DURING RUN UP THE FLOAT WOULD NOT ARM, THE PILOT SHUT THE AC DOWN AND NOTIFIED MAINTENANCE. THE MECHANIC REMOVED AND REPLACED THE FLOAT ARM SWITCH AND THE AC WAS RETURNED TO SERVICE UPON COMPLETION OF THE FUNCTION CHECKS. (K)
TRANSITION INTO CRUISE FLT PRODUCED A LATERAL LOW FREQUENCY VIBRATION, RETURNED TO ICY. MAINTENANCE VISUALLY INSPECTED AIRCRAFT FOR DISCREPANCY, NO DEFECTS NOTED THAT WOULD CAUSE A LATERAL VIBRATION, COMPLIED WITH A OPS CHECK FLIGHT AND NO LATERAL VIBRATION WAS PRESENT, VERY WINDY CONDITIONS. ALGA (M)
COMING TO A HOVER FOR TAKE OFF. N2 DROOPED TO 94 PERCENT AT 50 PERCENT TORQUE AND STAYED THERE FOR 15 SECONDS. ABLE TO RECOVER BY BEEPING. BEFORE HOVER, N2 WAS STABILIZED AT 100 PERCENT. MAINTENANCE REPLACED STARTER GENERATOR.
UPON COMING TO A HOVER. NR 2 DROPPED TO 92 PERCENT AND TOOK UP TO 15 SECONDS TO RECOVER AT HIGH TORQUE SETTING (ABOVE 80 PERCENT) N2, WOULD NOT DROOP AT LOW TORQUE SETTING. MAINTENANCE CHANGED GOVERNOR, LINER ACTUATOR, AND CHECKED NR2 RIGGING, CHECKED GOOD.
DURING START, NR 1 ENGINE DID NOT EXCEED 30 PERCENT, PILOT ABORTED THE START AND USED BATTERY CART TO START THE AIRCRAFT. NO POWER FROM BATTERY CART, APU CIRCUIT BREAKER POPPED, UPON RESET THE PILOT OBSERVED A SPARK FROM THE OVERHEAD CIRCUIT BREAKER PANEL. THE MECHANIC REMOVED AND REPLACED THE FUEL CONTROL, AIRCRAFT BATTERY AND REPAIRED THE AIRCRAFT APU WIRING. THE AIRCRAFT WAS RETURNED TO SERVICE.
DURING A LIGHTNING STRIKE INSPECTION, FOUND CORROSION AND DEBONDING OVER SPAR AT TIP (SKIN).
LIGHTNING STRIKE INSPECTION FOUND M/R BLADE CORRODED AND DEBONDED AT TIP OF BLADE.
DAILY INSPECTION FOUND BUSHINGS AND BEARINGS WORN BEYOND LIMITS. PARTS REQUIRING REPLACEMENT: 4 EACH 206-010-338-001 SPACERS, 4 EACH 206-010-337-001 BEARINGS, 2 EACH 206-010-338-003 BUSHINGS, 2 EACH NAS6605D64 BOLTS, 1 EACH 206-010-470-101 BEARING. SUBMITTER STATED NORMAL USE CAUSED PARTS TO WEAR OUT TOO SOON. WORN PARTS TT 241.0.
DAILY INSPECTION FOUND BUSHINGS AND BEARINGS WORN BEYOND LIMITS. PARTS REQUIRING REPLACEMENT: 4 EACH 206-010-338-001 SPACERS, 4 EACH 206-010-337-001 BEARINGS, 2 EACH 206-010-338-003 BUSHINGS, 2 EACH NAS6605D64 BOLTS, 1 EACH 206-010-470-101 BEARING. SUBMITTER STATED NORMAL USE CAUSED PARTS TO WEAR OUT TOO SOON. WORN PARTS TT 241.0.
DURING DAILY INSPECTION, FOUND BUSHINGS AND BEARINGS WORN BEYOND LIMITS. PARTS REQUIRING REPLACEMENT: 4 EACH 206-010-338-001 SPACERS, 4 EACH 206-010-337-001 BEARINGS, 2 EACH 206-010-338-003 BUSHINGS, 2 EACH NAS6605D64 BOLTS, 1 EACH 206-010-470-101 BEARING. SUBMITTER STATED NORMAL USE CAUSES PARTS TO WEAR OUT TOO SOON. WORN PARTS TT, 547.7 HOURS.
DURING DAILY INSPECTION, FOUND BUSHINGS AND BEARINGS WORN BEYOND LIMITS. PARTS REQUIRING REPLACEMENT: 4 EACH 206-010-338-001 SPACERS, 4 EACH 206-010-337-001 BEARINGS, 2 EACH 206-010-338-003 BUSHINGS, 2 EACH NAS6605D64 BOLTS, 1 EACH 206-010-470-101 BEARING. SUBMITTER STATED NORMAL USE CAUSES PARTS TO WEAR OUT TOO SOON. WORN PARTS TT, 547.7 HOURS.
AFTER REMOVAL OF SHIMS IN ORDER TO COMPLY WITH TB 206L-94-169. FORWARD RING WAS FOUND CRACKED UNDER SHIM AT LT LOWER ATTACH POINT. APPARENTLY, THIS IS A STRESS CRACK CAUSED BY WORKING RIVETS IN THE INTERCOSTAL ASSEMBLY.
DAILY INSPECTION FOUND BUSHINGS AND BEARINGS WORN BEYOND LIMITS. PARTS REQUIRING REPLACEMENT: 2 EACH 206-010-338-001 SPACERS, 4 EACH 206-010-337-001 BEARINGS, 2 EACH NAS6605D64 BOLTS. NORMAL OPERATION CAUSES PARTS TO WEAR OUT TOO SOON. SPACERS, BEARINGS, AND BOLTS TT 316.9.
DAILY INSPECTION FOUND BUSHINGS AND BEARINGS WORN BEYOND LIMITS. PARTS REQUIRING REPLACEMENT: 2 EACH 206-010-338-001 SPACERS, 4 EACH 206-010-337-001 BEARINGS, 2 EACH NAS6605D64 BOLTS. NORMAL OPERATION CAUSES PARTS TO WEAR OUT TOO SOON. SPACERS, BEARINGS, AND BOLTS TT 316.9.