Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

17 reports on file, 1995-10-22 – 1995-10-27.

OTHER · 1995-10-27 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 7580)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 7580. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500897
OTHER · 1995-10-26 Matched by certificate designator
ATA 5320

Part: INTERCOSTAL — CORRODED (BS 6120)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 6120. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500896
OTHER · 1995-10-26 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 7580)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 7580. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500911
OTHER · 1995-10-26 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 6600)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 6600. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500902
OTHER · 1995-10-25 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 6120)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 6120. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500901
OTHER · 1995-10-25 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 6600)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 6600. REPAIRED I/A/W ABX REA Y153 13193-MR.

Source: SDR ABXA9500903
OTHER · 1995-10-25 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 4680)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 4680. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500899
OTHER · 1995-10-25 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 4680)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4680. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500910
OTHER · 1995-10-25 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 8080)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 8080. REPAIRED I/A/W ABX REA Y153 13193-MR.

Source: SDR ABXA9500904
OTHER · 1995-10-25 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 4680)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4680. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500912
OTHER · 1995-10-24 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 4200)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A LONGITUDINAL FLOOR BEAM AT STA 4200. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500898
OTHER · 1995-10-24 Matched by certificate designator
ATA 5311

Part: FRAME — CORRODED (BS 8080)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FUSELAGE FRAME AT STA 8080 BETWEEN LONGERONS 30LT TO 28RT. REPAIRED I/A/W YS-11 SRM 53-3-2.

Source: SDR ABX9500905
OTHER · 1995-10-24 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 4200)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4200. REPAIRED I/A/W ABX REA Y153 13209-MR.

Source: SDR ABXA9500900
OTHER · 1995-10-23 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 3240)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 3240. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500907
OTHER · 1995-10-23 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 3240)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 3240. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500909
OTHER · 1995-10-23 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 4200)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 4200. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500908
OTHER · 1995-10-22 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 5160)

DURING C-CHECK INSPECTION, CORROSION WAS FOUND ON A FLOOR BEAM AT STA 5160. REPAIRED I/A/W ABX REA Y153 13211-MR.

Source: SDR ABXA9500906