N33NJ

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
NATIONAL JETS INCOperatoron 1996-01-04Operator named in NTSB report

Accident & incident history

Accident · 1996-01-04 Operator named in NTSB report
Learjet 35A-305 No injuries Part 91NATIONAL JETS INC

Operated by NATIONAL JETS, INC. (per NTSB report)

Source: NTSB case NYC96WA049

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

4 reports on file, 2016-11-23 – 2018-04-29.

FLUID LOSS; WARNING INDICATION · 2018-04-29 Matched by certificate designator
ATA 2761

Part: O-RING — DAMAGED (ACTUATOR)

CREW REPORTED MAIN HYDRAULIC QUANTITY LOW CAS MESSAGE FOLLOWED BY MAIN SYSTEM HYDRAULIC PRESS AMBER CAS MESSAGE. NORMAL BRAKE FAIL WARNING. TROUBLESHOT SYSTEM TO HYDRAULIC FLUID LOSS FROM RT SPOILER ACTUATOR AT THE INLET SWIVEL FITTING. SWIVEL FITTING WAS NOTED TO BE SLIGHTLY LOOSE AND THE O-RING OUT. AREA/TRIM WAS NOT WORKED PREVIOUSLY FOR TWO YEARS. ORDERED AND REPLACED SWIVEL AND O-RING WITH NEW. SERVICED AIRCRAFT WITH HYDRAULIC FLUID AND PERFORMED OPERATIONAL CHECKS OF ALL SYSTEMS AND PUMPS WITH NO DEFECTS NOTED. RECEIVED A NEW MAINTENANCE TIME CONTROLLED ITEM FOR THE SPECIFIC SWIVEL PART FROM THE MANUFACTURE FOR REPLACEMENT EVERY 1200 HOURS. NO PREVIOUS REPLACEMENT WAS CONTAIN WITHIN THE MAINTENANCE PROGRAM. DATE OF NEW REVISION TO MAINTENANCE PROGRAM APRIL 20, 2018.

Source: SDR JKI2018F00000
OVER TEMP; WARNING INDICATION · 2017-03-02 Unresolved
ATA 7532

Part: BLEED VALVE — STICKING (LEFT) · airframe 7,700 hrs · 4,585 cycles

DURING CLIMB OUT, LT BLEED OVERHEAD CAS MESSAGE. WOULD NOT EXTINGUISH. RETURNED TO DEPARTURE.

Source: SDR 2017FA0000096
OTHER · 2016-11-23 Unresolved
ATA 3421

Part: INDICATOR — MALFUNCTIONED (ATITUDE)

OFF FLAG DOES NOT RETRACT AFTER OR BEFORE 3 MINUTE TIME LIMIT UPON POWER UP.

Source: SDR 2017FA0000441
OTHER · 2016-11-23 Unresolved
ATA 3421

Part: INDICATOR — MALFUNCTIONED (INDICATOR)

PROCESSING NEVER STOPPED. PREVIOUS UNIT FAILED WITH A FLAG.

Source: SDR 2017FA0000442