N90SJ

CESSNA 525B · 2007 · Fixed-wing multi-engine · 2 engines · 8 seats · Valid Registration

Registered owner: TURBO AIR CHARTER LLC, ID (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

6 reports on file, 2023-04-03 – 2024-01-26.

OTHER · 2024-01-26 Matched by certificate designator
ATA 3421

Part: BATTERY PACK — FAILED INSP (STDBY GYRO) · airframe 4,743 hrs · 3,618 cycles

STANDBY GYRO BATTERY PACK FAILED CAP CHECK. R&R WITH OVERHAULED UNIT P/N 501-1712-01. OPS CHECK GOOD

Source: SDR 3NXA20240131002
OTHER · 2024-01-23 Matched by certificate designator
ATA 5220

Part: SCREW — BACKED OUT (DOOR LATCH PLATE) · airframe 4,743 hrs · 3,618 cycles

DURING SCHEDULED INSPECTION OF EMERGENCY EXIT DOOR, FOUND THE SCREWS FOR THE LATCH PLATE AT THE TOP OF THE DOOR FRAME WERE CAUSING GOUGES IN THE EMERGENCY EXIT DOOR. VERIFIED GOUGES WERE WITHIN LIMITS TO BE BLENDED. BLENDED DAMAGE, VERIFIED THICKNESS OF REMAINING MATERIAL WITHIN LIMITS, PRIMED AREA AND REINSTALLED.

Source: SDR 3NXA20240131001
MULTIPLE FAILURE; FLT CONT AFFECTED · 2023-07-27 Matched by certificate designator
ATA 2133

Part: OUTFLOW VALVE — INOPERATIVE (UNKNOWN) · airframe 4,591 hrs · 3,478 cycles

CLIMBING OUT OF LUK CABIN WOULD NOT PRESSURIZE, CABIN HIGH ALTITUDE ALERT CAME ON. AIRCRAFT RETURNED TO BASE USING MANUAL PRESSURIZATION MODE. MANUAL PRESSURIZATION MODE HAD NO DEFECTS. FOUND CONTROLLER SHOWING FAULT WHEN PERFORMING BITE TEST. R&R CONTROLLER. NO PRESSURIZATION. CONFIRMED PRE-PRESSURIZATION. FOUND DOOR SEAL PRESSURE REGULATOR ONLY SUPPLYING 10PSI, (23 REQUIRED), AND DOOR SEAL NOT FULLY INFLATING. R&R DOOR SEAL PRESSURE REGULATOR. NO PRESSURIZATION. CHECKED OUTFLOW VALVE FUNCTION, APPEARS TO BE OPERATING. CHECKED SQUAT SWITCHES FOR CORRECT SIGNAL TO LDG PCB, CORRECT SIGNAL BEING RECEIVED. SQUAT SWITCH SIGNAL FROM LDG PCV TO PRESS PCB GOOD. PRESS PCB RECEIVING GOOD SIGNAL IN BUT NOT SENDING ANY VOLTAGE (2.8V, 28V REQUIRED) OUT TO CONTROLLER. R&R PRESS PCB. GOOD SIGNAL AT CONTROLLER NOW, PERFORMS CORRECTLY WITH SQUAT SWITCHES IN DIFFERENT POSITIONS. CHECKED POWER AND SIGNAL ON OUTFLOW VALVE, CONTROLLER, PCB'S, AND SQUAT SWITCHES. NO PRESSURIZATION. USED STATIC LINE TESTER TO CHECK FOR LEAKS FROM OUTFLOW VALVE STATIC LINES, NO LEAKS NOTED. USED TESTER TO CHECK FOR LEAKS FROM MANUAL PRESSURIZATION TOGGLE SWITCH FORWARD TO STATIC LINE IN NOSE WHEEL WELL. FOUND MANUAL PRESSURIZATION TOGGLE SWITCH LEAKING. R&R. NO PRESSURIZATION. FOUND THE R/H PRSOV TO BE INOP. R&R R/H PRSOV. FOUND R/H SQUAT SWTICH SLIGHTLY OUT OF RIG WHEN RAISING AIRCRAFT ON JACKS, ADJUSTED. CONFIRMED CORRECT 429 SIGNAL AT CONTROLLER. R&R OUTFLOW VALVE. OPS CHECK GOOD.

Source: SDR 3NXA20230727005
OTHER · 2023-07-06 Matched by certificate designator
ATA 2150

Part: WHEEL — OUT OF POSITION (BLOWER) · airframe 4,581 hrs · 3,469 cycles

PILOTS REPORTED AFT FLOOD AIR CONDITIONING FAN INOP. FOUND THE AFT EVAPORATOR BLOWER MOTOR SEIZED. AFT EVAPORATOR BLOWER WHEEL HAD 1 FIN MISSING AND 6 DAMAGED, BLOWER WHEEL SLIGHTLY WARPED. R&R AFT EVAPORATOR BLOWER MOTOR AND BLOWER WHEEL WITH NEW. OPS CHECK GOOD.

Source: SDR 3NXA20230711004
OTHER · 2023-05-09 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (ZONE 600)

DURING SERVICE CHECK, FOUND OVER WING EMERGENCY LIGHT INOPERATIVE. FOUND SOCKET WAS LOOSE WITHIN ASSEMBLY. R&R OVER WING LIGHT WITH NEW LED OVER WING LIGHT P/N OWL100-03, OPS CHECK GOOD. WORK PERFORMED IAW 525B AMM 33-50-00

Source: SDR 2023FA0000273
OTHER · 2023-04-03 Matched by certificate designator
ATA 5210

Part: TRIGGER — BINDING · airframe 4,471 hrs · 3,386 cycles

AFTER FLIGHT, CREW ATTEMPTED TO EXIT AIRCRAFT THROUGH THE NORMAL BOARDING DOOR BUT THE TRIGGER TO RELEASE THE HANDLE WOULD NOT ACTUATE. CREW FROM OUTSIDE USED THE OUTSIDE DOOR HANDLE TO OPEN DOOR AND ALLOW CREW TO EXIT. IT WAS FOUND THAT THE TRIGGER EXTENSION PIECE ON THE TOP OF THE TRIGGER BROKE OFF AND WAS JAMMING THE TRIGGER, NOW ALLOWING IT TO FUNCTION PROPERLY. TRIGGER WAS REPLACED, OPS CHECK GOOD

Source: SDR 2023FA0000189