93 reports on file, 1995-12-11 – 2018-02-20.

NO TEST · 2018-02-20 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 61,128 hrs · 33,325 cycles

MULTIPLE EMER LIGHTS IN F/C INOP. REMOVED & REPLACED APPLICABLE BATTERY POWER SUPPLY. OPS CHECK GOOD.

Source: SDR DALA2018022101052
NO TEST · 2018-02-20 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (AC BAY) · airframe 61,128 hrs · 33,325 cycles

TAIL COMP CATWALK ONE EMER LIGHT INOP. RECONNECTED WIRES & OPS CHECK GOOD.

Source: SDR DALA2018022101051
Earlier reports · 1995–2017 · 91 reports

2017

NO TEST · 2017-11-13 Matched by certificate designator
ATA 5350

Part: HANDLE — LACK OF LUBE (TAILCONE RELEASE) · airframe 60,480 hrs · 32,938 cycles

TAILCONE EMERGENCY RELEASE HANDLE EXCEEDS OPENING FORCE DURING TEST. ADJUSTED AND LUBED THE DOOR IAW MM. OPS CHECKED GOOD.

Source: SDR DALA2017111508150
FALSE WARNING · 2017-10-16 Matched by certificate designator
ATA 2612

Part: FIRE LOOP — BROKEN (B) · airframe 60,284 hrs · 32,825 cycles

DURING CLIMBOUT, RT ENGINE FIRE DETECTION FAULT ILLUMINATED. AIR RETURN DUE TO QRH GUIDANCE. C/W ODI EVENT, WORKCARD 2611-2002 R ENG FIRE DETECTION INT CHECK FOUND FLAME DEFLECTION B LOOP BROKEN. REPLACED ALL FIVE LOOPS IAW AMM 26-11. OPS CHECKED NORMAL. HIGH POWER RUN ACCOMPLISHED, NO FAULTS.

Source: SDR DALA2017101607531
OTHER · 2017-10-05 Matched by certificate designator
ATA 2701

Part: LEVER — BINDING (COCKPIT) · airframe 61,043 hrs · 33,281 cycles

AT FLARE FOR LANDING, ELEV CONTROL MAN ILLUMINATED AND YOKE CONTROL OF ELEVATOR FELT FROZEN OR JAMMED. DID NOT FEEL MERELY UN BOOSTED AND HYDRAULIC ELEVATOR CONTROL DID NOT INDICATE OFF. TROUBLESHOT AND FOUND LEFT SIDE LEVER ASSEMBLY BINDING. CAUSING MANUAL REVERSION. REMOVED AND REPLACED LEVER ASSEMBLY AND BEARINGS. OPERATION CHECKS GOOD.

Source: SDR DALA2018020600712
OTHER · 2017-10-02 Matched by certificate designator
ATA 3397

Part: CONNECTOR — DISCONNECTED (EMERGENCY LIGHT) · airframe 60,248 hrs · 32,801 cycles

THREE CEILING EMERGENCY LIGHTS WERE INOPERATIVE AT ROWS 32A, 39C, & 1 IN THE CATWALK. EMERGENCY LIGHT IN TAIL, FOUND FIXTURE ASSY WIRED WRONG, MOVED WIRE TO PROPER STUD. ROW 39C: FOUND DISCONNECTED WIRE - RECONNECTED & OPS GOOD. ROW 32A, FOUND DISCONNECTED WIRE, RECONNECTED & OPS CHECKED GOOD.

Source: SDR DALA2017101107441
OTHER · 2017-07-06 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (EMERGENCY LIGHT) · airframe 59,552 hrs · 32,415 cycles

CATWALK FIRST SIDEWALL EMERGENCY LIGHT INOPERATIVE. FOUND WIRE DISCONNECTED. INSTALLED NEW PIN AND SOCKET. OPERATION CHECKED GOOD.

Source: SDR DALA2017071005301
OTHER · 2017-03-24 Matched by certificate designator
ATA 3350

Part: LENS — UNSECURE (EMERGENCY LIGHT) · airframe 58,736 hrs · 31,988 cycles

EMERGENCY EXIT SIGN COVER LOOSE. SECURED.

Source: SDR DALA2017032702456
OTHER · 2017-03-11 Matched by certificate designator
ATA 3350

Part: LIGHT — MISSING (ROW 26 ABC) · airframe 58,643 hrs · 31,935 cycles

EMERGENCY LIGHT MISSING AT ROW 26 ABC. REPLACED THE EMERGENCY LIGHT IAW MM. OPS CHECKED GOOD.

Source: SDR DALA2017031502081
OTHER · 2017-01-11 Matched by certificate designator
ATA 5343

Part: SUPPORT FRAME — CRACKED (NLG) · airframe 58,194 hrs · 31,694 cycles

FOUND 2 CRACKS IN RIGHT NOSE LANDING GEAR SUPPORT FRAME BETWEEN BS 40 AND 60. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR FILLERS AND DOUBLERS IAW ERA 553838-14, REV O.

Source: SDR DALA2017011200298
OTHER · 2017-01-09 Matched by certificate designator
ATA 5310

Part: PANEL — CRACKED · airframe 58,194 hrs · 31,694 cycles

EMPENNAGE VENTRAL STAIRWAY AFT CUT OUT HAS 8 INCH CRACK IN LIGHT PANEL. REMOVED DAMAGE, FABRICATED AND INSTALLED NEW WEB SECTION IAW PRI/ERA 553835-14 AND DWG 991192.

Source: SDR DALA2017011300301
OTHER · 2017-01-09 Matched by certificate designator
ATA 5753

Part: VANE — GOUGED (RT WING TE FLAP) · airframe 58,194 hrs · 31,694 cycles

RIGHT WING OUTBOARD FLAP VANE LEADING EDGE GOUGED. REPAIRED IAW ERA 553839-14, REV O. AND SRM 51-10-02.

Source: SDR DALA2017011000297
OTHER · 2017-01-09 Matched by certificate designator
ATA 5300

Part: NOT REPORTED — CRACKED (NOT REPORTED) · airframe 58,194 hrs · 31,694 cycles

CRACK FOUND AT THE AFT EMERGENCY WALK WAY. REPAIRED IAW SRM 51-70-01.

Source: SDR DALA2017011000293
OTHER · 2017-01-09 Matched by certificate designator
ATA 5531

Part: FITTING — CRACKED (EMPENNAGE) · airframe 58,194 hrs · 31,694 cycles

CRACK IN THE RIGHT FITTING AT AUX SPAR TO EMPENNAGE ATTACH POINT. REMOVED AND REPLACED FITTING IAW SRM 51-30-02, 51-30-05, AND 51-10-05.

Source: SDR DALA2017011000295
OTHER · 2017-01-09 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (RT WING) · airframe 58,194 hrs · 31,694 cycles

RIGHT WING FIXED LEADING EDGE BELOW SLAT TRACK NR 8 SKIN CRACKED. REPAIRED IAW SRM 57-20-01.

Source: SDR DALA2017011000296
OTHER · 2017-01-07 Matched by certificate designator
ATA 5531

Part: ATTACH FITTING — CRACKED · airframe 58,193 hrs · 31,693 cycles

CRACK IN LEFT HAND FITTING AT AUXILIARY SPAR ATTACH TO EMPENNAGE. REMOVED AND REPLACED LEFT HAND AUX SPAR ATTACH FITTING IAW SRM 51-30-05, 51-30-01 AND DWG 9917704, REV Y.

Source: SDR DALA2017010900250
OTHER · 2017-01-05 Matched by certificate designator
ATA 5751

Part: SKIN — DELAMINATED (LT AILERON) · airframe 58,193 hrs · 31,693 cycles

LEFT AILERON LOWER SURFACE HAS SMALL AREA OF DELAMINATION. HOT BONDED PERMANENT REPAIR INTO LEFT AILERON LOWER SURFACE IAW SRM 57-50-02 AND 51-10-04.

Source: SDR DALA2017010600163
OTHER · 2017-01-03 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FUSELAGE) · airframe 58,193 hrs · 31,693 cycles

CRACK VERIFICATION. STOP DRILLED CRACK, FABRICATED AND INSTALLED DOUBLER ON RIGHT AFT NLG DOOR AFT HINGE CUTOUT IAW SRM 53-30-01.

Source: SDR DALA2017010400059
OTHER · 2017-01-03 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FUSELAGE) · airframe 58,193 hrs · 31,693 cycles

EXTERIOR FUSELAGE, AFT HINGE CUTOUT IS CRACKED AT AFT NLG DOOR. STOPPED DRILLED, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-30-01.

Source: SDR DALA2017010400058
OTHER · 2017-01-03 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CORRODED (BS 955) · airframe 58,193 hrs · 31,693 cycles

FOUND CUSP MEMBRANE CRACKED AT BS 955, LBL 64. REMOVED, FABRICATED AND INSTALLED NEW DOUBLER, FILLER AND RING DOUBLER IAW SRM 53-20-02.

Source: SDR DALA2017010500162

2016

OTHER · 2016-09-18 Matched by certificate designator
ATA 5350

Part: BAYONET — WORN (TAILCONE) · airframe 57,547 hrs · 31,311 cycles

DURING TAIL CONE EMERGENCY RELEASE, FOUND LT SIDE UPPER AND LOWER TAIL CONE BAYONETS WORN. REPLACED IAW CMM.

Source: SDR DALA2016091906729
INADEQUATE Q C · 2016-08-08 Matched by certificate designator
ATA 3350

Part: BULB — WRONG PART (EMERGENCY LIGHTS) · airframe 57,300 hrs · 31,152 cycles

EMERGENCY LIGHT NEAR L1 DOOR IS DIM. FOUND INCORRECT BULB INSTALLED AND EMERGENCY LIGHT ASSEMBLY AND STANDBY LIGHT ASSEMBLY CORRECTED. OPS CHECKED OK.

Source: SDR DALA2016081706062
OTHER · 2016-05-09 Matched by certificate designator
ATA 2565

Part: BOTTLE — LOW PRESSURE (R1 DOOR) · airframe 56,550 hrs · 30,715 cycles

R1 DOOR SLIDE PRESSURE LOW. R & R DOOR SLIDE IAW AMDS 2561-4641.

Source: SDR DALA2016051203955

2015

FLUID LOSS · 2015-01-30 Matched by certificate designator
ATA 7310

Part: TRANSMITTER — LEAKING (NR 1 FUEL FLOW) · airframe 53,056 hrs · 28,562 cycles

ON GROUND, WITH EXTERNAL AIR CONNECTED, STRONG ODOR OF FUEL AND EXHAUST FUMES FROM MID TO AFT OF ACFT. ODOR WAS PRESENT THROUGH MID CLIMB. MAINTENANCE FOUND FUEL FLOW TRANSMITTER LEAKING ON NR 1 ENGINE. R & R UPPER FLANGE O-RING IAW AMM. LEAK CHECK AND PACK BURNOUT OK.

Source: SDR DALA2015020200840

2014

OTHER · 2014-12-12 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (BS 1437) · airframe 52,856 hrs · 28,443 cycles

FUSELAGE SKIN CRACKED AT FASTENER, RT SIDE, BS 1437, 12 INCHES ABOVE RT PYLON. REPAIRED IAW PRI 531221-14, REV O.

Source: SDR DALA2014121306576
OTHER · 2014-12-09 Matched by certificate designator
ATA 5532

Part: FASTENER — LOOSE (VERTICAL STAB) · airframe 52,856 hrs · 28,443 cycles

LOOSE FASTENERS AT STA ZFS = 52.267 VERTICAL STABILIZER L/E. FOUND FIVE TOTAL HOLES OUT OF LIMITS AND REQUIRED BUSHING REPAIR IAW SG09550004-7003. INSTALLED DOUBLER IAW DW SR-09550004-7003, REV D.

Source: SDR DALA2014120906510
OTHER · 2014-12-07 Matched by certificate designator
ATA 5320

Part: SKATE ANGLE — CRACKED (BS 1458-1486) · airframe 52,856 hrs · 28,443 cycles

INTERNAL STABILIZER ATTACH ANGLE CRACKED, LT SIDE BS 1458 - 1486. R & R THE SKATE ANGLE IAW DWG 5912188.

Source: SDR DALA2014120906512
OTHER · 2014-12-07 Matched by certificate designator
ATA 5320

Part: SKATE ANGLE — CRACKED (BS 1458-1486) · airframe 52,856 hrs · 28,443 cycles

INTERNAL STABILIZER ATTACH ANGLE RT SIDE, BS 1458-1486 CRACKED. R & R SKATE ANGLE IAW DWG 5912188.

Source: SDR DALA2014120906511
OTHER · 2014-08-31 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (EMERGENCY LIGHTS) · airframe 52,203 hrs · 27,990 cycles

ALL AFT AIRSTAIRS LIGHTS INOPERATIVE. FOUND WIRES DISCONNECTED, CONNECTED THE WIRES AND OPERATES NORMAL.

Source: SDR DALA2014090304894

2013

NO TEST · 2013-12-02 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHTS) · airframe 50,260 hrs · 26,810 cycles

DURING SERVICE CHECK, FOUND EMERGENCY LIGHTS FOR TAIL SECTION CATWALK INOPERATIVE. MAINTENANCE R & R BATTERY PACK, B5-212. OPERATION CHECKS GOOD.

Source: SDR DALA13066079204
NO TEST · 2013-12-02 Matched by certificate designator
ATA 3397

Part: WIRE — LOOSE (EMERGENCY LIGHT) · airframe 50,260 hrs · 26,810 cycles

DURING SERVICE CHECK, TWO EMERGENCY LIGHTS INOPERATIVE AROUND ROW 35 AND 38. MAINTENANCE FOUND CONNECTOR WIRES J2-38B AND J2-48A LOOSE. RESEATED. OPS CHECKED GOOD.

Source: SDR DALA13066069204
NO TEST · 2013-10-04 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,870 hrs · 26,558 cycles

DURING SERVICE CHECK, MX FOUND EMERGENCY LIGHT ROW 36L, INOPERATIVE. REPLACED LAMP. OPS CHECKED GOOD.

Source: SDR DALA13050409204
NO TEST · 2013-10-04 Matched by certificate designator
ATA 3350

Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 49,870 hrs · 26,558 cycles

DURING SERVICE CHECK, MX FOUND EMERGENCY CEILING LIGHT ROW 38R INOPERATIVE. REPLACED LAMP. OPS CHECKED GOOD.

Source: SDR DALA13050419204
NO TEST · 2013-09-29 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (EMERGENCY LIGHT) · airframe 49,817 hrs · 26,528 cycles

DURING SERVICE CHECK, OVERWING EMERGENCY EXIT SIGN INOPERATIVE. FOUND WIRES DISCONNECTED IN CEILING PANEL. RECONNECTED WIRES. OPERATION CHECKS GOOD.

Source: SDR DALA13048009204
OTHER · 2013-03-31 Matched by certificate designator
ATA 3350

Part: BULB — BURNED OUT (EMERGENCY LIGHT) · airframe 48,514 hrs · 25,781 cycles

L1 DOOR EMERGENCY EXIT SIGN OVER DOOR INOPERATIVE. REPLACED LAMP. OPERATION CHECKED GOOD. OK FOR SERVICE.

Source: SDR DALA13014499204
OTHER · 2013-02-19 Matched by certificate designator
ATA 2565

Part: SLIDE — DAMAGED (L1 DOOR) · airframe 48,175 hrs · 25,611 cycles

L1 DOOR SLIDE, CANNOT SEE HORIZONTAL LINE ON THE GIRT BOTTOM EDGE IAW MM 25-61-01-420-801, PG 3. R & R L1 DOOR SLIDE IAW AMM.

Source: SDR DALA13008459204
OTHER · 2013-02-17 Matched by certificate designator
ATA 5712

Part: RIB — CRACKED (RT WING) · airframe 48,174 hrs · 25,610 cycles

RT WING FIXED L/E RIB AT OTBD EDGE OF SLAT IS CRACKED AT LOWER END. REJECTED, EDGE DISTANCE WAS NOT MAINTAINED ON REPAIR. REPAIRED CRACK AND MISDRILLED HOLES IAW ERA 509152-14, REV. O.

Source: SDR DALA13008109204
OTHER · 2013-02-17 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CRACKED (FUSELAGE) · airframe 48,175 hrs · 25,611 cycles

MAIN CABIN CUSP WEB AT STRINGER 18 IS CRACKED AT THE LIGHTNING HOLE LOCATED AT STA 1355R. REPAIRED MAIN CABIN CUSP WEB IAW SRM 51-10-03, 53-20-02 AND 53-10-03.

Source: SDR DALA13008439204
OTHER · 2013-02-16 Matched by certificate designator
ATA 5312

Part: BULKHEAD WEB — CRACKED (BS 1520 S4L) · airframe 48,174 hrs · 25,610 cycles

AFT AIRSTAIR AREA AT BS 1520 STRINGER 4L BULKHEAD WEB IS CRACKED. REPAIRED BULKHEAD IAW ER/A 510925-14 REV O.

Source: SDR DALA13008079204
OTHER · 2013-02-16 Matched by certificate designator
ATA 5313

Part: STRINGER — CRACKED (BS 1520) · airframe 48,174 hrs · 25,610 cycles

AFT AIRSTAIR AREA SKIN AT BS 1520 CANTED BULKHEAD STRINGER 4R IS CRACKED. REPAIRED STRINGER IAW ER/A 510924-14 REV O.

Source: SDR DALA13008089204
OTHER · 2013-02-15 Matched by certificate designator
ATA 5320

Part: ANGLE — CORRODED (BS 1364) · airframe 48,174 hrs · 25,610 cycles

AFT LAVATORY BS 1364, LBL 20 ANGLE CORRODED. REMOVED CORROSION. 100 PERCENT MATERIAL LOSS. OUT OF LIMITS. REPAIRED IAW ER/A 510933-14, REV O.

Source: SDR DALA13007949204
OTHER · 2013-02-15 Matched by certificate designator
ATA 5320

Part: SUPPORT BRACKET — DAMAGED (LT MLG WW) · airframe 48,175 hrs · 25,611 cycles

LEFT WHEEL WELL PANEL SUPPORT BRACKET DAMAGED. R & R SUPPORT BRACKET IAW ER/A 510934-14, REV O.

Source: SDR DALA13008399204
OTHER · 2013-02-13 Matched by certificate designator
ATA 5310

Part: STRUCTURE — CORRODED (BS 1344) · airframe 48,174 hrs · 25,610 cycles

DURING HMV, FOUND AFT CARGO BS 1344, BETWEEN STR 25 AND 26L EVIDENCE OF CORROSION. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. FABRICATED FILLER, TREATED, PRIMED AND INSTALLED IAW SRM 51-10-03, 51-20-00 AND ERA 510932-14, REV O.

Source: SDR DALA13008269204
OTHER · 2013-02-09 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (BS 1364) · airframe 48,174 hrs · 25,610 cycles

AFT LAVATORY, BS 1364 LBL 22 SEAT TRACK UPPER END CORRODED. REMOVED CORROSION. OUT OF LIMITS. R & R SEAT TRACK IAW SRM 53-40-01, FIG 6.

Source: SDR DALA13006789204
OTHER · 2013-02-08 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1364) · airframe 48,174 hrs · 25,610 cycles

AFT CABIN BS 1364, LBL 20 FLOORBEAM CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS IAW ERA 510933-14, REV.

Source: SDR DALA13006779204
OTHER · 2013-02-08 Matched by certificate designator
ATA 5531

Part: FRAME — CORRODED (VERTICAL STAB) · airframe 48,174 hrs · 25,610 cycles

VERTICAL STABILIZER UPPER FORWARD END, LT SIDE FRAME FOR SKIN PANEL, CORRODED. WORK ACCOMPLISHED ON ER/A 510927-14, REV O.

Source: SDR DALA13006879204
OTHER · 2013-02-08 Matched by certificate designator
ATA 5532

Part: SKIN — CORRODED (VERTICAL STAB) · airframe 48,174 hrs · 25,610 cycles

VERTICAL TIP FORWARD END, RT SIDE FRAME FOR SKIN PANEL CORRODED. WORK ACCOMPLISHED ON ER/A 510927-14, REV O.

Source: SDR DALA13006889204
OTHER · 2013-02-07 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (BS 160) · airframe 48,174 hrs · 25,610 cycles

FORWARD GALLEY RT SIDE BS 160 SUPPORT WEB CORRODED. REMOVED CORROSION, OUT OF LIMITS IAW 53-00-01. OK FOR SERVICE IAW ERA 510923-14, REV O.

Source: SDR DALA13006849204
INADEQUATE Q C · 2013-02-06 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — DAMAGED (BS 1174-1212) · airframe 48,174 hrs · 25,610 cycles

AFT CARGO COMPARTMENT BS 1174 TO 1212 LT SEAT TRACK SUPPORT HAS SEVERAL MISDRILLED HOLES. FABRICATED ALL SPLICES IAW SRM 53-40-01, PG 41.

Source: SDR DALA13006709204
INADEQUATE Q C · 2013-02-06 Matched by certificate designator
ATA 5347

Part: CARGO TRACK — DAMAGED (BS 1212-1250) · airframe 48,174 hrs · 25,610 cycles

AFT CARGO COMPARTMENT BS 1212-1250 LT CARGO TRACK HAS SEVERAL PREVIOUS MISDRILLED HOLES. INSTALLED CARGO TRACK LT, STA 1174-1250 IAW SRM 53-40-01, PG 40.

Source: SDR DALA13006829204
OTHER · 2013-02-06 Matched by certificate designator
ATA 5347

Part: CARGO TRACK — CORRODED (BS 1174-1212) · airframe 48,174 hrs · 25,610 cycles

AFT CARGO COMPARTMENT BS 1174 TO 1212 LT CARGO TRACK SUPPORT HAS LIGHT CORROSION AT SCREW HOLES. FABRICATED NEW CARGO TRACK SECTION IAW 53-40-01, FIG 7 FOUND ADDITIONAL DAMAGE. FOUND TO BE OUT OF LIMITS OF SRM 53-40-01.

Source: SDR DALA13006729204
OTHER · 2013-02-06 Matched by certificate designator
ATA 5347

Part: CARGO TRACK — CORRODED (BS 1079-1136) · airframe 48,174 hrs · 25,610 cycles

AFT CARGO COMPARTMENT BS 1079 TO 1136, LT CARGO TRACK SUPPORT HAS CORROSION AROUND HOLES INSTALLED LT CARGO TRACK IAW SRM 53-40-01 PG 40. OUT OF LIMITS IAW SRM 53-00-01, PG 9.

Source: SDR DALA13006719204
OTHER · 2013-02-05 Matched by certificate designator
ATA 5330

Part: SKIN — CORRODED (BS 788-845) · airframe 48,174 hrs · 25,610 cycles

RT SIDE LOWER EXTERNAL FUSELAGE SKIN CORRODED BS 788+10" - 845 AT FORWARD FILLET FAIRINGS. BLENDED AFFECTED AND FOUND SECOND AREA GOUGED BLENDED AREA OUT OF LIMITS IAW SRM 53-30-01. FABRICATED AND INSTALLED REPAIR SRM 53-30-01 PAGES 69-81.

Source: SDR DALA13006819204
OTHER · 2013-02-03 Matched by certificate designator
ATA 5340

Part: ATTACH ANGLE — CORRODED (BS 388) · airframe 48,174 hrs · 25,610 cycles

FORWARD CARGO COMPARTMENT DOOR CUTOUT LOWER SILL WEB ATTACH ANGLE CORRODED FROM BS 388. REMOVED CORROSION. OUT OF LIMITS. R & R DAMAGED SECTION OF ATTACH ANGLE IAW SRM 53-60-02, FIG 11.

Source: SDR DALA13006859204
OTHER · 2013-01-22 Matched by certificate designator
ATA 5320

Part: CUSP WEB — CORRODED (BS 465) · airframe 48,174 hrs · 25,610 cycles

DURING HMV, RT CABIN CUSP WEB AT STA 465+4 HAS CORROSION ON THE TOP AND BOTTOM SIDE AS MARKED. CPCP 53-211-01. CHECKED LIMITS OF ORIGINAL .020 REMT .014 LOSS OF MATERIAL, .006 FOUND DAMAGED AREA OUT OF LIMITS IAW SRM 53-00-01, FIG 3, VOL I. FABRICATED, LOCATED, DRILLED AND INSTALLED REPAIR DOUBLER IAW SRM 53-20-02, FIG 10, VOL I.

Source: SDR DALA13005819204

2012

OTHER · 2012-06-05 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FUSELAGE) · airframe 46,749 hrs · 24,805 cycles

NR 114 STA 1475 STR 1 AND BETWEEN STR 2LT .250 SKIN CRACKED LOOKING UP FROM WALKWAY MARKED. REPAIRED PER ERA503973-14 REV ORIG.

Source: SDR DALA1235769204
OTHER · 2012-06-05 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FUSELAGE) · airframe 46,749 hrs · 24,805 cycles

N/R 94 SKIN CRACKED LEFT SIDE STA 1475 FROM RIVET JUST OTBD OF SKATE ANGLE. REPAIRED PER ERA 503973-14 REV ORIG.

Source: SDR DALA1235729204
OTHER · 2012-06-05 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FUSELAGE) · airframe 46,749 hrs · 24,805 cycles

N/R113 STA 1475 STR 1 AND BETWEEN STR 2 RT 1.5 IN SKIN CRACKED LOOKING UP FROM WALKWAY MARKED. REPAIRED PER ERA503973-14 REV ORIG.

Source: SDR DALA1235739204
OTHER · 2012-06-04 Matched by certificate designator
ATA 5330

Part: SKIN — CRACKED (FUSELAGE) · airframe 46,749 hrs · 24,805 cycles

SKIN CRACKED RT SIDE STA 1475 FROM RIVET OUTBOARD OF SKATE ANGLE, N/R 90. REPAIRED PER ERA503973-14 REV ORIG.

Source: SDR DALA1235719204
OTHER · 2012-06-01 Matched by certificate designator
ATA 5532

Part: SKIN — WORN (VERTICAL STAB) · airframe 46,749 hrs · 24,805 cycles

WHILE PERFORMING VERTICAL STABILIZER LEADING EDGE SKIN INSPECTION EA_JIC 02-470871-12AD REV C ME01,9 LEADING EDGE HOLES WERE FOUND WORN AND WRITTEN ON NR CARD 99, PER STEP 3 OF SAME EA JIC, ME05 WAS ISSUED. THE LEADING EDGE WAS REMOVED ON NR 107 AND REPAIRS WERE ACCOMPLISHED PER SERVICE GENERAL REPAIR DRAWING SG09550004 WITH NO DEVIATIONS ON NR 108. THE LEADING EDGE WAS REINSTALLED ON NR 107 WHERE IT WAS PREVIOUSLY REMOVED.

Source: SDR DALA1235289204
OTHER · 2012-05-07 Matched by certificate designator
ATA 5230

Part: SKIN — DAMAGED (CARGO DOOR)

MID CARGO AFT DOOR FRAME SKIN DAMAGE. TRIMMED DAMAGED AREA NO EVIDENCE OF CRACKS. ACCOMPLISHED HFEC OF DAMAGE CUTOUT PER NPTSPM 06-10-01.001 NO CRACKS NOTED. REPAIRED DAMAGE PER ERA 503192-14, REV ORIG. OK FOR SERVICE.

Source: SDR DALA1229759204
OTHER · 2012-05-05 Matched by certificate designator
ATA 5330

Part: SKIN — DAMAGED (FUSELAGE) · airframe 49,973 hrs · 26,624 cycles

FUSELAGE, MID CARGO DOOR CUTOUT, BS 750, DTA SKIN TRIM OUTER AFT EDGE.

Source: SDR DALA13054599204
OTHER · 2012-02-25 Matched by certificate designator
ATA 2560

Part: CABLE — FRAYED (TAILCONE) · airframe 46,065 hrs · 24,431 cycles

DURING SERVICE CHECK, MAINTENANCE FOUND THE CABLE FOR THE TAIL CONE NITROGEN BOTTLE FRAYED. MAINTENANCE INSTALLED, RIGGED AND SAFETIED NEW CABLE PER JIC/OPN 69100.

Source: SDR DALA1210969204
OTHER · 2012-02-25 Matched by certificate designator
ATA 2560

Part: RELEASE CABLE — FRAYED (TAILCONE) · airframe 46,065 hrs · 24,431 cycles

DURING CHECK, MAINTENANCE FOUND 3 INCH CABLE FOR LOCKING HTE INSIDE HANDLE FRAYED. INSTALLED NEW CABLE, REF OPN 69100 CARD 1. TAILCONE EMERGENCY RELEASE MECHANISM. OPERATION CHECKS GOOD. RII C/W ON OPN 69100 QC 1978.

Source: SDR DALA1211699204
OTHER · 2012-01-29 Matched by certificate designator
ATA 3244

Part: TIRE — DAMAGED (NLG) · airframe 45,915 hrs · 24,352 cycles

UPON LANDING, WITH FULL RIGHT REVERSER AND MAX BRAKES, BRAKING ACTION WAS REPORTED NIL. AIRCRAFT SLID OFF RUNWAY. MAINTENANCE PERFORMED SIDE LOAD CHECKS. NO DEFECTS NOTED BESIDES NOSE TIRES. REMOVED AND REPLACED NOSE LANDING GEAR TIRES. AIRCRAFT OKAY FOR SERVICE.

Source: SDR DALA1205319204

2011

FLAME/FIRE · 2011-05-04 Matched by certificate designator
ATA 3242

Part: BRAKE — FIRE (MLG) · airframe 43,874 hrs · 23,388 cycles

AFTER LANDING AND TAXIING TO THE GATE, THE LEFT MAIN GEAR BRAKE WAS REPORTED BY THE RAMP TO BE ON FIRE. SOME PASSENGERS WERE EVACUATED THROUGH THE R1 SERVICE DOOR AND SLIDE. REPLACED THE NR 1 AND NR 2 BRAKE ASSEMBLIES, BOTH THE NR 1 AND NR 2 MAIN WHEEL ASSEMBLIES, AND PERFORMED ANTI-SKID SYSTEM TEST. OPERATIONAL CHECK OF THE DUAL ANTI-SKID CONTROL MANIFOLDS CHECKED GOOD. ALL OTHER TESTS PASSED. THE R1 DOOR SLIDE WAS REPLACED PER THE AMM.

Source: SDR DALA1131629204

2010

NO TEST · 2010-11-17 Matched by certificate designator
ATA 3397

Part: WIRE — DAMAGED (CABIN) · airframe 42,705 hrs · 22,890 cycles

DURING LINE CHECK MAINTENANCE FOUND EMERGENCY PATH LIGHT AT SEAT 1C INOPERATIVE. MAINTENANCE RE-TERMINATED THE WIRES AND OPERATION OF LIGHT NOW CHECKS OK. (2010-D1376) (DLM90103210)

Source: SDR DALA1032799204
OTHER · 2010-09-04 Matched by certificate designator
ATA 3350

Part: LENS — MISSING (EMERGENCY LIGHTS) · airframe 42,092 hrs · 22,620 cycles

DURING LINE CHECK MX, FOUND EMERGENCY LIGHT INOPERATIVE AND MISSING LENS IN ROW 1. MX REPAIRED CRUSHED WIRING AND REPLACED MISSING LENS MODULE IN ROW 1. OPS CHECK OF LIGHT CHECKS OK.

Source: SDR DALA1021790904
WARNING INDICATION · 2010-03-31 Matched by certificate designator
ATA 2910

Part: HYDRAULIC SYSTEM — LOW (RIGHT) · airframe 40,920 hrs · 22,018 cycles

JUST PRIOR TO DECENDING, RT HYD SYS QTY DROPPED TO 6, DID ABNORMAL IN QRH 1213. CONFIGUERED FOR LAND ICW QRH, LANDED W 28 DEGREE FLAPS. UNEVENTFUL SHUTDOWN WITH LT QTY 11 RT 8 DECLARED EMERGENCY LANDING.

Source: SDR DLM90100790
NO TEST · 2010-03-02 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ROWS 13C & 14C) · airframe 40,774 hrs · 21,917 cycles

EMERGENCY ESCAPE PATH LIGHTS INOP AT SEAT ROWS 13C AND 14C. REPLACED ENTIRE FLOOR TRACK LIGHTING FROM ROWS 10 THRU 14 ALL LIGHTS NOW TEST OK.

Source: SDR DLM90100549
NO TEST · 2010-01-20 Matched by certificate designator
ATA 2565

Part: SLIDE — INOPERATIVE (L2 DOOR) · airframe 40,499 hrs · 21,756 cycles

DURING A PLANNED 2L DOOR SLIDE DEPLOYMENT IAW OP 6800 THE SLIDE DID NOT INFLATE. THIS OCCURRED ON 1-20-10. THE SLIDE PACK WAS ATTACHED TO THE FLOOR FITTINGS AND EXITED THE DOOR CAVITY BUT MERELY HANGED OUTSIDE THE ACFT WITHOUT INFLATING. THE OP 6800 DATA RETRIEVAL WAS SUBMITTED INDICATING THIS AND A SERVICEABLE SLIDE WAS INSTALLED ONTO THE 2L DOOR. THE SLIDE WHICH FAILED TO DEPLOY WAS SENT FOR SHOP EVALUATION WITH ALL NECESSARY DOCUMENTATION.

Source: SDR DLM90100146

2008

F.O.D.; WARNING INDICATION · 2008-10-25 Matched by certificate designator
ATA 7200

Part: ENGINE — BIRD INGESTION (NR 2) · airframe 37,496 hrs · 19,995 cycles

HIT BIRD AT ABOUT 135 KTS. HIGH SPEED ABORT ACCOMPLISHED AND PARKED WITH HOT BRAKES. RT ENGINE FLUCTUATED AND HAD NOTICABLE POWER LOSS WITH THE BIRD STRIKE. BRAKE TEMP REACHED 650. REPLACED NR 2 ENGINE.

Source: SDR DLM90081435
FLUID LOSS; FLAME/FIRE · 2008-02-21 Matched by certificate designator
ATA 3240

Part: BRAKE — LEAKING (LEFT MLG) · airframe 35,869 hrs · 19,033 cycles

A/C ARRIVED AND HAD A HOT BRAKE NR 2, BRAKE WAS LEAKING HYD FLUID AND STARTED BURNING. FIRE WENT OUT ON ITS OWN. REPLACED NR 1 AND NR 2 BRAKE ASSYS PER M/M.

Source: SDR DLM90080254

2006

SMOKE/FUMES/ODORS/SPARKS · 2006-12-13 Matched by certificate designator
ATA 2420

Part: GENERATOR — ODOR · airframe 32,961 hrs · 17,401 cycles

ELECTRICAL SMELL/SMOKE IN THE CABIN ON ROTATION FROM SJC. CREW ELECTED TO RETURN TO SJC. INFLIGHT EMERGENCY WAS DECLARED. ODOR DISSIPATED PRIOR TO LANDING. NO EMERGENCY DOOR SLIDES WERE BLOWN AND NO INJURIES REPORTED. REPLACED CONVERTER ELECTRONICS UNIT AND INTERCONNECTING HARN ASSY 475757.

Source: SDR DLM90061026
INADEQUATE Q C; FLUID LOSS; WARNING INDICATION · 2006-04-04 Matched by certificate designator
ATA 2410

Part: GENERATOR — LACK OF LUBE (NR 1 ENGINE) · airframe 31,293 hrs · 16,436 cycles

AT CRUISE POWER DISRUPTED W/L AC PWR FAULT AND L GEN OFF MSG GEN WOULD NOT RESET. ACCOMPLISHED QRH PROCEDURE. LEFT BUS RECEIVED PWR FROM APU GEN BUT APU FAULT MSG ILLUMINATED. L ELEC SYS FAIL AND L GEN OIL PRESS MSGS APPEAR WHEN STATUS BUTTON PUSHED. (ATL MTC/0245Z/MB) PRIOR TO DES APU GEN TRIP FOUND LT GEN HAD LOST ALL OIL. REPLACED LT GEN. ALSO FOUND RIGID FLEX LINE TO OIL COOLER LEAKING. REPLACED RIGID FLEX LINE TO OIL COOLER, LEAKED CHECKED LINE AND CHECKED LT GEN FOR PROPER SERVICING, ALL OK L GEN VOLTS AND FREQS CKD OK AND CARRIED LOAD. RAN APU SEVERAL TIMES WITH FULLY LOADED BUSES APU GEN OPS GOOD.

Source: SDR DLM90060238

2005

SMOKE/FUMES/ODORS/SPARKS; FLAME/FIRE · 2005-12-20 Matched by certificate designator
ATA 4940

Part: STARTER — UNSERVICEABLE (APU) · airframe 30,675 hrs · 16,095 cycles

ON APU START, APU FAULT DISPLAYED AND SMOKE COMING FROM TAIL COMPT. ON FURTHER INSP, SAW VISIBLE FLAME COMING FROM APU STARTER. FLAME WENT OUT AND NO EXTINGUISHING AGENT WAS NEEDED. REPLACED STARTER, CLUTCH, AND START RELAY.

Source: SDR DLM90050808
FLUID LOSS; WARNING INDICATION · 2005-03-12 Matched by certificate designator
ATA 3240

Part: BRAKE — LEAKING (MLG) · airframe 28,680 hrs · 15,032 cycles

HYDRAULIC QTY LOW LT HAND. FOUND NR 1 BRAKE ASSEMBLY LEAKING FROM THE SIX O`CLOCK POSITION. REMOVE AND REPLACE NR 1 BRAKE ASSY AND SERVICED LT HYDRAULIC SYSTEM AS PER AMM. NO LEAKS FOUND.

Source: SDR DLM90050157
SMOKE/FUMES/ODORS/SPARKS · 2005-03-09 Matched by certificate designator
ATA 2530

Part: COFFEEMAKER — DIRTY (GALLEY) · airframe 28,660 hrs · 15,021 cycles

CLEANED BURNED COFFEE FROM HOT PLATE IN AFT GALLEY DUE TO BURNING SMELL.

Source: SDR DLM90050153

2004

PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2004-08-24 Matched by certificate designator
ATA 7200

Part: ENGINE — FAILED (NR 2) · airframe 27,494 hrs · 14,425 cycles

AS POWER WAS PUSHED UP FOR TAKEOFF RIGHT ENGINE OIL PRESSURE LO LIGHT CAME ON AND OIL PRESSURE INDICATED ZERO. SHUT DOWN ENGINE AFTER APPROX 10 SECONDS. REPLACED ACCESSORY GEARBOX.

Source: SDR DLM90040824

2003

WARNING INDICATION · 2003-11-02 Matched by certificate designator
ATA 3222

Part: STRUT — LOW (NLG) · airframe 25,297 hrs · 13,393 cycles

NOSE GEAR FAILED TO RETRACT ON T/O, 3 VGRN WITH GEAR HANDLE DOWN. SERVICED NOSE GEAR PER M/M 32-21-01-619-801, NOSE GEAR OPERATION CHECKS NORMAL.

Source: SDR DLM90030977
ENGINE FLAMEOUT; WARNING INDICATION · 2003-03-27 Matched by certificate designator
ATA 7200

Part: ENGINE — SHUTDOWN (NR 2) · airframe 23,886 hrs · 12,671 cycles

NUMBER 2 ENGINE SHUT DOWN ON DESCENT INTO DFW. FOUND NUMEROUS VSV AND ACC FAULTS. REPLACED ENGINE.

Source: SDR DLM90030294
VIBRATION/BUFFET · 2003-03-12 Matched by certificate designator
ATA 3231

Part: DOOR — OPEN (NLG) · airframe 23,758 hrs · 12,602 cycles

AIRCRAFT HAD AN AIR TURNBACK. UPON GEAR RETRACTION, NOSE GEAR MADE A LOUD NOISE AND CONTINUED TO SPIN. NO GEAR OR GEAR DOOR LIGHTS. GEAR ALSO VIBRATED. ONCE AT GATE MAINTENANCE FOUND THE LEFT NOSE GEAR DOOR OPEN. RESECURED NOSE GEAR DOOR.

Source: SDR DLM90030236

2002

WARNING INDICATION; AFFECT SYSTEMS · 2002-08-05 Matched by certificate designator
ATA 1430

Part: SCREW — LOOSE (E/E BAY) · airframe 22,154 hrs · 11,795 cycles

AIR TURNBACK, 2L DOOR HAD A LARGE AIRLEAK AUTO CONTROLLER DID NOT HAVE OUTFLOW VALVE FULL CLOSED. GOT CABIN ALT WARN LIGHT CABIN WAS AT 10000 FT/BIT AUTO CONTROLLER 1 FAULTED GROUND SWITCH. PRESSURIZED A/C PER M/M, NO DOOR LEAKS NOTED. FOUND LOOSE SCREW HAD FALLEN INTO RELAY R2-4 SHORTING TERMINALS D1 AND D2. REPLACED RELAY. PERFORMED BIT TEST PER PER M/M. ALL CKS GOOD. PERFORMED TEST OF SYS AND FOUND SYS TESTS NORMAL.

Source: SDR DLM90020907

2001

ELECT. POWER LOSS-50 PC; WARNING INDICATION · 2001-07-04 Matched by certificate designator
ATA 2421

Part: GENERATOR — MAKING METAL (NR 1 ENGINE) · airframe 18,978 hrs · 10,166 cycles

LT AC FAULT MSG IN FLT, LT GEN OIL FILTER STATUS MSG. FOUND METAL IN GEN FILTER. REPLACED GEN, OP CHECKS OK.

Source: SDR DLM90011114
SMOKE/FUMES/ODORS/SPARKS · 2001-06-26 Matched by certificate designator
ATA 4940

Part: STARTER — MALFUNCTIONED (APU) · airframe 18,912 hrs · 10,132 cycles

ON APU START ATTEMPT AT THE GATE IN SNA. SMOKE WAS OBSERVED COMING FROM APU COMPARTMENT. MTC OPENED COMPT AND OBSERVED THE STARTER GLOWING RED. FIRE DEPT DISCHARGED HALON INTO COMPT. CTC MTC ADVISED THERE WERE FLAMES INITIALLY WHEN DOOR WAS OPENED. REPLACED APU.

Source: SDR DLM90011069
FLUID LOSS; WARNING INDICATION · 2001-04-19 Matched by certificate designator
ATA 2916

Part: RESERVOIR — LEAKING (RT MLG WW) · airframe 18,315 hrs · 9,820 cycles

LOSS OF RT HYD PRESSURE, WENT TO ZERO AND OVERTEMP. FOUND RT HYD RES. LEAKING INTERNALLY. REPLACED SAME.

Source: SDR DLM90010645
FALSE WARNING · 2001-03-26 Matched by certificate designator
ATA 3260

Part: INDICATOR — FALSE INDICATION (COCKPIT) · airframe 18,128 hrs · 9,719 cycles

AFTER RAISING GEAR RT MAIN RED LIGHT REMAINED ON. ALL GREENSOUT, GEAR DOOR LIGHT OUT, LOWERED LANDING GEAR PER CKLIST ALL 3 GREEN ON, ALL REDS OUT BUT DOOR LIGHT REMAINED ON FOR APPROX. 2 MIN. LANDING GEAR DOOR LIGHT FLICKERED ON/OFF UNTIL A/C WAS SLOWED FOR APPROACH DOOR LIGHT WENT OUT - JACKED A/C AND SWUNG GEAR - TESTED PROX SWITCHES - NO TROUBLE FOUND - UNABLE TO DUPLICATE

Source: SDR DLM90010506

2000

NO TEST · 2000-12-18 Matched by certificate designator
ATA 3397

Part: WIRE — DAMAGED (CABIN) · airframe 17,662 hrs · 9,480 cycles

EMERGENCY FLOOR TRACK LIGHTING INOP.FROM 2C TO 12C. FOUND WIRE DAMAGED AT SEAT 2C.REPAIRED SAME.

Source: SDR DLM90002475
NO TEST · 2000-03-27 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (SEAT 13) · airframe 15,435 hrs · 8,299 cycles

FOUND EMERGENCY TRACK LIGHT AT SEAT 13 WITH BROKEN WIRING. SPLICED NEW SOCKET IN LINE, OPERATIONAL CHECKS OK.

Source: SDR DLM90000584

1999

WARNING INDICATION · 1999-10-02 Matched by certificate designator
ATA 2150

Part: VALVE — INOP (LT PACK)

LT PACK FLOW OF ABOUT 20 PERCENT FLOW LIGHT ON FROM T/O TO 10,000. NO CHANGE IN FLOW PERCENT. RATE OF A/C CLIMBING SLOWED TO 1000 PPM, STILL HAD FLOW LITE. REPLACED LT PACK FLOW CONTROL VALVE. A/C PRESSURIZED GOOD.

Source: SDR DLM90992189

1996

WARNING INDICATION · 1996-06-21 Matched by certificate designator
ATA 3222

Part: SCHRADER VALVE — FAILED (NLG)

ON GEAR RETRACTION, NOSE GEAR UNSAFE LIGHT REMAINED ON WITH HANDLE UP. NLG INDICATOR WAS FLUSH, RECYCLED IN ACCORDANCE WITH POM BUT LIGHT STAYED ON WHEN ANOTHER RETRACTION WAS ATTEMPTED. REPLACED NOSE STRUT SCHRADER VALVE AND O-RING. SERVICED STRUT IN ACCORDANCE WITH MAINT MANUAL. PERFORMED NOSE GEAR RETRACT CHECK, OPERATION NORMAL.

Source: SDR DLM90961500
NO TEST · 1996-01-22 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

ON PREFLIGHT, FLOOR EMERGENCY PATH LIGHTS INOP IN FWD CABIN. FOUND BROKEN WIRE AT SEAT ROW 10. REPAIRED WIRE, OPERATION NORMAL.

Source: SDR DLM90960324

1995

FLUID LOSS · 1995-12-11 Matched by certificate designator
ATA 2910

Part: HYD TUBE — LEAKING (FS 1322)

IR - L-SYSTEM HYD QTY READS 8 QTS. ON WALK-AROUND, SAW FLUID LEAKING FROM 2 DRAIN HOLES AFT OF MAIN GEAR. FOUND FWD PRESS LINE TO EMPENNAGE RUBBED THROUGH ON OUTFLOW VALVE ACTUATOR AT LT FS 1322. REVERSED BOLTS TO GAIN CLEARANCE AND MADE PERMANENT REPAIR TO LINE WITH RING LOCK.

Source: SDR DLM90954689