Part: TRANSCEIVER — FAULTED (NR 1 HF) · airframe 12,590 hrs · 4,304 cycles
HF RADIO TRANSMISSION PROBLEM, COULD NOT TRANSMIT ON HF 1. ATTEMPTED HF1 SYSTEM TEST. HF 1 WOULD NOT TRANSMIT. PLACED ON MEL 2311E. PLACARDS APPLIED.
Part: ADIRU — FAULTED (ZONE 100) · airframe 11,457 hrs · 3,971 cycles
LEFT IRS FAULT LIGHT ON NON NORMAL COMP DEBRIEFED WITH CREW, CHECKED FOR FAULTS IN DFCS, REPLACE L ADIRU. REF FIM 34-21 TASK 839 REPLACED L ADIRU, OPS CHECK GOOD REF AMM 34-21-00.
Part: GIRT BAR — OUT OF ADJUST (ZONE 800) · airframe 7,249 hrs · 2,575 cycles
DOOR 1R SLIDE FABRIC IS TOO CLOSE RIGHT COLLAR. NEEDS ADJUSTMENT ADJUSTED GIRT BAR MATERIAL REF AMM TASK 25-66-01-601-804. NO FURTHER DEFECTS NOTED.
Part: LIGHT — BROKEN (ZONE 200) · airframe 7,011 hrs · 2,493 cycles
36C EMERGENCY EXIT PATH LIGHTING TRIM FALLEN OFF EMERGENCY LIGHT HOUSING DETACHED FROM SEAT AT ATTACH POINT INSERTS. REQUESTED MEL 3351A SEAT LOCATION IS 37A NOT 36A MEL 3351A NO MEL AVAILABLE, WILL HAVE TO GET WITH ESC FOR POSSIBLE RELIEF. REMOVED AND REPLACED BROKEN EMER LIGHT SHROUD 42-2521-3-0092. CKD NORMAL @ 37C
Part: RUDDER PEDAL — TIGHT (NOSE WHEEL WELL) · airframe 3,391 hrs · 1,242 cycles
RUDDER PEDALS WERE LOCKED OUT IN NEUTRAL POSITION SPOKE TO CREW AND CONFIRMED BOTH PILOTS AND F/O SIDE RUDDER PEDALS WERE VERY HHRD TO MOVE AND THEY NEEDED TO APPLY ALOT OF FORCE TO FREE UP PEDALS. REMOVED LEFT NOSE WHEEL WELL CEILING PANEL ASSEMBLY # 14A7901-7 FOR INSPECTION ASSEMBLY # 141A790-7. REMOVED RIGHT NOSE WHEEL WELL CEILING PANEL ASSEMBLY # 141A7901-8 FOR INSPECTION PERFORMED RUDDER PEDAL DO NOT MOVE FREELY (CAPTAINS) FAULT ISOLATION FIM TASK 27-21 TASK 813 : STEPS (D1-D3) UP TO STEP (D4) AS PER FIM TASK 27-21 TASK 813 COMPLETED STEP (D-4). STEP (D-5) TO COMPLETION REQUIRED. COMPLIED WITH VISUAL INSPECTION OF RUDDER AFT QUADRANT AS PER FIM TASK 27-21 TASK 813 STEP (D-4) NO DISCREPANCIES NOTED. LEAK CK''S GOOD PER MM 53-14-01.