N903HA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

4 reports on file, 1995-01-04 – 1996-01-13.

WARNING INDICATION · 1996-01-13 Matched by certificate designator
ATA 3230

Part: LOCK ACTUATOR — FAILED (LT MLG)

DCA/PHL - FLT 3098 - AFTER TAKEOFF WHEN LANDING GEAR WAS SELECTED UP, THE LEFT MAIN GEAR WOULD NOT FULLY RETRACT. THE AIRCRAFT TURNED BACK TO DCA AND LANDED WITHOUT INCIDENT. REMOVED AND REPLACED THE LEFT MLG LOCK ACTUATOR. (X)

Source: SDR HNAA9690304
SMOKE/FUMES/ODORS/SPARKS · 1995-11-15 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 3)

FLT NR 3015 - CRW-DCA - SHORTLY AFTER DEPARTURE, THE CABIN AND COCKPIT FILLED WITH SMOKE. THE AIRCRAFT RETURNED TO CRW AND LANDED WITHOUT INCIDENT. PERFORMED GROUND RUN WITH LEFT PACK ONLY, COULD NOT DUPLICATE, MEL 21-1. AT RON, REMOVED AND REPLACED NR 3 ENGINE. (M)

Source: SDR HNAA9590310
F.O.D.; SMOKE/FUMES/ODORS/SPARKS · 1995-11-14 Matched by certificate designator
ATA 7200

Part: ENGINE — BIRD STRIKE (NR 2 ENGINE)

FLT NR 3169 - DCA-PHL - ON DEPARTURE FROM DCA, A NOTICEABLE AMOUNT OF SMOKE FILLED THE COCKPIT. AIRCRAFT CONTINUED ON TO PHL AND LANDED WITHOUT INCIDENT. INSPECTED ENGINES NR 1 NR 4 BLEED VALVES AND DUCTING, FLOW CONTROL VALVES AND DUCTING. INSPECTED NR 2 ACM FOR CONDITION AND SECURITY. FOUND BIRD LODGED ON INTAKE SCREEN NR 2 ENGINE. REMOVED BIRD DEBRIS AND CLEANED INTAKE SCREEN. NO OTHER DISCREPANCIES NOTED. (M)

Source: SDR HNAA9590309
WARNING INDICATION · 1995-01-04 Matched by certificate designator
ATA 3230

Part: SEQUENCE VALVE — FAILED (NLG WW)

ORF-DCA - FLT 3003 - NOSE GEAR UNSAFE LIGHT REMAINS ILLUMINATED AFTER GEAR RETRACT SELECTED ON CLIMB-OUT. ACFT RETURNED TO ORF AND LANDED WITHOUT INCIDENT. REMOVED AND REPLACED UPPER NOSE LANDING GEAR SEQUENCE VALVE.

Source: SDR 95ZZZW94