N928FR

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

60 reports on file, 2005-07-04 – 2016-04-08.

OTHER · 2016-04-08 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED CORROSION AT FRAME 66 & FLOORBEAM Y1292. R & R FLOORBEAM IAW SRM 51-42-11.

Source: SDR F3LA2016040800032
OTHER · 2016-04-08 Matched by certificate designator
ATA 5320

Part: DOOR SILL — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED CORROSION ON NUTPLATE HOLE ON L2 AFT GIRT BAR FITTING. R & R L2 DOOR SILL IAW SRM 51-72-11.

Source: SDR F3LA2016040800030
OTHER · 2016-04-08 Matched by certificate designator
ATA 5320

Part: FITTING — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED R1 DOOR AFT GIRT BAR FITTING HAS CORROSION. REPAIRED R1 DOOR GIRT BAR FITTING IAW SRM 51-73-00, SRM 51-74-00, NTM 51-10-08 & SRM 51-21-11.

Source: SDR F3LA2016040800029
OTHER · 2016-04-08 Matched by certificate designator
ATA 5320

Part: PLATE — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED CORROSION AT FRAME 66 & Y1732. PERFORMED REPAIR IAW SRM 53-41-14.

Source: SDR F3LA2016040800031
OTHER · 2016-04-04 Matched by certificate designator
ATA 5320

Part: FITTING — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED R1 DOOR AFT GIRT BAR FITTING HAS CORROSION. REPAIRED R1 DOOR AFT GIRT BAR FITTING IAW SRM 51-73-00, 51-74-00, 53-11-11, NTM 51-10-08 & SRM 51-21-11.

Source: SDR F3LA2016040800026
OTHER · 2016-04-04 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED CORROSION, BETWEEN FRAME 64 & 67, Y254. R & R FLOORBEAM IAW SRM 51-42-11 & SRM 51-72-1.

Source: SDR F3LA2016040800028
OTHER · 2016-04-04 Matched by certificate designator
ATA 5320

Part: SHEAR PLATE — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED RT SHEAR PLATE, BETWEEN STRINGER 23 & 24, AT FRAME 68 - 70 HAS CORROSION. R & R SHEAR WEB & WEB SUPPORT IAW SRM 51-42-11.

Source: SDR F3LA2016040800027
OTHER · 2016-04-04 Matched by certificate designator
ATA 5320

Part: SHEAR PLATE — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED LT AFT SHEAR PLATE, BETWEEN STRINGER 23 & 24 AT FRAME 68 & 70 HAS CORROSION. R & R LT AFT SHEAR PLATE IAW SRM 51-42-11 & SRM 51-44-11.

Source: SDR F3LA2016040800025
OTHER · 2016-03-31 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED CORROSION AT FRAME 66 & Y1292. R & R THE FLOORBEAM AT FRAME 66 & Y1292 IAW SRM 51-42-11.

Source: SDR F3LA2016040800024
NO TEST · 2016-03-23 Matched by certificate designator
ATA 3397

Part: SPLICE — DAMAGED (CABIN) · airframe 41,683 hrs · 20,630 cycles

DURING C CHECK, NOTED THE RT EMER EXIT LOWER FWD EXIT LIGHT INOPERATIVE. REPAIRED THE SPLICE IAW ESPM 20-43-13. OPERATIONAL CHECKED GOOD.

Source: SDR F3LA2016040800023
Earlier reports · 2005–2014 · 50 reports

2014

NO TEST · 2014-09-14 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — FAILED (CABIN) · airframe 35,836 hrs · 17,814 cycles

FORWARD LT EPSU FAILS EMER LIGHTS TEST. R & R FWD LT EPSU 10WL. OPERATIONAL CHECKED NORMAL IAW AMM 33-51-38 PAGE BLOCK 401.

Source: SDR F3LA2014091501072
WARNING INDICATION · 2014-08-08 Matched by certificate designator
ATA 3610

Part: VALVE — CLOSED (BLEED AIR SYS) · airframe 35,480 hrs · 17,606 cycles

IN CRUISE AT 31000 FT UNABLE TO MAINTAIN CABIN PRESS. CABIN ALTITUDE ROSE TO 10,200. R & R NR 2 ENG PRV IAW AMM 36-11-52-PB 401. OPERATIONS & LEAK CHECKED VLV & NO LEAKS NOTED. PREFORMED OPERATIONAL TEST OF THE BLEED AIR SYS IAW AMM 36-11-00-710-003-A. OPERATIONAL TESTED GOOD.

Source: SDR F3LA2014081201050
OTHER · 2014-06-12 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN) · airframe 34,905 hrs · 17,292 cycles

L1 DOOR EMER POWER SUPPLY UNIT INOPERATIVE 10WL. R & R L1 DOOR EMER POWER SUPPLY UNIT. OPERATIONS CHECKED GOOD IAW AMM 33-51-38 PB 401.

Source: SDR F3LA2014061601042

2013

OTHER · 2013-05-08 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 200) · corrosion level 2 · airframe 31,463 hrs · 15,437 cycles

DURING C6 CHECK. AFT GALLEY FLOORBEAM AT FRAME 69 HAS LIGHT CORROSION AROUND FASTENER HOLE. CLEANED UP HOLE TO .354' IAW SRM 53-41-14, FIGURE 101, SRM 51-21-11 (4)(C) AND SRM 51-75-12. VERIFIED CORROSION REMOVAL WITH HPEC IAW NTM 51-10-02 B NOTE 3. NO FURTHER INDICATIONS WERE NOTED. ACFT IS SCHEDULED FOR RETURN TO SERVICE.

Source: SDR F3LA2013052200859
OTHER · 2013-05-08 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 200) · corrosion level 2 · airframe 31,463 hrs · 15,437 cycles

ACFT WAS OUT OF SERVICE DUE TO C6 MX CHECK. AFT GALLEY FLOORBEAM AT FRAME 66, Y765 HAS LIGHT CORROSION AROUND FASTENER HOLE. R & R FLOORBEAM IAW SRM 51-42-11. PARA 5. ACFT IS SCHEDULED FOR RETURN TO SERVICE.

Source: SDR F3LA2013052200857
OTHER · 2013-05-08 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (ZONE 200) · corrosion level 2 · airframe 31,463 hrs · 15,437 cycles

DURING C6 CHECK. AFT GALLEY FLOORBEAM AT FRAME 66 APPROX Y1292 HAS LIGHT CORROSION. R & R FLOORBEAM IAW SRM 51-42-11, PARA 5 AND 6.B. ACFT SCHEDULED TO GO BACK INTO SERVICE.

Source: SDR F3LA2013052200858
NO TEST · 2013-05-06 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (EMERGENCY LIGHT) · airframe 31,453 hrs · 15,430 cycles

EPSU, MIDDLE RIGHT, BATTERY FAILED TEST ON HEAVY SERVICE CHECK. R & R BATTERY ASSY MIDDLE RIGHT EPSU. OPS CHECK GOOD. REF AMM 33-51-38 PAGE BLOCK 401.

Source: SDR F3LA2013050800850

2011

NO TEST · 2011-09-11 Matched by certificate designator
ATA 3350

Part: LAMP — BURNED OUT (EMERGENCY LIGHT) · airframe 26,268 hrs · 12,804 cycles

OVERWING EMERGENCY LIGHT 60WL HAD AFT BULB INOPERATIVE. RELAMPED EMERGENCY LIGHT 60WL IAW AMM 33-51-15 PB 401. OPS CHECKED GOOD.

Source: SDR F3LA2011091300670
WARNING INDICATION · 2011-01-31 Matched by certificate designator
ATA 2913

Part: PUMP — FAILED (HYD SYSTEM) · airframe 24,134 hrs · 11,746 cycles

YELLOW HYD FLUID & SYSTEM LOST ON APPROACH. R & R RT ENGINE HYD PUMP IAW AMM 29-13-51- PB 407. LEAK & OPS CHECKS OK.

Source: SDR F3LA2011021000599

2010

SMOKE/FUMES/ODORS/SPARKS · 2010-06-27 Matched by certificate designator
ATA 2330

Part: ENTERTAIN SYS — SMOKE (CABIN) · airframe 22,009 hrs · 10,732 cycles

REFERENCE LOG PAGE 529827 ITEM 1 AND LOG PAGE 529836 ITEM 1. SEAT 13A TV SMELLS HOT AND WAS SMOKING. INSPECTED ROW 13 ABC FOR SMOKE AND INSPECTED EPSU'S. NO DEFECTS NOTED. PERFORMED ELECTRICAL ODOR SYSTEM INTEGRITY CHECK IAW LIVE TV AMM 44-25-00 PAGE 5042 THRU 5047. FOUND NO EVIDENCE OF ELECTRICAL BURNING. REPLACED SEB AT SEATS 13 ABC AND VDU FOR PRECAUTIONARY.

Source: SDR F3LA2010063000445
FALSE WARNING · 2010-06-03 Matched by certificate designator
ATA 2611

Part: COMPUTER — MALFUNCTIONED (SMOKE WARNING) · airframe 21,758 hrs · 10,619 cycles

PILOT REPORT REF LOG PAGE 524666 ITEMS 1 AND 2. SMOKE WARNING ACTUATED UPON LANDING. NO SMOKE NOTICED IN COCKPIT. BOTH BLOWER AND EXTRACT FAULTED AT SAME TIME ON THE VENTILLATION SYS. R & R AEVC COMPUTER.

Source: SDR F3LA2010060400435
NO TEST · 2010-03-22 Matched by certificate designator
ATA 3350

Part: EPSU — INOPERATIVE (ZONE 200) · airframe 21,086 hrs · 10,309 cycles

DURING C4 S1 CHECK, INSP NOTED EMERGENCY LIGHTS ON SEATS 6C, 12C, AND 13C INOPERATIVE. MX TROUBLESHOT SYS IAW TSM 33-51-00-810-813, DISCONNECTED EACH EPSU, CLEANED / DRIED THE PLUGS, AND RECONNECTED. OPS TEST NORMAL IAW AMM 33-51-00-710-009.

Source: SDR F3LA2010032800376
OTHER · 2010-03-18 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — DELAMINATED (CARGO BAY) · airframe 21,086 hrs · 10,309 cycles

DURING C4 S1 CHECK INSP NOTED AFT CARGO PIT FLOOR PANEL 152UG DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW MCGILL 9701 REV. G

Source: SDR F3LA2010032700373
OTHER · 2010-03-16 Matched by certificate designator
ATA 5320

Part: COVER — CORRODED (ZONE 100) · airframe 21,086 hrs · 10,309 cycles

DURING C4 S1 CHECK, INSP NOTED AFT CARGO COMPARTMENT DOOR CUTOUT THRESHOLD AREA COVER SHEET CORRODED. MX R & R AFT CARGO COMPARTMENT DOOR CUTOUT THRESHOLD AREA COVER SHEET IAW SRM 51-42-11 AND 51-72-11.

Source: SDR F3LA2010032800375
OTHER · 2010-03-15 Matched by certificate designator
ATA 5320

Part: SHEAR WEB — CRACKED (FUSELAGE) · airframe 21,086 hrs · 10,309 cycles

DURING C4 S1 CHECK INSP NOTED SHEAR WEB AT FRAME 69 AT AFT END OF BEAM -Y1292 HAS A FIFTEEN INCH CRACK. R & R SHEAR WEB IAW EO A0-53-31934 AND A319 SRM 51-72-11.

Source: SDR F3LA2010032700372
OTHER · 2010-03-15 Matched by certificate designator
ATA 5321

Part: FLOORBOARD — DELAMINATED (ZONE 100) · airframe 21,086 hrs · 10,309 cycles

DURING C4 S1 CHECK INSP, NOTED AFT CARGO FLOOR PANEL 151TG PUNCTURED AND DELAMAINATED BEYOND ECONOMICAL LIMITS. MX R & R IAW AMM 53-12-14-400-001.

Source: SDR F3LA2010032700370
OTHER · 2010-03-15 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · airframe 21,086 hrs · 10,309 cycles

DURING C4 S1 INSP NOTED FLOORBEAM -Y765 BETWEEN FRAME 67 AND FRAME 68 HAD CORROSION ON UPPER SURFACE. REPAIRED FLOORBEAM IAW SRM 53-00-14 PARAGRAPH 4 D FIGURE 204.

Source: SDR F3LA2010032700371
OTHER · 2010-03-15 Matched by certificate designator
ATA 5320

Part: SHEAR WEB — CRACKED (FUSELAGE) · airframe 21,086 hrs · 10,309 cycles

REFERENCE NON ROUTINE N0014 AFT CABIN SHEAR WEB AT FRAME 69 AT AFT END OF BEAM =Y1292 HAS A CRACK. R & R SHEAR WEB IAW EO A0-53EO-31434 AND SRM 51-72-11.

Source: SDR F3LA2010032700374

2009

WARNING INDICATION · 2009-01-01 Matched by certificate designator
ATA 5230

Part: COVER — DEFECTIVE (CARGO DOOR) · airframe 16,779 hrs · 8,160 cycles

PILOT MADE AN AIR TURNBACK DUE TO AN AFT CARGO DOOR MESSAGE ON THE ELECTRONIC CENTRALIZED ACFT MONITORING SYS. MX REMOVED AND REPLACED THE COVER ASSY AND PERFORMED OPERATIONAL CHECK IAW AMM 52-32-21-420-052.

Source: SDR F3LA2009010500001

2008

OTHER · 2008-08-26 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — CORRODED (FUSELAGE) · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE CO50125. DURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 261PF HAS A CORRODED INSERT ON THE LT HAND SIDE AND DELAMINATION IN THE SAME AREA. MX REPAIRED PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9-53R-30588. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800588
OTHER · 2008-08-23 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE CO50117. DURING C3 C-CHECK, INSP NOTED LT FLOORBEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM FRAME 66 TO FRAME 68 (L2 DOOR AREA). MX R&R THE FLOORBEAM IAW THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR 19-53R-30587. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800584
OTHER · 2008-08-23 Matched by certificate designator
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE CO50117. DURING C3 C-CHECK, INSP NOTED LT FLOOR SUPPORT Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM FRAME 66 TO FRAME 68 (L2 DOOR AREA). MX R&R THE FLOOR SUPPORT IAW THE REQUIREMENTS OF EA NR A9-53R-30587. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800585
OTHER · 2008-08-22 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE CO50040. DURING C3 C-CHECK, INSP NOTED FLOOR BEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM RT HAND FRAME 67 TO FRAME 68. MAINTENANCE INSTALLED NEW FLOOR BEAM IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11 AND ENGINEERING AUTHORIZATION # A9-53R-30392. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800583
OTHER · 2008-08-22 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE CO50039. DURING C3 C-CHECK, INSP NOTED FLOOR BEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM RT HAND FRAME 66 TO FRAME 67. SUPPLEMENTAL INFORMATION WILL BE PROVIDED AS SOON AS CORRECTIVE ACTION INFORMATION BECOMES AVAILABLE. MX R&R FLOORBEAM IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-41-14, 51-42-00 AND 51-42-11, PAGE 24. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800582
OTHER · 2008-08-22 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE C050039. DURING C3 C-CHECK, INSP NOTED FLOOR BEAM Y1292 HAS CORROSION IN VARIOUS NUT CLIP HOLES FROM RT HAND FRAME 66 TO FRAME 67. SUPPLEMENTAL INFORMATION WILL BE PROVIDED AS SOON AS CORRECTIVE ACTION INFORMATION BECOMES AVAILABLE. (OPEN)

Source: SDR F3L2008F00004
OTHER · 2008-08-22 Matched by certificate designator
ATA 5320

Part: SHEAR PLATE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE C050055. DURING C3 C-CHECK, INSP NOTED INDICATIONS OF CORROSION ON TOP OF RIGHT AFT SHEAR PLATE BETWEEN FRAME 68 AND FRAME 70. MAINTENANCE REMOVED AND REPLACED SHEAR PLATE ASSEMBLY IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 51-42-11, PARAGRAPH 6. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3L2008F00003
OTHER · 2008-08-22 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — DAMAGED (FUSELAGE) · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE C049995. DURING C3 C-CHECK INSPECTION NOTED THE FORWARD OUTBOARD CORNER WAS DAMAGED ON FLOOR PANEL 242LF. MX REPAIRED DAMAGE TO PANEL 242LF IN ACCORDANCE WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9-53R-30577. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800580
OTHER · 2008-08-21 Matched by certificate designator
ATA 5320

Part: SHEAR PLATE — CORRODED (FUSELAGE) · corrosion level 2 · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED THE LT LATERAL SHEAR PLATE HAS LIGHT CORROSION AT CLIP NUT HOLES BETWEEN FR 68 AND FR 70. MAINTENANCE REMOVED AND REPLACED SHEAR PLATE IAW THE REQUIREMENTS OF A319 SRM 51-42-11, PARAGRAPH 6. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800579
OTHER · 2008-08-21 Matched by certificate designator
ATA 5320

Part: SILL — CORRODED (FUSELAGE) · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE CO50131. DURING C3 C-CHECK, INSPECTION NOTED NUT PLATE HOLE ON R-2 DOOR SILL, AFT AND OUTBOARD OF R-2 AFT GIRT BAR ATTACH FITTING WAS CORRODED. MX INSTALLED REPAIR DOUBLER IN ACCORDANCE WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9-53R-30582. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800586
OTHER · 2008-08-21 Matched by certificate designator
ATA 5240

Part: SEAL — CORRODED (R2 DOOR) · airframe 15,560 hrs · 7,529 cycles

REFERENCE NON ROUTINE C050131. DURING C3 C-CHECK, INSPECTION NOTED NUT PLATE HOLE ON R-2 DOOR SEAL, AFT AND OUTBOARD OF R-2 AFT GIRT BAR ATTACH FITTING WAS CORRODED. SUPPLEMENTAL INFORMATION WILL BE PROVIDED AS SOON AS CORRECTIVE ACTION INFORMATION BECOMES AVAILABLE. (OPEN)

Source: SDR F3L2008F00002
OTHER · 2008-08-20 Matched by certificate designator
ATA 5320

Part: BLANKING PLATE — CORRODED (GIRT BAR) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED R1 FORWARD GIRT BAR BLANKING PLATE HAS CORROSION AT HOLES. MAINTENANCE FABRICATED NEW NUT PLATE ASSEMBLY FOR GIRT BAR BLANKING PLATE AND INSTALLED IAW THE REQUIREMENTS OF AIRBUS DRAWING D531 12534 AND A319 SRM 51-42-11, PARAGRAPH 7. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800577
OTHER · 2008-08-20 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED THE FORWARD PIT PANEL 132EG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURED DAMAGE TO FLOOR PANEL IN ACCORDANCE WITH A319 SRM 53-02-00, FIGURE 204.

Source: SDR F3LA200800578
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152TG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 152TG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800570
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 151UG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 151UG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800573
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 161BF WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 161BF IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800576
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 162CF WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 162CF IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800575
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152UG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 152UG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800569
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152WG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 152WG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800572
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 152XG WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO TRANSITION PANEL 152XG IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800571
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED FORWARD PIT PANEL 131CF WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 131CF IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800568
OTHER · 2008-08-19 Matched by certificate designator
ATA 5321

Part: FLOOR PANEL — PUNCTURED (CARGO BAY) · airframe 15,560 hrs · 7,529 cycles

DURING C3 C-CHECK, INSPECTION NOTED AFT PIT PANEL 151BE WAS DAMAGED. MAINTENANCE REPAIRED PUNCTURE DAMAGE TO PANEL 151BE IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)

Source: SDR F3LA200800574
WARNING INDICATION · 2008-05-07 Matched by certificate designator
ATA 2611

Part: SMOKE WARNING — ACTIVATED (ZONE 100) · airframe 14,463 hrs · 6,962 cycles

AFTER ENGINES WERE SHUTOFF, THE CREW REPORTED THE LIVE TV SMOKE ALARM WENT OFF AND MAIN TV POWER SWITCH WAS PUSHED TO OFF AND ALARM WAS SILENCED. MAINTENANCE PERFORMED VISUAL INSPECTION OF LIVE TV AVIONICS COMPARTMENT AND FOUND NO DAMAGE AND NO SIGNS OF SMOKE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF TCM 24-00-00-810-823. UPON COMPLETION THE WORK IT WAS INSPECTED AND FOUND ACCEPTABLE AND THE AIRCRAFT WAS RETURNED TO SERVICE.

Source: SDR F3LA200800237
OTHER · 2008-04-11 Matched by certificate designator
ATA 3350

Part: EPSU — INOPERATIVE (EMERGENCY LIGHTS) · airframe 14,166 hrs · 6,823 cycles

DURING RON SERVICE, INSPECTION REPORTED EMERGENCY EXIT PATH LIGHTING AT SEATS 6 ABC DID NOT ILLUMINATE. MAINTENANCE REMOVED AND REPLACED EPSU 10WL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 33-51-38 PB 401. UPON COMPLETION OF THE INSTALLATION THE LIGHTS TESTED OKAY.

Source: SDR F3LA200800150
VIBRATION/BUFFET · 2008-03-17 Matched by certificate designator
ATA 7230

Part: BEARING — FAILED (NR 1 ENGINE) · airframe 13,927 hrs · 6,706 cycles

DURING CRUISE, FLIGHT CREW REPORTED VIBRATION FOLLOWED BY ECAM WARNING OF NUMBER 1 ENGINE OIL FILTER CLOG, LOSS OF OIL PRESSURE, INCREASE IN OIL TEMPERATURE AND LOSS OF OIL LEVEL. THE ENGINE WAS SHUT DOWN, AN EMERGENCY WAS DECLARED AND THE AIRCRAFT LANDED SAFELY AT THE DIVERSION AIRPORT. PRELIMINARY ENGINEERING EVALUATION INDICATES POSSIBLE FAILURE OF THE NUMBER 3 BEARING IN THE COMPRESSOR SECTION OF THE ENGINE. ENGINE CHANGE WILL BE ACCOMPLISHED. DAMAGED ENGINE WILL BE SENT FOR TEARDOWN. WHEN TEAR DOWN REPORT IS AVAILABLE, THIS SDR WILL BE UPDATED. ENGINE CHANGE COMPLETED AND AIRCRAFT RETURNED TO SERVICE. DAMAGED ENGINE EN ROUTE TO GE (STROTHER FACILITY) FOR TEAR DOWN.

Source: SDR F3LA200800129
WARNING INDICATION · 2008-02-16 Matched by certificate designator
ATA 2432

Part: LIMITER — INOPERATIVE (BATTERY CHARGER) · airframe 13,604 hrs · 6,555 cycles

DURING TAKEOFF, THE FLIGHT CREW REPORTED AN ELAC BCL2 FAULT ON THE ECAM. THE FLIGHT CREW PERFORMED AN AIR TURN BACK AND AN UNEVENTFUL LANDING WAS ACCOMPLISHED. MAINTENANCE REMOVED AND REPLACED THE NUMBER 2 BATTERY CHARGE LIMITER IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 24-38-34-41. FOLLOWING COMPLETION OF THE INSTALLATION, THE UNIT WAS OPERATIONALLY TESTED AND FOUND OKAY. CORRECTED PART SERIAL NUMBER TO READ 2081/END.

Source: SDR F3LA200800055
NO TEST · 2008-02-12 Matched by certificate designator
ATA 3350

Part: EPSU — INOPERATIVE (EMERGENCY LIGHTS) · airframe 13,575 hrs · 6,542 cycles

DURING PERFORMANCE OF EO A9-25EO-02752, REV G, INSPECTION REPORTED EMERGENCY PATHWAY LIGHTS AT ROWS 1, 2, 5 AND 6 WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EPSU IN ACCORDANCE WITH THE REQUIREMENTS OF AMMM 33-51-38 PB 401. FOLLOWING COMPLETION OF THE MAINTENANCE ACTION, THE WORK WAS INSPECTED AND FOUND ACCEPTABLE.

Source: SDR F3LA200800048

2007

SMOKE/FUMES/ODORS/SPARKS · 2007-07-19 Matched by certificate designator
ATA 2120

Part: UNKNOWN — ODOR (CABIN) · airframe 11,393 hrs · 5,514 cycles

AIRCRAFT RT ROWS 9 AND 10 - BURNING WIRE SMELL AT 02 COMPARTMENT IN OVERHEAD BIN. HOT TO TOUCH. INSPECTED LIGHTS, WIRING AND PAX OXYGEN GENERATORS FOR ACCIDENTAL DISCHARGE. NO DEFECTS NOTED AT SEAT ROWS 9 AND 10 DEF. REPLACED PASSENGER READING LIGHT POWER UNITS AS A PRECAUTIONARY MEASURE AT ROWS 9 AND 10 DEF IAW AMM 23-73-38, PB 401. OPS CHECKED GOOD.

Source: SDR F3LA200700178

2006

SMOKE/FUMES/ODORS/SPARKS · 2006-06-21 Matched by certificate designator
ATA 2120

Part: ODOR — DETECTED (COCPIT) · airframe 11,683 hrs · 5,436 cycles

FLIGHT CREW REPORTED A BURNING SMELL, STRONG ELECTRICAL ODOR BRIEFLY WHILE DESCENDING THRU FL190. NO VISIBLE SMOKE OBSERVED. ODOR WAS ONLY NOTICED BY COCKPIT CREW. INSPECTED AIRCRAFT PER TSM 24-00-00-810-823 FOR DAMAGE. NO DAMAGE FOUND. PERFORMED TROUBLESHOOTING OF APU AND ENGINE PER TASK CARD. NO DAMAGE FOUND. UNABLE TO DUPLICATE DISCREPANCY. REPLACED THE RECIRCULATION FAN FILTER AS PRECAUTIONARY. NO OTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.

Source: SDR F3LA200600056
WARNING INDICATION · 2006-05-27 Matched by certificate designator
ATA 2432

Part: LIMITER — FAULTED (E/E BAY) · airframe 7,173 hrs · 3,392 cycles

AIR TURNBACK. FLIGHT CREW REPORTED BCL1 FAULT. RETURNED TO DEN AND LANDED WITHOUT INCIDENT. REPLACED BATTERY CHARGE LIMITER AT NR 1 POSITION. OPS CHECKED GOOD PER AMM 24-38-34, PAGE 401. ECAM STATUS NORMAL. PERFORMED OVERWEIGHT LANDING AT 140,300 LBS. NO EXCEEDANCES RECORDED.

Source: SDR F3LA200600027

2005

FLT CONT AFFECTED · 2005-07-04 Matched by certificate designator
ATA 2700

Part: ACTUATOR — UNSERVICEABLE (FLT CONTROLS) · airframe 3,937 hrs · 1,825 cycles

THS FAILED SECTION -A- OF TASK CARD TC 27400-1. THS LOCKED IN FULL NOSE DOWN POSITION. REPLACED THS ACTUATOR PER MM 27-44-51-400-001. PERFORMED REQUIRED SYSTEM TEST PER MM 27-41-00-730-001 AND CHECKED GOOD.

Source: SDR F3LA200500031