N930NK
Registered owner: BANK OF UTAH TRUSTEE, UT (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
51 reports on file, 2020-07-21 – 2024-12-05.
Part: UNKNOWN — ODOR (ZONE 200) · airframe 14,710 hrs · 6,198 cycles
DURING DESCENT THROUGH 18,000 FT. SMELLED A STRONG ODOR - HARD TO DESCRIBE, BUT NOT DIRTY SOCKS. WE SMELLED IT IN COCKPIT AND FA REPORTED SMELLING IT AS WELL. IT DISAPPEARED AFTER ABOUT 30-45 SECONDS.--
Part: A/C PACK — ODOR (NR 1) · airframe 14,611 hrs · 6,134 cycles
FUME EVENT FROM APPROACH ALL THE WAY TO LANDING, THRUST AT IDLE, PACKS ON BLEED ON, FUMES FELT ONLY IN THE FLIGHT DECK-PERFORMED T/S PER TSM 05-50-810-831, ODOR DISAPPEARED WITH PACK 1 TURNED OFF. REF LOG PAGE BELOW 3385444-2 FOR CORRECTIVE ACTION
Part: UNKNOWN — ODOR (CABIN) · airframe 14,591 hrs · 6,126 cycles
F/A'S REPORT DIRTY SOCK SMELL DESCENDING BETWEEN 4,000 - 5,000FT-ACCOMPLISHED TSM 05-50-00-810-831- FOR CABIN ODOR,BOTH PACKS RAN WITH APU BLEED WITH NO SIGNS OF CONTAMINATION.ENG BLEED ON BOTH ENGS WERE ISOLATED WITH NO SIGNS OF CONTAMINATION.BOTH PACKS & APU WERE INSPEWCTED WITH NO VISIBLE SIGNS OF OIL LEAKS OR CONTAMINATION.PERFORMED A DECONTAMINATION OF ECS REF 21-00-00 RR CONTINUATION ON LP 3385431-1
Part: UNKNOWN — ODOR (CABIN) · airframe 14,588 hrs · 6,124 cycles
BETWEEN 2000-3000 FT RIGHT BEFORE GET DEPLOYENT FAS SAID ODOR CAME INTO CABIN, PERSISTED THRU LANDIND AND GOT WORSE AFTER LANDING. STARTED GETTING BEFORE AFTER ENG 2 SHUTDOWN.-PERFORMED TSM 05-50-00-810-831-A, FOUND PACK #2 AT SOURCE.
Part: A/C PACK — ODOR (NR 1) · airframe 14,565 hrs · 6,115 cycles
DIRTY SOCK SMELL IN DESCENT ABOUT 12000FT TURN PACK 1 OFF AND NO SMELL NOTICED-RE OPENED MDDR 98075 TRANSFERRED MEL 21-52-01-15CAT C ORIGINAL DUE DATE 11/11/24 MX PROCEDURE C/W MOC # 66906 PLACARD INSTALLED
Part: UNKNOWN — ODOR (CABIN) · airframe 14,516 hrs · 6,086 cycles
DIRTY SOCK SMELL REPORTED ON FINAL APPROACH BY FLT ATTEND SMELL STRONGER IN AFT GALLEY MILD IN FWD GALLEY NO SMELL IN FLT DECK ( PACKS - A320 WITH MOD. 30626/MP K6443 (ENHANCED ECS) OR A321 WITH MOD. 157080/MP K17996 (PACK FLOW SELECTOR) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) )--
Part: A/C PACK — ODOR (NR 1) · airframe 14,493 hrs · 6,072 cycles
"ON APPROACH ""DIRTY SOCK' SMELL PRESENT. DESELECTED PACK 1 SMELL SLOWLY SUBSIDED -PERFORMED IDENTIFICATION OF THE CAUSE OF CABIN ODOR PER TSM 05-50-00-810-831-A. FOUND PACK #1 TO BE SOURCE OF CABIN ODOR. NO OTHER DISCREPANCIES NOTED AT THIS ITME.
Part: A/C PACK — ODOR (NR 1) · airframe 14,439 hrs · 6,040 cycles
STRONG "DIRTY SOCK" SMELL ON DESCENT AND FINAL APPCH. DESELECTED PACK 1 AND SMELL SEEMED TO DISSIPATE-REF TSM 05-50-00-810-831-A FOUND PACK #1 TO BE AT CAUSE OF AQE. PACK #1 REQ DEFERRAL SEE LP 3367049-2
Part: A/C PACK — ODOR (NR 1) · airframe 14,364 hrs · 6,006 cycles
DURING DESCENT SMELLED FOUL ODOR IN COCKPIT AND CABIN, AFTER SHUTTING OFF PACK ONE THE SMELL DISAPATED .SUSPECT PACK 1 ( PACKS - A320 WITH MOD. 30626/MP K6443 (ENHANCED ECS) OR A321 WITH MOD. 157080/MP K17996 (PACK FLOW SELECTOR) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) )--
Part: ECS — CONTAMINATED (ZONE 100) · airframe 14,363 hrs · 6,005 cycles
F/A'S REPORTED A SOCK SMELL ON FINAL APPROACH, THE SMELL DISIPATED AFTER LANDING-TROUBLESHOOTING DONE IAW TSM 05-50-00-810-831-A, SYSTEM DECONTAMINATION DONE IAW AMM 21-00-00-615-802-A, UNABLE TO DUPLICATE FUMES, NO FAULTS NOTED. A/C OK FOR SERVICE. MOC # 69159
Part: BOTTLE — LOW PRESSURE (DOOR ASSIST) · airframe 14,247 hrs · 5,954 cycles
L1 DOOR ASSIT BOTTLE BELOW LIMITS-SERVICED L1 DOOR ASSIST BOTTLE TO IAW AMM 52-10-00
Part: UNKNOWN — ODOR (CABIN) · airframe 14,106 hrs · 5,887 cycles
FUME EVENT OUT OF 10,000FT IDLE DECENT, SMELL UP FRONT ONLY--
Part: OIL SYSTEM — OVERSERVICED (ENGINES) · airframe 14,106 hrs · 5,887 cycles
FUME EVENT OUT OF 10,000FT IDLE DECENT, SMELL UP FRONT ONLY-REF L/P 3396752 # 1 & # 2 ENGINES OIL OVER SERVICED. PERFORMED DECONTAMINATION OF THE ENVIRONMENTAL CONTROL SYSTEM IAW AMM 21-00-00-615-803-A. NO FUMES NOTED AT THIS TIME
Part: BOTTLE — LOW PRESSURE (DOOR ASSIST) · airframe 14,029 hrs · 5,855 cycles
L1 PASSENGER DOOR ASSIST BOTTLE NEEDS SERVICING-SERVICED L1 PASSENGER DOOR IAW AMM 52-10-00 LEAK CHECK OK.
Part: FILTER — ODOR (CABIN AIR) · airframe 13,864 hrs · 5,780 cycles
AIR QUALITY EVENT-ACCOMPLISHED DECONTAMINATION OF ENVIRONMENTAL SYSTEM IAW AMM 21-00-00 RR RECIRCULATION FILTER IAW AMM 21-21-41 OPS CK MO DEFECT NOTED AT THIS TIME
Part: SLIDE — UNWANTED DEPLOY (R1 DOOR) · airframe 13,726 hrs · 5,723 cycles
DOOR R1 SLIDE DEPLOYED ( PILOT DEPLOYMENT)-DOOR R1 SLIDE REMOVED AND REPLACEDN PER AMM CH 25-62-44.OPS CHK GOOD, OK FOR SVC
Earlier reports · 2020–2023 · 35 reports
2023
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 10,218 hrs · 4,215 cycles
FUME EVENT ON DESCENT 10,000FT ENTIRE CABIN DIRTY SOCK SMELL-PERFORMED TSM 05-50-00-810-831-A IDENT OF CABIN ODOR. FOUND PACK 2 CAUSE FUME EVENT
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 10,163 hrs · 4,192 cycles
FA REPORT DIRTY SOCKS SMELL DURING DECENT IN FWD + MID A/C-PER TSM 05-50-00-810-831-A FOUND BOTH ENG OVERSERVICED OIL LEVEL WAS ADJUSTED TO THE PROPER LEVEL PER AMM 79-00-00, ALSO ACCOMPLISHED DECONTAMINATION OF THE ENVIROMENTAL CONTROL SYSTEM (ECS), PER AMM 21-00-00 WITH BOTH ENG RUNING, A/C OK TO CONTINUED IN SERVICE, NO SMELL AT THIS TIME NOTED.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 10,096 hrs · 4,166 cycles
DURING APPROACH FCT PTT B SMELLED THE DIRTY COCK SMELL FROM AFT GALLEY. SMELL WENT AWAY WITH PACK2 OFT.-PERFORMED OPS CHECK OF PACK 1 & 2 IAW AMM 21-52-32 NO ODOR DETECTED AIRCRAFT OOK FOR SERVICE
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 10,033 hrs · 4,139 cycles
ON FINAL APPROACH FLIGHT ATTENDANTS COMPLAINED ABOUT A CRAYON LIKE SMELL EMINATING THROUGHOUT THE CABIN-PERFORMED TSM 05-50-00-810-831-A TYPE 10 MISCELLANEOUS ODOR IDENTIFIED CABIN VENTED NO ODOR PRESENT A/C OK FOR SERVICE
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,988 hrs · 4,117 cycles
"ON DESCENT THRU 7000 FT FLT ATT REPORT DIRTY SOCK SMELL WITH INCREASING INTENSITY. PACK2 TURN OFF. FA'S REPORTED SMELL DECREASED. ALL ODOR IN AFT SECTION OF AIRCRAFT ( PACKS - A320 WITH MOD. 30626/MP K6443 (ENHANCED ECS) OR A321 WITH MOD. 157080/MP K17996 (PACK FLOW SELECTOR) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) )-REF LP # 3175007-2 & 3175008-2 & 3175009-2 FOR CORRECTIVE ACTION THIS CLEARS DMI PLACARD REMOVED MOC NOTIFIED LOG UPDATED"
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,983 hrs · 4,115 cycles
FAS REPORT ODOR OF MOLD AND DIRTY SOCKS UPON DESCENT -PERFORMED TSM 05-50-00-810-831A NO CABIN ODORS AT THIS TIME
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,964 hrs · 4,106 cycles
FA'S NOTICED ODOR AS WE STARTED DESCENT ODOR WAS DESCRIBED AS A WET BURNING SMELL. PILOTS DIDNT NOTICE ANY ODOR IN COCKPIT-PERFORMED TSM 05-51-00. PERFORMED INSPECTION OF ENGS & APU NO LEAKS NOTED OPERATED PACK NO ODOR. AC OK FOR SERVICE
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,958 hrs · 4,105 cycles
FUME EVENT IN CRUISE SMELLED BY FA'S AND PILOTS. RAN COM PROCEDURE FOR FUMES AND ISOLATED SYS #1 BY SHUTTING CROSSBLEED. CONDITIONS IMPROVED AND BLED #2 SUSPECTED AS POSSIBLE SOURCE. FUME EVENT CAME BACK DURING DESCENT. FOLLOWED COM PROCEDURES DESCENDED BELOW 10,000FT FOR RAT AIR VENT AND LANDED.-FOUND SOURCE OF CONTAMINATION APU OVERSERVICED. DRAINED APU OIL TO PROPER LEVEL IAW AMM 49-90-00. PERFORMED LEVEL C DECONTAMINATION OF THE ECS PACKS 1 AND 2 IAW AMM 21-00-00. NO FUMES. A/C OK FOR CONTINUED SVC
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,954 hrs · 4,103 cycles
F/A REPORT NASTY DIRTY SMELL AND ODOR IN BACK OF AIRCRAFT IN FLIGHT. DIVERTED TO KDEN-FOLLOWED TSM 05-00-00-810-831-A AMM 36-10-00, PERFORMED PACK 1 BURN, FOUND AFT GALLEY CART DEFERRED AND FULL OF TRASH , NO ODORS OR MUSTY SMELL FROM PACK 1, A/C IS OK FOR CONTINUED SVC
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,915 hrs · 4,091 cycles
ON DESCENT AT 14,000FT F/A'S REPORT ODOR/FUME EVENT-PERFORMED TSM 05-50-00-810-831-A, FOUND PACK 2 TO BE CAUSE OF CABIN ODOR. REF LP 3030677-2.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,870 hrs · 4,071 cycles
FA REPORTS DIRTY SOCK SMELL FOR ABOUT 11 MIN. PACK 2 ISOLATED. NO FURTHER ISSUE ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )--
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,828 hrs · 4,055 cycles
OUT OF 12000 FT FA SMELLED ODOR OF DIRTY SOCKS IN CABIN ON DESCENT QRM PROCEDURE COMPLETED & ODOR WENT AWAY -PERFORMED T/S PROCEDURE IAW AMM 05-50-01 FAULT ISOLATED TO NO 2 PACK
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,774 hrs · 4,033 cycles
FLIGHT ATTENDANT REPORTED DIRTY SOCK SMELL DECENDING THROUGH 6000FT ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )-PERFORMED DECONTAMINATION OF THE ECS IAW AMM 21-00-00. R/R RECIRCULATION FILTER (4012HM)(4013HM) IAW AMM 21-21-41. NO DEFECTS NOTED AT THIS TIME. THIS CLEARS MDDR 57081. MOC NOTIFIED PLACARD REMOVED.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,699 hrs · 4,003 cycles
ODOR/FUME ON APPROACH & AT GATE PACK 2 OFF SMELL WENT AWAY SUSPECT PACK 2-PERFORMED TSM 05-50-00-810-831-A FOUND PACK 2 TO BE THE SOURCE
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,553 hrs · 3,952 cycles
FUME EVENT ON DESCENT INTO LAX SHUT OFF PACK 2 AND DIRTY SOCK SMELL DISSIPATED-PERFORMED CHECKS IAW TSM 05-50-00-810-831-A, PACK WILL BE PLACED ON MEL. SEE L/P 2994066-1 FOR PACK 2 DEFERRAL.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,441 hrs · 3,912 cycles
FA REPORTED WET SOCKS SMELL DURING APPROACH-PERFORMED TSM 05-50-00 INSPECTION . NO ABNORMAL SCENTS NOTED. A/C RETURNED TO SVC
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,019 hrs · 3,764 cycles
LEAD FA SAYS MID CABIN A FUME EVENT HAPPENED-PERFORMED T/S PER TSM 05-50-00-810-831-A CAUSE OF FUME IS NB2 PACK REF LP 2956323 ITEM 2
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,066 hrs · 3,747 cycles
SUSPECTED FUME EVENT ON ARRIVAL. SMELL STARTED ON DECENT AND STOPPED AFTER TOUCH DOWN-PERFORMED GVI OF APU & ENGINES NO DEFECTS NOTED CONFIRMED ODOR ON PACK 2 REF. TSM 05-50-00-810-831 PERFORMED ECS CLEANING OF PACK 2 SYS USING APU AND ENGINES REF. AMM 21-00-00. PRECAUTIONARY R&R RECIRCULATION FILTERS REF. AMM 21-21-41. PRECAUTIONARY ACCOMPLISHED #1 & #2 ENG WASHES & APU STEAM CLEAN. NO ODORS NOTED AT THIS TIME. A/C OK FOR CONT SERVICE
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 9,035 hrs · 3,731 cycles
VERY STRONG FUME EVENT ON FINAL APPROACH. DIRTY SOCK SMELL OBSERVED BY FLIGHT CREW, FOWARD FA AND FIRST FIVE ROWS OF THE CABIN. ONE FLIGHT ATTENDANT SAID SHE SMELLED FUMES OFF AND ON DURING THE FLIGHT. PACK ONE WAS OFF DUE TO PREVIOUS DMI. -REF TSM 5-50-00-810-831-A AND FOUND APU OVER SERVICED. SERVICED APU TO PROPER LEVEL IAW AMM 12-13-49. PERFORMED PACK BURN-OUT IAW AMM 21-00-00. NO FUME ODOR IN CABIN DETECTED AT THIS TIME. A/C OK FOR CONT SVC.
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 8,982 hrs · 3,706 cycles
DURING CLIMB, MODERATE ODOR, LIKE WITCH HAZEL, IN FLIGHT DECK. TURNED PACK #1 OFF, ODOR DISIPATED. F/A REPORTED NO ODOR IN CABIN. AIR QUALITY REPORTING FORM COMPLETED ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED )--
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 8,320 hrs · 3,432 cycles
DURING EPSU SYSTEM TEST EPUS BATT IN FINS 10WL, AND 11WL FAILED.
Part: BATTERY — NO TEST (EMERGENCY LIGHTS) · airframe 8,320 hrs · 3,432 cycles
"DURING EPSU SYSTEM TEST EPSU BATT IN FINS 12WL AND 13WL FAILED.
2022
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 7,933 hrs · 3,286 cycles
PASSENGER DOOR L1 DOOR ASSIST BOTTLE NEED SERVICING -SERVICED PASSENGER DOOR L1 IAW AMM 52-10-00
Part: OIL SYSTEM — OVERSERVICED (APU) · airframe 7,737 hrs · 3,200 cycles
FUME EVENT IN FLIGHT AFT GALLEY ONLY NOTICED DIRTY SOCKS SMELL AFTER TAKEOFF DIVERTED TO BWI -PERFORMED TSM 05-50-00-810-831-A INSPECTED APU COMPARTMENT AREA FOUND APU OVER SERVICED REMOVED EXCESS OIL IAW AMM 12-13-49 PERFORMED ENG RUN FOR ENG 1 & 2 IAW AMM 71-00-00 WITH BOTH PACKS 1 & 2 ON COULD NOT DUPLICATE ODOR
Part: NONE — NONE · airframe 6,370 hrs · 2,650 cycles
L1 DOOR ASSIST BOTTLE NEEDS SERVICING -SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 5,405 hrs · 2,259 cycles
L1 DOOR ASSIST BOTTLE REQS SERVICING -SVCD L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00
2021
Part: NONE — NONE · airframe 4,148 hrs · 1,754 cycles
FOUND L1 DOOR ASSIST ACCUMULATOR LOW- SERVICED L1 DOOR ASSYST BTL ACCUMULATOR IAW AMM 52-10-00
Part: NONE — NONE · airframe 3,881 hrs · 1,638 cycles
FWD MEGAPHONE VOL KNOB MISSING-R/R FWD MEGAPHONE IAW AMM 25-65-00 OPS CHECK OK
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 2,582 hrs · 1,069 cycles
L1 DOOR ASSIST BOTTLE LOW-SVCD L1 DOOR ASSIST BOTTLE IAW AMM 52-11-00
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 1,739 hrs · 722 cycles
L1 DOOR ASSIST BOTTLE REQUIRES SERVICE-SERVICED L1 ASSIST BOTTLE IAW AMM 52-10-00.
Part: UNKNOWN — ODOR (CABIN) · airframe 1,488 hrs · 613 cycles
DIRTY SOCK SMELL REPORTED BY FORWARD AND AFT FLIGHT ATTENDANTS. PERFORMED TSM 05-50-00-810-931-A. ENGINES AND FUSELAGE WERE INSPECTED, NO EVIDENCE OF LEAKS. APU INSPECTED, NO LEAKS NOTED AND DUE TO BAD SMELL OF PACK NR 2, PLEASE SEE NEXT REPORT.
2020
Part: UNKNOWN — ODOR (CABIN) · airframe 1,040 hrs · 421 cycles
FLIGHT ATTENDANTS REPORTED SMELLING DIRTY SOCKS SMELL ON FINAL APPROACH INTO FLL, APU WAS OFF. PERFORM TSM 05-50-00-810-831-A PERFORM ENGINE RUN NR 1 & NR 2, PER AMM 71-00-00, NO SMELLS NOTED. AEROTRACER USED AND ANALYSIS TEST OK. ACCOMPLISHED GVI ENGINE NR 1 & NR 2, NO LEAKS OR DEFECTS NOTED. A/C OK FOR SERVICE.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 1,015 hrs · 410 cycles
L1 DOOR ASSIST BOTTLE NEEDS SERVICE. SERVICED L1 DOOR ASSIST BOTTLE, IAW AMM 52-10-00.
Part: UNKNOWN — ODOR (CABIN) · airframe 544 hrs · 229 cycles
AIR QUALITY EVENT. PERFORMED TSM 05-50-00 AND APPLIED DECISION TABLE TO ODOR REPORTING SHEET PROVIDED BY CREW. ENGINES AND APUS CHECKED FOR LEAKAGES , NONE NOTED. CAUSE OF ODOR ISOLATED TO THE LEFT PACK.
Part: BOTTLE — LOW PRESSURE (L1 DOOR ASSIST) · airframe 311 hrs · 144 cycles
L1 DOOR ASSIST REQUIRES SERVICING. SERVICED L1 DOOR ASSIST IAW AMM 52-10-00. LEAK CHECKED GOOD