N9242Y

BOEING 737-8AS · 2001 · Fixed-wing multi-engine · 2 engines · 149 seats · Valid Registration

Registered owner: UMB BANK NA TRUSTEE, UT (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

3 reports on file, 2024-07-18 – 2024-11-30.

FALSE WARNING · 2024-11-30 Matched by certificate designator
ATA 5230

Part: SWITCH — OUT OF POSITION (ZONE 800) · airframe 50,189 hrs · 38,565 cycles

MAIN CARGO DOOR LIGHT ILLUMINATED PASSING FL 33 EXTINGUISHED PASSING 9500 FT AND REMAINED OFF FOR THE DURATION OF THE FLIGHT. ADJUSTED FWD DOOR CLOSED SWITCH IAW B737 IAI SUP MANUAL 52-70-00, OPS CHECK GOOD NO DEFECTS NOTED. AIRCRAFT OK FOR SERVICE.

Source: SDR K11A2024113000293
WARNING INDICATION · 2024-09-24 Matched by certificate designator
ATA 2820

Part: FUEL FILTER — FAULTED (NR 1) · airframe 50,143 hrs · 38,534 cycles

ON CLIMB OUT THE #1 ENGINE FUEL FILTER BYPASS LIGHT ILLUMINATED THEN WENT OUT CONTINUED TO CLIMB AND LIGHT ILLUMINATED AGAIN. REMOVED AND REPLACED #1 ENGINE FUEL FILTER IAW B737-800 AMM 73-11-02 FROM STEP A-G, PERFORMED LEAK IAW B737-800 AMM 73-11-02 STEP H. LEAK CHECK GOOD, OPS CHECK GOOD.

Source: SDR K11A2024092400287
FALSE WARNING · 2024-07-18 Matched by certificate designator
ATA 3414

Part: INDICATOR — FAULTED (AIRSPEED) · airframe 50,089 hrs · 38,489 cycles

ON TAKEOFF CAPT. AIRSPEED READ 45 WHEN FO CALLED 80 KTS. THEN CAPT. AIRSPEED JUMPED TO 85 KTS. THE AUTO THROTTLES DISCONNECTED AT 85 KTS FO TRIED TO RECONNECT THE AUTO THROTTLES BUT COULD NOT GET THEM TO ENGAGE. CAPT. ABORTED TAKEOFF AT 110 KTS, 5500 FT OF RUNWAY REMAINING. PERFORMED AUTO THROTTLE SYSTEM OPS CHECK IAW AMM 22-31-00, OPS CHECK GOOD NO DEFECTS NOTED. INSPECTED L&R PITOT PROBES PER AMM 34-11-01 PROBES CHECK GOOD IAW AMM 34-11-01, LP 8519 PERFORMED LEAK CHECK OF L&R PITOT PROBES IAW AMM 34-11-00 LEAK CK GOOD IAW AMM 34-11-00, REMOVED & CLEANED BOTH L&R PITOT PROBES IAW AMM 34-11-01 LEAK CK GOOD IAW AMM 34-11-00 BITE CK GOOD IAW AMM 34-21-00 AND FIM 34-21 TASK 801

Source: SDR K11A2024071800270