N974AS
Registered owner: DIAMOND AIRCRAFT SALES U S A INC (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
122 reports on file, 1995-06-03 – 2005-05-23.
Part: INTERCOSTAL — CORRODED (FS 1212-1231)
OKC - DURING CHECK, INTERCOSTAL CORRODED ON LOWER HORIZONTAL AND VERTICAL FLANGES. REPLACED INTERCOSTAL. (M)
Part: FRAME — CORRODED (FS 1060)
OKC - FOUND DURING C-CHECK, FRAME CORRODED AROUND FASTENERS. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (M)
Part: INTERCOSTAL — CORRODED (FS 1153)
OKC - DURING C-CHECK, FOUND INTERCOSTAL CORRODED. REPLACED INTERCOSTAL. (M)
Part: FRAME — CORRODED (FS 1079)
OKC - DURING C-CHECK, FOUND FRAME CORRODED AROUND FASTENERS. REMOVED DAMAGED SECTIONS. INSTALLED REPAIR DOUBLER AND FILLER. (M)
Part: SHEAR TIE — CORRODED (FUSELAGE)
OKC - DURING C-CHECK, FOUND SHEAR TIE CORRODED AT STATION 1219 BETWEEN LONGERON 29 AND 30R. REMOVED AND REPLACED DAMAGED SHEAR TIE. (M)
Part: FLOORBOARD — DAMAGED (FUSELAGE)
OKC - DURING C-CHECK, FOUND CABIN FLOORBOARD STATION 886 TO 946 RBL 22 TO LBL 22 HAS FIBER DAMAGE ON UPPER FACE AD TORN OUT INSERTS. REMOVED AND REPLACED FLOORBOARD. (M)
Part: SKIN — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, MID CARGO COMPARTMENT STATION 731 LONGERON 30 SKIN AROUND DRAIN COVER IS CORRODED. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER. (M)
Part: CHANNEL — CRACKED (FLOORBOARD)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD STATION 1155 TO 1250 LBL 44 TO 54 HAT CHANNEL IS CRACKED. COMPLETED A FIBERGLASS REPAIR. (M)
Part: INTERCOSTAL — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, LONGERON 28R INTERCOSTAL IS CORRODED BETWEEN STATION 1003 AND 1022. REMOVED AND REPLACED INTERCOSTAL. (M)
Part: SEAT TRACK — CORRODED (FUSELAGE)
OKC - DURING C-CHECK, FOUND CABIN SEAT TRACK LBL 44 STATION 1174 IS EXFOLIATED. REMOVED AND REPLACED SEAT TRACK. (M)
Part: LONGERON — CORRODED (FUSLEAGE)
OKC - FOUND DURING C-CHECK, LONGERON 29L IS CORRODED ON THE LOWER SURFACE OF THE INBOARD FLANGE AT STATION 1206. REMOVED AND REPLACED DAMAGED LONGERON AND INSTALLED SPLICE. (M)
Part: LONGERON — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, LONGERON 30 IS CORRODED ON THE TOWER SURFACE OF THE INBOARD FLANGE AT STATION 1198 TO 1203. REMOVED DAMAGED PERFORMED HFEC INSPECTION, AND INSTALLED REPAIR STRAPS LONGERON. (M)
Part: FRAME — CORRODED (FS 1155)
OKC - DURING C-CHECK, FOUND FRAME AT STATION 1155 CORRODED. REMOVED AND REPLACED DAMAGED FRAME. (M)
Part: BEAR STRAP — CORRODED (FS 1210)
OKC - DURING C-CHECK, AFT CARGO COMPARTMENT DOOR CUTOUT BEAR STRAP IS CORRODED AT STATION 1210. REMOVED DAMAGE AND INSTALLED REPAIR INTERNAL FILLER, EXTERNAL DOUBLERS. AFT CARGO DOOR P/N 5936667-51, BEAR STRAP P/N 59364335. (M)
Part: LONGERON — CORRODED (FS 1203-1243)
OKC - DURING C-CHECK, FOUND LONGERON 30 IS CORRODED AT STATION 1220. REMOVED AND REPLACED STRAP. (M)
Part: SEAT TRACK — CORRODED (FS 218-237)
OKC - DURING C-CHECK, FOUND CABIN SEAT TRACK BL 44 STATION 218-237 IS CORRODED. REMOVED AND REPLACED DAMAGED SECTION OF TRACK. (M)
Part: SPLICE — CORRODED (FS 1155)
OKC - DURING C-CHECK, FOUND STATION 1155 FRAME SPLICE STRAP IS CORRODED. REMOVED AND REPLACED STRAP. (M)
Part: SKIN — GOUGED (FLAP)
OKC - DURING C-CHECK, RIGHT WING INBOARD FLAP GOUGED OUTBOARD OF BUTT JOINT BOTTOM SURFACE. REMOVED DAMAGE, AND INSTALLED DOUBLER IN FLAP SKIN. (M)
Part: LONGERON — CORRODED (FS 1237-1297)
OKC - DURING C-CHECK, FOUND LONGERON 30 IS CORRODED ON FLANGES AT STATION 1237-1241. REMOVED AND REPLACED DAMAGED LONGERON. (M)
Part: STRUCTURE — CORRODED (CARGO BAY)
OKC - DURING C-CHECK, AFT CARGO COMPARTMENT LONGERON IS CORRODED ON BETWEEN 27R AND 27L. REMOVED AND REPLACED DAMAGED FRAME SEGMENT AND REPAIR ANGLES. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)
Part: CUSP WEB — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CUSP WEB CORRODED AT STATION 399. REMOVED CORROSION AND INSTALLED SEGMENT AND DOUBLER. (M)
Part: FLOOR PANEL — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FLOORBOARD HAS THREE CORRODED INSERTS. REPLACED FLOOR PANEL. (M)
Part: FLOORBOARD — TORN (FUSELAGE)
OKC - FOUND DURING C-CHECK, FLOORBOARD HAD TORN OUT INSERTS. REPLACED FLOOR PANEL. (M)
Part: FLOOR PANEL — PUNCTURED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS PUNCTURED. REPLACED FLOOR PANEL. (M)
Part: FLOORBOARD — PUNCTURED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAS TWO PUNCTURES AND IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)
Part: CUSP WEB — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CUSP WEB CORRODED AT STATION 1158 TO 1166. REMOVED CORROSION AND INSTALLED SEGMENT AND DOUBLER. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)
Part: SKIN — DENTED (FUSLEAGE)
OKC - DURING C-CHECK, FOUND FUSELAGE SKIN HAD DENT AT STATION 1220 LEFT 6 INCHES ABOVE CUSP LINE. COLD WORKED DENT AND INSTALLED SKIN AND DOUBLER. (M)
Part: FLOOR PANEL — DAMAGED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FORWARD ENTRY FLOOR PANEL CORE DAMAGED. REPLACED FLOOR PANEL. (M)
Part: FRAME — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FRAME CORRODED AT STATION 1212. REMOVED DAMAGE AND INSTALLED A REPAIR ANGLE. (M)
Part: FLOORBOARD — DELAMINATED (FUSELAGE)
OKC - DURING C-CHECK, FOUND OVERWING FLOORBOARD AT STATION 827 IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)
Part: CHANNEL — CRACKED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAT CHANNEL IS CRACKED. REMOVED AND REPLACED DAMAGED HAT CHANNEL. (M)
Part: DOOR FRAME — CRACKED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FORWARD ENTRY DOOR LEFT DOOR FRAME LOWER FINGER CRACKED. REMOVED DAMAGE INSTALLED FILLER AND DOUBLER. (M)
Part: CUSP WEB — CORRODED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CUSP WEB CORRODED AT STATION 416 TO 419. REMOVED CORROSION AND INSTALLED DOUBLER. (M)
Part: FLOORBOARD — DAMAGED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAS UPPER FACE FIBER DAMAGE. REPLACED FLOOR PANEL. (M)
Part: FLOORBOARD — DELAMINATED (FUSELAGE)
OKC - DURING C-CHECK, FOUND RIGHT OVERWING FLOORBOARD AT STATION 807 IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)
Part: CHANNEL — GOUGED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAT CHANNEL IS GOUGED. REMOVED AND REPLACED DAMAGED HAT CHANNEL. (M)
Part: FLOORBOARD — DELAMINATED (FUSELAGE)
OKC - DURING C-CHECK, FOUND CABIN FLOORBOARD DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)
Part: SKIN — DENTED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FUSELAGE HAS TWO DENTS AT STATION 233 LONGERON 17 AND 18L. REMOVED DAMAGE, INSTALLED SKIN AND DOUBLER. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOOR PANEL EDGES SEPARATING, DELAMINATING. REPLACED FLOOR PANEL. (M)
Part: FLOORBOARD — DELAMINATED (FUSELAGE)
OKC - DURING C-CHECK, FOUND FLOORBOARD STATION 160 IS DELAMINATED. REMOVED AND REPLACED FLOORBOARD. (M)
Part: FLOOR PANEL — CRACKED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS CRACKED. REPLACED FLOOR PANEL. (M)
Part: CHANNEL — CRACKED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD HAT CHANNEL IS CRACKED. REPLACED HAT CHANNEL. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOOR PANEL DELAMINATING. REPLACED FLOOR PANEL. (M)
Part: FLOOR PANEL — DAMAGED (FUSELAGE)
OKC - FOUND DURING C-CHECK, FLOORBOARD HAS INSERTS PULLED OUT. REPLACED FLOOR PANEL. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - FOUND DURING C-CHECK, CABIN FLOORBOARD IS DELAMINATED. REPLACED FLOOR PANEL. (M)
Part: SKIN — LIGHTNING STRIKE (FUSELAGE)
OKC - DURING C-CHECK, FOUND FUSELAGE SKIN HAS LIGHTNING STRIKE AT STATION 275 BETWEEN L1 AND L2. REMOVED DAMAGE INSTALLED SKIN AND DOUBLER. (M)
Part: FLOOR SUPPORT — CORRODED (FS 160-200)
OKC - FOUND C-CHECK, PAX CABIN FLOOR TRACK CORRODED. REPLACED DAMAGED TRACK. (M)
Part: FLOOR SUPPORT — CORRODED (FS 160-200)
OKC - DUIRNG C-CHECK, PASSENGER CABIN FLOOR TRACK CORRODED. REPLACED DAMAGED TRACK. (M)
Earlier reports · 1995–2004 · 71 reports
2004
Part: LIGHT — INOPERATIVE (CABIN) · airframe 36,095 hrs · 18,941 cycles
LINE CHECK- PORTABLE EMERGENCY LIGHT, SITUATED NEAR THE FORWARD PASSENGER DOOR, IS OPERATIVE. REPLACED LIGHT ASSEMBLY.
Part: LIGHT — INOPERATIVE (FWD ENTRY WAY)
PORTABLE EMERGENCY LIGHT, SITUATED NEAR THE FORWARD PASSENGER DOOR, IS INOPERATIVE. REPLACED LIGHT ASSEMBLY.
Part: BATTERY PACK — INOPERATIVE (EMERGENCY LIGHT)
LAX - DURING PREFLIGHT CHECK, FOUND COCKPIT EMERGENCY OVERHEAD FLOOR LIGHTS INOPERATIVE UPON TEST. REPLACED POWER SUPPLY, BATTERY PACK. LIGHTS THEN OPERATED PROPERLY. (M)
Part: WINDOW — STUCK (COCKPIT)
SEA - RIGHT SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. TIGHTENED NUT ON UPPER GUIDE RAIL. WINDOW THEN OPERATED PROPERLY. (M)
Part: ELEMENT — DELAMINATED (VOR ANTENNA)
OKC -DURING C-CHECK, FOUND VOR ANTENNA NR 6303 ELEMENT IS DELAMINATED. REMOVED AND REPLACED DAMAGED ELEMENT PER EA 3450-01030. (M)
Part: PANEL — DELAMINATED (VOR ANTENNA)
OKC - DURING C-CHECK, FOUND RIGHT LOWER VOR ANTENNA PANEL IS DELAMINATED. REMOVED AND REPLACED DAMAGED SECTION PER EA 3450-01029. (M)
Part: SKIN — CRACKED (FUSELAGE)
OKC - FOUND DURING C-CHECK, NOSE GEAR, RIGHT AFT DOOR, AFT HINGE CUT OUT SKIN IS CRACKED. STOP DRILLED CRACK, COMPLIED WITH HFEC, INSTALLED RPR DOUBLER IAW 53-05. (M)
Part: FLOOR PANEL — DELAMINATED (FUSELAGE)
OKC - DURING C-CHECK, FOUND LEFT EXIT ROW 22 FLOOR PANEL IS BROKEN AND DELAMINATED. REMOVED FLOOR PANEL AND INSTALLED REPLACEMENT FLOORBOARD IAW 53-05. (M)
Part: BEAM — MISINSTALLED (FUSELAGE)
OKC - DURING C-CHECK, FOUND MID CARGO DOOR LOWER BEAM DOUBLER INSTALLED INCORRECTLY. REMOVED DOUBLER, TRIMMED AND INSTALLED NEW DOUBLER IAW ASA TASKCARD 28553001 AND 51-30-5. (M)
Part: SUPPORT ANGLE — CRACKED (FUSELAGE)
OKC - FOUND DURING C-CHECK, LEFT WHEEL WELL FORWARD INBOARD CORNER FRAME SUPPORT ANGLE IS CRACKED. REMOVED ANGLE AND INSTALLED REPLACEMENT ANGLE IAW 51-10-2. (M)
Part: FRAME — CRACKED (FUSELAGE)
OKC - DURING C-CHECK, FOUND LEFT WHEEL WELL FAIRING FRAME CRACKED AT FASTENER. REMOVED DAMAGED FRAME AND INSTALLED NEW IAW 51-30-2. (M)
Part: BATTERY — DISCHARGED (COCKPIT)
ANC PREFLIGHT CHECK, FOUND COCKPIT OVERHEAD EMERGENCY LIGHTS DO NOT ILLUMINATE WHEN TURNED ON. REPLACED ASSOCIATED BATTERY ASSEMBLY. LIGHT THEN OPERATED PROPERLY. (M)
2003
Part: CONNECTOR — DISCONNECTED (LIGHT MODULE)
SMF PREFLIGHT CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE FROM FORWARD GALLEY TO ROW 2. RECONNECTED LOOSE LIGHT MODULE CONNECTOR. LIGHTS THEN OPERATED PROPERLY. (M)
Part: LIGHT — INOPERATIVE (CABIN)
ANC - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY. LIGHT THEN OPERATED PROPERLY. (M)
Part: LANYARD — DISCONNECTED (ESCAPE SLIDE)
PREFLIGHT CHECK, FORWARD SERVICE (R-1) DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)
Part: WIRE — DISCONNECTED (EMERGENCY LIGHT)
PDX - PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTING INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED WIRING. LIGHTS THEN OPERATED PROPERLY. (M)
Part: WEB — CORRODED (FUSELAGE)
OAK - DURING C-CHECK, RT CABIN FLOOR MEMBRANE IS CORRODED BETWEEN FS 1193 AND 1211. INSTALLED DOUBLER PER SRM 53-01, 51-30-3, AND 51-10-3. (M)
Part: LANYARD — DISCONNECTED (R1 DOOR SLIDE)
LAX - DURING PREFLIGHT CHECK, FOUND RIGHT FORWARD (R-1) SERVICE DOOR GIRT-TO-SLIDE COVER LANYARD DISCONNECTED. REATTACHED LANYARD. (M)
Part: SWITCH — INOPERATIVE (EMERGENCY LIGHT)
SEA - DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHTING WAS DETERMINED TO BE INTERMITTENTLY INOPERATIVE. REPLACED OVERHEAD EMERGENCY LIGHT SWITCH IN COCKPIT. LIGHTS THEN OPERATED PROPERLY. (M)
2002
Part: BATTERY PACK — DISCHARGED (CABIN)
PDX - FOUND OVERHEAD EMERGENCY SPOT LIGHT FOUND INOPERATIVE AT ROW 19-21. REPLACED ASSOCIATED POWER SUPPLY, BATTERY PACK. LIGHT THEN OPERATED PROPERLY. (M)
Part: LANYARD — DISCONNECTED (ESCAPE SLIDE)
DURING PREFLIGHT CHECK LANYARD BETWEEN GIRT BAR AND SLIDE COVER WAS FOUND DISCONNECTED. REATTACHED LANYARD.
Part: LANYARD — DISCONNECTED (EVAC SLIDE)
SEA - DURING PREFLIGHT CHECK, THE FORWARD SERVICE DOOR EMERGENCY SLIDE 'CLIP FELL OUT' LANYARD DISCONNECTED. REATTACHED LANYARD. (M)
Part: HINGE FITTING — CORRODED (T/E FLAP)
PAE - DURING 30K CHECK, FOUND LEFT OUTBOARD FLAP INBOARD HINGE BEARING RETAINER HOLES AND SCREWS CORRODED. REPAIRED BEARING RETAINER HOLES PER EA 5750-01625, AND REPLACE FASTENERS PER SRM 51-30. (M)
Part: CHANNEL — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FOUND CORROSION ON HAT CHANNEL AT FS 1106 AND 1155. REPLACED CHANNEL PER SRM 53-01. (M)
Part: SKIN — CRACKED (CARGO DOOR)
PAE - DURING 30K CHECK, FOUND MID CARGO BAY DOOR TO BE CRACKED AT INNER SKIN OF LIGHTENING HOLE AT LOWER SIDE NEAR INNER HANDLE MECHANISM. REPAIRED SKIN PER EA 5230-01162. (M)
Part: HINGE FITTING — CORRODED (T/E FLAP)
PAE - DURING 30K CHECK, FOUND RIGHT OUTBOARD FLAP CENTER HINGE SUPPORT ON WING REAR SPAR TO BE CORRODED IN TWO BEARINGS RETAINER HOLES. FASTENERS WERE ALSO CORRODED. REPAIRED BEARING RETAINER HOLES PER EA 5750-01625, AND REPLACE FASTENERS PER SRM 51-30. (M)
Part: RETAINER — CORRODED (T/E FLAP)
PAE - DURING 30K CHECK, FOUND LEFT OUTBOARD FLAP CENTER HINGE BEARING RETAINER HOLES AND SCREWS CORRODED. REPAIRED BEARING RETAINER AND REPLACED SCREWS PER EA 5750-01625. (M)
Part: WEB — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FOUND CORROSION ON FORWARD PASSENGER (L-1) DOOR WEB FS 1118, 1152, AND 1160. REPLACED WEB PER SRM 51-30-02 AND 51-30-05. (M)
Part: DOOR FRAME — CRACKED (FUSELAGE)
PAE - DURING 30K CHECK, AFT CARGO DOOR FRAME WEB WAS DETERMINED TO BE CRACKED AT LIGHTNING HOLE, FS STATION 1214. REPAIRED WEB CRACKS PER EA 531-02059. (M)
Part: DOOR FRAME — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, MID CARGO LOWER BEAM WAS DETERMINED TO BE CORRODED ON VERTICAL AND HORIZONTAL FACES FROM FS 636-693 AND GOUGED FROM 655-689. REPAIRED DOOR BEAM PER EA 5310-02063. (M)
Part: DOOR FRAME — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FORWARD CARGO DOOR THRESHOLD LOWER BEAM WAS DETERMINED TO BE CORRODED AT FASTENER HOLES FROM FS 375-420. REMOVED CORROSION AND REPAIRED BEAM PER EA 53-10-02054. (M)
Part: SKIN — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FUSELAGE EXTERIOR SKIN WAS DETERMINED TO BE CORRODED AT CENTER OF LOWER LOBE, FS 1080, BETWEEN ENDS OF WING BODY FAIRING RUBSTRIPS. REMOVED CORROSION PER EA 5330-01566. (M)
Part: LIGHT — INOPERATIVE (CABIN)
PAE - DURING LINE CHECK, FOUND FORWARD PORTABLE EMERGENCY LIGHT TO BE INOPERATIVE. REPLACED PORTABLE EMERGENCY LIGHT ASSEMBLY. LIGHT THEN OPERATED NORMALLY. (M)
Part: DOOR FRAME — CRACKED (FUSELAGE)
PAE - DURING 30K CHECK, AFT CARGO DOOR FRAME WEB WAS DETERMINED TO BE CRACKED AT LIGHTNING HOLE AT FS 1214, WL 16, AND BUTTOCK LINE 46. REPAIRED CRACK PER EA 5310-02059. (M)
Part: WEB — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FOUND CORROSION ON OUTBOARD WEB FROM FS 522-541. REPLACED WEB SECTION FROM FS 503-600 PER SRM 51-30-02 AND 51-30-05. (M)
Part: SEAT TRACK — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FOUND CORROSION ON SEAT TRACK AT FUSELAGE STATION 1212-1296, BUTTOCK LINE PLUS 22. REPLACED SEAT TRACK PER SRM 53-05. (M)
Part: SEAT TRACK — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FOUND CORROSION ON SEAT TRACK AT FUSELAGE STATIONS, 1118, 1152, AND 1160, AT BUTTOCK STATION X PLUS 54, AND WATERLINE 2-2. REPAIRED SEAT TRACK PER SRM 53-05, FIG 4F. (M)
Part: WEB — CORRODED (FUSELAGE)
PAE - DURING 30K CHECK, FOUND CORROSION ON FLOOR WEB BETWEEN FS 608 AND 693. EXTEND WAS DETERMINED TO BE BEYOND LIMITS. REPLACED CORRODED WEB PER SRM'S 51-10-04 AND 51-30-02. (M)
Part: FRAME — CORRODED (FUSELAGE)
PAE - DURING 30K-CHECK, FOUND CORROSION ON AFT SIDE OF FRAME AT FUSELAGE STATION 1250 BETWEEN LONGERON 30 AND 29R. REPAIRED FRAME PER SRM 53-03, FIG 2A. (M)
2001
Part: WIRE — BROKEN (CABIN)
PDX - DURING PREFLIGHT CHECK, DETERMINED EMERGENCY TRACK LIGHTING TO BE INOPERATIVE IN FIRST CLASS. REPAIRED BROKEN CONNECTOR LEAD. LIGHTS THEN OPERATED PROPERLY. (M)
Part: BATTERY PACK — DISCHARGED (CABIN)
SEA - DURING LINE CHECK, FOUND THAT FORWARD EMERGENCY FLOOR TRACK LIGHTS ILLUMINATED WHEN POWER IS TURNED OFF. REPLACED BATTERY PACK AT B5-24. ALL LIGHTS THEN OPERATED PROPERLY. (M)
Part: BATTERY PACK — DISCONNECTED (CABIN)
PDX - DURING PRE-FLIGHT CHECK, FUOND THE FIRST CALSS EMERGENCY FLOOR TRACK ILGHTS ILLUMINATED WITH LIGHT SWITCH AND BATTERY ON AND OFF. COACH LIGHTS DID NOT ILLUMINATE. REPLACED BATTERY PACK AT B5-24. ALL LIGHTS THEN OPERATED PROPERLY. (M)
Part: WIRE — DAMAGED (CABIN)
FAI - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE ROWS 1 THROUGH 6. REPAIRED FLOOR WIRING AT ROW 3. LIGHTS THEN OPERATED PROPERLY. (M)
Part: LIGHT — DISCONNECTED (CABIN)
ANC - DURING LINE MAINTENANCE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE AT ROW 3. SECURED CONNECTION TO LIGHT ASSEMBLY. LIGHTS THEN OPERATED NORMALLY. (M)
Part: CONNECTOR — DAMAGED (CABIN)
SEA - DURING PREFLIGHT, FOUND EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE IN FIRST CLASS. REPAIRED CONNECTION. LIGHTS THEN OPERATED PROPERLY. (M)
Part: LAMP — INOPERATIVE (CABIN)
PDX - DURING LINE CHECK, PORTABLE EMERGENCY LIGHT ASSEMBLY WAS DETERMINED TO BE INOPERATIVE. REPLACED LAMP (BULB) WITHIN LIGHT ASSEMBLY. LIGHT THEN OPERATED NORMALLY. (M)
Part: BATTERY PACK — DISCHARGED (CABIN)
SEA - DURING PRE-FLIGHT, OVERHEAD EMERGENCY LIGHTS AT ROWS 28-30 FLASHED ON WHEN AUX HYD PUMP WAS TURNED ON. REPLACED ASSOCIATED BATTERY PACKS. LIGHTS THEN OPERATED NORMALLY. (M)
2000
Part: BATTERY — INOPERATIVE (MID CABIN)
DURING MAINTENANCE CHECK, TRACK LIGHTS AT ROW 13-22 WERE FOUND TO BE INOP. REPLACED BATTERIES, LIGHTS OPERATED NORMALLY.
Part: POWER SUPPLY — DISCHARGED (MID CABIN)
DURING MX CHECK THE CEILING EMERGENCY LIGHTS AT ROWS 9-11 WERE FOUND TO BE INOPERATIVE.REPLACXED THE POWER SUPPLY AND THE LIGHTS OPERATED NORMALLY.
Part: BATTERY — DISCHARGED (CABIN)
OAK-DURING C06 CHECK, EMERGENCY FLOOR TRACK LIGHTING DETERMINED TO BE INOP IN FIRST CLASS CABIN. REPLACED BATTERY ASSEMBLY. OPS CHECKED NORMALLY.
1999
Part: BATTERY PACK — DISCHARGED (CABIN)
PHX - DURING C-CHECK, THE OVERHEAD EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE AT ROWS 13 THROUGH 20. REPLACED PACK BATTERIES AND LIGHTS OPERATED NORMALLY. (X)
Part: MECHANISM — OUT OF ADJUST (L1 DOOR)
ANC - AFTER ARRIVAL OF FLIGHT 88, CREW REPORTED THE L1 DOOR IS DIFFICULT TO OPEN AFTER CABIN HAS BEEN PRESSURIZED, OPERATION NORMAL ON SUBSEQUENT OPENINGS. INSPECTED L1 DOOR AND ACCOMPLISHED GROUND PRESSURIZATION CHECK TO 6.0 PSID, NO DEFECT NOTED AND FOUND OPENING FORCE WITHIN DC9 MM LIMITS. ADJUSTED DOOR ROTATION ROD AS PRECAUTION AND OPERATED NORMALLY. (M)
Part: MECHANISM — LACK OF LUBE (L1 DOOR)
FAI - AFTER ARRIVAL OF FLIGHT 115, CREW REPORTED THE L1 DOOR WAS DIFFICULT TO OPEN. LUBRICATED DOOR OPERATING MECHANISM AND OPERATED NORMALLY. (M)
1998
Part: HOLD OPEN HOOK — BENT (PAX DOOR)
SEA - PRIOR TO DEPARTURE OF FLIGHT 318, CREW REPORTED THE L1 DOOR WAS DIFFICULT TO OPEN AND HOLD OPEN LATCH WOULD NOT LINE UP. REPLACED DOOR HOLD OPEN HOOK AND OPERATED NORMALLY. (M)
Part: LIGHT — INOPERATIVE (CABIN)
SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
Part: LATCH — MALFUNCTIONED (PAX DOOR)
SEA - DURING MAINTENANCE CHECK, THE L1 DOOR WOLD NOT RELEASE FROM THE LATCHED OPEN POSITION. ADJUSTED THE DOOR HOLD OPEN LATCH RELEASE MECHANISM AND OPERATED NORMALLY. (M)
Part: LATCH — LACK OF LUBE (L1 DOOR)
SFO - PRIOR TO DEPARTURE OF FLIGHT 420, CREW REPORTED THE L1 DOOR WOULD NOT LATCH OPEN. LUBRICATED THE DOOR HOLD OPEN LATCH MECHANISM AND OPERATED NORMALLY. (X)
Part: BATTERY — DISCHARGED (CABIN)
SEA - DURING MAINTENANCE CHECK, THE AFT OVERWING EMERGENCY EXIT IDENTIFIERS WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND OPERATED NORMALLY. (M)
Part: BATTERY PACK — DISCHARGED (AFT CABIN)
SEA - DURING MAINTENANCE CHECK, THE AFT TWO OVERHEAD EMERGENCY EXIT LIGHTS AND LOWER TAILCONE LIGHTS WERE FOUND INOPERATIVE. REPLACED BATTERY PACK AND LIGHTS OPERATED NORMALLY. (M)
Part: LIGHT — INOPERATIVE (L-1 DOOR)
SEA - DURING MAINTENANCE CHECK, THE PORTABLE EMERGENCY EXIT LIGHT AT THE L-1 DOOR WAS FOUND INOPERATIVE. RELAMPED AND LIGHT OPERATED NORMALLY. (M)
Part: SKIN — DAMAGED (NLG WW)
SEA - LEFT FORWARD CORNER OF NOSE LANDING GEAR WHEEL WELL WAS DAMAGED DURING PUSHBACK BY A TUG. THE DAMAGE WAS FOUND TO BE WITHIN SRM LIMITS. REPLACED LOOSE BLIND FASTENERS PER THE SRM AND RELEASED AIRCRAFT PER PLT DEFERRAL, WITH REINSPECTIONS TO BE ACCOMPLISHED AT 'A' CHECKS. DURING 15K CHECK, REPLACED THE FRAME SEGMENT AND MADE REPAIRS TO THE SKIN PER SRM 53-14-1. (M)
1997
Part: WIRE — DISCONNECTED (CABIN)
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 1 TO 4 WERE INOPERATIVE. RECONNECTED WIRE IN TRACK AT ROW 4 AND OPERATED NORMALLY. (M)
Part: LANYARD — DISCONNECTED (TAILCONE)
ANC - DURING INSPECTION OF THE TAILCONE EMERGENCY EVACUATION SLIDE THE AUTOMATIC DEPLOY LANYARD WAS FOUND DISCONNECTED FROM THE GIRT TAB. CONNECTED THE AUTOMATIC DEPLOY LANYARD TO THE GIRT TAB. (M)
Part: RELEASE MECH — OUT OF ADJUST (TAILCONE)
SEA - DURING MAINTENANCE TEST, THE TAILCONE FAILED TO DEPART THE AIRCRAFT WHEN THE EMERGENCY RELEASE HANDLE WAS ACTIVATED FROM THE AFT CABIN ENTRY DOOR POSITION. FOUND THE AFT RELEASE MECHANISM CLIPS ADJUSTMENT TOO TIGHT. ADJUSTED THE CLIP TENSION IAW DC-9 MM AND ACTIVATED THE EMERGENCY RELEASE HANDLE, TAILCONE DEPARTED THE AIRCRAFT AND DROPPED NORMALLY. (M)
1996
Part: FIRE WARNING — SOUNDED (APU)
GEG - FLT 305 - CREW REPORTED, APU AURAL FIRE WARNING SOUNDED DESCENDING THROUGH 8500 FEET IN RAIN, NO VISUAL INDICATION NOTED. PERFORMED APU/ENGINE FIRE WARNING TEST, NO FAULT FOUND. (M)
Part: LIGHT — DEFECTIVE (CABIN)
SFO - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
Part: LIGHT — INOPERATIVE (CABIN)
PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
Part: PORTABLE LIGHT — DEFECTIVE (CABIN)
SEA - DURING MAINTENACNE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
Part: SLIDE — FAILED (TAILCONE)
OAK - DURING C-CHECK, THE TAILCONE EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE TAILCONE EMERGENCY EVACUATION SLIDE. (M)
Part: MECHANISM — LACK OF LUBE (L1 DOOR)
ANC - FLT 112 - AFTER ARRIVAL, CREW REPORTED THE L1 DOOR WAS DIFFICULT TO OPEN. CLEANED AND LUBRICATED DOOR MECHANISM AND OPERATED NORMALLY. (X)
1995
Part: PORTABLE EEL — DEFECTIVE (CABIN)
LAX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)