N891UP

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Gama Aviation LLC (O2GA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

3 reports on file, 2018-07-22 – 2025-02-12.

FLT CONT AFFECTED · 2025-02-12 Matched by certificate designator
ATA 6122

Part: GOVERNOR — FAULTY (PROPELLER) · airframe 4,425 hrs · 3,719 cycles

LEFT PROP STUCK AT 1570 RPM IN FLIGHT - EMERGENCY DECLARED - TROUBLESHOOTING ISOLATED TO PROPELLER PRIMARY GOVERNOR. REMOVED LEFT ENG PROP GOVERNOR P/N 8210-310 S/N 20572154, INSTALLED REPAIRED GOVERNOR P/N 8210-310 S/N 11509197 PER P&WC PT6A-60A EMM CHAPT 61- 20-00 AND FIND NORMAL OPS CHECK PER KING AIR B300 FUS AMM CHAPT 76-10-15.

Source: SDR CVGA20250218003
FLT CONT AFFECTED; WARNING INDICATION · 2019-09-19 Matched by certificate designator
ATA 2700

Part: ACTUATOR — LACK OF LUBE (FLIGHT CONTROL) · airframe 913 hrs · 784 cycles

AT ALTITUDE ALL 3 TRIM WHEELS BECAME VERY RIGID AND DIFFICULT TO ROTATE. 'AP HOLDING ND' AND 'MISTRIM' ANNUNCIATOR ILLUMINATED. DIVERTED TO SMF. ON DESCENT TRIM WHEELS FREED UP. MAINTENANCE INSPECTED ELEVATOR, AILERON AND RUDDER TRIM ACTUATORS FOR MOISTURE. NON FOUND. LUBED ACTUATORS AND A SUCCESSFUL OPERATIONAL CHECK FLIGHT WAS PERFORMED. AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR O2GA2019092489101
FLT CONT AFFECTED · 2018-07-22 Matched by certificate designator
ATA 2750

Part: SWITCH — OUT OF ADJUST (TE FLAPS) · airframe 80 hrs · 70 cycles

FLAPS WOULD NOT EXTEND FOR LANDING. PERFORMED NO FLAPS LANDING IAW CHECKLIST. MAINTENANCE ADJUSTED THE LEFT FLAP SAFETY SWITCH. A SUCCESSFUL OPERATIONAL CHECK FLIGHT WAS PERFORMED. AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR O2GA2018081089101