N120QD
Registered owner: QUEST DIAGNOSTICS CLINICAL LABORATORIES INC, PA (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| QUEST DIAGNOSTICS INC (Q5QA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
1 report on file, 2024-02-28.
Part: HEATED LIP — CRACKED (ANTI-ICE SYSTEM) · airframe 27,244 hrs · 31,335 cycles
DURING A SCHEDULED INSPECTION CRACKING WAS FOUND ON THE AFT SIDE OF THE HEATED LIP ASSEMBLY, THE CRACKING WAS IDENTIFIED BY VISUAL INSPECTION. THE PILATUS PC-12 REPAIR INVOLVES REPLACEMENT OF THE ENTIRE HEATED ANTI-ICE LIP ASSEMBLY P/N 530.24.12.151, OR P/N 530.24.12.155 THE HEATED LIP ASSY. SEEMS TO HAVE A CONSISTENT FAILURE RATE AROUND 4000 HOURS OF OPERATION. WE HAVE REPLACED SEVERAL HEATED LIP ASSEMBLIES WITHIN OUR FLEET. THIS CURRENT LIP WAS ON SINCE 1/2019 AND HAD ACCUMULATED A TOTAL TIME IN SERVICE OF 6,103.3.