OperatorRolePeriodBasis
DENA'INA AIR TAXI LLC (J95A)Certificate holder—Matched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

2 reports on file, 2014-08-09 – 2026-08-20.

SMOKE/FUMES/ODORS/SPARKS · 2026-08-20 Matched by certificate designator
ATA 2400

Part: MOTOR — BURNED OUT · airframe 21,796 hrs · 20,874 cycles

CAPTAIN WAS PILOT FLYING. N301PT DEPARTED ANC FOR IGG. WHILE IN THE CLIMB AT ABOUT 7,000FT, SMOKE COULD BE SMELLED INSIDE THE AIRCRAFT. PILOT LEVELED OFF AND NOTIFIED ANC OF THE SMELL AND REQUESTED TO RETURN TO ANC. AT THIS POINT THERE WAS NO SMOKE. AIRCRAFT WAS VECTORED TOWARDS ANC. WHILE BEING VECTORED, THE PASSENGERS NOTIFIED THE PILOT THAT SMOKE WAS COMING OUT OF THE FLOORBOARDS. CAPTAIN THEN DECLARED AN EMERGENCY AND PROCEEDED DIRECT TO ANC AIRPORT. SHORTLY AFTER TURNING TO ANC, THE SMOKE DISSIPATED. N301PT LANDED WITHOUT FURTHER INCIDENT. UPON INSPECTION BY MAINTENANCE TEAM, DISCOVERED THE FLAP MOTOR BURNT. MAINTENANCE REMOVED AND REPLACED FLAP MOTOR WITH A KNOWN SERVICEABLE UNIT. RIGGING AND OPS CHECK SATISFACTORY. AIRCRAFT RETURNED TO SERVICE.

Source: SDR 2026FA0000676
PARTIAL RPM/PWR LOSS · 2014-08-09 Matched by certificate designator
ATA 7321

Part: FCU — FAILED (ENGINE) · airframe 16,704 hrs · 16,030 cycles

INSTALLED NEW OVERHAULD FUEL CONTROL UNIT DURING MAINTENANCE. OVERHAULED UNIT THEN FAILED AFTER A FEW SUCCESSFUL ENGINE RUNS. THE SYMPTOMS OF FAILURE WERE SLUGGISH ACCELERATION ON THE FINAL SUCCESSFUL RUN, FOLLOWED BY MIN-FLOW STARTS, APPROXIMATELY 50 PERCENT N1.