N921GL

SIKORSKY S-92A · 2013 · Rotorcraft · 1 engine · 19 seats · Valid Registration

Registered owner: CHEVRON U S A INC, MS (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
CHEVRON USA PRODUCTION COMPANY (AC2A)Certificate holder—Matched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

5 reports on file, 2013-12-01 – 2024-03-19.

OTHER · 2024-03-19 Matched by certificate designator
ATA 6320

Part: BUSHING — CRACKED (MOUNT) · airframe 8,318 hrs · 3,790 cycles

THREE OF THE BUSHINGS ON THE RH MOUNTING FOOT WAS FOUND TO BE FRACTURED.

Source: SDR AC2R921GL03192024
OTHER · 2019-03-09 Matched by certificate designator
ATA 6730

Part: SERVO — WORN (MAIN ROTOR) · airframe 5,220 hrs

BEARINGS, LINKAGE AND SLINED PIVOT SHAFT WORN.

Source: SDR AC2R2019060549203
OTHER · 2017-03-02 Matched by certificate designator
ATA 6720

Part: ROD END — DAMAGED (TAIL ROTOR PCS) · airframe 3,497 hrs

FOUND TAIL ROTOR PITCH CHANGE SHAFT (PCS)- INPUT CONTROL TUBE ROD END BEARING OUTER RING WAS NO LONGER SECURE IN THE ROD END. ONCE THE ROD END WAS REMOVED FROM THE PCS, THE BEARING DID NOT HAVE ANY RESISTANCE TO KEEP IT INSTALLED INTO RODEND. THE ROD END WAS REPLACED WITH NEW.

Source: SDR AC2R2017031001
OTHER · 2015-05-17 Matched by certificate designator
ATA 6730

Part: SERVO — WORN (MAIN ROTOR) · airframe 1,823 hrs

BEARINGS, LINKAGE AND SLINED PIVOT SHAFT WORN.

Source: SDR AC2R2019060549201
OTHER · 2013-12-01 Matched by certificate designator
ATA 6220

Part: DAMPER — DETERIORATED (ZONE 400) · airframe 209 hrs

BLUE MAIN ROTOR DAMPER OTBD BARREL NUT FOUND DAMAGED ON DAILY INSPECTION. REMOVED FAULTY BLUE DAMPER ASSEMBLY, PN 92106-15801-103 AND INSTALLED NEW DAMPER ASSEMBLY OF SAME PN. INSPECTED ALL OTHER DAMPERS IN SERVICE AND REPORTED INCIDENT TO TECHNICAL REPRESENTATIVE AND INSPECTION DEPARTMENT.

Source: SDR AC2A201312040001