N519FX
Registered owner: CITATION X PARTS LLC, NC (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| Flexjet, LLC (J7SA) | Certificate holder | — | Matched by certificate designator |
Accident & incident history
No NTSB accidents or incidents on file for this aircraft.
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
4 reports on file, 2009-12-02 – 2019-04-29.
Part: FASTENER — MISSING (LEADING EDGE) · airframe 13,794 hrs · 2,469 cycles
LT MIDDLE LOWER LEADING EDGE MISSING THREE EA. SCREWS (NEAR VORTILLON)AND MULTIPLE LOOSE HARDWARE ON LEFT AND RIGHT LEADING EDGES (RIGHT WING UPPER OUTBOARD LEADING EDGE SCREW IS LOOSE). INSTALLED MESSING HARDWARE ON LT MID LWR L/E AND TIGHTENED LOOSE HARDWARE ON THE LT AND RT LEADING EDGES (REMOVED AND REPLACED HARDWARE ON RT WING UPPER O/B L/E) IAW AMM TASK 20-20-00-910-801.
Part: SCREW — MISSING (LT WING) · airframe 12,432 hrs · 7,624 cycles
SCREW MISSING ON UNDER SIDE OF LEFT WING LEADING EDGE. REPLACED MISSING SCREW ON LEFT WING LEADING EDGE.
Part: UNKNOWN — SMOKE (COCKPIT) · airframe 8,539 hrs · 5,221 cycles
SMOKE IN THE COCKPIT JUST AFTER TAKEOFF AT 1000FT. LANDING & TAXI WERE UNEVENTFUL. INSPECTED APU INLET, DUCTING & BLEED AIR DUCTS. NO DEFECTS NOTED, BELIEVED TO BE ANTI-ICE FLUID.
Part: BYPASS VALVE — FAILED (HYD SYSTEM) · airframe 4,628 hrs · 2,787 cycles
IN FLT CREW RECEIVED AN AMBER "R HYD TEMP HIGH" MSG. TEMP INDICATED 115 DEGREES AND WITHIN A MINUTE WENT TO 158 DEGREES. CREW SHUTDOWN THE RT ENGINE. RT ENGINE SHUTDOWN IN FLT AND AN IFE DECLARED. AIR DIVERSION WITH UNEVENTFUL LANDING AND TAXI. DRAINED AND FLUSHED NR 2 HYD SYS AND SERVICED AS REQ'D. REPLACED NR 2 HYD SYS PRESSURE, RETURN, AND CASE DRAIN FILTERS. REPLACED NR 2 ENG DRIVEN HYD PUMP. BLED SYS AND RAN NR 2 ENG. REMOVED AND INSPECTED NR 2 CASE DRAIN FILTER AND REPLACED WITH NEW. LEAK CHECK GOOD. REMOVED AND REPLACED NR 2 BYPASS HEAT EXCHANGER VALVE. LEAK CHECK AND OPS CHECK SATISFACTORY.