N962JT

AIRBUS A321-231 · 2016 · Fixed-wing multi-engine · 2 engines · 379 seats · Valid Registration

Registered owner: JETBLUE AIRWAYS CORP, NY (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

No operator established for this aircraft.

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

13 reports on file, 2017-03-25 – 2024-11-22.

FLUID LOSS; SMOKE/FUMES/ODORS/SPARKS · 2024-11-22 Matched by certificate designator
ATA 4990

Part: OIL SYSTEM — LEAKING (APU) · airframe 34,699 hrs · 6,827 cycles

FLT#1515, JFK-SFO. (AIRCRAFT PERFORMED AN AIR TURN BACK TO JFK) ' ODOR EVENT- COCKPIT AND ACTIVE CABIN TRIED TO ISOLATE W/FCOM GUIDANCE BOTH PACKS PRODUCING ODOR ALL PHASES OF FLIGHT; C/W INFO NOTICE 2017-T015K. IDENTIFIED APU OIL LEAKS. ENGINE RAN FOR DECONTAMINATION. NO ACTIVE ODOR NOTED. DECONTAMINATION LEVEL C WAS ACCOMPLISHED PER TSM 05-50-00-810-831-A. AIRCRAFT IS OK FOR SERVICE.'

Source: SDR YENA2024112501500
Earlier reports · 2017–2022 · 12 reports

2022

OTHER · 2022-07-27 Matched by certificate designator
ATA 3350

Part: EPSU — FAILED (11WL-BATT) · airframe 24,666 hrs · 4,833 cycles

FLT#2923, JFK-LAX. 'L3 EMERGENCY EXIT SIGN DID NOT ILLUMINATE ON TEST AS WELL AS CEILING LIGHTS ROW 9/10 AND ROW 19; REMOVED AND REPLACED EPSU 11WL BATTERY PER AMM 33-51-38. NO HELP SEE LOG PAGE 3389919, ITEM 2 (REMOVED AND REPLACED EPSU 11WL UNIT PER AMM 33-51-38. OPS CHECK NORMAL) FOR RESOLUTION.'

Source: SDR YENA2022072900723
OTHER · 2022-07-27 Matched by certificate designator
ATA 3350

Part: EPSU — FAILED (11WL) · airframe 24,666 hrs · 4,833 cycles

FLT#2923, JFK-LAX. 'L3 EMERGENCY EXIT SIGN DID NOT ILLUMINATE ON TEST AS WELL AS CEILING LIGHTS ROW 9/10 AND ROW 19; REMOVED AND REPLACED EPSU 11WL BATTERY PER AMM 33-51-38. NO HELP SEE LOG PAGE 3389919, ITEM 2 (REMOVED AND REPLACED EPSU 11WL UNIT PER AMM 33-51-38. OPS CHECK NORMAL) FOR RESOLUTION.'

Source: SDR YENA2022072900724
SMOKE/FUMES/ODORS/SPARKS · 2022-03-23 Matched by certificate designator
ATA 2100

Part: EXTRACTOR — FAILED · airframe 23,231 hrs · 4,550 cycles

FLT#1415, JFK-SFO. (AIRCRAFT DECLARED AN EMERGENCY AND PERFORMED AN AIR TURN BACK JFK-JFK). ' CABIN FUME EVENT OCCURRENCE; ODOR ISOLATED TO BLEED #2. TWO DETERGENT WASHED WERE PERFORMED ON #2 ENG. REF WO # 1169809. AFTER DETERGENT WASH NO OIL WETNESS IS PRESENT IN LPC REF LP 3197275 (LP 3197275: BORESCOPE INSP ACCOMPLISHED OF LPC 2.0, 2.5, 2.3 & HPC STG 3 &4 FOR OIL WETNESS/ CONTAMINATION. NONE NOTED. ENG OK FOR SERVICE.) & AMM 71-00-00-801-A. REF LP 3197277-1 (LP 3197277-1: ITEM PLACED ON MEL 49-10-01A, CAT C (M) ACTION ACCOMPLISHED, MCC BOB NOTIFIED, MX-4 UPDATED PLACARD INSTALLED.) FOR APU OIL FINDING IN LOAD COMPRESSOR CAVITY DRAIN REF LP 3197278 FOR ECS COMPLETION. REF LP 3197274-2 (LP 3197274-2: REINSTALLED ACCESS PANEL 192KB IAW AMM 53-35-13) TO FOR ODOR CHECK IN HIGH POWER RUN WITH NO FINDINGS AFTER LEVEL C ECS. APU WAS PLACED ON MEL AND ECS LEVEL C PERFORMED. OZONE FILTER FOR PACK 2 REPLACED REF LP 3197272-1 (LP 3197272-1: POST-ECS CHECK COMPLETED PER AMM 21-00-00-615-804-A) AND LP 3197273 FOR WATER INJECTOR & WATER EXTRACTOR REPLACEMENT (LP 3197273: REMOVED AND REPLACED WATER EXTRACTOR # 2 IAW AMM 21-52-16. OPS CHECK GOOD. NIL LEAK FOUND.).'

Source: SDR YENA2022032900318
SMOKE/FUMES/ODORS/SPARKS · 2022-03-23 Matched by certificate designator
ATA 2100

Part: INJECTOR — FAILED · airframe 23,231 hrs · 4,550 cycles

FLT#1415, JFK-SFO. (AIRCRAFT DECLARED AN EMERGENCY AND PERFORMED AN AIR TURN BACK JFK-JFK). ' CABIN FUME EVENT OCCURRENCE; ODOR ISOLATED TO BLEED #2. TWO DETERGENT WASHED WERE PERFORMED ON #2 ENG. REF WO # 1169809. AFTER DETERGENT WASH NO OIL WETNESS IS PRESENT IN LPC REF LP 3197275 (LP 3197275: BORESCOPE INSP ACCOMPLISHED OF LPC 2.0, 2.5, 2.3 & HPC STG 3 &4 FOR OIL WETNESS/ CONTAMINATION. NONE NOTED. ENG OK FOR SERVICE.) & AMM 71-00-00-801-A. REF LP 3197277-1 (LP 3197277-1: ITEM PLACED ON MEL 49-10-01A, CAT C (M) ACTION ACCOMPLISHED, MCC BOB NOTIFIED, MX-4 UPDATED PLACARD INSTALLED.) FOR APU OIL FINDING IN LOAD COMPRESSOR CAVITY DRAIN REF LP 3197278 FOR ECS COMPLETION. REF LP 3197274-2 (LP 3197274-2: REINSTALLED ACCESS PANEL 192KB IAW AMM 53-35-13) TO FOR ODOR CHECK IN HIGH POWER RUN WITH NO FINDINGS AFTER LEVEL C ECS. APU WAS PLACED ON MEL AND ECS LEVEL C PERFORMED. OZONE FILTER FOR PACK 2 REPLACED REF LP 3197272-1 (LP 3197272-1: POST-ECS CHECK COMPLETED PER AMM 21-00-00-615-804-A) AND LP 3197273 FOR WATER INJECTOR & WATER EXTRACTOR REPLACEMENT (LP 3197273: PER AMM 21-00-00-615-804-A REMOVED AND REPLACED PACK # 3 WATER INJECTOR PER AMM 21-52-42 OPS CHECK GOOD).'

Source: SDR YENA2022032900319

2021

SMOKE/FUMES/ODORS/SPARKS · 2021-08-25 Matched by certificate designator
ATA 2530

Part: COFFEEMAKER — FAILED (FWD GALLEY) · airframe 21,047 hrs · 4,114 cycles

FLT 2577, BOS-LAS. FWD COFFEE MAKER INOP. LOUD POP ELECT SMELL C/B 105 POPPED ( COFFEE MAKERS ); R & R COFFEE MAKER PER AMM 25-35-00. OPS CHECK GOOD. THIS CLEARS MDDR 447726. MX4 UPDATED. PLACARD REMOVED. MCC NOTIFIED.

Source: SDR YENA2021083100552

2020

OTHER · 2020-10-22 Matched by certificate designator
ATA 2565

Part: SLIDE — UNWANTED DEPLOY (L1 DOOR) · airframe 18,299 hrs · 3,562 cycles

DURING HEAVY MAINTENANCE, L1 INADVERTANT DOOR SLIDE DEPLOYMENT. REMOVED AND REPLACED L1 DOOR SLIDE, IAW A320/A321 AMM 25-62-44-000-012-A AND AMM 25-62-44-400-007-A. A/C OK FOR SERVICE.

Source: SDR YENA2020102600500

2019

OTHER · 2019-02-18 Matched by certificate designator
ATA 3350

Part: EPSU — FAILED (CABIN) · airframe 12,884 hrs · 2,508 cycles

DURING HEAVY MAINTENANCE, EPSU BATTERY 13WL FAILED TEST, REF LHT NR 5000852972-0010. REMOVED EPSU WITH LOW VOLTAGE IAW AMM 33-51-38-000-001-A REV 76. INSTALLED NEW EPSU IAW AMM 33-51-38-400-001-A REV 76. OPS TEST OK IAW AMM 33-51-38-740-050-B REV 76.

Source: SDR YENA201902180085
OTHER · 2019-02-18 Matched by certificate designator
ATA 3350

Part: EPSU — FAILED (CABIN) · airframe 12,884 hrs · 2,508 cycles

DURING HEAVY MAINTENANCE, EPSU BATTERY 14WL FAILED TEST, REF LHT NR 5000852972-0010. REMOVED EPSU WITH LOW VOLTAGE IAW AMM 33-51-38-000-001-A REV 76. INSTALLED NEW EPSU IAW AMM 33-51-38-400-001-A REV 76 OPS TEST OK IAW AMM 33-51-38-740-050-B REV 76.

Source: SDR YENA201902180086
OTHER · 2019-02-18 Matched by certificate designator
ATA 3350

Part: EPSU — FAILED (CABIN) · airframe 12,884 hrs · 2,508 cycles

DURING HEAVY MAINTENANCE, EPSU BATTERY 15WL FAILED TEST, REF LHT NR 5000852972-0010. REMOVED EPSU WITH LOW VOLTAGE IAW AMM 33-51-38-000-001-A REV 76. INSTALLED NEW EPSU IAW AMM 33-51-38-400-001-A REV 76 OPS TEST OK IAW AMM 33-51-38-740-050-B REV 76.

Source: SDR YENA201902180087
NO TEST · 2019-02-18 Matched by certificate designator
ATA 3350

Part: BATTERY — NO TEST (12WL) · airframe 12,884 hrs · 2,508 cycles

DURING HEAVY MAINTENANCE, EPSU BATTERY 12WL FAILED TEST; REF LHT NR 5000852972-0010 REMOVED EPSU WITH LOW VOLTAGE IAW AMM 33-51-38-000-001-A REV 76. INSTALLED NEW EPSU IAW AMM 33-51-38-400-001-A REV 76 OPS TEST OK IAW AMM 33-51-38-740-050-B REV 76

Source: SDR YENA201902228084

2017

FALSE WARNING · 2017-10-27 Matched by certificate designator
ATA 2611

Part: SMOKE DETECTOR — FAILED (CARGO BAY) · airframe 6,896 hrs · 1,342 cycles

FLT 2024, LAX-JFK. INTERMITTENT "FWD CARGO SMOKE" ECAM BELOW 16000. "SMOKE" MX STATUS MSG; FOUND FAULT 26-16-15 SMOKE DET FWD LDCC (3WH) DURING CFDS CARGO SMOKE TEST. R&R FWD CARGO SMOKE DETECTOR 3WH REF AMM 26-16-15. OPS CHK GOOD. NO FAULTS NOTED. UPON ARRIVAL INSPECTED ALL REMOVED BAGS & FWD CARGO COMPT FOR OBVIOUS BURNS OR SMOKE ODORS. NONE PRESENT. AIRCRAFT OK FOR CONTINUED SVC.

Source: SDR YENA201710270879
WARNING INDICATION; FLT CONT AFFECTED · 2017-03-25 Matched by certificate designator
ATA 2780

Part: SLAT SYSTEM — MALFUNCTIONED · airframe 4,237 hrs · 825 cycles

EMERGENCY DECLARED, SLATS FAULT ON APPROACH, ALL ECAM / QRH PROCEDURES COMPLETED. LANDED FLAPS AT 3 / SLATS AT 0. PERFORMED TSM 28-81-00-810-810-A. INSPECTION FOUND 6091CM TRIPPED, TORQUE LIMITER. PERFORMED THE RESET OF TORQUE LIMITER IAW AMM 27-80-00-866-006 AND OPS CHECK OF OF SLAT / FLAP SYSTEM IAW AMM 27-84-00-710-001-A. NO FAULTS OR TRIPPED LIMITERS ARE FOUND. PERFORMED GVI IAW AMM 27-84-00-210-001-A. ALL OPS NORMAL.

Source: SDR YENA201703250212