Maintenance disclosures
POSSIBLE ELECTRICAL BURN SMELL ON SHUTDOWN. COULD NOT DUPLICATE OR FIND AN ISSUE OR CAUSE.
DURING MAINTENANCE INSPECTION FOUND THE AFT (F/A) FLASHLIGHT IS NOT CHARGING. REMOVED AND REPLACED EMERGENCY FLASHLIGHT IAW CMM 25-60-11. MEL CLEARED. THE AIRCRAFT WAS RETURNED TO SERVICE.
MAIN DOOR EMERGENCY LIGHT INOPERATIVE. REPAIRED BROKEN WIRE UNDER MAIN CABIN DOOR STEP IAW AWM 20-00-00, OPS CHECKED GOOD IAW 33-51-24.
MAIN DOOR NEEDS ADJUSTMENT. ADJUSTED MAIN DOOR IAW JIC 52-11-00.
THE CREW REPORTED THE MAIN PASSENGER DOOR WAS DIFFICULT TO CLOSE CAN NOT LIFT DOOR HANDLE. THE ACFT WAS REMOVED FROM SERVICE. REMOVED PAX DOOR FITTING WEB SPRINGS & SUPPORT STRUCTURE INSTALLED NEW PAX DOOR FITTING, NEW WEB SUPPORT STRUCTURE & SPRINGS IAW SRM 51-25-03. THE ACFT WAS RETURNED TO SERVICE. (OPEN)
AFTER DEPARTURE THE CREW REPORTED THE LANDING GEAR DID NOT RETRACT. THE GEAR HANDLE DID NOT MOVE OUT OF THE DOWN POSITION. THE CREW ELECTED TO RETURN TO DEPARTURE. THE ACFT LANDED WITHOUT INCIDENT. CLEANED PROXIMITY SWITCH 51GB. R & R PROXIMITY SWITCH 54GB AND HARNESS 503GVC IAW JIC 32-61-00. THE OPS CHECK WAS GOOD IAW JIC 32-31-00. THE ACFT WAS RETURNED TO SERVICE.
SUPPLEMENTAL INFORMATION---THE CORRECT NUMBER IS TRBA2011087. PLEASE DISREGARD TRBA 201087. AFTER DEPARTURE, THE CREW REPORTED THE LANDING GEAR DID NOT RETRACT. THE GEAR HANDLE DID NOT MOVE OUT OF THE DOWN POSITION. THE CREW ELECTED TO RETURN TO DEPARTURE. THE ACFT LANDED WITHOUT INCIDENT. CLEANED PROXIMITY SWITCH 51GB. R & R PROXIMITY SWITCH 54GB AND HARNESS 503GVC IAW JIC 32-61-00. THE OPS CHECK WAS GOOD IAW JIC 32-31-00. THE ACFT WAS RETURNED TO SERVICE.
STRONG SMELL OF OIL FILLED COCKPIT AND CABIN ON APPROACH WITH POWER PULLED BACK LESS THAN 10 PERCENT IN ATTEMP TO ISOLATE THE SOURCE. IT APPEARS TO BE COMING FROM THE NR 1 PACK/BLEED AFTER FOLLOWING APPROPIATE CHECK LISTS. DURING BOROSCOPE INSPECTION OF L/H ENGINE INLET FOUND NUMEROUS LP IMPERLLER VANES DAMAGE. REMOVED AND REPLACED LT ENGINE IAW W/C EX-72-RAI-001.
(DECLARED EMERGENCY) AFTER LANDING 13R & TAXI IN WHILE CROSSING 18L AND SELECTING REVERSE TO SLOWDOWN A STRONG ACRID ODOR OF SMOKE WAS NOTED FROM COCKPIT AND ALSO NOTED IN FWD AND REAR CABIN. THE F/O SAW WHITE SMOKE ORIGINATING FROM TOP OF GLARESHIELD VENTS OVER TO THROTTLE QUADRANT. THIS WAS VERY BRIEF, IMMEDIATLY SHUTDOWN THE RECIRCS AND BLEEDS WHILE PARKING AND THE SMELL DISSIPATED. R & R LT ACM IAW JIC 21-51-52. DURING INSP FOUND ACM SEIZED, R & R TURBINE INLET CONTROL VALVE IAW JIC 21-51-98. THIS ACTION REQUIRES OPS CK. OPS CHECK TRANSFERED TO LOG PAGE 314620, ITEM 1. LOG PAGE 314619 FOUND BROKEN WIRE AT CONNECTOR 17HBA AND THE CONNECTOR IS CORRODED FOR OVERTEMP SENSOR, REPLACED CONNECTOR PLUG 17HBA AND REPAIRED WIRE IAW SPM 20-44-17. LOG PAGE 314620, ITEM 1, PERFORMED OPS CHECK OF LT TIC VALVE IAW ATR JIC 21-51-98. OPS CHECK GOOD AND OPS CHECKED LT ACM IAW JIC 21-51-00. OPS CHECK GOOD.
AFTER T/O ENGINE NR1 HAD A COMPRESSOR STALL. TORQUE SPIKED 10 PERCENT. PERFORMED GROUND RUN PERFORMANCE CHECK NR1 ENG IAW ATR72 JIC 72-00-00-ERU 10040. NO DEFECTS NOTED. CANNOT DUPLICATE. ACFT TAKEN OUT OF SERVICE FOR SUSPECTED COMPRESSOR STALLS ON NR1 ENG. R & R NR1 ENGINE INTER COMPRESSOR BLEED VALVE (IBV) AND (IBV) SERVO VALVE ON NR1 ENGINE IAW MM 72-01-30. ENGINE NR1 GROUND RUN, NR1 ENG IBV AND SERVO VALVE. OPS TEST GOOD IAW MM 72-01-30.
1/2 FWD LIGHT STRIPS INOP ALL 4 EMERGENCY DOOR EXIT LIGHTS INOP. WAITING FOR AML PAGE FOR FURTHER DETAILS. R & R FWD PAX COMPARTMENT EMERGENCY LIGHTS POWER SUPPLY BATTERY PACK IAW JIC 33-51-21. OPS CHECK OK.
DURING APPROACH, FLAP MOVE VERY SLOW FROM 15 DEGREES TO 30 DEGREES, EXT FLAG STAYED ON. FEW SECONDS AFTER REACHING 30 DEGREES, RECEIVED WARNING FLAP UNLOCK ON CAP EXECUTED GO AROUND FOLLOWED AOM PROCEDURES AND LANDED WITH FLAPS 15 DEGREES. "EMERGENCY DECLARED" -REPEAT WRITE UP- R & R FLAP VALVE BLOCK IAW ATR-72 JIC 27-54-71.OPS CHECK AND LEAK CHECK FOUND SATISFACTORY AT THIS TIME. ACFT WILL BE RELEASED FOR FCF RII: 148806. FCF PASSED, AML 298284-1.
DURING FINAL APPROACH, WHEN SELECTING FLAP 30 EXT FLAG STAY ON THEN FLAP UNLOCK ON CCAS, EXCUTED GO AROUND "DECLARED EMERGENCY" ABLE TO LAND FLAP 15. MX INSPECTED FLAP SYS, PERFORMED OPS CK OF FLAPS 10 TO 15 TIMES, COULD NOT DUPLICATE PROBLEM IAW JIC 27-50-00. ACFT RELEASED FOR FCF PURPOSES ONLY. R & R 626256 7-16-10.
F/O'S YOKE HAS LOOSE WIRE ARCING AND SMOKING. REATTACHED BROKEN WIRE ON F/O'S CHART HOLDER LIGHT IAW SPW 20-42-21.
BURNING SMELL (LIKE BURNED INSULATION). SMELLED IN FWD CARGO COMPARTMENT ON GROUND. SMELL WENT AWAY AFTER POWER REMOVED FROM ACFT. INSPECTED AVIONICS COMPARTMENT AND GROUND RAN ACFT IAW JIC 72-00-00, NO SMELL NOTED. REF ITEM NR 2 THIS LOG PAGE, FOUND RADIO ALTIMETER EXTREMELY HOT. R & R RADIO ALTIMETER IAW JIC 34-42-81. VISUALLY CHECKED CONNECTIONS IN AVIONICS COMPARTMENT, NO DEFECTS NOTED.
WITH FLAPS AT 30 DEGREES, GOT MASTER WARNING FLAP UNLOCK. EMERGENCY DECLARED. OPS CK OF FLAP ASYMMETERY DETECTION SYS IAW JIC NR 27-51-00. ON GROUND, OPS CK GOOD.
WITH FLAPS AT 30 DEGREES, GOT MASTER WARNING FLAP UNLOCK. EMERGENCY DECLARED: OPS CK OF FLAP ASYMMETERY DETECTION SYS IAW JIC NR 25-51-00. ON GROUND OPS CK GOOD REQUIRES FCF. (DISCREP AML PAGE 265284: TRANSFERRED FROM LG PG 265283 ITEM 4 REFRENCE ITEM NR 1 OF LG PG 265282 REQUIRES FCF FOR FLAPS AT 30 NR GOT MW FLAP UNLOCK ACFT RELEASED FOR FCF PURPOSE ONLY 498531. (FCF PASSED).
LT OTBD WING AILERON CONTROL SEGEMENT CORRODED. REMOVED CORRODED SEGEMENT (BELLCRANK) LT OTBD WING INSTALLED LT OTBD SERVICABLE ROD (BELLCRANK) IAW JIC27-11-71. OPS CK GOOD.
AN AREA OF CORROSION WAS FOUND AT RT WING LOWER SKIN DRAIN VALVE BETWEEN RIB 12-13. CORROSION TEMP BLEND-OUT REPAIR PERMANENT REPAIR AT THIS AREA ON THE NEXT 3000 CYCLES OR AT NEXT C-CK INSP. C/W SRI DO/TS - 0958/08-9928 REF NDT REPORT AMS 100226-14 FOR HFEC AND UT VALUES NO DEFECTS NOTED AT THIS TIME. C/W ATR SRAS DO/TS - 958/08...4527. ACCOMPLISHED EO NR E2-57MR-369 TDMI TO REMAIN OPEN WITH SUPPLEMANTARY INSP HFEC FOR CRACK EVERY 10000 FC. DUI BLENDED AREA FOR NEW CORROSION DETECTION EVERY 2 YRS.
ELEVATOR JAMMED ENROUTE. REGAINED FULL ELEVATOR CONTROL AT TIMES. DECLARED EMERGENCY AND LANDED WITH VERY LIMITED ELEVATOR CONTROL. AT GATE ELEVATOR WORKED NORMAL. AT TIMES PITCH TRIM INDICATOR INDICATES FULL DOWN. ALSO RECEIVED PITCH MISTRIM ON ADU BUT WENT AWAY. AWAITING AML PAGE FOR FURTHER DETAILS.
ELEVATOR JAMMED ENROUTE. REQUIRED FULL ELEVATOR CONTROL AT TIMES. DECLARED EMERGENCY AND LANDED WITH VERY LIMITED ELEVATOR CONTROL. AT GATE ELEVATOR WORKED NORMAL. AT TIMES PITCH TRIM INDICATION INDICATED FULL DOWN. ALSO WE RECIEVED PITCH MISTRIM ON APU BUT WENT AWAY. TRANSFERED TO NRWC 2462204. REMOVED AND REPLACED LT ELEVATOR IAW JIC NR55-20-00 AND ETN NR E2-55-010. REF TO NRWC 2439288, 2462204, 2439701, 2439281, 2439294 AND 2439280.
FLOOR PROXIMITY EMERGENCY ESCAPE PATH LIGHT NEXT TO PAX SEAT 17B INOPERATIVE. REMOVED AND REPLACED PROXIMITY EMERGENCY STRIP LIGHT BULB IAW ATR72 JIC NR 33-51-21. OPERATIONAL CHECK GOOD.
F/A REPORTS BURNING ODOR OVER PAX SEATS 13AB AND 6CD. POSSIBLE FLUORESCENT TUBES. REMOVED AND REPLACED FLUORESCENT TUBES AND BALLASTS AT 4AB AND 14AB IAW JIC NR 33-21-23-RAI-10000-009 AND JIC NR 33-21-21-RAI-10000-007.
LT SEAT TRACK BETWEEN FRAME 36-39 CORRODED. LT SEAT TRACK BETWEEN FRAME 36-39, REPLACED AND INSTALLED AS PER SRM 51-25-04.
RT SEAT TRACK BETWEEN FRAME 39-40 CORRODED. RT SEAT TRACK BETWEEN FRAME 39-40, REMOVED IAW SRM 51-21-42.
EMERGENCY LIGHT AT AFT F/A PANEL NOT WORKING PROPERLY. REMOVED AND REPLACED BATTERY PACKS AT POWER SUPPLY UNITS FIN NR 43WL, 61WL AND 62WL IAW MM NR 33-51-21.
FLAP UNLOCK INDICATION ON APPROACH. DECLARED EMERGENCY AND ABORTED APPROACH. LANDED WITH ZERO FLAPS. PERFORMED OP CK OF FLAP VALVE BLOCK IAW JIC NR 27-54-71. REMOVED AND REPLACED FLAP POSITION INDICATOR IAW JIC NR 27-55-81. PERFORMED OP CK OF FLAP SYSTEM IAW JIC NR 27-27-51-00 AND FOUND WORKING PROPERLY.
DURING PHASE INSPECTION, FOUND SERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REPAIRED WIRE ON CONNECTOR 68WL AS PER STD PRACTICE JIC NR 20-00-00. PERFORMED OP CK IAW JIC NR 33-50-00.
FEW MINUTES AFTER TAKEOFF, MULTIPLE AURAL WARNINGS AT THE SAME TIME INCLUDING UNSAFE GEAR INDICATION. REPLACED RADIO ALTIMETER TRANSCEIVER IAW MM. (K)
DURING TAKEOFF, RIGHT ENGINE FUEL CLOG INDICATION CAME ON. ABORTED TAKEOFF. REMOVED AND REPLACED FUEL PUMP OUTLET FILTER. (M)
MIA - MAINTENANCE REPORTED SOME EMERGENCY LIGHTS WOULD NOT ILLUMINATE. MAINTENANCE REMOVED AND REPLACED ONE OF THE EMERGENCY LIGHT POWER SUPPLY UNITS. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE. (M)
DFW - FLT 3515 - EMERGENCY FLOOR LIGHTS ON AIRSTAIR INOPERATIVE. REPAIRED WIRES ON PAX DOOR FOR EMERGENCY LIGHTS IAW AMM. OPS CHECK GOOD. (M)
DFW - FLT 3400 - NOSE WHEEL UNLOCK LIGHT ON AFTER GEAR RETRACTION. REMOVED AND REPLACED NOSE LANDING GEAR LIMIT SWITCH IAW AMM. OPS CHECK GOOD. (M)
DFW - FLT 3724 - AFT CARGO SMOKE WARNING IN FLIGHT. MAINTENANCE REMOVED AND REPLACED AFT CARGO SMOKE DETECTOR IAW ATR MM. OPERATIONAL CHECK WAS SATISFACTORY AND AIRCRAFT WAS RETURNED TO SERVICE. (M)
DFW - FLT 3503 - EMERGENCY LIGHTS WILL NOT STAY ON USING FLIGHT ATTENDANT PANEL. REMOVED AND REPLACED PANEL IAW ATR AMM. OPS CHECK GOOD. (M)
DFW - FLT 3601 - PARTIAL EMERGENCY LIGHTING ROWS 1-B INOPERATIVE. OVERHEAD EMERGENCY LIGHT ROWS 7 AND 11 INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY 61WL. OPS CHECK GOOD. (X)
DFW - FLT 3858 - WHILE PERFORMING CHECK ONLY 50 PERCENT OF EMERGENCY FLOOR LIGHTS ILLUMINATED AND EXIT SIGN AT MAIN DOOR GOES OUT AFTER 5 SECONDS. REMOVED AND REPLACED BATTERY PACK AT 62WLA. OPS CHECK GOOD. (M)
DFW - FLT 3506 - FORWARD EMERGENCY EXIT LIGHT, ONE OVERHEAD, AND EIGHT FLOOR PROXIMITY LIGHTS DO NOT ILLUMINATE. REPLACED BATTERY PACK AT LOCATION 61WL. OPERATIONAL CHECK NORMAL. AIRCRAFT RETURNED TO SERVICE. (M)
GRR - FLT 5067 - EMERGENCY LIGHTS STAY ON. REMOVED AND REPLACED BATTERY PACKS AT 73WL, 63WL, AND 61WL. OPERATIONAL CHECK GOOD. (M)
ORD - FLT 4107 - REAR MOST FLOOR PROX LIGHT INOP. RAI'D BULB. PERFORMED OPERATION CHECK SATISFACTORILY AND RETURNED A/C TO SERVICE. (M)
ORD - FLT 9750 - EMERGENCY LIGHTS INOP. R/I'D BATTERY PACK AT 62WL. PERFORMED OPERATIONAL CHECK SATISFACTORILY AND RETURNED A/C TO SERVICE. (M)
GRR - FORWARD CABIN FLOOR EMERGENCY LIGHTING INOP. RAI POWER SUPPLY FOR FLOOR LIGHTING. PERFORMED OPERATIONAL CHECK SATISFACTORILY. A/C RETURNED TO SERVICE. (M)
ORD - EMERGENCY BATTERIES WILL NOT RUN EMERGENCY LIGHTS. REPLACED ALL FOUR BATTERY PACKS 43WL, 61WL, 73WL, AND 62WL. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. REF: OPERATOR CONTROL NR SIMA97227-1, 97ZZZX4163, AND 97ZZZX4164.
ORD - EMERGENCY BATTERIES WILL NOT RUN EMERGENCY LIGHTS. REPLACED ALL FOUR BATTERY PACKS 43WL, 61WL, 73WL, AND 62WL. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. REF: OPERATOR CONTROL NR 97ZZZX4163, 97ZZZX4164, AND 97ZZZX4165. (X)
ORD - EMERGENCY BATTERIES WILL NOT RUN EMERGENCY LIGHTS. REPLACED ALL FOUR BATTERY PACKS 43WL, 61WL, 73WL, AND 62WL. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. REF: OPERATOR CONTROL NR SIMA97227-1, 97ZZZX4164, AND 97ZZZX4165.
ORD - EMERGENCY BATTERIES WILL NOT RUN EMERGENCY LIGHTS. REPLACED ALL FOUR BATTERY PACKS 43WL, 61WL, 73WL, AND 62WL. OPS CHECK GOOD. AIRCRAFT WAS RETURNED TO SERVICE. REF: OPERATOR CONTROL NR SIMA97227-1, 97ZZZX4163, AND 97ZZZX4165.