N2772A

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
PETROLEUM HELIOperatoron 1991-06-30Operator named in NTSB report

Accident & incident history

Accident · 1991-06-30 Operator named in NTSB report
BELL 206L-1 No injuries Part 135PETROLEUM HELI

Operated by PETROLEUM HELICOPTERS, INC. (per NTSB report)

Source: NTSB case FTW91LA112

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

23 reports on file, 1995-07-28 – 1999-11-11.

OTHER · 1999-11-11 Matched by certificate designator
ATA 3416

Part: INDICATOR — FAILED (COCKPIT)

ALTIMETER INDICATES 3,000-4,000 FEET.

Source: SDR HEEA065110
FLUID LOSS · 1999-07-29 Matched by certificate designator
ATA 6730

Part: CYLINDER — LEAKING (CYCLIC)

CYLINDER LEAKING.

Source: SDR HEEA063134
FLUID LOSS · 1999-07-29 Matched by certificate designator
ATA 6730

Part: CYLINDER — LEAKING (CYCLIC)

CYLINDER LEAKING.

Source: SDR HEEA063135
OTHER · 1999-07-12 Matched by certificate designator
ATA 3444

Part: INDICATOR — BROKEN (RADIO ALTIMETER)

BROKEN AND BENT GEARS, CAUSING IT HARD TO TURN SHAFT.

Source: SDR HEEA062858
OTHER · 1999-07-12 Matched by certificate designator
ATA 2562

Part: TRANSMITTER — MALFUNCTIONED (ELT)

ELT UNIT ON WHEN SWITCHED TO ARM. TIME SINCE REPAIR 0:00 HOURS.

Source: SDR HEEA062820
OTHER · 1999-07-12 Matched by certificate designator
ATA 3444

Part: RADAR ALTIMETER — FAILED (COCKPIT)

RADAR ALTIMETER POWER OUT BELOW 25 MILLIWATTS.

Source: SDR HEEA062857
OTHER · 1999-04-08 Matched by certificate designator
ATA 7321

Part: FCU — LEAKING (ENGINE)

FUEL CONTROL LEAKING OUT START DERICH SHAFT AND BYPASS COVER. PERFORMED PRELIMINARY INSPECTION. TEST START DERICH FUNCTION AND FOUND NO LEAKAGE FROM THE SHAFT. BENCH TEST AND FOUND NO LEAKAGE FROM BYPASS COVER OR START DERICH WHEN TESTED ON THE FLOW BENCH. COULD NOT DUPLICATE PROBLEM AS STATED.

Source: SDR HEEA061771
OTHER · 1999-01-28 Matched by certificate designator
ATA 7722

Part: INDICATOR — FAILED (TOT)

TOT INDICATOR HAD NO INDICATION.

Source: SDR HEEA060369
OTHER · 1999-01-22 Matched by certificate designator
ATA 3412

Part: TRANSCEIVER — ERRATIC (COCKPIT)

RADAR ALTIMETER OFF 300 FEET AND ERRATIC.

Source: SDR HEEA060149
Earlier reports · 1995–1998 · 14 reports

1998

OTHER · 1998-07-01 Matched by certificate designator
ATA 3422

Part: GYRO — PRECESSING (COCKPIT)

DIRECTIONAL GYRO PRECESSES EXCESSIVELY IN UNSLAVE MODE.

Source: SDR HEEA0015104
OTHER · 1998-06-10 Matched by certificate designator
ATA 3416

Part: ALTIMETER — MALFUCNTIONED (COCKPIT)

NO LIGHT WITH ALTIMETER.

Source: SDR HEEA0014709
OTHER · 1998-04-21 Matched by certificate designator
ATA 7230

Part: CARBON SEAL — WORN (ENG COMP)

ENGINE REMOVED DUE TO CRACKED SCROLL. INSPECTION OF COMPRESSOR PARTS REVEALED: WORN BEYOND SERVICEABLE LIMITS ON SEAL TANGS AND TANG SLOTS. INSTALLED A NEW SEAL.

Source: SDR HEEA0014006

1997

OTHER · 1997-11-28 Matched by certificate designator
ATA 6710

Part: ACTUATOR — DEFECTIVE (M/R)

DROOP COMP DEFECT, UNABLE TO ADJUST SPREAD TO 3%. GOV WAS CHANGED AT THE SAME TIME WITH RATCHETING ARM.

Source: SDR HEEA0012140
OTHER · 1997-06-26 Matched by certificate designator
ATA 3444

Part: RADAR ALTIMETER — READS LOW (COCKPIT)

READS 300 FEET LOW AT 800 FEET. FOUND UNIT TO HAVE NO ANALOG ALTITUDE OUTPUT VOLTAGE. REPLACED INTEGRATED CIRCUITS I501, I529 AND CAPACITOR C513. REPAIRED PROBLEM. ALIGNED AND CALIBRATED UNIT. INSTALLED MOD VOLTAGE DECAL. BENCH CHECK GOOD.

Source: SDR HEEA0010316
OTHER · 1997-04-24 Matched by certificate designator
ATA 2562

Part: ELT — MALFUNCTION (COCKPIT)

ELT CAME ON AT EVERY LANDING.

Source: SDR HAIHEEA9587
OTHER · 1997-04-16 Matched by certificate designator
ATA 3452

Part: TRANSCEIVER — DEFECTIVE (COCKPIT ATC)

TRANSPONDER IDENT LIGHT DOES NOT ILLUMINATE. PERFORMED MOD 6 INSTALLING HEAT SINK ON Q415 TRANSISTOR AND REPLACED RM401 AND RM402 RESISTOR NETWORK TO COMPLY WITH MOD 7. ADJUSTED FREQUENCY. BENCH CHECK GOOD.

Source: SDR HAIHEEA9375

1996

OTHER · 1996-10-11 Matched by certificate designator
ATA 7250

Part: NOZZLE — EXCESS RUNOUT (ENGINE)

DISASSEMBLED TURBINE DUE TO N1 TIP DRAG ON TEST CELL. UPON INSPECTION OF TURBINE PARTS NOTED: EXCESSIVE RUNOUT .007 BEYOND SERVICEABLE LIMITS ON #2 NOZZLE #1 AND #2 TIP PATHS. INSTALLED A DALLAS AIRMOTIVE OVERHAULED #2 NOZZLE.

Source: SDR HEEA968227
OTHER · 1996-10-04 Matched by certificate designator
ATA 6510

Part: HANGER ASSY — OUT OF LIMITS (T/R DRIVE)

REMOVED PER ASB 206L-95-101 REV. A. (SPRING I.D. OUT OF LIMITS)

Source: SDR HEEA968142

1995

OTHER · 1995-11-21 Matched by certificate designator
ATA 3444

Part: INDICATOR — STICKS (COCKPIT)

NEEDLE STICKS, BROKEN GLASS.

Source: SDR HEEA956115
OTHER · 1995-10-05 Matched by certificate designator
ATA 6320

Part: O-RING — FAULTY (M/R XMSN)

THESE "NEW DESIGN" ORINGS FOLD OVER UPON INSTALLATION OF INPUT FLANGE CAUSING EXCESSIVE LEAKING. REPLACED "NEW DESIGN" (THINNER) ORINGS WITH "OLD DESIGN" (THICKER) ORINGS AND RETURNED TO SERVICE.

Source: SDR HEEA955839
OTHER · 1995-08-25 Matched by certificate designator
ATA 2432

Part: CELL — DEFECTIVE (DC SYS)

LOW VOLTAGE. INSPECTED BY ACCESSORY SHOP AND FOUND BATTERY CELL #17 WILL NOT TAKE A CHARGE. CELL REPLACED WITH ONE GIVEN ON CONSIGNMENT.

Source: SDR HEEA955623
OTHER · 1995-08-09 Matched by certificate designator
ATA 2436

Part: REGULATOR — DEFECTIVE (DC SYS)

GENERATOR KICKS OFF LINE.

Source: SDR HEEA955584
OTHER · 1995-07-28 Matched by certificate designator
ATA 6410

Part: BEARING — CRACKED (T/R)

INBOARD AND OUTBOARD BEARINGS CRACKED. REMOVED FROM T/R HUB S/N AFS5784, T.T. 2090:15. ALSO REMOVED 4 EACH SLEEVES 206-010-733-003. PARTS SCRAPPED LOCALLY.

Source: SDR HEEA955468