N207YH
Registered owner: GRANT AVIATION INC, AK (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| GRANT AVIATION INC (ENHA) | Certificate holder | — | Matched by certificate designator |
| Inter-State Aviation, Inc. (GGSA) | Operator | on 2012-05-08 | Operator named in NTSB report |
Accident & incident history
Operated by INTER-STATE AVIATION INC (per NTSB report)
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
4 reports on file, 2005-04-26 – 2026-05-28.
Part: WIRE — BROKEN (CIRCUIT BREAKER) · airframe 10,613 hrs · 10,612 cycles
AFTER TAKE-OFF, PILOT SMELLED SMOKE AND LOOKED AT GAGES AND ENGINE OIL TEMP SHOWED "0". PILOT TURNED AROUND AND LANDED. MECHANICS FOUND A LOOSE WIRE ON MAIN BUSS, BROKEN 10 AMP CIRCUIT BREAKER AND BROKEN WIRE AT VOLTAGE REGULATOR. MECHANICS TIGHTENED LOOSE WIRE, REPLACED CIRCUIT BREAKER AND INSTALLED NEW RING TERMINAL AND REPLACED VOLTAGE REGULATOR. OPS CHECKS WERE GOOD AFTER REPAIRS.
Part: MUFFLER — LEAKING (ENGINE) · airframe 9,999 hrs · 9,998 cycles
PILOT REPORTED CO DETECTOR INDICATING. MECHANICS FOUND THE RIGHT HAND MUFFLER COUPLING LEAKING. MECHANICS REPLACED THE ATTACHING HARDWARE.
Part: CONNECTOR — LOOSE (ALTERNATOR) · airframe 7,558 hrs
PILOT REPORTED ELECTRICAL DISCHARGE. MX PERSONNEL FOUND A LOOSE CONNECTION AT ALTERNATOR. RESECURED LOOSE CONNECTION, OPS CHECK GOOD IAW C207 MM 17-41. ALTERNATOR LAST INSPECTED DURING PHASE 4 INSPECTION AT 7452.6 AFTT, NO DEFECTS NOTED.
Part: MAGNETO — INTERMITTENT (ENGINE)
MAGNETO FAILED DURING FLIGHT. UPON INSPECTION IT WAS DETERMINED THAT THE CONDENSER FAILED TO TAKE A CHARGE. THE SWIVEL TERMINAL ON THE CONTACT POINT SIDE OF THE CONDENSER WAS ROTATED AND THEN THE CONDENSER WAS ABLE TO TAKE A CHARGE. SUSPECT CORROSION AT SWIVEL, RESULTING IN AN OPEN IN THE CONDENSER. REPLACEMENT OF CONDENSER WITH CURRENT PRODUCTION CONDENSER AT NEXT OPPORTUNITY. (NM13200502744) (K)