N451H

EUROCOPTER AS 350 B2 · 1999 · Valid Registration

Registered owner: ISLAND HELICOPTERS KAUAI INC, HI (owner ≠ operator)

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
ISLAND HELICOPTERS KAUAI, INC. (ILDA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

O · 2006-09-10 Matched by certificate designator
ATA 7310

AIRCRAFT COULD NOT START, INSPECTED, FOUND FUEL COKING AT INJECTION MANIFOLD INSTALLED SAME TYPE FUEL INJECTION MANIFOLD ASSY. COMPLIED WITH GROUND RUN. LEAK CHECKED AND OPERATIONAL CHECKED AND FOUND TO E GOOD. ALL WORK DONE IAW MM. (K)

Source: SDR ILD2006F00003 · FAA SDRS
O · 2006-08-16 Matched by certificate designator
ATA 7310

AC COULD NOT START ON THE 3RD FLIGHT OF THE DAY. INSPECTED ENGINE ASSY AND FOUND FUEL COOKING AT INJECTION MANIFOLD. REMOVED INJECTION MANIFOLD. AND INSTALLED SAME TYPE INJECTION MANIFOLD. COMPLIED WITH GROUND RUN AND LEAK CHECKED AND OPERATIONAL CHECKED AND FOUND TO BE GOOD. ALL WORK DONE IAW MM. (K)

Source: SDR ILD2006F00000 · FAA SDRS
O · 2006-08-16 Matched by certificate designator
ATA 7310

AIRCRAFT WOULD NOT START ON THE 3RD FLIGHT OF THE DAY. INSPECTED ENGINE ASSY AND FOUND FUEL COKING AT INJECTION MANIFOLD. REMOVED INJECTION MANIFOLD AND INSTALLED SAME TYPE INJECTION MANIFOLD. COMPLIED WITH GROUND RUN AND LEAK CHECK AND OPERATIONAL CHECK, FOUND TO BE GOOD. ALL WORK DONE IAW MM. (K)

Source: SDR ILD2006F00002 · FAA SDRS
J · 2005-09-01 Matched by certificate designator
ATA 7310

ON THE FIRST FLIGHT OF THE DAY PILOT COULD NOT START THE AIRCRAFT DUE TO FUEL COKING AT GAS GENERATOR INJECTION MANIFOLD. REMOVED ENGINE ASSY AND INSTALLED SAME TYPE. CLEAR GROUND RUN AND LEAK CHECKED, OPS FLIGHT CHECK. (K)

Source: SDR ILD2005F00001 · FAA SDRS
O · 2005-05-10 Matched by certificate designator
ATA 7310

ON THE FIRST FLIGHT, ENGINE COULDN`T START DUE TO FUEL COKING AT GENERATOR INJECTION MAINIFOLD (MODULE 3 COMBINATION) INJECTION MANIFOLD WAS REMOVED AND REPLACED WITH SERVICEABLE INJECTION MAINIFOLD. AC RETURNED TO SERVICE AFTER RUN UP LEAK CHECK AND OPERATION. CHECK FLIGHT. (K)

Source: SDR ILD2005F00000 · FAA SDRS
F J · 2004-01-10 Matched by certificate designator
ATA 2913

AIRCRAFT LOST HYDRAULIC POWER DURING SEES SIGHT TOUR. PILOT MADE PRECAUTION LANDING. AIRCRAFT WAS INSPECTED AND FOUND HYDRAULIC BELT BROKEN. HYDRAULIC BELT WAS REPLACED. RUNUP AND FUNCTIONAL TESTED HYDRAULIC SYSTEM WORKS NORMAL. AIRCRAFT RETURNED TO SERVICE AFTER AN OPERATIVE FLIGHT CHECK.

Source: SDR ILD2004F00000 · FAA SDRS
J · 2000-04-28 Matched by certificate designator
ATA 7930

WHILE PILOT FLYING ON TOUR FLIGHT, NOTICED AN ENGINECHIP LIGHT ILLUMINATED. PILOT IMMEDIATELY MADE PRECAUTIONARY LANDING. INSPECTED AIRCRAFT AND FOUND THAT ENGINE CHIP PLUG HAD A DEFECT. CLEANED CHIP PLUGS AND C/W OPERATIONAL CHECK AND FUNCTIONALLY CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE. (X)

Source: SDR 20000510SH021 · FAA SDRS