N901EH

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

4 reports on file, 1995-03-24 – 2016-12-27.

PARTIAL RPM/PWR LOSS · 2016-12-27 Unresolved
ATA 7200

Part: ENGINE — MALFUNCTIONED (NR 1)

DURING LANDING, THE CREW REPORTED THAT THE NR 1 ENGINE STAYED AT IDLE AND FAILED TO RESPOND TO THROTTLE INPUTS. THE AIRCRAFT WAS ON A COMPANY REQUIRED CHECK FLIGHT FOR AN UNRELATED ISSUE AND NO PASSENGERS WERE ON BOARD. THE AIRCRAFT LANDED WITH OUT INCIDENT, NO WAS AN EMERGENCY DECLARED. THE AIRCRAFT IS CURRENTLY OUT OF SERVICE WHILE THE ISSUE IS BEING TROUBLESHOT.

Source: SDR 2017F00013
OTHER · 2013-01-30 Matched by certificate designator
ATA 5610

Part: WINDSHIELD — CRACKED (COCKPIT) · airframe 12,432 hrs · 8,965 cycles

AFTER CRUISING FOR APPROX 1.5 HOURS THE CREW WITNESSED A LOUD CRACKING NOISE AND NOTICED THE PILOT SIDE, LT WINDSHIELD HAD CRACKED. THE WINDOW WAS SPIDERED VEINED WITH CRACKS COVERING THE ENTIRE SURFACE. THE CREW DONNED OXYGEN MASKS TURNED ON SEAT BELT SIGN AND REQUESTED IMMEDIATE DECENT. ONCE THE ACFT HAD DECENDED TO FL250 THE ACFT DIVERTED FROM ITS ORIGINAL DESTINATION AND LANDED SAFELY.

Source: SDR A8OA201301300003
OTHER · 1995-03-24 Unresolved
ATA 7830

Part: HINGE — CRACKED (NR 2 THRUST REV)

DURING A SCHEDULED INSPECTION OF NR 2 T/R, THE RT AFT HINGE OF THE UPPER DOOR WAS FOUND CRACKED. CAUSE UNKNOWN.

Source: SDR 95ZZZX1746
OTHER · 1995-03-24 Unresolved
ATA 5620

Part: WINDOW — CRACKED (CABIN)

DURING SCHEDULED INSPECTION, PRISM CHECK OF CABIN WINDOWS WAS CONDUCTED AND 5 OF THE 10 WINDOWS WERE FOUND CRACKED. AFTER REMOVAL, CURED SEALANT WAS FOUND IN THE CRACKS INDICATING CRACKS BEGAN DURING INSTALLATION. THE 5-YEAR X-RAY INSPECTION WAS CONDUCTED ON 5-11-94 AND A PRISM INSPECTION WAS CONDUCTED DURING PRE-PURCHASE IN AUGUST, 1994. THESE WINDOWS WERE ALL PREVIOUSLY INSTALLED AND SHOULD HAVE BEEN DETECTED DURING ONE OF THE PREVIOUS INSPECTIONS.

Source: SDR 95ZZZX1793