N377FX

EMBRAER EXECUTIVE AIRCRAFT INC EMB-505 · 2018 · Fixed-wing multi-engine · 2 engines · 8 seats · Valid Registration

Registered owner: FLEXJET LLC, OH (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
Flexjet, LLC (J7SA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

9 reports on file, 2018-08-02 – 2026-07-23.

OTHER · 2026-07-23 Matched by certificate designator
ATA 3440

Part: POSITION UNIT — FAULTED (ZONE 100) · airframe 8,474 hrs · 5,787 cycles

DISCOVERED AIRCRAFT SUSCEPTIBLE TO HIGH SPEED DATA BUS (HSDB) ISSUE CAUSED BY A FAILURE OF THE XM RADIO RECEIVER. THIS AIRCRAFT IS ONE OF 17 EMBRAER PHENOM 300 AIRCRAFT IN THE FLEXJET FLEET THAT IS EQUIPPED WITH XM RADIO AND AVIONICS SOFTWARE LOAD 18.10. IN THIS CONFIGURATION, THE RECEIVER CAN GO INTO RESET MODE WHEN IT RECEIVES CERTAIN PACKETS OF DATA FROM SIRIUS XM. DURING A XM RADIO RESET, IT DRAWS DOWN THE HSDB, RESULTING IN SOME OR ALL OF FOLLOWING CAS MESSAGES: HSDB FAULT, ENGINE NO DISPATCH, E2 TT0 HTR FAIL, GND SPLR FAIL. FURTHER, IT CAN DRIVE THE FOLLOWING GTC MESSAGES: GDL69 FAIL AND FAILED DATA PATH. LASTLY, THE FOLLOWING MFD ENGINE INDICATIONS MAY BE PRESENT: YELLOW X OVER E1 AND E2 OIL PRESSURE, YELLOW X OVER N1 AND N2 ENGINE, YELLOW X OVER LT AND RT ITT, YELLOW X OVER LFE VALUE.

Source: SDR J7SA2026072300488
NO WARNING INDICATION · 2025-02-14 Matched by certificate designator
ATA 3240

Part: BRAKE ASSY — MALFUNCTIONED (ZONE 700) · airframe 6,782 hrs · 4,602 cycles

CREW REPORTED INCONSISTENT BRAKING ACTION UPON LANDING AT VNY, EXPERIENCING PULSATING BRAKE PRESSURE AND APPROXIMATELY 30% BRAKING EFFECTIVENESS, NEARLY USING THE ENTIRE RUNWAY TO STOP. A SIMILAR ISSUE OCCURRED EARLIER IN THE DAY AT KMSP, CAUSING A MISSED TURN-OFF. CREW SUSPECTED A BCU MALFUNCTION. MAINTENANCE INSPECTED MAIN BRAKE SYSTEM WITH NO DEFECTS NOTED. NO FAULTS OR FAILURES DETECTED. PERFORMED TAXI CHECKS AND HIGH-SPEED TAXI TEST WITH NO DEFECTS NOTED. WORK PERFORMED IAW EMB 505 AMM 32-41-00.

Source: SDR J7SA2025021700432
OTHER · 2024-12-22 Matched by certificate designator
ATA 2700

Part: FLT CONTROLS — UNSERVICEABLE (ZONE 100) · airframe 6,603 hrs · 4,484 cycles

PTRIM BKP FAIL OBSERVED DURING TESTING. REPLACED FCE #1 IAW EMBRAER 505 AMM 27-03-01. PERFORMED RIGGING AND OPS CHECKS; ALL CHECKS GOOD.

Source: SDR J7SA2025010600425
WARNING INDICATION · 2024-12-11 Matched by certificate designator
ATA 2700

Part: FCE — UNSERVICEABLE (ZONE 100) · airframe 6,578 hrs · 4,465 cycles

FLAP FAIL CAS RECEIVED UPON SELECTING FLAP FULL DURING APPROACH. CREW PERFORMED QRH PROCEDURE, REVERTED TO FLAPS 3, AND LANDED SAFELY. ON THE GROUND, THREE ATTEMPTS TO SELECT FLAP FULL TRIGGERED THE FLAP FAIL CAS, AND SELECTING FLAPS 0 INITIALLY FAILED TO RETRACT THE FLAPS WITHOUT A CAS MESSAGE. FLAPS RETRACTED AFTER RECYCLING THE HANDLE. REMOVED FAILED FLAP SELECT LEVER AND FCE #1. INSTALLED REPAIRED FSC AND FCE #1. RIGGED FLAPS AND PERFORMED OPS CHECK OF FLAPS AND RELATED SYSTEMS IAW PHENOM 300 AMM 27-53-00. OPS CHECK SATISFACTORY WITH NO DEFECTS NOTED.

Source: SDR J7SA2025010600427
SMOKE/FUMES/ODORS/SPARKS · 2023-12-04 Matched by certificate designator
ATA 2530

Part: COFFEEMAKER — UNSERVICEABLE (ZONE 900) · airframe 5,935 hrs · 3,995 cycles

AIR TURN BACK DUE TO VERY STRONG BURNING SMELL SHORTLY AFTER TAKEOFF. CREW DECLARED EMERGENCY AND LANDED SAFELY IN KSFB WHERE THEY EXITED 27 - R AND WERE MET BY EMERGENCY SERVICES. PERFORMED OPS CHECK FOR THE SMOKE/ABNORMAL SMELL IN THE CABIN/COCKPIT IAW PHENOM 300 FIM 21-20-00-810-801-A. FOUND ABNORMAL SMELL SOURCE TO BE AIRCRAFT HOT JUG. HOT JUG SHOWED VISUAL SIGNS OF ARCING ON WATER SIDE HEATING ELEMENT. WATER HEATING ELEMENT FOUND TO BE INOPERATIVE WHEN PERFORMING HOT JUG OPERATIONAL TEST IAW AMM 25-37-01 AND EO M25-30 DOC #APR5052530-2. REPLACED HOT JUG IAW AMM 25-37-01. HOT JUG CIRCUIT BRAKERS #37 #39 HAVE BEEN ENGAGED.

Source: SDR J7SA2023120500379
OTHER · 2022-10-03 Matched by certificate designator
ATA 2700

Part: FLT CONTROLS — FAULTED · airframe 4,787 hrs · 3,192 cycles

FCE #2 FAIL. REPLACED #2 FCE IAW EMB 505 AMM 27-03-01. RIGGING AND OPS CHECK GOOD.

Source: SDR J7SA2022110100338
WARNING INDICATION · 2022-09-09 Matched by certificate designator
ATA 2740

Part: TRIM SYSTEM — FAULTED · airframe 4,730 hrs · 3,154 cycles

WHILE IN CRUISE, PITCH TRIM NORMAL FAIL AND CREW LOST PRIMARY TRIM. CREW FOLLOWED QRH, DISENGAGED AUTOPILOT, AND LANDED WITHOUT INCIDENT AT KRKS. REPLACED #2 FCE IAW PHENOM 300 AMM TASK 27-03-01-400-801-A. RIGGING AND OPS CHECKS SATISFACTORY.

Source: SDR J7SA2022091200332
SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 2020-05-19 Matched by certificate designator
ATA 3140

Part: INDICATOR — FAILED (COCKPIT) · airframe 1,989 hrs · 1,424 cycles

DIVERTED DUE TO CREW REPORT OF ELECTRICAL SMELL ACCOMPANIED BY A #2 GIA FAIL AND ASSOCIATED CAS MESSAGES AT FL450. EMERGENCY DECLARED. NO SMOKE NOTED. EMERGENCY DESCENT NOT PERFORMED. AIRCRAFT LANDED WITHOUT INCIDENT AT KORF. AFTER LANDING, THE CREW RECEIVED A WOW CAS. REMOVED AND REPLACED #2 GIA (P/N 011-01105-40) IAW EMB-505 AMM 31-41-05. OPS CHECK GOOD.

Source: SDR J7SA202005219001
WARNING INDICATION · 2018-08-02 Matched by certificate designator
ATA 2421

Part: GENERATOR — MALFUNCTIONED (NR 2) · airframe 36 hrs · 30 cycles

NR 2 GENERATOR SPIKED TO 990 AMPS, SHED AIR CONDITIONER, AMPS WENT TO 100, AFTER 3 MINUTES THE GENERATOR SPIKED TO 990 AMPS, SHED THE RT WINDSCREEN, AMPS WENT TO 90 AMPS. AFTER 30 MINS CLOSE TO LANDING, AMPS SPIKED TO 800 AMPS, SHED THE RT GENERATOR, AMPS STAYED AT ABOUT 700 AMPS. AFTER 2 - 3 MINUTES, SHUT DOWN RIGHT ENGINE. WITH RIGHT ENGINE OFF AMPS SHOWED 675 AMPS. TROUBLESHOT TO AND REPLACED GEA 2 WITH AN OVERHAULED GEA IAW MM 31-41-03. LEADED SOFTWARE AND CONFIGURATION TO GEA 2 IAW MM 31-41-03. OPS CHECKED GOOD. VERIFIED CORRECT AMP DATA ON BOTH ENGINES WHILE RUNNING AND AFTER SHUT DOWN IAW MM 24-31-00.

Source: SDR DJFA201808062001