N330AA

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
AMERICAN AIRLINES, INC. (AALA)Operatoron 2006-06-02Operator named in NTSB report

Accident & incident history

Incident · 2006-06-02 Operator named in NTSB report
Boeing 767-223(ER) No injuries UNKAMERICAN AIRLINES, INC.

Operated by AMERICAN AIRLINES INC (per NTSB report)

Source: NTSB case ENG06IA018

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

23 reports on file, 1995-04-21 – 2003-03-28.

NO TEST · 2003-03-28 Matched by certificate designator
ATA 3397

Part: CONNECTOR — INOPERATIVE (EMERGENCY LIGHT)

DURING OVERNIGHT MAINTENANCE, LAST THREE EMERGENCY LIGHTS ON EXTERIOR FUSELAGE INOPERATIVE. REATTACHED CONNECTOR FOR EMERGENCY LIGHT BATTERY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20030378
NO TEST · 2003-02-22 Matched by certificate designator
ATA 3350

Part: MODULE — INOPERATIVE (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, LEFT SIDE ROWS 31-37 EMERGENCY EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT MODULE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20030226
NO TEST · 2003-02-14 Matched by certificate designator
ATA 3397

Part: WIRE — DAMAGED (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, LEFT SIDE AFT ROWS 31-37 SEATS EMERGENCY EXIT LIGHTS INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHTS WIRES. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20030198
Earlier reports · 1995–2002 · 20 reports

2002

NO TEST · 2002-05-19 Matched by certificate designator
ATA 3397

Part: WIRE — BROKEN (CABIN)

BOS - DURING OVERNIGHT MAINTENANCE, FOUND FORWARD RIGHT EMERGENCY ESCAPE PATH LIGHTING INOPERATIVE. REPAIRED BROKEN WIRE FOR FORWARD RIGHT EMERGENCY ESCAPE PATH LIGHTING PER MM. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA20020771

2001

FLUID LOSS · 2001-01-16 Matched by certificate designator
ATA 7100

Part: ENGINE — LEAKING (RIGHT)

MSP - RIGHT ENGINE LEAKING OIL IN FLIGHT, REACHING 5 QUARTS DURING DIVERT TO MSP. PRESTART 17 QUARTS, AFTER SHUTDOWN 12 QUARTS. OIL LEAK VISUALLY NOTED ON POST FLIGHT INSPECTION. AIRCRAFT HAS BEEN INSPECTED AND FOUND TO BE IN SAFE CONDITION FOR FERRY FLIGHT FROM MSP TO SFO FOR REPAIR OF RIGHT ENGINE. REMOVED AND REPLACED RIGHT ENGINE PER CARD 71-94-01. OPS AND LEAK CHECK GOOD EPR CARD 71-95-18. (M)

Source: SDR AALA20010188

2000

NO TEST · 2000-04-17 Matched by certificate designator
ATA 3350

Part: CONNECTOR — LOOSE (CABIN)

SFO - DURING OVERNIGHT, MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHT AT SEAT 28B INOPERATIVE. RECONNECTED WIRE AT SEAT 28B. SYSTEM GROUND CHECK NORMAL OPERATION. (M)

Source: SDR AALA20000663

1999

FALSE WARNING · 1999-10-30 Matched by certificate designator
ATA 3260

Part: LIGHT — DEFECTIVE (RT MLG)

ORD - FLT 0067 - ON APPROACH, RIGHT MAIN GEAR GREEN GEAR DOWN LIGHT DID NOT ILLUMINATE. CYCLED GEAR THREE TIMES, RECEIVED NORMAL GEAR DOWN INDICATION. LANDED ORD WITHOUT INCIDENT. REPLACED DOWNLOCK LIGHT CAPSULE ASSY. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)

Source: SDR AALA991643
NO TEST · 1999-08-06 Matched by certificate designator
ATA 3397

Part: WIRE — FAILED (CABIN)

SFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS UNDER FLIGHT ATTENDANT SEATS IN FIRST GALLEY AREA INOPERATIVE. REPAIRED WIRES TO EMERGENCY EXIT LIGHTS UNDER FLIGHT ATTENDANT SEATS IN FIRST GALLEY AREA. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA991148
NO TEST · 1999-06-01 Matched by certificate designator
ATA 3350

Part: SOCKET — DEFECTIVE (ROW 8B)

SFO - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT SEAT PATH LIGHTING AT 8B INOPERATIVE. REPLACED EMERGENCY EXIT SEAT PATH LIGHT SOCKET AT SEAT 8B. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA990798

1997

SMOKE/FUMES/ODORS/SPARKS · 1997-06-27 Matched by certificate designator
ATA 3425

Part: CDU — DEFECTIVE (E/E COMPT)

LHR - FLT 66 - EN ROUTE ORD-LHR - THE CDU KEYPAD PANEL BECAME HOT TO THE TOUCH. COCKPIT CREW NOTED A SLIGHT BUT DEFINITE ELECTRICAL BURNING SMELL. CREW PULLED CIRCUIT BREAKER E-29 TO SHUT OFF POWER TO THE RIGHT CDU TO ELIMNATE FIRE HAZARD. SMELL DISSIPATED, FLIGHT CONTINUED ON AND LANDED LHR WITHOUT INCIDENT. REMOVED DEBRIS CLOGGING THE RIGHT CDU COOLING VENT. REPLACED RIGHT CDU, SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA971144
NO TEST · 1997-04-21 Matched by certificate designator
ATA 3350

Part: CONNECTOR PIN — LOOSE (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHT AT PAX SEAT 33H INOPERATIVE. RESECURED LOOSE EMERGENCY EXIT LIGHT CONNECTOR PIN AT PAX SEAT 33H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA970767

1996

ELECT. POWER LOSS-50 PC · 1996-12-23 Matched by certificate designator
ATA 2421

Part: IDG — FAILED (LT ENGINE)

GIG - FLT 0973 - LEFT GENERATOR FAILURE. ATTEMPTED ONE RESET, BUT UNSUCCESSFUL. MEL REF 24-01 AUTH NR 12-368DC-B. DEFERRED LT IDG INOPERATIVE PER MEL. ACCOMPLISHED MPM 24-01 - MIC SHEET ENTERED. REPLACED THE ENGINE DRIVEN GENERATOR. RAN ENGINE GENERATOR, OPS CHKS OK. CLEARED MIC SHEET AND REMOVED PLACARD 12-368DC-8. GENERATOR LEAK CKS OK. (X)

Source: SDR AALA961885
NO TEST · 1996-10-29 Matched by certificate designator
ATA 3350

Part: CONNECTOR — LOOSE (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY EXIT LIGHTS AT PAX SEAT 2H INOPERATIVE. RESECURED LOOSE EMERGENCY EXIT LIGHT SIDEWALL CONNECTOR AT PAX SEAT 2H. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA961584
NO TEST · 1996-06-03 Matched by certificate designator
ATA 3350

Part: LIGHT — DEFECTIVE (CABIN)

SFO - DURING OVERNIGHT CHECK, COCKPIT ENTRY DOOR OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED COCKPIT ENTRY DOOR OVERHEAD EMERGENCY EXIT LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA960858

1995

SMOKE/FUMES/ODORS/SPARKS · 1995-07-26 Matched by certificate designator
ATA 2530

Part: CART — DEFECTIVE (GALLEY)

LHR - FLT NR 0116 - AFTER TAKEOFF AN ACRID ODOR WAS REPORTED IN THE MID GALLEY AREA ACCOMPANIED BY A TRACE OF SMOKE. SECURED GALLEY POWER AND ODOR DISSIPATED ALONG WITH SMOKE. LANDED LHR WITHOUT INCIDENT. REPLACED WARMING CART, NO ODOR OR SMOKE. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)

Source: SDR AALA951336
OTHER · 1995-06-28 Matched by certificate designator
ATA 5280

Part: DOOR — DAMAGED (NLG)

AFW - DAMAGE ON INNER SURFACE OF LT FORWARD NLG DOOR IN CRITICAL AREA. REPAIRED PER MRB 767-948. SRM 51-70-05 WITH 2 EXTRA PLIES. TST 35,774. CYCLES, 6,431. (X)

Source: SDR AALA950041H
OTHER · 1995-06-28 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (BS 347)

AFW - UPPER FLANGE OF TRACK HAS CORROSION OUT OF LIMITS. BLENDED AND REFINISHED. APPROVED PER MRB 767-949. TST 35,774. CYCLES, 6,431. (X)

Source: SDR AALA950042H
OTHER · 1995-06-28 Matched by certificate designator
ATA 5315

Part: FLOORBEAM — CORRODED (BS 287)

AFW - CORROSION FOUND ON FORWARD FLANGE OF CABIN FLOORBEAM UPPER CHORD AT STA 287. REPAIRED PER MRB 767-951 AND SRM 53-00-51. TST 35,774. CYCLES, 6,431. (X)

Source: SDR AALA950039H
OTHER · 1995-06-15 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (FS 287)

AFW - FORWARD FLANGE OF THE CABIN FLOOR BEAM UPPER CHORD CORRODED. DAMAGED AREA FOUND TO BE BEYOND SRM LIMITS AFTER BLENDING. ACCOMPLISHED REPAIRED PER SRM 53-00-51 FIG 202 EXCEPT WITH THE OUTBOARD VERTICAL LEG OF THE REPAIR ANGLE JOGGED DOWN BELOW THE -45 ANGLE AND STOPPED AT THE -92 ANGLE APPROVED BY ENGINEERING PER MRB767-951. (M)

Source: SDR AALA951102
OTHER · 1995-06-13 Matched by certificate designator
ATA 5347

Part: SEAT TRACK — CORRODED (BS 347)

AFW - THE OUTER HORIZONTAL FLANGE OF SEAT TRACK CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. REFINISHED BLENDED AREA PER SRM 53-00-52 FIG 101. APPROVED FOR CONTINUED SERVICE BY ENGINEERING PER MRB 767-949. (M)

Source: SDR AALA951278
OTHER · 1995-06-12 Matched by certificate designator
ATA 5315

Part: FLOOR BEAM — CORRODED (BS 347)

AFW - FLOOR BEAM AT STATION 347 RBL 48 TO RBL 78 HAS CORRODED BEYOND SRM LIMITS. BLENDED OUT CORROSION, ALODINED BLENDED AREAS. FILLED WITH BMS 5-92. FABRICATED STAINLESS STRAP. PRIMER COATED AND INSTALLED REPAIR STRAP WET. (M)

Source: SDR AALA951280
NO TEST · 1995-04-25 Matched by certificate designator
ATA 3350

Part: EEL CONNECTOR — LOOSE (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT AT RT AISLE BY PAX SEAT ROW 10H INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR AT RT AISLE BY PAX SEAT ROW 10H. SYSTEM GROUND CHECKED NORMAL OPERATION. (W)

Source: SDR AALA950735
NO TEST · 1995-04-21 Matched by certificate designator
ATA 3350

Part: EEL CONNECTOR — LOOSE (CABIN)

SFO - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHT AT PAX SEAT ROW 7G INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR AT PAX SEAT ROW 7G. SYSTEM GROUND CHECKED NORMAL OPERATIONS. (W)

Source: SDR AALA950719