAN UNDERNEATH HAT CHANNEL, STATION 1130-1173, RBL 21-RBL 28. CUT OUT AREA BEYOND LIMITS AT BS 1167-1174 RBL 23-27. INSTALLED DOUBLER AND FILLER PER SRM 51-40-2 FIG 1. REMOVED OTHER CORROSION WITHIN LIMITS, ALODINED, PRIMED AND PAINTED INSTALLED HAT CHANNEL. (M)

Source: SDR AALA981985
OTHER · 1998-09-16 Matched by certificate designator
ATA 5320

Part: STRAP — CRACKED (BS 930)

TUL - FOUND TIE STRAP CRACKED IN HALF STATION 930, STRINGER 14L. REMOVED AND REPLACED TIE STRAP. (M)

Source: SDR AALA981977

1997

WARNING INDICATION · 1997-12-10 Matched by certificate designator
ATA 3020

Part: DUCT — DEFECTIVE (TAIL COMPARTMENT)

MIA - FLT 2103 - AFTER TAKEOFF MIA DURING CLIMB-OUT, AFT BODY OVERHEAT LIGHT ILLUMINATED. NR 2 ENGINE RETARDED AND LIGHT EXTINGUISHED. AIRCRAFT RETURNED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED CENTER ENGINE FIREWALL THERMO ANTI-ICING DUCT. ACCOMPLISHED GROUND ENGINE RUN WITH NO DEFECTS OR LEAKS NOTED. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA972379
OTHER · 1997-08-27 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 700-712)

TUL - CORROSION IN SKIN LAP UNDER LEVELING COMPOUND STA 700 - STA 712, OUTBOARD SIDE STR 26R. INSTALLED REPAIR DOUBLERS AND FILLER IAW ESO 11697 DATED 8-20-97 AND SEALED. TST: 50,8891. CYCLES: 30,766. (X)

Source: SDR AALA971622
OTHER · 1997-08-27 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 1010)

TUL - CORROSION AT LEVELING COMPOUND (CRACKED AND PEELING) STA 1010, STR 27L. INSTALLED DOUBLER AND FILLER PER SRM 53-30-3, FIGURE 3A. AERODYNAMIC SEAL AND FILLET SEALED WITH BMS-5-95. TST: 50,897. CYCLES: 30,766. (X)

Source: SDR AALA971621
NO TEST · 1997-04-03 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (AFT STAIRS)

RDU - DURING OVERNIGHT CHECK, EMERGENCY LIGHT IN AFT VENTRAL STAIRS INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY IN AFT VENTRAL STAIRS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA970662

1996

OTHER · 1996-09-04 Matched by certificate designator
ATA 5314

Part: KEEL BEAM — CORRODED (BS 800)

TUL - FOUND CORROSION ON BOTTOM O KEEL BEAM STATION 800. REMOVED CORROSION AND INSTALLED WEB REPAIR DOUBLER PER SRM 51-40-2 PAGE 6 AND EDGE SEALED. (M)

Source: SDR AALA961314
OTHER · 1996-09-04 Matched by certificate designator
ATA 5320

Part: ANGLE — CORRODED (BS 365-418)

TUL - FOUND RIGHT CREASE ANGLE CORRODED STATION 365 TO 418. CUT OUT CORRODED CREASE ANGLE AND REPLACED CREASE ANGLE. (M)

Source: SDR AALA961313

1995

NO TEST · 1995-01-30 Matched by certificate designator
ATA 3350

Part: EEL STRIP — DEFECTIVE (CABIN)

DFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHTS UNDER EXIT SIGN INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR LIGHT STRIP. SYSTEM GROUND CHECKS NORMAL OPERATION. (W)

Source: SDR AALA950160