N919DU
Registered owner: DELTA AIR LINES INC, GA (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
7 reports on file, 2019-12-05 – 2026-10-29.
Part: CONTROLLER — FAILED (CABIN PRESSURE) · airframe 24,087 hrs · 9,642 cycles
DECLARED AN EMERGENCY DUE TO AUTO PRESSURIZATION FAIL ON CLIMB OUT. REPLACED CPC 2 AND PERFORMED CONFIDENCE CHECK OF BOTH PACKS. OPS CHECKS GOOD. (9535902) AIRCRAFT WAS GROUNDED
Part: BATTERY PACK — INOPERATIVE (ZONE 200) · airframe 23,929 hrs · 9,566 cycles
EMERGENCY LIGHTS INOP AT SEAT ROWS 1-5CD. R & R BATTERY PACK IAW AMM 33-51. OPS CHKD GOOD. (9522032) AIRCRAFT WAS GROUNDED
Part: VALVE — ODOR (ZONE 100) · airframe 23,143 hrs · 9,199 cycles
FUMES EVENT PILOT AND F/A BEGAN TO DETECT AN ODOR DURING CLIMB OUT ABOUT 28000. FUMES CHECKLIST INITIATED AND ODOR DISSAPATED, ODOR DISAPPATED AFTER LEAVING CLOUDS AND A/I OFF. ALSO NOTICED P6-4 01 CIRCUIT POPPED. FOUND OVERBOARD EXHAUST VALVE CIRCUIT BREAKER POPPED. R & R OVERBOARD EXHAUST VALVE IAW AMM 21-27. OPS CHKD GOOD NO BURNING ODORS, LOG #1687227. (8721304) AIRCRAFT WAS GROUNDED.
Part: BATTERY PACK — INOPERATIVE (ZONE 200) · airframe 22,162 hrs · 8,782 cycles
(LOG 8252137) EMERGENCY LIGHTS IN ROWS 28-32 ARE OUT. R+R BATTERY PACK M2627 PER B737 AMM 33-51. ALL LIGHTS ILLUMINATE, OK FOR SERVICE.
Part: POWER SUPPLY — INOPERATIVE · airframe 12,914 hrs · 5,160 cycles
(LOG 4661084) DURING SVC CHECK FOUND EEPLS (EMERGENCY SEAT LIGHTS) ROW 33 THROUGH ROW 37 NOT WORKING. REPLACED POWER SUPPLY PER B737 AMM 33-51-06. OPS CHECK NORMAL A/C OK FOR SVC.
Part: BATTERY PACK — INOPERATIVE · airframe 12,623 hrs · 5,022 cycles
(LOG 4027885) DURING INSPECTION FOUND 2R EMERGENCY EXIT SIGN INOP. REPLACED BATTERY AND FUSE AT POWER SUPPLY M1672 PER B737AMM 33-51. OPS TEST GOOD.
Part: LENS — MISSING (WARNING PANEL) · airframe 2,873 hrs · 1,135 cycles
(LOG 6701524) DURING INSPECTION FOUND DOOR WARNING PANEL MISSING LENS COVER. REPLACED LENS COVER CKS NML.