N996JL
Registered owner: JETBLUE AIRWAYS CORP, NY (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
No operator established for this aircraft.
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
15 reports on file, 2019-11-30 – 2026-10-26.
Part: UNKNOWN — ODOR (CABIN) · airframe 29,415 hrs · 9,274 cycles
FLT 2725, JFK-TPA. ODOR EVENT PASSING THRU 10,000 INFLIGHT INFORMED CA @ 10000 FT OF A CHEMICAL ODOR IN AFT GALLEY, COMPLIED WITH INFORMATION NOTICE 2017-T015 STEP 1, ISOLATED FAULT TO TYPE 10 PER TSM 05-50-00-810-085-B/TSM 05-50-00-810-085-D. AIRCRAFT IS OK FOR SERVICE.
Part: TARGET — FAULTED (ZONE 800) · airframe 27,166 hrs · 8,601 cycles
FLT # 1002 FLL-FLL. "N996-FLT-1002-FLL-JFK-RTF CARGO THE A/C RETURNED TO THE FIELD IN FLL DUE TO AN AFT CARGO DOOR INDICATION. THE A/C LANDED WITHOUT INCIDENT AND WAITING FOR A GATE. THE TARGET POSITION SENSOR FOR THE DOOR IS FAULTED MX HAS BEEN CONTACTED TO REPAIR OR DIFFER THE INDICATION. (PILOT REPORT: AFT CARGO DOOR IND ( ECAM DOOR PAGE INDICATIONS 3) CARGO DOOR (FWD/AFT & BULK) ). ; PERFORMED TSM 52-32-00-810-801A CLEANED SENSOR (32WV) AND PERFORMED OPS CHECK OF INDICATION. FAULT CLEARED, EXCESSIVE GREASE AND DIRT ON SENSOR. CLEARS MDDR # 6111170 MX-4 UPDATED MCC-NOTIFIED PLACARD REMOVED."
Earlier reports · 2019–2025 · 13 reports
2025
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 24,718 hrs · 7,871 cycles
FLT#2752, SJU-TPA.(DURING MAINTENACE) "EMERGENCY LIGHT TEST FAILED 10WL BATTERY; REMOVED & REPLACED EMERGENCY LIGHT BATTERY FIN (10WL) PER AMM 33-51-38"
Part: SLIDE — UNWANTED DEPLOY (ZONE 800) · airframe 23,963 hrs · 7,651 cycles
FLT#383, JFK-MCO. 'DURING REPLACEMENT OF THE OVER WING SLIDE RESERVOIR INADVERTENT SLIDE DEPLOYMENT OCCURRED ON THE R2 DOOR; REMOVED AND REPLACED R2 OVERWING SLIDE IAW AMM 25-62-47. OPS CHECK GOOD.'
Part: FILTER — ODOR (ZONE 100) · airframe 23,400 hrs · 7,470 cycles
FLT#1501, JFK-FLL. ' LEVEL 2 FUME EVENT. STRONG PERSISTENT CHEMICAL FUMES ON DESCENT. SMELLED BY BOTH PILOTS AND FWD FLIGHT ATTENDANTS SUSPECT PACK 1; COMPLIED WITH INFO NOTICE 2017-T015 SECTION "A" ISOLATED FAULT TO TYPE 10 AMBIENT AIR ODOR PER TSM 05-50-00-810-085-B. REPLACED RECIRCULATION FILTERS REF AMM 21-21-41. ACFT IS OK FOR SERVICE.'
2024
Part: LEVER — MALFUNCTIONED (L4 DOOR) · airframe 21,507 hrs · 6,882 cycles
FLT#751, JFK-CUN. 'L4 DOOR SLIDE INDICATION ON DOOR/OXY ECAM PAGE DOOR ARMING LEVER COMES UP AFTER A WHILE AFTER BEING PUSHED DOWN INTO ARMED POSITION; PERFORMED OPS CHECK ARMED LEVER IAW AMM 52-10-00-720-001.TEST SATISFACTORY.'
Part: NONE — NONE (NONE) · airframe 21,132 hrs · 6,765 cycles
DURING HEAVY MAINTENANCE: A TEST FLIGHT WAS REQUIRED DUE TO FLIGHT CONTROL HARDWARE PREVENTIVE MAINTENANCE WHERE THE WORKSCOPE INCLUDED THE DISASSEMBLY OF SYSTEMS AND COMPONENTS THAT AFFECT THE OPERATIONAL CHARACTERISTIC OF THE AIRCRAFT THE AIRCRAFT PASSED ALL TESTING; INFORMATION NOTED BY MAINTENANCE PER TSI 64339. TEST FLIGHT PARAMETERS REVIEWED BY MCC DUTY MANAGER WILSON PIEDRA AND CONFIRMED SUCCESSFUL. AIRCRAFT OK FOR SERVICE.
Part: CONTROL CABLE — FAULTED (R1 DOOR SLIDE) · airframe 19,851 hrs · 6,359 cycles
FLT#362, SJU-BOS. ' R1 DOOR WILL NOT ARM; REMOVED AND REPLACED R1 EMERGENCY ESCAPE SLIDE FLEXIBLE CONTROL ASSY IN REF AMM 52-11-22. OPS CHECK GOOD.'
2023
Part: CONTROL VALVE — FAILED (23HB) · airframe 17,636 hrs · 5,701 cycles
FLT#1924, STI-BOS. (AIRCRAFT PERFORMED AN AIR TURN BACK TO STI AND DECLARED AN EMERGENCY) ' CABIN TEMP 96 DEG F ON CLIMB WHILE USING PACK 1 REF LP 3656595, ITEM 1 (PRESS CABIN ALTITUDE HIGH WARNING IN FLIGHT CLIMBING THROUGH 18K CABIN PRESSURE CLIMBED TO 11'000, TEMP TO 96 F. ( MANUAL CABIN PRESSURE CONTROL SYSTEM )). PACK 2 WAS PREVIOUSLY PLACED ON MEL REF MDDR 516413 ( PACKS ); REF LP 3664451, ITEM 1 FOR CORRECTIVE ACTION OF PACK 2. FOUND FCV ON #1 PACK AT FAULT FOR PACK 1 FAIL. REMOVED AND REPLACED PACK 1 FCV PER AMM 21-51-51. OPS AND LEAK CHECK OK AT THIS TIME. NO FURTHER FAULTS FOR PACK SYS WERE NOTED. OK FOR CONT SVC. MDDR 516416 CLEARED. MX-4 UPDATED. PLACARD REMOVED.'
Part: UNKNOWN — UNKNOWN (UNKNOWN) · airframe 17,636 hrs · 5,701 cycles
FLT#1924, STI-BOS. (AIRCRAFT PERFORMED AN AIR TURN BACK TO STI) PRESS CABIN ALTITUDE HIGH WARNING IN FLIGHT CLIMBING THROUGH 18K CABIN PRESSURE CLIMBED TO 11'000, TEMP TO 96 F. ( MANUAL CABIN PRESSURE CONTROL SYSTEM ). REF L/P 3656598 FOR CORRECTIVE ACTION. MX-4 UPDATED. PLACARD REMOVED. MDDR CLEARED.
Part: BATTERY PACK — NO TEST (DOOR SLIDE) · airframe 15,654 hrs · 5,091 cycles
FLT#369, BOS-FLL. 'DURING REMOVAL AND REPLACEMENT OF EMERGENCY BATT'S PER T/C A321-33-51-00-710-003 13WL EPSU FAULTING INTERIOR & EXTERIOR LTS; REMOVED AND REPLACED ESCAPE SLIDE RAFT L4 DOOR IAW AMM 25-62-44. THE OPS CHECK IS GOOD. NO MESSAGE OR FAULT NOTED AT THIS TIME. A/C OK TO CONT TO SERVICE.'
2022
Part: ACTUATOR — FAULTED (SLAT SYS) · airframe 15,105 hrs · 4,912 cycles
FLT#2536, STI-JFK. DECLARED AN EMERGENCY, ON THE FINAL APPROACH. SLATS INOPERATIVE. LANDED SLATS ZERO UAPP = 166K. SLAT ACTUATOR 6091CM WAS REPLACED AND OPS TEST WAS PERFORMED, REVIEWED CFOS/PFR, F/CTL HISTORY NOTED A/C ECAM FAULT "SLT 1 SYSTEM JAM"/SLT 2 SYS JAM. PRESSURIZED ALL HYD SYSTEMS AND CYCLED FLAP/SLATS TO FULL DEPLOYMENT & RETRACTION. NOTICED SLATS DEPLOYING AND RETRACTING VERY SLOWLY; FLAPS OPERATED NORMALLY. RESET FLP/SLT SYS'S 1&2. FLP/SLT DEPLOYMENT/RETRACTION ABNORMAL. ITEM #1 REMAINS OPEN.
Part: ACTUATOR — FAILED (RT SLAT SYS) · airframe 15,105 hrs · 4,912 cycles
FLT#2536, STI-JFK. (AIRCRAFT DECLARED AN EMERGENCY) ' REF L/P 3347609 ITEM #1 CONTINUES WITH INSPECTION OF RH WING SLAT SYSTEM JAM PER TSM 27-81-00-810-810-A; CONTINUED INSPECTION OF RH SLAT JAMMED ACTUATORS, ALL OTHER ACTUATORS FOUND GOOD, WITH THE EXCEPTION OF ACTUATOR 609ICM TRACK II AS MENTIONED IN ITEM 1. REMOVED AND REPLACED SLAT ACTUATOR 609ICM PRESCRIBE BT TSM 27-81-00-810-810-A AND PER AMM 27-84-49. REQUIRES OPS CHECK SUB-TASK 27-84-49-710-050-A AND CLOSE-UP OF SLAT PANELS.'
2020
Part: UNKNOWN — MALFUNCTIONED (EMERGENCY LIGHT) · airframe 6,594 hrs · 2,155 cycles
"FT # 883, JFK-MCO. EXIT LIGHT 3R DOOR INOP; ACCOMP OPS TEST OF EMER. LTS. IN CABIN WITH ""LIGHT EMER"" PUSHBUTTON SWITCH, WITH ""EMER EXIT LT"" IN COCKPIT AND OPSTEST OF EPSU BY BITE CHECK REF AMM 33-51-00 ALL LIGHTS CK GOOD UNABLE TO DUPLICATE OK FOR SVC."
2019
Part: GROUND WIRE — LOOSE (EMERGENCY LIGHTS) · airframe 5,554 hrs · 1,829 cycles
FT # 480, OVERHEAD CEILING EMERGENCY LIGHT INOP AT ROW 24 ( OVERHEAD EMERGENCY LIGHTS ); FOUND LOOSE GROUNDING WIRE. SECURED AND PERFORMED OPS TEST OF EMERGENCY LT SYS PER AMM 33-51-11. OPS CKS OK. MX-4 UPDATED. PLACARD REMOVED, MCC NOTIFIED.