N89342
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
FWD FA FLASHLIGHT NOT FLASHING/ REMOVED AND REPLACED BATTERY ON FWD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT
PHOTOLUMINSCENT STRIP MISSING FWD CABIN. R & R PHOTOLUMIN STRIPS WITH RED MARKS.
AFT FA FLASHLIGHT IS NOT BLINKING RED-----------REPLACED AFT FA FLASHLIGHT BATTERY - OPS CK GOOD
RH PYLON PANEL 419ML CHAFED. REPAIRED.
FLOOR GUSSET (TEXAS DOUBER) AT FR90 RBL24 CORRODED. REPLACED.
LH WING FIXED LEADING EDGE CHAFFED AT #1 PYLON
LH AFT PYLON FAIRING FWRWARD LOWER HEAT SHIELD HAS ELONGATED SCREW HOLES. REPAIRED
RH WING FIXED LEADING EDGE CHAFED AT #2 PYLON
LH WING FIXED LEADING EDGE CHAFED AT #1 PYLON
FLOOR GUSSET AT FR90 BL0 CORRODED. REPLACED.
RH MOP SILL FR88-FR90 CORRODED. REPLACED.
FLOOR BEAM AT FR87 (RH SHEAR PANEL) CORRODED. REPLACED.
FLOOR BEAM AT FR87 (RH SHEAR PANEL) CORRODED. REPLACED.
FUSELAGE SKIN UNDER FWD CARGO DOOR CUT-OUT COOORDED IN MULTIPLE PLACES. REPAIRED
EMER COCKPIT FO SIDE BULB OUT - PERFORMED OP CHECK, NO FAULT NOTED
L2 DOOR SLIDE DEPLOYMENT. SLIDE IS ON ORDER AND WILL BE REPLACED; CURRENTLY OUT OF SERVICE.
PARK BRK NO RELEASE MSG (EMERGENCY DECLARED). PERFORMED OPS CHECK. NO DEFECTS
RH FLOOR BEAM SEAT TRACK AFT END CORRODED AT FR84-FR85
AFT LAV SERVICE BOX SKIN DOUBLER FOUND TO BE CORRODED AT FR88 STR27R
LH SHEAR PANEL FR19-20 CORRODED
RH CENTER FLOOR BEAM CAP CORRODED AT FR88 - FR89
CENTER FLOORBEAM GUSSET AT FR90 CORRODED
INTERCOSTAL ANGLE AT RBL9 FWD OF FR90 CORRODED
GUSSET AT FR89 LBL9 FOUND TO BE CORRODED
RH I/B FLOOR BEAM GUSSET AT FR90 CORRODED
RH O/B FLOOR BEAM GUSSET AT FR90 CORRODED
RH FLOOR SILL FR88-90 CORRODED
LH WHEEL WELL FAIRING SUPPORT IS CRACKED AT FR52
RH SHEAR PANEL FR87-FR88 CORRODED
LH SHEAR PANEL AT FR87-FR88 CORRODED
RH FLOOR SILL PLATE CORRODED FR12-FR14
CENTER SHEAR PANEL AT FR87-FR88 CORRODED
INTERCOSTAL AT RBL9 BETWEEN FR90 AND FR100 CORRODED
INTERCOSTAL ANGLE AT RBL9 BETWEEN FR90 AND FR100 CORRODED
LH WHEEL WELL STUB ANGLE CRACKED AT FR52
CAPT FLASHLIGHT NOT CHARGING.
FWD FA FLASHLIGHT RED LIGHT NOT BLINKING. REPLACED BATTERY
ROW 12 EMERGENCY FLOOD LIGHT INOP. REPLACED BATTERY POWER SUPPLY #3 AND #4
FWD FA FLASHLIGHT INOP. PLACED ON MEL.
AFT FA FLASHLIGHT INOP PLACED ON MEL
FWD F/A FLASHLIGHT INOP. PLACED ON MEL.
FWD FA FLASHLIGHT INOPERATIVE. REPLACED THE BATTERY.
THE AFT FA FLASHLIGHT WAS INOPERATIVE. REPLACED THE BATTERY.
FWD FA FLASHLIGHT INOP. PLACED ON MEL.
FWD FA'S FLASHLIGHT INOP. PLACED ON MEL.
FO FLASHLIGHT INOP. R2 BATTERY.
CAPTAIN`S FLASHLIGHT WAS INOPERATIVE.
FIRST OFFICER`S FLASHLIGHT WAS INOPERATIVE.
FWD FA FLASHLIGHT INOPERATIVE.
CAPT FLASHLIGHT INOP. PLACED ON MEL.
FLASHLIGHT INOPERATIVE. R & R THE BATTERIES.
FWD FA FLASHLIGHT INOPERATIVE.