N949PH

SIKORSKY S-92A · 2014 · Rotorcraft · 1 engine · 19 seats · Valid Registration

Registered owner: WELLS FARGO EQUIPMENT FINANCE INC, LA (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
PHI Aviation, LLC (HEEA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

4 reports on file, 2015-10-09 – 2025-01-27.

ENGINE STOPPAGE · 2025-01-27 Matched by certificate designator
ATA 7200

Part: PLATE — CRACKED (#1 ENGINE) · airframe 9,671 hrs

DURING DEPARTURE FROM MC782/DEEPWATER POSEIDON THE AIRCRAFT EXPERIENCED AN UN-COMMANDED, INFLIGHT SHUTDOWN OF THE #1 ENGINE. THE AIRCREW FOLLOWED THE CHECKLIST EMERGENCY PROCEDURE AND LANDED AT HOUMA WITHOUT FURTHER INCIDENT.

Source: SDR HEEA202501310001
FALSE WARNING · 2024-06-13 Matched by certificate designator
ATA 2697

Part: WIRE HARNESS — INOPERATIVE (NR 2 FIRE DETECT) · airframe 9,023 hrs

#2 ENGINE FIRE LIGHT ILLUMINATED WITH NO SECONDARY INDICATIONS. PERFORMED EMERGENCY PROCEDURES AND RETURNED TO BASE.

Source: SDR HEEA202406140001
WARNING INDICATION · 2024-02-14 Matched by certificate designator
ATA 2421

Part: GENERATOR — INOPERATIVE (NR 2 AC) · airframe 8,638 hrs

ON SHORT FINAL TO MV C-CONSTRUCTOR #2 GEN FAIL CAUTION LIGHT ILLUMINATED. CONDUCTED A WAVE-OFF INTO A HOLDING PATTERN. EXECUTED CHECKLIST TOR #2 GEN FAIL TO RECYCLE/RESET THE GENERATOR. GENERATOR RETURNED WITHOUT ISSUE. CONTINUED FLIGHT IAW PROCEDURES.

Source: SDR HEEA202402160001
WARNING INDICATION · 2015-10-09 Matched by certificate designator
ATA 2910

Part: HEAT EXCHANGER — READS HIGH · airframe 210 hrs

AFTER 15 MINUTES OF FLIGHT, NOTED THAT NR 1 HYDRAULIC PRESSURE WAS INDICATING OVER LIMIT HIGH. AFTER 1 OR 2 MINUTES THE NR 1 HYDRAULIC SYS FAILED. FOUND RT HEAT EXCHANGER, WELD IN FRAME OF EXCHANGER CRACKED AND LOSS OF FLUID.

Source: SDR HEER20151009770