N654AN

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
DREAMLINE AVIATION, LLC (5DLA)Certificate holderMatched by certificate designator

Accident & incident history

No NTSB accidents or incidents on file for this aircraft.

Maintenance disclosures

O · 2013-01-10 Matched by certificate designator
ATA 5311

FRAME HAS A CLAMP RIVETED TO FLANGE TO MOUNT THE NOSE O2 BOTTLE. WHERE THE CLAMP COMES OFF THE END OF THE FLANGE, TO GO AROUND THE O2 BOTTLE, THE FLANGE RADIUS IS CRACKING, BOTH THE INBD AND OTBD ENDS. DETERMINED THAT FLANGE CURVE OF FRAME IS LARGER THAN BOTTLE. ADDED A RUBBER GASKET TO INSIDE OF CLAMP TO TAKE UP THE GAP BETWEEN THE FLANGE AND THE BOTTLE. REPAIRED FRAME.

Source: SDR 2013FA0000083 · FAA SDRS