N939AS

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

91 reports on file, 1995-01-21 – 2005-03-06.

PARTIAL RPM/PWR LOSS · 2005-03-06 Matched by certificate designator
ATA 7200

Part: ENGINE — MAKING METAL (LEFT)

DFW INFLIGHT T1304/6 MAR LOUD BAND AND SHUTTER. LEFT ENGINE LOST POWER. ROLLED BACK TO IDLE. ENGINE RAN AT IDLE UNTIL AFTER LANDING. ENGINE WAS SHUT DOWN AFTER LANDING. FOUND METAL IN TAILPIPE. REPLACED NUMBER ONE ENGINE. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20050184
OTHER · 2005-02-04 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT)

SFO - AFT TAIL CONE EMERGENCY LIGHT AND OVERHEAD EMERGENCY AISLE PATH LIGHT INOPERATIVE. REPLACED TWO EACH BATTERY PACKS ABOVE RIGHT HAND AFT LAV FOR TAIL CONE EMERGENCY LIGHT AND OVERHEAD EMERGENCY AISLE PATH LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20050081
OTHER · 2005-01-21 Matched by certificate designator
ATA 3350

Part: CHARGER — INOPERATIVE (EMERGENCY LIGHT)

DFW - AFT EMERGENCY LIGHTS BETWEEN AFT LAVS INOPERATIVE. REPLACED BATTERY PACKS AND TWO LIGHT BULBS FOR EMERGENCY LIGHTS BETWEEN AFT LAVS. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20050051
Earlier reports · 1995–2004 · 88 reports

2004

NO TEST · 2004-08-28 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT)

FIRST CLASS EMERGENCY LIGHTS ON OVERHEAD PANELS INOPERATIVE. REPLACED BATTERY PACK AND CHARGER FOR FIRST CLASS EMERGENCY LIGHTS ON OVERHEAD PANELS. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20040908
NO TEST · 2004-08-28 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT)

DFW - FORWARD CABIN EMERGENCY BYPASS LIGHTING INOPERATIVE. REPLACED BATTERY PACK FOR FORWARD CABIN EMERGENCY BYPASS LIGHTING. SYSTEM GROUND CHECKED NORMAL OPERATION.

Source: SDR AALA20040907

2003

OTHER · 2003-12-07 Unresolved
ATA 3350

Part: CONNECTOR — LOOSE (EMERGENCY LIGHTS) · airframe 46,253 hrs · 26,708 cycles

THE EGRESS LIGHTS WERE INOPERATIVE BETWEEN CABIN ROWS 27 AND 30. SECURED LOOSE CONNECTOR AT ROW 30. CHECK-C 11-23-03 STL. --CLOSED---

Source: SDR ZW0A0306501

2002

OTHER · 2002-11-22 Unresolved
ATA 5510

Part: BRACKET — CRACKED (HORIZONTAL STAB) · airframe 44,189 hrs · 25,408 cycles

BRACKET CRACKED INSIDE HORIZONTAL STABILIZER AT STA 1429 AND RBL 6. REPLACED ANGLE PER SPM 6-70-01 AND DOUGLAS DRAWING 5912188. LAST CHECK C PERFORMED IN STL 01/07/02 --CLOSED--

Source: SDR ZW0A021194
OTHER · 2002-11-21 Unresolved
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 44,189 hrs · 25,408 cycles

FLOOR TIE DOWN TRACK BETWEEN STRINGERS 27 AND 28 LT AND STA 1003 AND 1079 IN AFT AUX FUEL TANK HAS CORROSION. REPLACED TRACK SPLICE AND TRACK I.A.W. SRM 53-05-10R. LAST CHECK C PERFORMED IN STL 01/07/02 --CLOSED--

Source: SDR ZW0A021193
OTHER · 2002-11-20 Unresolved
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 44,189 hrs · 25,408 cycles

FLOOR SUPPORTS BETWEEN STA 160 AND STA 200 FOUND WITH SURFACE CORROSION. FABRICATED NEW SUPPORTS AND INSTALLED PER SRM 51-03-02. LAST CHECK C PERFORMED IN STL 01/07/02 --CLOSED--

Source: SDR ZW0A021195
OTHER · 2002-11-19 Unresolved
ATA 5320

Part: FLOOR SUPPORT — CORRODED (FUSELAGE) · airframe 44,189 hrs · 25,408 cycles

FLOOR TIE BETWEEN STRINGERS 28 AND 27 RT AND FROM STA 1003 TO 1079 IN AFT AUX FUEL TANK CAVITY HAS CORROSION. INSTALLED NEW TRACK FROM STA 1022 TO STA 1079. LAST CHECK C PERFORMED IN STL 01/07/02 --CLOSED--

Source: SDR ZW0A021192
OTHER · 2002-08-05 Unresolved
ATA 7250

Part: TURBINE — FAILED (LT ENGINE) · airframe 43,578 hrs · 24,993 cycles

DURING CLIMB LEFT ENG TURBINE FAILURE. FLT CREW DECLARED EMERGENCY SHUT ENG DOWN PER QRH RESULTING IN UNSCHEDULED LANDING. REPLACED NR 1 ENG, OPS AND LEAK CHECKED NR 1 ENG.

Source: SDR ZW0A0208204

2001

OTHER · 2001-02-07 Unresolved
ATA 3350

Part: BATTERY — INOPERATIVE (CABIN) · airframe 39,676 hrs · 22,770 cycles

DURING PREFLIGHT, FOUND EGRESS PATH MARKING SYSTEM LIGHTS INOP. REPLACED BATTERIES. OP 00-05 01-31-01 STL.

Source: SDR TWAA0107101
NO TEST · 2001-02-07 Unresolved
ATA 3350

Part: BATTERY — DISCHARGED (CABIN) · airframe 39,676 hrs · 22,770 cycles

DURING PREFLIGHT, FOUND EGRESS PATH MARKING SYSTEM LIGHTS INOP. REPLACED BATTERYS. OP 00-05 01-31-01 STL.

Source: SDR TWAA0102601
NO TEST · 2001-02-07 Unresolved
ATA 3350

Part: SOCKET — FAILED (ROW 33) · airframe 39,672 hrs · 22,767 cycles

THE EGRESS LIGHTS WERE INOPERATIVE AT ROW 33. SPLICED IN NEW LIGHT SOCKET. CHECK-C 1-20-01 STL.

Source: SDR TWAA0102504
NO TEST · 2001-01-08 Unresolved
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN) · airframe 39,471 hrs · 22,657 cycles

THE FWD OVERWING EMERGENCY EXIT SIGN LH AND RH HAND, THE FWD ENTRY PORTABLE EMERGENCY LIGHT, EGRESS LIGHTS ROW 5 THRU 7, AND EGRESS LIGHTS ROW 22 THRU 27 WERE INOPERATIVE. REPLACED BATTERY IN THE BATTERY PACK PN 41B030CF00101 FOR THE EXIT SIGN AND FOR THE ENTRY LIGHT, REPLACED A LIGHT MODULE PN 0105606-005 FOR FWD CABIN EGRESS LIGHTS, AND ADJUSTED BATTERY CONTACTS FOR THE AFT CABIN EGRESS LIGHTS. CHECK-C 11-16-99 MCI.

Source: SDR TWAA0100601

2000

WARNING INDICATION · 2000-05-24 Unresolved
ATA 3200

Part: LANDING GEAR — DAMAGED (LEFT) · airframe 37,564 hrs · 21,608 cycles

AFTER TAKEOFF GOT A RED LEFT MAIN LIGHT AND DOOR LIGHT ILLUMINATED. REPLACED LEFT MAIN GEAR ASSEMBLY. 0001 4-10-00 DFW.

Source: SDR TWAA0008401

1999

OTHER · 1999-12-21 Unresolved
ATA 5315

Part: FLOORBEAM — CORRODED (BS 1149 - 1169)

DURING CHECK-C MAINT, FOUND CORROSION ON FLOOR MEMBRANE BETWEEN STA 1149L AND 1169L, AT LONGERON 18L. ACCOMP NDT PER 51-00-01 PART 4.. REMOVED LIGHT AND MODERATE CORROSION ON LT FLOOR MEMBRANE BETWEEN STA 1149 AND 1169 AT LONGERON 18, PER SPM 6-80-01 PAGE 1 TO 3. REPAIRED AREA AT 1155-115 PER SRM 53-01, FIG 4 SHEET 3 PAGE 18 DOUBLER REPAIR. TREATED AREA FROM STA 1145L TO 1169L AT LONGERON 18 PER SRM 51-10-3(C)(1)AND (3), PAGE 45 AND 46.

Source: SDR TWAA0000806
OTHER · 1999-12-20 Unresolved
ATA 5320

Part: FLOOR PAN — CORRODED (BS 1107 - 1149)

DURING CHECK-C MAINT, FOUND CORROSION AT MEMBRANE FLOOR PAN ALONG LONGERON 18L, FROM STA 1107 THROUGH 1149. REMOVED LIGHT AND MODERATE CORROSION ON THE LT FLOOR MEMBRANE, LONGERON 18L FROM STA 1107 TO 1149 PER SPM 6-80-01, PAGE 1-3. REPAIRED AREA STA 1118 TO 1123 PER SRM 53- 01, FIG 4 SHEET 3 PAGE 18. TREATED AREA FROM STA 1107 TO 1149 LONGERON 18L FLOOR MEMBRANE PER SRM 51-10-3.

Source: SDR TWAA0000513
OTHER · 1999-12-17 Unresolved
ATA 5313

Part: LONGERON — CORRODED (BS 1031)

DURING CHECK-C MAINT, FOUND CORROSION AT STA 1031R, LONGERON 18. REMOVED CORROSION PER SRM 6-80-01. INSTALLED DOUBLER PER SRM 53-01, FIG 4.

Source: SDR TWAA0000512
OTHER · 1999-12-15 Unresolved
ATA 5320

Part: MEMBRANE — CORRODED (BS 439)

DURING CHECK-C MAINT, FOUND CORROSION AND PILLOWING AT STA 439, LONGERON 18L MEMBRANE. REMOVED CORRODED SECTIONS OF MEMBRANE PER SPM 6-80-01, PAGE 1. REPAIRED PER SRM 53-01, PAGE 18.

Source: SDR TWAA0000509
OTHER · 1999-12-15 Unresolved
ATA 5320

Part: MEMBRANE — CORRODED (BS 57)

DURING CHECK-C MAINT, FOUND CORROSION ON MEMBRANE AT STA 57R, LONGERON 18. CORROSION REMOVED PER SRM 53-01. INSTALLED DOUBLER PER 53-01.

Source: SDR TWAA0000511
OTHER · 1999-12-15 Unresolved
ATA 5313

Part: LONGERON — CORRODED (BS 1102)

DURING CHECK-C MAINT, FOUND CORROSION AT STA 1102R, LONGERON 18. CORRECTED PER SRM 53-01. TREATED AND PAINTED PER 51-10-B.

Source: SDR TWAA0000510
NO TEST · 1999-08-20 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (ROWS 19-22)

PDX - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE AT ROWS 19 THROUGH 22. REPLACED PACK BATTERIES AND LIGHTS OPERATED NORMALLY. (M)

Source: SDR ASAA9980177
NO TEST · 1999-06-19 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHT ABOVE THE AFT FLIGHT ATTENDANT SEAT FLICKERS ON AND OFF WITH ELECTRICAL POWER OFF. REPLACED THE BATTERIRES IN THE POWER SUPPLY AND OPERATED NORMALLY. (X)

Source: SDR ASAA9980139
NO TEST · 1999-06-05 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN)

PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9980133
NO TEST · 1999-05-23 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (ROW 23-27)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS FROM ROWS 23 TO 27 WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9980120
OTHER · 1999-04-24 Matched by certificate designator
ATA 5610

Part: PIN — LOOSE (RT COCKPIT)

SEA - DURING MAINTENANCE CHECK, THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED AND SECURED UPPER HINGE PIN ON WINDOW OPERATING MECHANISM AND OPERATED NORMALLY. (M)

Source: SDR ASAA9980087

1998

NO TEST · 1998-12-22 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (CABIN)

ONT - PRIOR TO DEPARTURE OF FLIGHT 555, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880272
NO TEST · 1998-12-21 Matched by certificate designator
ATA 3397

Part: WIRE — DISCONNECTED (CABIN)

SEA - PRIOR TO DEPARTURE OF FLIGHT 137, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHT IN THE FORWARD CABIN WERE INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880271
NO TEST · 1998-12-21 Matched by certificate designator
ATA 3350

Part: BATTERY — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE CATWALK AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880270
NO TEST · 1998-09-24 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880191
NO TEST · 1998-07-12 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE FORWARD ENTRY AND GALLEY AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880126
NO TEST · 1998-07-06 Matched by certificate designator
ATA 3350

Part: LIGHT — INOPERATIVE (CABIN)

SEA - PRIOR TO DEPARTURE OF FLIGHT 137, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880122
NO TEST · 1998-06-26 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

SFO - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY EVACUATION LIGHTS WOULD NOT EXTINGUISH WHEN CONTROL SWITCH PLACED TO OFF POSITION, WOULD EXTINGUISH WHEN SWITCH PLACED TO ARMED POSITION. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880113
OTHER · 1998-06-13 Matched by certificate designator
ATA 5610

Part: PIN — OUT OF ADJUST (RT COCKPIT)

SEA - DURING MAINTENANCE CHECK, THE FLIGHT COMPARTMENT RT SLIDING WINDOW WAS FOUND DIFFICULT TO OPEN. ADJUSTED THE WINDOW GUIDE PIN AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880105
OTHER · 1998-06-07 Matched by certificate designator
ATA 5610

Part: PANEL — MISALIGNED (COCKPIT)

ANC - AFTER ARRIVAL OF FLT 104, CREW REPORTED THE FLIGHT COMPARTMENT RT SLIDING WINDOW WOULD NOT OPEN COMPLETELY. REPOSITIONED THE WINDOW TRIM PANEL AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880104
OTHER · 1998-05-09 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE AFT CATWALK AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880081
NO TEST · 1998-04-09 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — DEFECTIVE (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY EVACUATION LIGHTS WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880069
NO TEST · 1998-03-25 Matched by certificate designator
ATA 3350

Part: FUSE — FAILED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. REPLACED THE FUSE IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880058
NO TEST · 1998-01-06 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DISCONNECTED (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHT COVER AT ROW 3 WAS FOUND PULLED UP AND THE 2ND FORWARD LIGHT WAS INOPERATIVE. RECONNECTED THE CONNECTOR TO THE LIGHT ASSEMBLY AND REINSTALLED THE TRACK COVER AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880005
NO TEST · 1998-01-02 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE CATWALK AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9880002

1997

NO TEST · 1997-12-26 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DISCONNECTED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. RECONNECTED CONNECTOR TO LIGHT ASSEMBLY AND OPERATED NORMALLY. (X)

Source: SDR ASAA9780298
NO TEST · 1997-12-18 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

PDX - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE AFT CABIN AND LOWER TAILCONE AREA ILLUMINATE AND REMAIN ILLUMINATED WITH MAIN BATTERY SWITCH OFF. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780289
NO TEST · 1997-11-21 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE MID CABIN WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780270
NO TEST · 1997-11-21 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780271
NO TEST · 1997-11-21 Matched by certificate designator
ATA 3350

Part: CONNECTOR — DISCONNECTED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. RECONNECTED CONNECTOR TO LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780269
NO TEST · 1997-11-09 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN)

SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780264
OTHER · 1997-10-23 Matched by certificate designator
ATA 5320

Part: JAMB — CORRODED (BS 180-200)

BFM - DURING 30K CHECK, CORROSION WAS FOUND ON R1 DOOR JAMB LOWER FORWARD CORNER. REPLACED LOWER SECTION OF R1 DOOR JAMB IAW DC9 SRM 53-05, FIG 55. TT: 29,023 HOURS. TC: 17,222. (X)

Source: SDR ASAA9780256
OTHER · 1997-10-23 Matched by certificate designator
ATA 5754

Part: SKIN — CREASED (RT LE FLAP)

BFM - DURNG 30K CHECK, CREASE WAS FOUND ON RT WING OUTBOARD FLAP INBOARD FIXED VANE. REPAIRED WITH BONDED DOUBLER IAW ASA EA 5750-01254. TT: 29,023 HOURS. TC: 17,222. (X)

Source: SDR ASAA9780255
OTHER · 1997-10-21 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (BS 927-946)

BFM - DURING 30K CHECK, CORROSION WAS FOUND ON CUSP MEMBRANE AT LONGERON 18L AND FS 930. REMOVED DAMAGED AREA AND INSTALLED DOUBLER IAW ASA EA 5310-01556. TT: 29,023 HOURS. TC: 17,222. (X)

Source: SDR ASAA9780252
OTHER · 1997-10-20 Matched by certificate designator
ATA 5753

Part: HINGE ARM — GALLED (LT TE FLAP)

BFM - DURING 30K CHECK, GALLED BUSHINGS WERE FOUND ON LT WING OUTBOARD FLAP INBOARD HINGE ARM LOWER MOUNT BOLT AND CORROSION ON INBOARD LUG. REPAIRED IAW ASA EA 5750-01256. (X)

Source: SDR ASAA9780250
OTHER · 1997-10-20 Matched by certificate designator
ATA 5753

Part: HINGE ARM — GROOVED (RT TE FLAP)

BFM - DURING 30K CHECK, GROOVED BUSHINGS WERE FOUND ON RT WING OUTBOARD FLAP INBOARD HINGE ARM PIVOT AND CORROSION IN BORE. REPAIRED IAW ASA EA 5750-01256. TT: 29,023 HOURS. TC: 17222. (X)

Source: SDR ASAA9780251
OTHER · 1997-10-10 Matched by certificate designator
ATA 5753

Part: SKIN — CRACKED (RT TE FLAP)

BFM - DURING 30K CHECK, PUNCTURE WAS FOUND IN RT WING INBOARD FLAP OUTBOARD VANE ON INBOARD LOWER SURFACE. REMOVED DAMAGED AREA AND INSTALLED DOUBLER IAW DC9 SRM 51-70-02. (M)

Source: SDR ASAA9780245
OTHER · 1997-10-10 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (BS 1032-1309)

BFM - DURING 30K CHECK, CORROSION WAS FOUND ON SEAT TRACK FROM FS 1032 TO 1309. REPLACED SEAT TRACK IAW DC9 SRM 51-30-00. (M)

Source: SDR ASAA9780246
OTHER · 1997-10-08 Matched by certificate designator
ATA 5320

Part: WEB — CRACKED (BS 1170-1276)

BFM - DURING 30K CHECK, CRACK WAS FOUND ON CUSP WEB AND ELONGATED HOLES FROM FS 1170 TO FS 1276. REMOVED DAMAGED AREA AND INSTALLED DOUBLER IAW DC9 SRM 53-05, PG 3, FIG 96. (M)

Source: SDR ASAA9780240
OTHER · 1997-10-06 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — GOUGED (BS 1338)

BFM - DURING 30K CHECK, GOUGE WAS FOUND ON AFT LAVATORY FLOORBEAM AT FS 1338. REMOVED AND REPLACED TOP ANGLE OF FLOORBEAM AT FS 1338 IAW DC9 SRM 51-10-04 AND 51-30-02. (M)

Source: SDR ASAA9780232
OTHER · 1997-10-06 Matched by certificate designator
ATA 5754

Part: SKIN — CRACKED (NR 2 LE SLAT)

BFM - DURING 30K CHECK, CRACKS AND BROKEN RIVETS WERE FOUND IN LEFT WING NR 2 L/E SLAT LOWER SKIN. SPLICED SKIN IAW DC9 SRM 57-09, FIG 10. (M)

Source: SDR ASAA9780239
OTHER · 1997-10-06 Matched by certificate designator
ATA 5320

Part: SILL — CRACKED (BS 46)

BFM - DURING 30K CHECK, CRACK WAS FOUND ON NLG WHEEL WELL DOOR SILL FRAME AT FS 46, LBL 18. REMOVED AND REPLACED FRAME IAW DC9 ARM 51-30-02 AND 51-30-05. (M)

Source: SDR ASAA9780237
OTHER · 1997-10-06 Matched by certificate designator
ATA 5320

Part: WEB — PUNCTURED (BS 206)

BFM - DURING 30K CHECK, PUNCTURE WAS FOUND ON MAIN CABIN FLOOR WEB AT FS 206, RBL 56. REPAIRED PUNCTURE IN WEB IAW DC9 SRM 53-01, FIG 4. (M)

Source: SDR ASAA9780230
OTHER · 1997-10-06 Matched by certificate designator
ATA 5311

Part: FRAME — CRACKED (BS 47)

BFM - DURING 30K CHECK, CRACKS AT FASTENER HOLES WERE FOUND ON NLG WHEEL WELL FRAME AT FS 47, LBL 30. REPAIRED FRAME IAW DC9 SRM 53-30, PAGE 85. (M)

Source: SDR ASAA9780235
OTHER · 1997-10-06 Matched by certificate designator
ATA 5320

Part: CHANNEL — CRACKED (BS 1338)

BFM - DURING 30K CHECK, CRACK WAS FOUND ON AFT CABIN ENTRY DOOR UPPER LEFT CHANNEL UNDER HINGE. REMOVED AND REPLACED CHANNEL IAW DC9 SRM 51-30-02. (M)

Source: SDR ASAA9780233
OTHER · 1997-10-06 Matched by certificate designator
ATA 5320

Part: WEB — CORRODED (BS 200-220)

BFM - DURING 30K CHECK, CORROSION WAS FOUND ON MAIN CABIN CUSP WEB AROUND NUT PLATE HOLES FROM FS 200 TO FS 220, RBL 22. REPAIRED WEB IW DC9 SRM 53-01, PAGE 3, FIG 4. (M)

Source: SDR ASAA9780231
OTHER · 1997-10-06 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (BS 200-579)

BFM - DURING 30K CHECK, CORROSION AND GOUGES WERE FOUND ON RT INBOARD SEAT TRACK FROM FS 200 TO FS 579, RBL 22. REMOVED AND REPLACED SEAT TRACK IAW DC9 SRM 51-30-01, 51-30-02, 51-30-05 AND 53-05. (M)

Source: SDR ASAA9780234
OTHER · 1997-10-06 Matched by certificate designator
ATA 5753

Part: SKIN — CRACKED (LT TE FLAP)

BFM - DURING 30K CHECK, CRACK WAS FOUND LEFT OUTBOARD FLAP TE 14 INCHES OUTBOARD OF CENTER FLEX JOINT. REMOVED DAMAGED MATERIAL AND REPAIRED WITH FIBERGLASS DOUBLER IAW DC9 SRM 57-03, FIG 8. (M)

Source: SDR ASAA9780238
OTHER · 1997-10-06 Matched by certificate designator
ATA 5320

Part: SILL — CRACKED (BS 46-83)

BFM - DURING 30K CHECK, CRACK WAS FOUND ON NLG WHEEL WELL DOOR SILL FRAME AT FS 46, RBL 18. REMOVED AND REPLACED FRAME IAW DC9 SRM 51-30-02 AND 51-30-05. (M)

Source: SDR ASAA9780236
OTHER · 1997-09-29 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (BS 1145-1271)

BFM - DURING 30K CHECK, CORROSION WAS FOUND ON SEAT TRACK NR 2 FROM FS 1145 TO 1271. REPLACED SEAT TRACK IAW DC9 SRM 51-30-01 AND 53-05, FIG 4. (M)

Source: SDR ASAA9780224
OTHER · 1997-09-26 Matched by certificate designator
ATA 5753

Part: SKIN — DAMAGED (RT TE FLAP VANE)

BFM - DURING 30K CHECK, THE RT WING OUTBOARD FLAP VANE LEADING EDGE SKIN WAS FOUND DAMAGED AT 4 LOCATIONS. REPAIRED IAW ASA EA 5750-01254. (M)

Source: SDR ASAA9780218
OTHER · 1997-09-26 Matched by certificate designator
ATA 5330

Part: SKIN — GOUGED (BS 788)

BFM - DURING 30K CHECK, THE FUSELAGE SKIN WAS FOUND GOUGED ON OUTER SURFACE AT FS 788 BETWEEN LONGERON 17R AND 18R. REPAIRED IAW DC9 SRM 53-04, PG 22, FIG 38. (M)

Source: SDR ASAA9780217
NO TEST · 1997-08-31 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — INOPERATIVE (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780191
NO TEST · 1997-07-30 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN)

PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9780165
OTHER · 1997-07-04 Matched by certificate designator
ATA 5730

Part: SKIN — CRACKED (RT WING)

SEA - RIGHT WING LOWER SURFACE SKIN CRACKED AT FORWARD OUTBOARD RADIUS OF FUEL PANEL DOOR CUTOUT. REPAIRED PER ASA EA 5730-01052. (M)

Source: SDR ASAA9780134

1996

NO TEST · 1996-12-19 Matched by certificate designator
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 1 TO 6 WERE FOUND INOPERATIVE. REPLACED BATTERY PACK AND OPERATED NORMALLY. (M)

Source: SDR ASAA9680276
OTHER · 1996-12-09 Matched by certificate designator
ATA 2565

Part: INFLATION BOTTLE — LOW PRESSURE (L2 DOOR)

OAK - DURING C-CHECK, THE L2 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE EMERGENCY EVACUATION SLIDE. (M)

Source: SDR ASAA9680268
NO TEST · 1996-12-08 Matched by certificate designator
ATA 2565

Part: SLIDE — FAILED (TAIL CONE)

OAK - DURING C-CHECK, THE TAILCONE EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE TAILCONE EMERGENCY EVACUATION SLIDE. (M)

Source: SDR ASAA9680265
OTHER · 1996-11-12 Matched by certificate designator
ATA 2565

Part: SLIDE — OUT OF POSITION (L2 DOOR)

LAX - AFTER ARRIVAL OF FLT 255 - CREW REPORTED THE L2 DOOR DIFFICULT TO OPEN, APPEARS TO BE STICKING AT LOWER AFT CORNER. FOUND THE EMERGENCY EVACUATION SLIDE COVER HOLDING THE DOOR TRIM OUT OF POSITION AND INTERFERRING WITH DOOR FRAME. REPLACED THE EMERGENCY EVACUATION SLIDE ASSEMBLY AND DOOR OPERATED NORMALLY. (M)

Source: SDR ASAA9680254
NO TEST · 1996-09-21 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTNENANCE CHECK, THE 0VERHEAD EMERGENCY LIGHTS IN THE TAILCONE AREA WERE FOUND INOPERATIVE. REPLACED THE BATTERIES AND OPERATED NORMALLY. (M)

Source: SDR ASAA9680206
NO TEST · 1996-09-21 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROW 29 AFT WERE FOUND INOPERATIVE. REPLACED THE BATTERIES AND OPERATED NORMALLY. (M)

Source: SDR ASAA9680205
NO TEST · 1996-08-14 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 1 TO 6 WERE FOUND DIM. REPLACED THE BATTERIES AND OPERATED NORMALLY. (M)

Source: SDR ASAA9680197
NO TEST · 1996-08-11 Matched by certificate designator
ATA 3350

Part: BATTERIES — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE AFT CABIN WERE FOUND INOPERATIVE. REPLACED THE BATTERIES AND OPERATED NORMALLY. (M)

Source: SDR ASAA9680173
NO TEST · 1996-07-25 Matched by certificate designator
ATA 3350

Part: POWER SUPPLY — DEFECTIVE (TAILCONE)

LAX - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE TAILCONE AREA WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

Source: SDR ASAA9680157
OTHER · 1996-07-07 Matched by certificate designator
ATA 2565

Part: SLIDE BOTTLE — LOWPRESSURE (TAILCONE)

SEA - DURING MAINTENACNE CHECK, THE TAILCONE EMERGENCY EVACUATIONSLIDE INFLATION BOTTLE PRESSURE WAS FOUND LOW. REPLACED THE TAILCONEEMERGENCY EVACUATION SLIDE. (M)

Source: SDR ASAA9680147

1995

NO TEST · 1995-08-21 Matched by certificate designator
ATA 2565

Part: EVAC SLIDE — FAILED TEST (R1 DOOR)

OAK - DURING C-CHECK, THE R1 DOOR EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE R1 DOOR EMERGENCY EVACUATION SLIDE. (M)

Source: SDR ASAA9580188
NO TEST · 1995-02-22 Matched by certificate designator
ATA 3350

Part: EEL BATT PACK — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 14 TO 20 WERE FOUND INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9580016
NO TEST · 1995-02-21 Matched by certificate designator
ATA 3350

Part: EEL BATT PACK — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9580012
NO TEST · 1995-02-21 Matched by certificate designator
ATA 3350

Part: EEL BATT PACK — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 14 TO 20 REMAINED ILLUMINATED WITH THE SWITCH IN THE OFF POSITION. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9580013
NO TEST · 1995-02-17 Matched by certificate designator
ATA 3350

Part: EEL BATT PACK — DISCHARGED (CABIN)

SEA - DURING MAINTENANCE CHECK, THE FWD OVERWING EMERGENCY EXIT SIGNS WERE FOUND INOPERATIVE. REPAIRED WIRING, REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9580001
NO TEST · 1995-02-13 Matched by certificate designator
ATA 3350

Part: EEL BATTERY — LOOSE (CABIN)

ONT - FLT 531 - PRIOR TO DEPARTURE, CREW REPORTED ROW 13 EMERGENCY EXIT FLOOR TRACK LIGHTS WILL NOT TEST. RESEATED BATTERY IN PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9565
NO TEST · 1995-02-08 Matched by certificate designator
ATA 3350

Part: EEL BATT PACK — DISCHARGED (CABIN)

PDX - DURING MAINTENANCE CHECK, THE FWD RT OVERWING EMERGENCY EXIT LIGHT WAS INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHT OPERATED NORMALLY. (W)

Source: SDR ASAA9556
NO TEST · 1995-02-08 Matched by certificate designator
ATA 3350

Part: EEL BATTERY PACK — DISCHARGED (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM 16 TO 20 WERE FOUND INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9558
NO TEST · 1995-02-08 Matched by certificate designator
ATA 3350

Part: EEL BATT PACK — DISCHARGED (CABIN)

PDX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROW 1 TO 3 WERE FOUND INOPERATIVE. REPLACED THE BATTERY PACK AND LIGHTS OPERATED NORMALLY. (W)

Source: SDR ASAA9557
NO TEST · 1995-01-21 Matched by certificate designator
ATA 3350

Part: EEL BATTERY — DISCHARGED (CABIN)

SEA - CHECK, 3 CEILING LIGHTS INOP AT ROWS 24 AND 25. MAINTENANCE REPLACED BATTERIES AND SYSTEM OPS CHECKED NORMAL. (W)

Source: SDR ASAA9528