N900EM
Registered owner: EWM INVESTMENTS LLC, NV (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| CLAY LACY AVIATION, INC. (BKEA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
AFTER THE REPLACEMENT OF THE NR 1 AIR CONDITIONING PACK CONTROL VALVE WITH A REPAIRED VALVE, DURING THE OPS CHECK OF THE VALVE, IT CAUSED THE CIRCUIT BREAKER TO OPEN, FAILING THE TEST. A REVIEW OF THE TEARDOWN REPORT INDICATED THAT THE VALVE REPAIR WAS REQUIRED BECAUSE IT POPPED THE CIRCUIT BREAKER. AFTER INSTALLING A NEW VALVE THE SYSTEM WORKED NORMALLY WITHOUT POPPING THE CIRCUIT BREAKER. THE TOTAL TIME AND CYCLES ON THE REPAIRED VALVE WERE NOT REPORTED.
"FLAP LOW SPEED" EICAS MESSAGE DISPLAYED DURING CLIMBOUT AT APPROXIAMTELY 1,000' AGL FOLLOWED BY "FLAP FAIL" EICAS MESSAGE. FLAP SYSTEM OPERATION COMPLETELY INHIBITED. ACFT DIVERTED AND LANDED WITHOUT INCIDENT. FAULTY FECU, PN 363100-1011, SN 5282 WAS CONFIRMED DEFECTIVE AND WAS REPLACED. FLAP SYSTEM TESTED AND ACFT DEPARTED AND COMPLETED FLIGHT WITH NO FURTHER ISSUES.