RED PATHWAY EMERGENCY LIGHT INOP FWD OF SEAT 20K . REQUESTING DEFERRAL LENS CRACKED BUT WORKING RED PATHWAY EMERGENCY LIGHT FWD OF SEAT 20K HAS A CRACK BUT WORKING. DEFERRED REF NEF 2520TP DEFERRED REMOVED AND REPLACED LIGHT ASSEMBLY. OPS TEST GOOD. REF AMM 33-51-10-962-173. (EMERGENCY WALL LIGHT.)
GALLEY 2A EMERGENCY LIGHT FOUND BROKEN REPLACED EMERGENCY LIGHT ASSY AND OPS CHECK SATISFACTORY WRT SWPM 20-30-00. PARTS USED: 25-3351-3-0008, QTY :1
FOUND PATHWAY LIGHT ON SIDE OF SEAT 39D INOP. FOUND 39F LIGHT INOP AS WELL. REPLACED BOTH PATHWAY LIGHTS AT SEATS 39D AND 39F. STILL NOT WORKING. REFERENCE CMM 25-23-52. DISCONNECTED BOTH PATHWAY LIGHTS AT 39 D&F. MEASURED 6V AT BOTH CONNECTORS AND MEASURED GOOD CONTINUITY TO GND AT BOTH CONNECTORS. RECONNECTED BOTH PATHWAY LIGHTS AT 39D&F. LIGHTS OPS CHECKED GOOD. REF WDM 33-51-15. PG2C SHEET 3. NAT DRAWING N0649-D73.
SLIDE PRESSURE DOOR 2L NOT IN GREEN PERFORMED VISUAL INSPECTION OF DOOR 2L SLIDE PRESSURE GUAGE, FOUND WITHIN TOP OF GREEN BAND, WITHIN LIMITS, REF CYLINDER CHECKTASK 25-66-02-206-001, OK TO CONTINUE.
EMERGENCY LIGHTS, LT FWD ESCAPE SLIDE EMERGENCY LIGHT INOP, ESCAPE LIGHT LAMP RESEATED AND TESTED IAW AMM 33-51-06-902-082, LIGHT NOW OPERATES.
PLEASE CHECK DOOR 2L PRESSURE GAUGE INSPECTED DOOR 2L PRESSURE GUAGE. FOUND NEEDLE ONE NEEDLE WIDTH OVER (TOWARDS HIGHER END OF BAND) IAW AMM 25-66-02 A/C OK TO CONT. NOTE: A/C CABIN WAS HOT PRIOR TO APU PACKS BEING TURNED ON.
DURING A/C REFUELING, PRIOR TO ENG OR APU START, 1 F/A REPORTED STRONG FUEL SMELL IN ACFT. NO OTHER CREW OR PASSENGERS WERE EFFECTED BY ODOR. CAPTAIN WALKED TO BACK OF ACFT ON 3 DIFFERENT OCCASIONS AND NEVER NOTICED ANY SMELL OR FUMES/ VISIBLE SMOKE. STONG SMELL DISSAPPEARED QUICKLY AFTER REFUELING COMPLETED. AFTER DEBRIEFING CREW SMELL DETERMINED TO BE NON A/C RELATED.
LOUD BANG AND BRIGHT FLASH ON LEFT SIDE AFTER TAKE OFF POSSIBLE BIRD STRIKE CREW SAID THEY FELT KICKED TO THE LEFT WITH THE LOUD BANG AND THE WHITE FLASH FROM THE LEFT SIDE, ACCMP OVERWEIGHT LANDING INSPECTION AND BIRD STRIKE INSPECTION. REF AMM TASK 05-51-35-212 & AMM 05-51-18-212-001 NO DEFECTS NOTED. ACCOMPLISHED GVI OF 1ST STAGE STATOR REF AMM 72-00-00-206-001-N01 ITEM 2.G.(1)-(2), NO DAMAGE NOTED. BORESCOPE OF #1 ENGINE HPC SECTION, REF. AMM 72-00-00-206-001, NO LIMITING DAMAGE NOTED. REINSTALLED BOROSCOPE PLUGS, CLOSED ENGINE COWLS, ACCOMPLISHED IDLE RUN AND SATISFACTORY LEAK CHECK.
OXYGEN MASKS DEPLOYED AT SEAT 11F RESTOWED PAX 02 MASKS ABOVE SEAT 11F REF AMM 35-21-15-532-150-001.
AIR RETURN FOR VIBRATIONS IN FLIGHT CONTROLS CREW DEBRIEF STATED AT 10,000 FT FELT VIBRATION IN THE CAPTS AND FOS YOKE IN CLIMB TO CRUISE AT SPEEDS OF 250,280 TO 320 THE INTENSITY RAMPED UP AND STAYED THERE IN ALL PHASES OF FLIGHT. DURING TURNS, ASCENDING AND DESCENDING. HE COULD NOT ISOLATE WHETHER IT WAS AILERONS OR ELEVATOR ASSOCIATION.NOTHING FELT IN THE RUDDER PEDALS. THE INTENSITY STEPPED DOWN TO 50% ON FINAL APPROACH WITH FULL FLAPS. NO FLAP OVERSPEED AT ANY SETTING AND NO ECIAS MESSAGES INSPECTED APU DOOR REF MM 05-51-38-202-001 PART 1(A) "VIBRATION IN FLIGHT CONTROLS" NO DEFECTS NOTED. CHECKED APU DOOR FOR PROPER FAIRING IN CLOSED POSITION AND FOR ANY DEFECTS IN OPENED POSITION. NONE FOUND PERFORMED FIM 05-00 TASK 801 OPERATE ALL FLIGHT CONTROL SURFACES WITH ALL THREE HYDRAULIC SYSTEMS PRESSURIZED, STEP A - N, NO DEFECTS NOTED. NEED TO CONTINUE FROM THIS STEP. REF AMM# 05-51 TASK 801. CONTINUED STEPS O THRU S STAB OPERATION, BLOWOUT PANELS, STAB,APU DOOR AND FLAP LEADING AND TRAILING EDGES. NO DEFECTS FOUND OTHER THAN PANEL/SEAL ON LOG#4939600 AND #4939615. STILL REQUIRES LANING GEAR AND FILLET SEAL INSPECTIONS INSPECTED FLAP SLATS STEPS A THRU J. INSPECTED BLOWOUT PANELS STEPS A THRU C. APU DOOR STEPS A THRU F. STABILIZER STEPS A THRU D. NO DEFTECTS FOUND. REF #05-00 TASK 801 FILLET FAIRING AND ACCESS PANEL VISUALLY CHECKED AND LANDING GEAR DOORS CHECKED. IRW AMM 05-51 TASK 801.
AFT LEFT DOOR PRESSURE GAUGE BELOW GREEN. VERIFIED GUAGE IS WITHIN SERVICABLE RANGE.
TEST FLIGHT DISCREPANCY . . LE EDGE SLAT ASSYMETRY I N CLIMB. POSSIBLE OVERSPAT 33000 FEET, AIR SPEED REACHED 300 KNOTS FOR A SHORT PERIOD TIME. 50 KNOTS ABOVE MAX SPEED OF 250KNOTS PLUS NOTICED L.E FLAPS INDICATIONS START TO MOVE ALSO. BELOW 250KNOTS EVERYTHING APPEARS NORMAL ...PER TEST PILOT ...TOMC MO THE PANELS FIN 521BB, 521EB, 521JB, 521TB, 521ZB AND 521AFB OF THE LEADING EDGE SLAT SENSOR SWITCH WERE REMOVED AS PER AMM 57-41-01-000-801. PERFORMED OVERSPEED PHASE I INSPECTION AS PER. AMM 05-51-08-212-001. NO DAMAGE WAS FOUND DURING PHASE I INSPECTION. ACCOMPLISHED FLAP/SLAT ELETRONIC UNIT BITE PROCEDURE REF. FIM 27-51 FAULT TREE 809 PERFORMED BITE ON THE FSEU AND FOUND MESSAGE NUMBER 27-81021 WITH FAULT MESSAGE (LE OUTBD ASYM). REF. THE TABLE A FIG 104A PERFORMED BITE TO ISOLATE THE PROXIMITY SWITCH CAUSING THE INDICATION REF FIM 32-09-00/101, FIG 103. AND FOUND SENSOR S286 REF. SLAT #5 DAMAGED. NECESSARY REPLACE LEADING EDGE SLAT SENSOR SWITCH REF. AMM TASK 27-88-01-902-001. REPLACED LEADING EDGE SLAT SENSOR SWITCH OF THE POSITION S286 AND PERFORMED BITE OF THE PSEU SENSOR TARGET TO EXAMINE THE SENSOR SWITCH OPERATION REF. FIM 32-09 FAULT TREE 803 AND NOT FOUND FAULT. ACCOMPLISHED LEADING EDGE SLAT SWITCH INSTHE PANELS FIN 621BB, 621EB, 621JB, 621TB, 621ZB AND 621AFB OF THE LEADING EDGE SLAT SENSOR SWITCH WERE INSTALLED AS PER TASK 57-41-01-400-801 ITEM OK.
DURING THE ACCOMPLISHEMENT OF EA 5300-01600-004, IT WAS FOUND A CRACK ON THE FORWARD OUTER CHORD INSIDE THE HORIZONTAL ACCESS PANEL. CHORD, RH PERMANENT REPAIR. THE PERMANENT REPAIR OF RH CHORD WAS ACCOMPLISHED AT TASK 76-0553-8-0153 AS PER EA5300-01600, OP 05 STA 1809 BHD OUTER
DURING REMOVAL OF STATIC DISCHARGER BASE ON THE RUDDER WAS FOUND UNDER THE BASE FOUR HOLES OUT OF STANDARD ON LH SIDE AND ONE RH SIDE THE RUDDER UPPER PANEL SKIN STATIC DISCHARGER WAS REPAIRED AS PER EC/RA: 5540-01602. ITEM OK TO SERVICE. ALL APPLICABLE INSPECTION STEPS REQUESTED PER EC/RA 5540-01602 WERE ACCOMPLISHED.
RII INSPECTION REQUIRED DURING DVI OF STRUT #2 FIRE SEAL AND FIREWALL - TOP SURFACE INSPECTION WAS OBSERVED CRACK ON NACELLE STRUT FWD UPPER SURFACE. ACCOMPLISHED ALL EC/RA# 5451-01467 STEPS.
THERE ARE CORROSION POINTS ON THE BEAM LOCATED AT STA287 BETWEEN LBL 45.0 AND LBL 50.0 OF MAIN DECK FLOOR STRUCTURE. FOR REFERENCE SEE B767 SRM 53-10-51-0I-1 FIGURE 1 DETAIL I ITEM 20. (ORIGINATING DOCUMENT NR 2426011) AS COVERED IN NR 2426011 ALL STEPS OF EC/RA: #5310-08509 WERE ACCOMPLISHED WITHOUT DEVIATIONS.
DURING REMOVAL OF SHEAR TIE WAS FOUND OLD EXTERNAL DOUBLER SKIN WITH CORROSION AT STA 1540 AND BETWEEN STGR 39 LH AND 39RH (ORIGINATING DOCUMENT NR 2422715). ERMANENT SOLUTION WITH INSPECTION REQUIREMENTS THAT MUST BE ACCO 0 ON OR BEFORE THE AIRCRAFT REACHES 27,732 TOTAL FLIGHT CYCLES. 0 FLIGHT CYCLES. MPLISHED AS PER PART 2 OF THE LATEST REVISION OF EC/RA 5360-0192 ACCOMPLISH REPEATED INSPECTIONS AT INTERVALS NOT TO EXCEED 12,00 FUSELAGE SKIN BETWEEN STA 1540 AND STA 1562 & S-39L AND S-39R AT THE DRAIN HOLE LOCATION WAS REPAIRED ATGIG. THIS REPAIR IS A P
IT WAS FOUND A CRACK INDICATION AT FORWARD ENTRY DOOR CUTOUT AFT LOWER CORNER AFTER NDT INSPECION PART 6 51-00-16 REV 139. (ORIGINATING DOCUMENT NR2396712)
FWD SERVICE DOOR AFTER CUTOUT - IT WAS FOUND A SKIN AND BEARSTRAP CRACK INDICATION IN THE MARKED HOLE AT 1 AND 7 ON''CLOCK POSITION. ( ORIGINATING DOCUMENT NR 2395993)
SMELL OF ELECTRICAL SMOKE SMELLED IN ROW 42 PER CREW LIGHT IN THAT AREA FLICKERED FOR A MOMENT DURING EVENT OF SMELL REF L/P 9364747. DURING AND AFTER HIGH POWER ENGINE RUNS NO ELECTRIC SMELL OR FLICKERING LIGHTS NOTICED.CONDITIONAL INSPECTION REQUIRED BY TOMC AS PER AMM 05-51-56. PERFORMED INSPECTION REF 05-51-56-940-801-C1. FLIGHT DECK-C-1 A,B,C. NO EVIDENCE OF BURNING NOR ARCING. PERFORMED INSPECTION REF MM 05-51-56-940-801-C1. STEPS C (2)-(3) NO DEFECTS NOTED PERFORMED INSPECTION REF MM 05-51-56-940-801-C1. STEPS C (4)-(5)-(6). NO DEFECTS NOTED PERFORMED STEP C (7) INSPECTED APU EXTERNAL AIR INLET, WITH FLASHLIGHT AND MIRROR, INSPECTED FOR EVIDENCE OF OIL LEAKS. NO LEAKS NOTED PERFORMED INSPECTION REF MM 05-51-56-940-801-C1. APU EXAUST-D-4. OPERATIONAL CHECK NORMAL REF MM 49-11-00-802-002. NO SMOKE NOTED. OPERATIONAL CHECKS REF MM 05-51-56-940-801-C1. COMPLY WITH STEP D-5-6-7-8. PERFORMED INSPECTION REF MM 05-51-56-940-801-C1 STEPS D(1)A,B,C. PERFORMED INSPECTION REF MM 05-51-56-940-801-C1 STEPS D (2) (A,B,C,D) NO DEFECTS NOTED. PERFORMED INSPECTION REF05-51-56-940-801-C1 STEPS D (3)(A,B,C,D,E,F,G,H) NO DEFECTS NOTED. COMPLIED WITH INSPECTION REF05-51-56-940-801-C1 STEPS D (8 THRU 21A). NO DEFECTS NOTED AND NO SOURCE FOUND AT THIS POINT. ADD EMP:U188290 PER AMM 05-51-56-940-801-C1 PARA 1.6.A. STEPS E AND F DO NOT NEED TO BE ACCOMPLISHED UNLESS REQUESTED BY TOMC. "PER TOMC SHIFT MANAGER NO FURTHER ACTION IS REQUIRED. NO FUTHER ACTION REQUIRED AS PER PREVIOUS UPDATE.
DURING REMOVAL OF LH OVERWING ESCAPE HATCH REF LOGPAGE 8707327, ESCAPE HATCH DOOR HITS LH CABIN CLASS DIVIDER FRAME PREVENTING CORRECT OPERATION OF EMERGENCY EXIT DOOR. CABIN CLASS DIVIDER ADJUSTED FORWARD ON SERATED PLATE AND CONFIRMATION OF ECAPE HATCH DOOR CLEARANCE TO DIVIDER CONFIRMED.
PAX AT SEAT 5A DROPPED 13IN MACBOOK AIR INTO SIDEWALL. UNABLE TO RETREIVE OPENED LWR DECK LH SIDE WALL PANEL AT DRIVE BAY D. RETRIEVED 13 INCH MAC BOOK AS DESCRIBED AND GIVEN TO PILOT. INSPECTED AREA BEHIND DRIVE BAY ''D'' LH SIDE WALL PANEL - NO DAMAGE OR IRREGULARITIES FOUND. PERFORMED CLOSE UP INSPECTION AND RESECURED DRIVE BAY ''D'' SIDE WALL PANEL IAW AMM 25-52-01 REV 141. FWD CARGO BAY GOOD FOR USE.
IDT INSPECTION REQUIRED. EMERGENCY PATH LIGHT ASSY REPLACEMENT. EMERGENCY PATH LIGHT REPLACED SEE LOGPAGE: 7475861. IDT INSP REQUIRED. EMERGENCY LIGHT AT 228FR RT SIDE OF FRONT GALLEY INSPECTED REF AMM 33-51-10-962-173 AND SWPM SECTION 20-83. ALL FOUND SATISFACTORY.
EMERGENCY LIGHTS OPERATIONAL CHECK {B767-33-3-7000} - GALLEY 2A COMPARTMANT 228F/R EEL LIGHT INOP. RELAMPED THE EEL NIL HELP. EEL ASSY. SUSPECTED. PARTS ORDERED. EEL ASSEMBLY REPLACED IAW AMM: 33-51-10-962-173 AND SWPM: SECTION 20-83. LIGHT TESTED AND CONFIRMED FUNCTIONS NORMALLY. 75-2530-3-0336,QTY :1
RIGHT MAIN LANDING GEAR DID NOT RETRACT AFTER TAKEOFF UPON ARRIVAL FIND OUT A MAJOR HYDRAULIC LEACK ON RIGHT MLG SUSPECTED TWO RIGID LINES SEE PICTURES FOUND RETRACT SYS HYDRAULIC HOSE LEAKING ABOVE R MLG, UNDER THE RETRACT ACTUATOR. REF IPC 32-32-54-05 ITEM 152. REMOVED AND REPLACED DAMAGED HYDRAULIC HOSE PER AMM 32-11-01/401. CYCLED GEAR HANDLE MULTIPLE TIMES WITH NO LEAKS NOTED. PERFORMED GEAR SWING PER AMM 32-32-00-735- 020 SEVERAL TIMES. GEAR OPERATION AND INDICATIONS WERE ALL NORMAL NO LEAKS NOTED AT THIS TIME.
LIGHTNING STRIKE ON EXTERIOR SKIN LOCASTED APPROX. STA 654+121 STR 34R. 53-00-01-2R-29 REPAIR 29. REPAIRED LIGHTNING STRIKE ON EXTERIOR SKIN AT STA 654+121 STR 34R PER B767-300 SRM RII INSPECTION FOR MJR-RII-SDR EXTERNAL FUSELAGE SKIN DOUBLER REPAIR ACCOMPLISHED PER SRM 53-00-01-2R-29, REPAIR 29 ON NON ROUTINE 167820-0100-0025.
#1 ENGINE PYLON I/B AND O/B SIDE HAS 2 EA. PANEL ATTACH STRAPS CRACKED ON AFT PYLON FRAME STA 410.
FIXED LE BRACE SUPPORT AT WS 530 CRACKED. REPLACED FIXED LE BRACE SUPPORT AT WS 530 IAW B767-300 SRM 51-40 -02.
FO CDU BLANK. CDU FUNC NORMAL UNTIL CRUISE THEN FLICKERED AND BL ANKED REF LOGPAGE 6732059 FOR LOGPAGE SIGNOFF.**CHRONIC LVL-0**DUE TO RECENT HISTORY OF FIRST OFFICERS CDU NOT RESPONDING OR FLICKERING ACCOMPISH THE FOLLOWING: 1) FIM 34-61 TREE 843, REPAIR AND REPORT ALL FAULTS. 2) IF NO FAULTS FOUND REPLACE THE FIRST OFFICERS CDU IAW AMM 34-61-02/401. THANKS! ORDLM GABRIEL TECH SUPP:FLT CREW STATED F/O CDU WAS STEADILY ON AFTER ENGINES WERE OFF.REF WD36-61-21-1A,PLEASE REMOVE CDU AND CHECK AT D467P PIN 40/41 FOR VAC,41 TO GND,36 TO GND,34 TO GND.CHECK CONNECTOR CONTACTS FOR INTEGRITY.THANKS CARRIED BY ELB PANEL, MCDU, ET OFF 19-3461-9-0006 3262 ON 0000 PANEL, MCDU, ET OFF 19-3461-9-0006 3262 ON 19-3461-9-0006 1593 PERFORMED FIM 34-61-843 NO DEFECTS WHERE NOTED ALSO SHOT PINS 40/41 FOR VAC AND PINS 41,36,AND 34 TO GND FOR INTEGRITY CHECK CHECK GOOD NO DEFECTS NOTED AT THIS TIME R&R FO CDU REF AMM 34-61-02-400-802 OPS CHECK GOOD NO DEFECTS NOTED AT THIS TIME. FOCDU REPLACED AS PRECAUTIONARY REQUESTED BY TECH SUPPORT FUP CLEARED PARTS USED: 19-3461-9-0006,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1544614 SN OFF 3262.
R ENG HPSOV EICAS ON T/O ROLL WITH ASSOC BLEED LIGHT. BLEED LIGHT DID NOT EXTINGUISH. V347 FAILED INTERNAL ELECTRICAL CHECK PER WDM 36-11-62, NEEDS NEW VALVE, REF AHM LP 5113215. REF AMM#36-11-18 REMOVED AND REPLACED HPSOV. LEAK AND OPS CHECKS GOOD WITH NO FURTHER MESSAGES NOTED. PARTS USED: 1728403,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1728403 SN OFF 0441 IPC REFERENCE # 36-11-01-50 VALVE, SHUTOFF, OFF 76-3611-9-0001 0441 ON 76-3611-9-0001 2142
TAT PROBE EICAS MSG AFTER LIFT OFF. RAN QRH AND RETURED TO EWR. FLIGHT CREW STATES L TAT PROBE C/B TRIPPED WITH ASSOCIATED EICAS MSG. RESET C/B AND PERFORMED TAT PROBE HEAT SYSTEM OPERATIONAL TEST REF AMM 30-33-00-715-710. TEST PASSED SEVERAL TIMES WITH NO FAULTS. OK FOR SERVICE. LEFT TAT PROBE HEATER BREAKER ON P6 PANEL WAS RESET.
SEVERAL EMERGENCY LIGHT INOP THROUGH OUT THE CABIN AREA. (REF AAR NR 9669188) REMOVED AND REPLACED BATTERY PACK POS M732 AS PER B737 AMM 33-51-02. PERFORMED OPS CHECK AND FOUND NORMAL ASSOCIATED EMERGENCY LIGHTS.
EMERGENCY ESCAPE SYS R FAILED TEST ON P 61.( EMERGENCY BATT. PACKS M962 (DISCHARGED) (REF AAR NR 9669192) REMOVED, REPLACED AND TESTED NORMAL M962 BATTERY FOR EMERGENCY ESCAPE RIGHT SIDE, PUSH TO TEST TESTED NORMAL REF B767 AMM 25-65-17-004-001-001, 25-65-17-404-008-001 AND STEP 3 G (11) OF 25-65-00-442-010.
EMERGENCY ESCAPE SYS L FAILED TEST ON P 61.( EMERGENCY BATT. PACKS M 961 (DISCHARGED) (REF AAR NR 9669191) REMOVED, REPLACED AND TESTED NORMAL M961 BATTERY FOR LEFT EMERGENCY ESCAPE, PUSH TO TEST TESTED NORMAL REF B767 AMM 25-65-17-004-001-001, 25-65-17-404-008-001 AND STEP 3 G (11) OF 25-65-00-442-010.
ROWS 21-23 AISLE EMERGENCY FLOOR LEVEL LIGHTING AND L+R OVERWING EXIT SIGNS AND RIGHT AISLE OVERHEAD EXIT SIGNS REMAIN ILLUMINATED WHEN AIRCRAFT IS DOWN POWERED WITH P5 EMERGENCY LIGHT SWITCH IN THE "OFF" POSITION. AIRCRAFT COMPLETELY DOWN POWERED WITH EXTERNAL POWER REMOVED AND STILL REMAINS ILLUMINATED. SUSPECT M1209 BATTERY/CHARGER. FOR INFO. SDR RAISED.
PER CREW AT 7000'' RIGHT DUCT LEAK LIGHT CAME ON WITH RIGHT BLEED DUCT LEAK EICAS MESSAGE. AT 14,000'' DUMPED 10,000 LBS FUEL. RAN CHECKLIST NO FIX. LANDED ROUGHLY 20,000 LBS OVERWEIGHT. ON P11 OPENED BUT REAPPEARS WHEN CLOSED. RAN FIM 26-18 FAULT TREE 804 BLOCK 1-8 "R BLD DUCT LEAK" EICAS MESSAGE AND RT DUCT LEAK LIGHT REMAIN ON. REPLACED AND REINSTALLED ORIGINAL DUCT LEAK CIRCUIT CARD (M691) FIRELOOP CONNECTOR NEEDS SAFETYING AND COVER PANEL IN RT REFERENCE LP 8765540 FOR OVERWEIGHT LANDING. REF WDM26-18-21-1 FOUND ELEMENT TS214 SHORTED. NEEDS REPLACEMENT SECURED FIRE LOOP CONNECTORS IN RIGHT WHEEL WELL AND SECURED IN P54, REPLACED K693 RELAY IN P37 AND CHECKED RESISTANCE ON RT WHEELWELL CEILING REINSTALLED. M&E 76-2618-3-0002 COVER PANEL REF L/P 8765683. WHEELWELL FIRELOOP READ 1.1 OHMS. NO OBVIOUS DUCT DAMAGE IN WING ROTABLE PARTS CHANGE WAS INDICATED - TT # 1179464 SN OFF 5279 LEADING EDGE OR WING ROOT NOTED. MESSAGE DISAPPEARS WHEN CB B10 ADD EMP:138125 IPC REFERENCE # CARD, ASSY, DUC OFF 64-2618-9-9001 7981 ON 64-2618-9-9001 1053 REPLACED #2 PYLON FIRELOOP TS214 REF AMM 26-11-02-424-033. NO CLOSE UP. EICAS FAULTS, NO #2 DUCT LEAK INDICATOR LAMP. PERFORMED INSTALLATION TEST, TESTS GOOD. DUE TO ITEM WAS A HARD FAULT, NO ENGINE RUN DETERMINATION WAS MADE. SEE L/P 8768314 ASSOCIATED
2 LOUD BANGS FOLLOWED BY RIGHT ENG POWER LOSS - PWR CAME BACK W/IN 10 SECS AT 10000 FEET. R ENG SURGE DET MESSAGE SEE PICTURES FOR INFO. RT ENG PIMU BITE REVEALED NO RELATED OR ASSOCIATED MESSAGES AS T CONTINUING WITH FIM-71-05/803 BLOCK 2 THRU BLOCK 6, VISUALS ACP''D HPC BLADES BORESCOPE FROM STAGE 10 AND UP TO STAGE 11, O POSSIBLE CAUSE OF STALLS OR SURGE AS STATED IN BLOCK 1 OF FIM CHECK GOOD & N1 TURN FREELY BOTH DIRECTIONS. INLET/TAIL NO FOUND MOST BLADES ARE DAMAGED AND TORN. CONDITION IS BEYOND FLY 71-05/803. VISUAL CHECKS PER FIM IN PROGRESS INCL BORO PREP OPEN DAMAGE AND 2.5 / 2.9 BLEED VALVE OPENINGS CLEAN..... BOROSCOPE BACK LIMITS, REF AMM 72-00-00-206-001-N01. VIDEO UPLOADED ON RVI ING PER BLOCK 7. UPDATE TO FOLLOW SITES. ENG SN 727948 REPLACED.ACCOMPLISHED #2 ENGINE RUNUP TEST #3, #6, AND #15 PER AMM 71-00-00/501 OPS CHECK GOOD NO LEAKS NOTED.
RIGHT INBOARD TRAILING EDGE FLAT HAS NUMEROUS DENTS DUE TO HAIL SHOULD READ TRAILING EDGE FLAP. REF SRM 57-53-01-1A-1 LOCKED FOR FERRY FLIGHT - ESC EVALUATED ALLOWABLE DAMAGED. UNLOCKED TO CLEAR LOGPAGE REFER FORM44-0008 ITEM1-32 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V926591, AND INSPECTED BY V898550 RIGHT INBOARD TRAILING EDGE FLAT PERFORMED REPAIR AS PER RI-57-00-15243 REV A AND ECRA5753-01988. ADD EMP:V898550
B767-53-3-7154 AFT CARGO COMPT - FLOOR SUPPORT BEAM BOTTOM SIDE 5EA ANCHOR NUT AREA CORROSION FOUND STA1153 BTN RBL9" TO LBL36" AS MARKED. TRANSFER REF. NON - ROUTINE ZHF510485 AND ORIGINATED BY EMP V896820 AFT CARGO COMPT STA1153 FLOOR BEAM UPPER CHORD REPLACED AS PER SRM51-10-02, ATTACH FORM 44-0008 ITEM1-23 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V897467 INSPECTED BY V912779 ADD EMP:V912779 RII ACCOMPLISHED BY V898550, SC NG, HX169509
B767-53-3-7154 AFT CARGO COMPT - FLOOR SUPPORT BEAM BOTTOM SIDE 5EA ANCHOR NUT AREA CORROSION FOUND STA1153 BTN RBL9" TO LBL36" AS MARKED. TRANSFER REF. NON - ROUTINE ZHF510485 AND ORIGINATED BY EMP V896820 AFT CARGO COMPT STA1153 FLOOR BEAM UPPER CHORD REPLACED AS PER SRM51-10-02, ATTACH FORM 44-0008 ITEM1-23 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V897467 INSPECTED BY V912779 ADD EMP:V912779 RII ACCOMPLISHED BY V898550, SC NG, HX169509
B767-53-3-7154 AFT CARGO COMPT - FLOOR BEAM BOTTOM SIDE SEVERAL ANCHOR NUT AREA CORROSION FOUND AT STA1329 BTN RBL16"-RBL29" AS MARKED. TRANSFER REF. NON - ROUTINE ZHF513877 AND ORIGINATED BY EMP V896820 AFT CARGO COMPT STA1329 BETWEEN LBL43 AND RBL43 FLOOR BEAM UPPER CHORD REPLACED AS PER SRM51-10-02 AND INSTALLED AS PER SRM51-40-02. ATTACHED FORM 44-0008 ITEM1-28 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V897467, AND INSPECTED BY V912779 ADD EMP:V912779 RII ACCOMPLISHED BY V896825, CM LUI, HX146276
SUPPORT TASK - BULK CARGO DOOR OUTER SKIN AFT EDGE PREVIOUS REPAIR DOUBLER HAS DENT. TRANSFER REF. NON - ROUTINE ZHF517134 AND ORIGINATED BY EMP V896888 RII INSPECTED BY HX169509 ADD EMP:V898550 BULK CARGO DOOR OUTER SKIN INTERIM REPAIRED AS PER ECRA 5236-01027. ATTACHED FORM 44-008 ITEM 1 TO ITEM 31 ACCOMPLISHED (ECRA 5236-01027 PART 1A). DOUBLER LOCATED AFT EDGE MIDWAY UP ADD EMP:V906762 REACHING 30,000 TOTAL DR FLIGHT CYCLE. REPEAT THE INSP AT P/N: 146T6301-3 S/N: 000516 IS AN ORIGINAL DR. TOTAL ACFT CYCLE INTERVAL NOT TO EXCEED 3,000 DOOR CYCLES THEREAFTER "NOTE: DR EQUALS TO TOTAL DOOR FLIGHT CYCLE" REF EC 5236-01027 PART 1.B - ACCOMPLISH INSP OF REPAIR INSTALLED ON BULK CARGO DR PER LATEST REV OF EC 5236-01027 PT 2, BEFORE ALL WORK DOCUMENTED ON HAECO NRC ZHF517134 WITH ATTACHED 44-0008, V906762, QC HX169509 REF ECRA 5236-01027, ACCOMPLISH INSP OF RPR INSTALLED ON BULK TOMC-APPROVAL FROM SC1ELBYC COMMENT CARGO DOOR PER PART 2, BEFORE REACHING 30,000 TOTAL DOOR FLIGHT CYCLE. REPEAT THE INSPECTION AT INTERVAL NOT EXCEED 3,000 DOOR CYCLES, THEREAFTER"NOTE: DOOR P/N: 146T6301-3 S/N: 000516 IS AN ORIGINAL DOOR. TOTAL AIRCRAFT CYCLE EQUALS TO TOTAL DOOR FLIGHT CYCLE QC QC REVIEWED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.
B767-53-3-7025 FWD CARGO COMPT - FLOOR BEAM UPPER SURFACE CORROSION CRACK AT STA632 BTN LBL30"-LBL32" AS MARKED. TRANSFER REF. NON - ROUTINE ZHF516482 AND ORIGINATED BY EMP V896820 FWD CARGO COMPT STA 632 BETWEEN LBL 43 AND RBL 43 FLOOR BEAM UPPER CHORD REPLACED AS PER SRM 51-10-02. WORK ACCOMPLISHED BY V897532 AND INSPECTED BY V912779 ADD EMP:V912779 RII ACCOMPLISHED BY V898550 SC NG, HX 169509.
B767-53-3-7056 BULK CARGO COMPT - BELOW FLOOR SHEAR TIE CORROSION FOUND AT STA1540 S37R-S38R AS MARKED TRANSFER REF. NON - ROUTINE ZHF512861 AND ORIGINATED BY EMP V896820 BULK CARGO COMPT STA1540 BETWEEN STR37R AND 38R SHEAR TIE REPLACED AS PER SRM51-10-02 ATTACHED FORM 44-0008 ITEM1-11 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V926514 AND INSPECTED BY V912779 ADD EMP:V912779
B767-53-3-7025 FWD CARGO COMPT - FLOOR BEAM UPPER SURFACE CORROSION CRACK AT STA632 BTN LBL30"-LBL32" AS MARKED. FWD CARGO COMPT STA 632 BETWEEN LBL 43 AND RBL 43 FLOOR BEAM UPPER CHORD REPLACED AS PER SRM 51-10-02.
B767-53-3-7154 AFT CARGO COMPT - FLOOR BEAM BOTTOM SIDE SEVERAL ANCHOR NUT AREA CORROSION FOUND AT STA1329 BTN RBL16"-RBL29" AS MARKED. TRANSFER REF. NON - ROUTINE ZHF513877 AND AFT CARGO COMPT STA1329 BETWEEN LBL43 AND RBL43 FLOOR BEAM UPPER CHORD REPLACED AS PER SRM51-10-02 AND INSTALLED AS PER SRM51-40-02. ATTACHED FORM 44-0008 ITEM1-28 ACCOMPLISHED.
B767-53-3-7077 CABIN - S16L - S17L JOINT BRACKET FOUND CORRODED. TRANSFER REF. NON - ROUTINE LP9130782 AND ORIGINATED BY EMP V923418 CABIN BS977 BETWEEN STR16L AND STR17L SHEAR TIE REPLACED AS PER SRM51-10-02 AND INSTALLED AS PER SRM51-40-02, ATTACH FORM 44-0008 ITEM1 TO ITEM8 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V897381, AND INSPECTED BY V896920 ADD EMP:V896920
B767-53-3-7077 CABIN - LH STA999 S-16L TO S-17L SHEAR TIE FOUND CORRODED. TRANSFER REF. NON - ROUTINE LP9130759 AND ORIGINATED BY EMP V926653 CABIN BS999 BETWEEN STR16L AND STR17L SHEAR TIE REPLACED AS PER SRM51-10-02 AND INSTALLED AS PER SRM51-40-02, ATTACH FORM 44-0008 ITEM1 TO ITEM8 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V897381, AND INSPECTED BY V896920 ADD EMP:V896920
B767-53-3-7077 CABIN - S16L - S17L JOINT BRACKET FOUND CORRODED. TRANSFER REF. NON - ROUTINE LP9130782 AND ORIGINATED BY EMP V923418 CABIN BS977 BETWEEN STR16L AND STR17L SHEAR TIE REPLACED AS PER SRM51-10-02 AND INSTALLED AS PER SRM51-40-02, ATTACH FORM 44-0008 ITEM1 TO ITEM8 ACCOMPLISHED. WORK ACCOMPLISHED BY MECHANIC V897381, AND INSPECTED BY V896920 ADD EMP:V896920
B767-53-3-7056 BULK CARGO COMPT - BELOW FLOOR SHEAR TIE CORROSION FOUND AT STA1540 S37R-S38R AS MARKED TRANSFER REF. NON - ROUTINE ZHF512861 AND ORIGINATED BY EMP V896820
EA5300-01606 REV A OP 001 NOSE WHEEL WELL BULKHEAD LH VERTICAL CHORD ABOVE WL159 FOUND 1EA CRACK AS MARKED TRANSFER REF. NON - ROUTINE LP9130522 AND ORIGINATED BY EMP V914372 LH NOSE WHEEL WELL VERTICAL STIFFENER ON STA287 BETWEEN WL159 INSPECTED BY V896888 AND WL185 REPAIRED AS PER EA5300-01606 REV A OP 003 REFER SEQ NO.2303 FOR WORK DETAIL. WORK ACCOMPLISHED BY MECHANIC V897381 ADD EMP:V896888
EA5300-01606 REV A OP 001 NOSE WHEEL WELL BULKHEAD LH VERTICAL CHORD ABOVE WL159 FOUND 1EA CRACK AS MARKED TRANSFER REF. NON - ROUTINE LP9130522 AND ORIGINATED BY EMP V914372 LH NOSE WHEEL WELL VERTICAL STIFFENER ON STA287 BETWEEN WL159 INSPECTED BY V896888 AND WL185 REPAIRED AS PER EA5300-01606 REV A OP 003 REFER SEQ NO.2303 FOR WORK DETAIL. WORK ACCOMPLISHED BY MECHANIC V897381 ADD EMP:V896888
CAPTAIN REPORTED STRANGE NOISE AND HE WAS UNSURE WHERE IT CAME FROM. TORUBLESHOOTING STARTED AND FOUND NOISE FROM THE MAIN WHEEL BAY. DOORS WERE OPENED AND FOUND BLACK MARKINGS AND HISSING NOISE FROM SUPPLY DUCT FROM THE APU TO THE A/C SYSTEM. FOUND BLEED AIR DUCT CRACKED 40% OF DIAMETER. DUCT REPLACED AND CRS ISSUED. OCCURRENCE REPORT MADE. AFTER DUCT REPLACEMENT NOISE WAS STILL PRESENT, FURTHER T/S CARRIED OUT AND IN CONSULT WITH THE MOC INOPED APU BLEED AIR. NEXT DAY, UNITED FOUND ANOTHER DEFXECT OF THE APU CASING WHICH CAUSED THE VIBRATION/NOISE, DEFECT SOLVED.
RUDDER RATIO EICAS ILLUMINATED MSG APPEARED AFTER GO AROUND ON MANCHESTER. IAW FIM 27-21 TASK 8 04 FLAG NO.5 THIS COULD BE A NUISANCE MESSAGE IN GUSTY WIND COND ITIONS. RESET MODULES. PERFORMED BITE IAW FIM 27-09-00-815-814 A ND TEST RUDDER RATION SYST IAW AMM 27-21-00-825-036-001. ALL SAT IS. DISCUSSED COMPLAINT WITH CONTROLLER GORMAN AND SENIOR MANAGER MC NEELY. THEY AGREED WITH THE MAINTENANCE ACTIONS.
12 O''CLOCK & 6 O''CLOCK CRACK FOUND AT R/W LOWER SKIN STR L-9.5 BETWEEN RIB 31 AND 30 MOST OUTBOARD OPEN FASTENER HOLE FABRICATED AND INSTALLED FRAME PLUGE REPAIR PER B767 DWG 767-9420 AND SRM 51-20-01
PERFORMED (BHEC) INSP AT L/W REPAIR/PREVENTATIVE MOD OF I/B SEGMENT STR L-9.5, CRACKS NOTED AT 3 OPEN FASTENER HOLES MARKED IN RED. FABRICATED AND INSTALLED FREEZE PLUG REPAIRS PER DWG 767-9420 & SRM 51-20-07 BY OUTSIDE VENDOR P.O# 1622069 AT L/WING ON EXTREME O/B AND I/B HOLES STR L-9.5
GEAR DISAGREE LIGHT AND ASSOCIATED EICAS WITH TAILSKID LIGHT, AND EICAS ON FINAL. EMERGENCY DECLARED. FOUND MESSAGE WOULD CLEAR WITH SLIGHT MOVEMENT OF GEAR HANDLE. R & R THE LANDING GEAR CONTROL LEVER MODULE IAW AMM32-31-01. ALL TESTS PASSED.
FWD GALLEY BS 217 FACING ON RIGHT SIDE LOWER EMERGENCY LIGHT COVER AND BULB BROKEN. REPLACED THE LIGHT ASSY. OPS OK.
EMER LIGHTS WILL NOT ARM. ADJUSTED GUARD ON EMERGENCY LIGHT SWITCH. OPS CK NORMAL.
ONE LT AFT FUSELAGE EMERGENCY LIGHT FWD OF L4 DOOR IS INOP. REMOVED AND REPLACED LT AFT FUSELAGE EMERGENCY LIGHT FWD OF L4 DOOR IAW AMM 33-51-06-902-082. OPS CHECK GOOD.
BULK CARGO DOOR EXTERNAL HANDLE HOUSING IS CHAFED ON THE INSIDE. REMOVED AND REPLACED THE CARGO DOOR HANDLE HOUSING IAW IAW SRM 51-40-02
AFT RIGHT LAVATORY HAS BURNING ODOR, PEFORMED EC/RA 0500-01055. PEFORMED DETAILED IN SPECTION AND OPERATIONAL CHECKS IAW ECRA. NO DEFECTS NOTED ON THE GROUND. OK TO CONTINUE SERVICE.
FLASHLIGHT INOPERATIVE. SEATED THE FLASHLIGHT IN THE CRADLE, OPS CHECKED NORMAL.
LT REVERSER ISOLATION VALVE EICAS THE LEFT THRUST REVERSER ISOLATION VALVE HAS A FAILURE. L REV ISLN VAL EICAS MSG ON LANDING. TR WOULD NOT DEPLOY. TS REF FIM 78-34-00-815-807 NOO. FOUND ISOLATION VALVE PLUG DIRTY. CLEANED PLUG. VERIFIED NO LTS ON TR RELAY MODULE. OPERATED TR THROUGH 10 CYCLES AND ALL INDICATIONS NORMAL. NO MSGS
EXT EMERG LIGHT SMALL LENS CRACKED LOC. LT JUST AFT OF IB FLAP T/E REPLACED LENS ASSY.
ELECTRICAL ODOR IN AFT GALLEY. REMOVED AND REPLACED THE RT CHILLER. OPS CHECKED GOOD IAW AMM 25-33-02.
DURING A CHK EMERGENCY LIGHT OPS CHK, FOUND WING RT SLIDE GND ILLUMINATING LIGHT L644 INOP. REF WIRING MANUAL 33-51-21. T/SHOT WIRING LIGHT FIXTURE, NO VOLTAGE. FOUND LIGHT L644 AND L392 BOTH INOP, FOUND NR 2 FUSE ON BATTERY PACK M733 OPEN. REPLACED FUSE, BOTH LIGHTS NOW OP CHECK GOOD.
1L LOWER EMER EXIT LIGHT IS FLICKERING ON AND OFF . EMER LIGHTS SWITCH IN THE ARMED POSITION. REMOVED AND REPLACED BATTERY POWER SUPPLY M1557 AWM 33-5-14 PG 2A OPS CHECK GOOD.
DOOR 1L EMERGENCY EXIT LIGHTS CAME ON 45 MINS INTO FLT STDY AT FIRST THEN FLICKERED. PRES NORMAL REMOVED UPPER L1 DOOR EMERGENCY EXIT LIGHT, INSPECTED CONNECTION WIRES WITH NO ISSUES NOTED. REPLACED UPPER L1 EXIT LIGHT ASSY REF AMM 33-51-01. OPS CHECK NORMAL.
L1 DOOR EMERGENCY EXIT LIGHT INTERMITTENT. LIGHT OPS CHECKS OK AND NORMAL
STATION 1140 RT TENSION TIE FRAME WEB, 2 EACH FASTNER HOLES CRACKED. STATION 1140 RT TENSION TIE FRAME WEB R & R IAW SRM 53-40-07 REPAIR 2 FIG 201 REV 94 & DWG 65B01570 REV C.
A VIBRATION WAS FELT FROM APPROX MID CABIN GOING AFT. THE RT ELEVATOR INDICATION ON THE LOWER EICAS PAGE WAS INDICATING A FLUTTERING OF ABOUT 1 INDICATOR WIDTH. NO VIBRATION WAS FELT IN THE COLUMN OR YOKE. THE CTR AP WAS ENGAGED & REMAINED ENGAGED. CHANGES IN AIRSPEED & ALTITUDE DID NOT SEEM TO CONSISTENTLY AFFECT THE FLUTTERING IND ON EICAS. WHILE ACCOMPLISHING AIRFRAME VIBRATION CONDITIONAL INSPECTION IAW AMM 05-51-38, FOUND LT MOST AFT WING TO BODY FAIRING FASTENERS LOOSE. SECURED, ACCOMPLISHED ELEVATOR OPERATIONAL CHECK IAW AMM 27-31-00. NO DISCREPANCIES NOTED.
2R WING SLIDE EMER LIGHT INOPERATIVE & AFT RT DOOR SLIDE EMER LIGHT INOPERATIVE. FOUND BATTERY & CHARGER FOR EMER LIGHT POWER SUPPLY INOPERATIVE M733 REFERENCE SSM 33-51-0 1. REPLACED BATTERY & CHARGER ASSEMBLY IAW AMM 33-51-07. OPERATIONS CHECKED GOOD.
SEAT MOUNTED EMER EXIT LIGHTS INOPERATIVE FROM SEAT ROWS 1 RT - 10 RT. FOUND BROKEN WIRES WDM 33- 51-12 BELOW & OTBD OF SEAT 1R W1222-902R, W1222-902 BLK REPAIRED & SPLICED IAW SWPM 20-30-12. LIGHTS OPERATE NORMAL.
GENERATED FOR FLIGHT CREW. AFTER TAKEOFF FLAPS 1 TO UP, EICAS LE SLAT ASYM FLAP INDICATOR STOPPED BETWEEN 1 & 0. ALT FLAP CHECKLIST USED. . S295 SENSOR REPLACEMENT NR 11 SLAT. PERFORMED TESTS IAW AMM 27-88-01. ALL TESTS PASSED AT THIS TIME. OK TO CONTINUE.
DOOR TEST LIGHT IN THE FLIGHT DECK WOULD NOT ILLUMINATE DURING TEST MODE. SECURED LT EMER LIGHT BATTERY PACK CONNECTOR. TESTED SYS OPERATIONS CHECKED NORMAL
LEFT AFT OVERWING EMER ESCAPE HATCH EXTERIOR AFT DOOR CABLE KINKED. REPLACED LT AFT OVERWING EMER ESCAPE HATCH, EXTERIOR AFT DOOR CABLE IAW MM 52-21-01.
LEFT, RIGHT & CENTER MID EMER LIGHT BARS INOPERATIVE. RECONNECTED FEEDER WIRES ON CTR, LT & MID EMER LIGHT BARS. R & R RT MID EMER LIGHT BAR IAW MM 33-51-10, OPERATIONS CHECKED GOOD IAW MM 33-51-10.
LEFT STATION 955 FAIL SAFE STRAP LOWER FASTENER HOLE HAS CRACK INDICATION. ACCOMPLISHED EA 5340-01478, REV A, OPS 03 AS REQUIRED ON JC COA-691845003.
AFT CARGO COMPARTMENT BILGE FLOORBEAM T CAP CORROSION UNDER NUTPLATE STATION 1197 PLUS 70 RB 40. REMOVED CORROSION BEYOND ALLOWABLE LIMITS. R & R IAW SRM 51-40-02 & DWG 146T1206. R & R ROLLER TRAY B1A & B6A IAW SRM 51040-02.
AFT CARGO COMPARTMENT BILGE FLOOR PAN BEAM AT STATION 1220 CORRODED AT SEVERAL NUTPLATES MARKED APPROXIMATELY 8. R & R FLOORBEAM J CHANNEL UPPER CHORD IAW 51-40-02 & DWG 146 1060.
AFT CARGO COMPARTMENT BILGE FLOORBEAM T CAP CORROSION UNDER NUTPLATES AT STATION 1197 - 114 RB 43 & LB 43. INSTALLED NEW CHORD IAW 51-40-02 & DWG 146T1060.
AFT CARGO COMPARTMENT BILGE FLOOR T CAP CORROSION UNDER NUTPLATE AT STATION 1200 RB43. R & R CHORD IAW SRM 51-40-02 & 51-40-05.
RIGHT MID LAVATORY MS4 EEL LIGHT STRIP HAS BROKEN WIRES. R & R RT MID LAVATORY EEL LIGHT STRIP IAW AMM 3 3-51-10, OPERATIONS CHECK GOOD.
CAP SMOKE GOGGLES & COVER SOILED WITH LIQUID. REPLACED GOGGLES & COVER OK TO CONTINUE.
FWD EQUIP COOLING EXHAUST FAN EICAS MESSAGE. ODOR SIMILAR TO ELECTRICAL ODOR WAS AFTER TAKE OFF & WHEN POWER RETARDED. ODOR WAS SHORT IN DURATION & DISSIPATED RAPIDLY WITH NO ACTION BY THE CREW OR FLIGHT ATTENDANTS. THE ODOR REMAINED GONE AFTER IT DISSIPATED, NO SMOKE OR FUMES WERE NOTED AT ANY TIME. NO EVIDENCE OF ODOR ON ARRIVAL. PERFORMED ALL REQUIRED CHECKS & PERFORMED HIGH POWER ENG RUN TO CONFIRM ALL ODORS HAVE BEEN CLEARED. AIRCRAFT OK FOR FLIGHT AS STATED IN PREVIOUS LOG ITEMS IAW AMM 05-51-35-201. R & R FWD EXHAUST COOLING FAN MONITOR IAW AMM 21-58-06. OPERATIONS NORMAL STATUS MESSAGE CLEARED.
ON ENG NR 1 ESN 717550 IAW EC6281, FOUND ONE EACH 2ND STAGE HPT BLADE DAMAGED. DAMAGE IS ON LE APPROXIMATELY 0.400 INCHES LONG BEGINNING 0.300 INCHES FROM THE END OF THE BLADE. THE DAMAGE IS ON BOTH THE CONVEX & CONCAVE SIDES & PARENT METAL IS MISSING WITH A HOLE COMPLETELY THRU TO THE COOLING AREA OF THE BLADE. DAMAGE IN AREA A & B WITHIN 5 CYCLE FLY BACK LIMITS FOR ENG CHANGE, REPLACED ENG IAW AMM SN OFF 717550 & SN ON 727916.
AT D41921 FWD PYLON NR 1 ENG HAS MULTIPLE GND WIRES BROKEN. REPAIRED WIRING SHIELD GNDS IAW SWP 20-10-15 & WDM 75-23-11, 78-36-11. SEE PTT 6182027, 6182028, 6182029, 6182040, 6182041, 6182042 & 6182043 FOR SPECIFIC DETAILS. IAW SMC053 FOR CANNON PLUG INSTALLATION & SEALING.
IAW SMC014 WIRE W356-149-20 SHIELD GND NEEDS REPAIR AT CONNECTOR D4192J. IAW WDM 78-36-11 REPAIRED SHIELD GND FOR WIRE W356-149-20 IAW SWP 20-10-15.
HEAT SHIELD, BLANKET ABOVE CNA DAMAGED. REPLACED HEAT SHIELD
IAW SMC014. WIRE W356-150-20 NEEDS SHIELD GND REPAIRED AT CONNECTOR D4192J, IAW WDM 78-36-11. REPAIRED SHIELD GND FOR WIRE W356-150-20 IAW SWP 20-10-15.
INBD C DUCT NR 1 ENG HAS FIRE BLANKET DISBOND IN 2 AREAS, LOWER IS APPROXIMATELY 30 X 24 INCHES, UPPER IS APPROXIMATELY 10 X 18 INCHES. REPAIRED AREA IAW SRM 78- 31-01.
NR 1 ENG INBD C DUCT COOLING AIR INLET NOT SEALANT MATING SURFACE. REPAIRED NR 1 ENG INBD C DUCT COOLING AIR INLET MATING SURFACE.
INLET COWL ON NR 1 ENG INLET TIA TUBE HAS MULTIPLE DENTS & GOUGES FROM 3 O'CLOCK TO 6 O'CLOCK AFT FACING FWD. REVIEW OF CMM 36-10-06 PAGE 603 & 604 SHOWS FINDINGS OUT OF LIMITS. REPAIRED DUCT IAW CMM 36-10-06 REP 1-1.
ON ENG NR 1 RT CORE COWL UPPER TE CORNER, PREVIOUS REPAIR IS DAMAGED. REINSTALLED MISSING FILLER MATERIAL 071 2024 & REINSTALLED FASTENERS IAW SRM 51-40-02. IAW NON RII INSP OF REPAIR TO INBD TE CORE COWL NR 1 ENG. REPAIR IS COMPLETE IAW SRM 51-40-02.
HAVE APU FUEL VLV EICAS & APU FAULT LIGHT. R & R APU FUEL SOV.
RT GEN OFF LIGHT ILLUMINATED ON DESCENT. RAN CHECKLIST RESET, DID NOT RESET. BPCU READOUT FOUND SHORTED PMG TRIP & GEN FIELD WIRING GCU. AFTER RESET PB BPCU TESTED OK. AFTER RT ENG RUN GEN OFF AGAIN. AIRCRAFT RELEASED IAW MEL.
LT & RT DUCT PRESSURE SPLIT DURING CRUISE, WITH ENGINES RUNNING. LT & RT ISOLATION VALVES CLOSED & BLEED SWITCH ON. LT PRESSURE 35 PSI & RT PRESSURE 20 PSI, CRUISE FL 370 LEPR 1.17 REPAIR 1.22. PERFORMED AIR SUPPLY DISTRIBUTION SYSTEM TEST PER AMM 36-11-00-501. BLEED PRESSURES AND BLEED SHIFT POINTS NORMAL. SYSTEM TEST ACCOMPLISHED.
CTR FCC PROBLEM, RTFL UNABLE TO ENGAGE CENTER OR RT AUTO PILOT NO EICAS MESSAGE. TROUBLE SHOT IAW FIM 22-00-02, PREV FLIGHT FAULT, NO INFC FCC C MCDP SHOWN. REPLACED FCC CENTER IAW MM. MCDP GROUND TEST 1 & TEST 56 PASSED.
NR 2 WINDOW ASSEMBLY6 AIR LEAKS POSITION 2 2=2L, 5=2R. AIR LEAK AT BOTTOM OF WINDOW, NOT SQEAL, LEAK. MOVING CRANK STOPS LEAK, RELEASING RESUMES. PERFORMED NR 2 POSITION 2 WINDOW ADJUSTMENT TEST IAW AMM 56-11-02-501. PRESSURIZATION LEAK CHECKED GOOD, & WINDOW HEAT OPERATIONAL CHECKED GOOD IAW AMM 05-51-24-201.
HEADING SELECT KNOB FALLING APART. HEADING SELECT INOPERATIVE. MODE CONTROL PANEL REPLACED IAW AMM 22-11-02, MCDP TEST 04 CARRIED OUT, ALL SATISFACTORY.
HDG SELECT BINDS WITH BANK LIMIT. MODE CONTROL PANEL SECTOR BANK LIMIT SELECTOR INOPERATIVE. REPLACED MODE CONTROL PANEL IAW MM. TEST CHECKED GOOD.
RIGHT PACK COMPRESSOR OUTLET DUCT SPLIT AT COMP OUTLET TEMP SENSOR BOSS. REPLACED DUCT ASSY, LEAK CHECKED AND TESTED IAW MM 21-51-00 PG 501 ALL GOOD. REPLACED ELBOW FITTING & ACCOMPLISHED PACK TEST WRT MM. ALL INDICATIONS CHECKED OK. ALSO LEAK CHECK ACCOMPLISHED, NO LEAKS FOUND.
LEFT CENTER FUEL PUMP ON WITH ENGINES SHUTDOWN AT GATE.
LEFT FUEL PUMP LOW PRESSURE LIGHT DOES NOT COME ON. CLEANED AND INSPECTED LT CENTER FUEL PUMP PRESSURE SWITCH. ACCOMPLISHED FUEL PRESSURE INDICATING OPS CHECK.
HYDRAULIC FLUID DRIPPING FROM RT WING INBD OF RT ENGINE PYLON. REMOVED UNDER WING PANELS ON RT SIDE NEAR INBD CANOE. ACCOMPLISHED CHECK IAW MM 29-11-00. OPERATED ALL CONTROLS SPOILERS AND FLAPS NO LEAKS FOUND, QTY 0.95 & STEADY. ACCOMPLISHED STATIC LEAK CHECK, NO LEAK FOUND. FOUND FLUID COMING FROM #8 SPOILER PRESSURE LINE. REPLACED ORING UNDER UNION. LEAK CHECK GOOD. CLEANED AREA. OK TO CONTINUE.
HYD LEAK, RT WING JUST INBD OF INBD AILERON. FOUND DC MOTOR OPERATED SHUTOFF LATERAL CONTROL EMPENNAGE VALVE LEAKING. CYCLED LATERAL CONTROL VALVE, AND TIGHTENED PRESSURE LINE, NO LEAKS NOTED.
FOUND LEAK ON FLEX LINE BETWEEN STAB TRIM CONTROL MODULE AND STAB TRIM ACTUATOR. REPLACED LINE, LEAK CHECKED NORMAL.
LEFT HYDRAULIC SYS DOWN TO .85 ON ARRIVAL. NOTED HYD FLUID ON TAIL AREA OF ACCESS PANEL TO HORIZONTAL STABILIZER. SERVICED HYD SYS TO FULL. CLEANED TAIL AREA ENTERED ACCESS PANEL TO HORIZONTAL STABILIZER BAY FOUND LEFT AP ELEVATOR SERVO ACTUATOR ROD LEAKING TWO DROPS PER MINUTE, REF TABLE ONE 29-00-99 PG601. REPLACED LT AP SERVO IAW AMM 22-12-01. ADJUSTED, LEAK CHECKED AND TESTED GOOD.
SATCOM INTERMITTENT. CALLS TO DISPATCH DO NOT STAY CONNECTED. REPLACED SDU IAW AMM, GROUND CHECKS NORMAL.
NR 1 ENGINE INLET COWL DENTED. REPAIRED.
RIGHT ENGINE PYLON INBD AFT FAIRING HAS DELAMINATION. PERFORMED METAL BOND REPAIR PER AMM.
WHILE PERFORMING MF8840, FOUND ONE MISSING FASTENER ON NR 2 ENGINE OUTBD PYLON HEATSHIELD. REPAIRED.
NO COMM DISPLAYED ON ACARS DISPLAY UNIT OVER OCEAN, ACARS SENDS OK IN VHF RANGE. ACCOMPLISH CHRONIC REVIEW. PLACARD SATCOM DUE TO HISTORY PER 2325A, C-B'S COLLARED. REMOVED AND REPLACED SAT DATA UNIT IAW AMM. OPS CHECK GOOD REF 23-25-00. SEE 8262003 FOR PARTS INFO
UPPER EICAS FAILED. REMOVED AND REPLACED UPPER EICAS DU, OPS CHECK NORMAL.
CAPT PITOT LIGHT AND EICAS MESSAGE ON ENGINE START. REPEAT WRITE-UP. RELAY K241 PART N.770540- 2 AND K516 PART N. BACR13CG2A. REPLACED SPEED CARD TEST PERFORMED IAW AMM. PITOT HEAT TEST PERFORMED IAW AMM.
NO COMMS DISPLAYED ON ACARS DISPLAY UNIT, OVER OCEAN. ACARS SENDS OK IN VHF RANGE. REPLACED SDU PER AMM, GROUND CHECKED NORMAL.
FWD CARGO DOOR, CARGO HANDLING PANEL, BOTTOM LATCH BROKEN. DEF PER CDL. REMOVED DOOR AND STOWED IN FORWARD CLOSET IN CABIN. REPLACED LATCH AND SECURED ACCESS PANEL TO FWD CARGO CONTROL AREA.
DENT ON EXISTING DOUBLER REPAIR 2 INCHES BELOW STR 16L BS 768. MAJOR REPAIR ACCOMPLISHED. REMOVED EXTERNAL REPAIR DOUBLER 2 INCHES BELOW STR 16L AT BS 768 IAW B757-200 SRM 51-40-02 FIG 8. FABBED, LOCATED, AND DRILLED DOUBLER AND FILLER IAW B757- 200 SRM 53-00-01 FG 201 REPAIR 2. INSTALLED DOUBLER AND FILLER IAW B757-200 SRM 53-00-01 FIG 201 REPAIR 2.
LOCKING RING MISSING FROM BOTTOM PANEL OF COCKPIT DOOR. REPLACED LANYARD RINGS.
WEATHER RADAR TEST MODE DOES NOT TEST PROPERLY. TEST MODE CONTINUES TO DISPLAY AND, UNABLE TO DE-SELECT. REPLACED WEATHER RADAR CONTROL PANEL AS PER MM AND ACCOMPLISHED SYSTEM TEST AS PER MM.
COCKPIT TEMP EICAS. BITE CHECK AUX ZONE CONTROLLER, SHOWS CTR YEP CONTROL FAULT. FOUND CONNECTOR ON CTR AUX TEMP SELECTOR LOOSE. SECURED CONNECTOR, BITE CHECK ZONE CONTROLLERS, NO FAULTS. CLEARED EICAS MSG. SIGN OFF TEXT SHOULD STATE: SECURED CONNECTORS IN PROPER LOCATION.
NR 2 ENGINE THRUST REVERSER LEFT HALF HAS DELAMINATED FIRE SEAL INSULATION ON LOWER QUADRANT. RE-ADHERED FIRE SEAL INSULATION TO INNER THRUST REVERSER HALF ON LOWER QUADRANT. FIRE SEAL IS STILL IN PARTIAL CURE. ALL SEAMS MUST BE SEALED. THERE IS A PART OF THE SEAL THAT IS NOT ADHERING AND NEEDS TO BE RE-ADHERED AGAIN. IT IS IN THE UPPER FORWARD QUADRANT AREA AND NEEDS TO BE RESEALED. COMPLETED REPAIR.
RIGHT ENGINE EEC C1 STATUS MSG, RTFL. REPLACED NR 2 ENGINE EEC ALTERNATOR STATOR. RAN ENGINE, NO MESSAGES, INDICATIONS NORMAL.
RIGHT GENERATOR TRIPPED OFF-LINE JUST AFTER TAKEOFF. A/C POWER AVAILABLE FROM APU. FLIGHT CONTINUING TO MUC. TOMC PLANNING TO DEFER RIGHT ENGINE GENERATOR IN MUC. REPLACED APU GCU.
VOICE ON SATCOM NOT WORKING. ACARS CAN USE OK. MSG "LOW GAIN" ON LINE 6 OF CDU. REPLACED SATELLITE DATA UNIT PER MM. CALLED SAMC, OPS CHECKED NORMAL.
RIGHT GENERATOR OFF, RESET DID NOT WORK. REPLACED IDG PER MM. RAN ENGINE LOADED GENERATOR TO 71%. OPS CHECKED GOOD. RE-SERVICED IDG AND ACCOMPLISHED LEAK CHECK. NO LEAKS FOUND.
UNABLE TO OPEN AFT CARGO PIT DOOR EITHER MANUALLY OR ELECTRICALLY. REPLACED AFT DOOR LIFT LATCH POWER UNIT, OPS CHECK GOOD.
CREW REPORTS THEY HAVE A "R ENG EEC C1" STATUS MSG. TRIED TO CYCLE THE SYSTEM, ENGINE SHUTDOWN AND RESTART. MSG CLEARED WITH RESTART OK. TO DEFER PER MEL 7321H. BITE FAULT CH A N2 RANGE FAIL. REPLACED RIGHT ENG EEC REF MM 73-21-04 RAN ENG NO STATUS MESSAGE.
E+E DOOR, EXTERIOR SKIN FOUND TO HAVE MINOR PITTING. ORIGINAL MATERIAL THICKNESS IS .050", MATERIAL REMAINING AFTER BLENDOUT IS .039" RIGHT SIDE & .044" LEFT SIDE. FABRICATED AND INSTALLED 2 EACH REPAIR DOUBLERS PER SRM 52-40-01, REPAIR 5, ON NON ROUTINE 46891.
BS 303 RBL 54 TRANSVERSE FLOORBEAM UPPER CHORD CORRODED (TOP SIDE). MATERIAL REMAINING OUT OF LIMITS PER SRM 53-00-01 IN 5 AREAS BETWEEN RBL 37 TO RBL 63. REMOVED DAMAGED SECTION OF T-CHORD AND FABRICATED AND INSTALLED REPAIR ANGLES, STRAPS, SHIMS AND CLIPS PER SRM 53-00-51, RPR 4, ON NON ROUTINE 46845.
BS 1582 LAP SEAM APPEARS TO BE UNEVEN, ENTIRE CIRCUMFERENCE OF FUSELAGE, AFT PRESSURE BULKHEAD ATTACHMENT POINT. MAINT TEXT: ACCOMPLISHED ALL REQUIRED INSPECTIONS AND ACCOMPLISHED STRINGER SHIMMING REPAIRS AT THE FOLLOWING LOCATIONS: SECTION 46, STR'S 3R, 12R, 14R, 14L, 34L: AND SECTION 48, STR'S 3R, 6R, 12R, 14R, 24R, 29R, 31R, 33R, 39R, 12L, 14L, 19L, 24L, 32L, 34L, AND 39L PER REO G-15401, REV L AND EC-RA 5361-01028.
BS 1582, STRINGER END FITTING AT STRINGER 34 LEFT, SECTION 46 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED THE STRINGER 34 LEFT END FITTING, P/N 146T0307Y1 AND LOCATED AND DRILLED PER SRM AND INSTALLED PER SRM.
MJR RPR. LOWER EXTERNAL FUSELAGE SKIN TOOLING DAMAGE BETWEEN BS 1329-1351 AT STR 35L-36L. BLENDED OUT DAMAGE & FOUND MATL LOSS OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP HFEC REF NDT MAN 51-00-19. NO DEFECTS. FABRICATED & INSTALLED AN EXTERNAL DOUBLER & FILLER REPAIR REF SRM53-00-01 REPAIR 14.
EXTERIOR FUSELAGE LOWER SKIN LEFT SIDE DENTED, BS 610 - BS 632, STR 32L - STR 33L. EVALUATED DENT & FOUND CRACKED OUTER SKIN. CUT OUT DAMAGE & ACP NDT OF CUT-OUT REF NDT MAN 51-00-19. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLER REPAIR REF SRM 53-00-01.
UNDER PAINT TOOLING BLENDOUT AT STR 2 RIGHT NEXT TO THE TCAS ANTENNA. EVALUATED DAMAGE & FOUND MATERIAL LOSS OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP HFEC REF NDT MAN 51-00-19. NO CRACKS. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLERS REPAIR REF SRM 53-00-01 RPR 12.
UNDER PAINT TOOLING BLENDOUT AT STR 2 RIGHT NEXT TO THE TCAS ANTENNA. EVALUATED DAMAGE & FOUND MATERIAL LOSS OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP HFEC REF NDT MAN 51-00-19. NO CRACKS. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLERS REPAIR REF SRM 53-00-01 RPR 12.
BULK CARGO DOOR FWD LOWER CORNER HAS 6 EA DENTS 1" TO 5.5" FROM FWD EDGE, 1.5" TO 6.25" FROM BOTTOM EDGE. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 52-30-01, DET VI NOTE J. REPAIRED IAW SRM 52-30 -01, FIG 201. THIS REPAIR IS CATEGORY A.
AFT CARGO COMPARTMENT BILGE, SHEAR TIE CORRODED BS 1395 - 1396, STR 39L - 39R. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. FABRICATED & INSTALLED NEW SHEAR TIE IAW SRM 51-40-02.
AFT FUSELAGE LOWER INTERNAL BILGE AREA WEB TIES CORRODED AT SEVERAL AREAS BS 1540, STR 36R - STR 39R. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION ON SHEAR TIE STA 1540 BETWEEN STR 39R-38R, ARE OUT OF LIMITS. INST 3EA NEW SHEAR TIES STA 1540, STR 36R-39R IAW BAC DWG 140T2102, 146T1222 SRM 51-40-02.
MAIN CABIN FLOORBEAM AT STA 852 AT RBL 74.81 UPPER SURFACE HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: CORROSION IS OUT LIMITS IAW SRM 53-00-51, PG 102. FABRICATED & INSTALLED T-CHORD, FILLER & SPLICE ANGLE IAW SRM 53-00-51, REPAIR 3.
AFT RIGHT DOOR LOAD LIMITER INDICATOR NUT OUT OF LIMITS, MORE THAN 1-8 INCH FROM HOUSING. REMOVED AND REPLACED AFT RIGHT DOOR LOAD LIMIT INDICATOR IAW B767 AMM.
RIGHTT ENGINE IDG VALVE C/B POPPING. THIS IS M31 CB(28VDC). IT IS CHRONIC AND MEL 7521D CANNOT BE USED TO DF THE RIGHT IDG VALVE, DUE TO STATING AFTER DEACTIVATION OF THE VALVE PUSH THE C/B IN. THIS ITEM NEEDS TO BE FIXED OR PROVISION OF MEL GET CHARGED. REPLACED GCU NR 2; RIGHT ENGINE, OPS CHECK GOOD.
RIGHT WING SLIDE DOOR EICAS MESSAGE.
DURING PREFLT EICAS MESSAGE MAIN BATTERY CHARGER ON STATUS PAGE CANNOT ERASE. REMOVED & REPLACED BATTERY CHARGER, OPS CHECKS GOOD.
OFF GATE, AFTER ENG START, CIRCUIT BREAKER M31 FOR RT ENGINE IDG VALVE TRIPPED. REPLACED CIRCUIT BREAKER AS PRECAUTION. WIRE W3538-017-20 REPLACED. PERFORMED ENGINE IDLE RUN FOR 5 MINUTES ALL INDICATIONS NORMAL. WIRE REPLACED IAW SWP AND WDM 24-11-21.
CB M31 POPPED OUT WITH NO FURTHER INDICATIONS DF420. IDG AIR OIL COOLER DEACTIVATED IN OPEN POS SECURED TO CLOSE BY ELECTRICAL HARNESS. CB PULLED AND SECURED. REPLACED IDG AIR OIL HEAT EXCHANGER AND VLV NO LEAKS, NO FAULTS, NO MESSAGES.
NR 1 ENG OIL PRESSURE INDICATION FAULT, TEMPERATURE AND QUANTITY NORMAL; OIL PRESSURE FLUCTUATING OR INTERMITTENT. WENT TO 400 PSI AFTER CLIMB POWER SELECTED INTERMITTENT NORMAL TO 400 PSI. NO LEAKS FOUND AFTER OIL PSI TRANSMITTER REPLACED. STATIC RUN CHECKED OKAY.
DOOR 1R EVACUATION SLIDE BUSTLE HAS DAMAGE FROM GALLEY CONTAINER. BUSTLE HAS PUNCTURE APPROX 2 BY 2 INCHES LOCATED 6 INCHES FROM BOTTOM OF BUSTLE ON TRAILING EDGE, TWO GOUGES APPROX 18 INCHES AND 24 INCHES FROM BOTTOM OF BUSTLE. REMOVED BUSTLE AND INSPECTED SLIDE ASSY, NO DAMAGE TO SLIDE ASSY. ACCOMP INTERIM REPAIR TO BUSTLE WITH TAPE. BUSTLE TO BE REPAIRED WITHIN 20 DAYS. REPAIRED PUNCTURED BUSTLE PER GNMM, FILLED SMALL GOUGES, SMOOTHED AND PAINTED. REMOVED DOOR 1R EVACUATION SLIDE BUSTLE FOR REPAIR FOR CF0385. INSTALLED 1R BUSTLED.
RIGHT PACK INOP, LIGHT ON. EICAS MSG 'RIGHT PACK TEMP 'DISPLAYED. PERFORMED BITE CHECK THAT REVEALED BAD PACK EXHAUST ACTUATOR. REMOVED AND REPLACED RIGHT PACK EXHAUST ACTUATOR. WORKS OK. NO FAULTS.
AIR RETURN DUE TO STAB TRIM INDICATION. TROUBLESHOOTING FOUND STAB WOULD RUN AT FULL SPEED IN NOSE UP DIRECTION AND HALF SPEED IN NOSE DOWN DIRECTION. IN BLOCK 6 OF FIM FOUND STAB WOULD NOT GO IN NOSE DOWN DIRECTION 104400 ALSO HAD 0.2 OHMS, AND IN NOSE UP DIRECTION IT RAN AT HALF SPEED, NORMAL. IN STEP 7 OF FIM FOUND CONNECTOR D2211 OF L-H STAB MODULE M1607 FULL OF HYD FLUID AND PIN 2 PUSHED BACK. CLEANED CONNECTOR AND REINSTALLED PIN. RERAN FIM AND ALL CK'S NORMAL. MESSAGES CLEARED AND NO FAULT BALLS ON LT OR RT SAM'S.
MAINT REPORTS FUEL LEAK FROM RT WING ACCESS PANEL INBOARD NR 5 DRIP STICK. PANEL 641KB MOLDED RUBBER SEAL DAMAGED. MOLDED RUBBER SEAL REPLACED PER AMM. FUEL LEAK CHECK PERFORMED. FOUND NO LEAK.
CAPTAIN'S SLIDING WINDOW DEFECTIVE. REMOVED CAPTAIN'S SLIDING WINDOW IAW MM.
FIRST OFFICER'S FIXED WINDOW DAMAGED. INSTALLED NEW WINDOW IAW MM.
CAPTAIN'S NR 3 FIXED WINDOW DEFECTIVE. REMOVED AND INSTALLED NEW WINDOW IAW MM 56-11-10.
SATCOM INOP FROM ORD TO LHR. REPLACED SDU PER MM.
INTERCOSTAL IN AREA OF DAMAGE IS DENTED. REMOVED DAMAGE INTERCOSTAL. REPLACEMENT PART ON ORDER. PER ENGINEERING REMOVED 5 FASTENERS AND MAPPED OUT DAMAGE AREA FOR SKIN THICKNESS CHECK. ACCMP'D THICKNESS INSP OF BLENDED AREA, FOUND THICKNESS BLEND TO BE .046 INCH OR 23% OTHERS WERE .016, .002 AND .002. COMPLETED BLENDING OF 4 AREAS. CURRENT PTT 81,389.24 GOUGE AT RT FUSELAGE BS 1373. GOUGE WORKED AS PER EC-RA#5330-04217. OK TO CONTINUE IN SERVICE FOR 50 FLYING HOURS MAX. ACCMP'D PERMANENT REPAIR PER ECRA 5330-04217.
DAMAGE AT RT FUSELAGE STATION 1373 BELOW STRINGER 28R REQUIRES BLENDING TO REMOVE DAMAGE AND HFEC. BLENDED 4 AREAS REF SRM 53 -00-01, AND ACP'D HFEC INSPECTION OF DAMAGED AREAS REF NDT MAN PART 6 FOUND NO CRACKS. TWO UPPER DAMAGED AREAS OUT OF SRM ALLOWABLE DAMAGE LIMITS.
RIGHT ELEVATOR POSITION INDICATION INOP DURING FLT CONTROL CHECK. ALL 3 HYD SYSTEMS PRESSURIZED. CYCLE FCC AC CB'S, NO HELP. SWITCHED EICAS COMPUTER FROM LEFT, RIGHT AND BACK TO AUTO, NO HELP. VERIFIED OPERATION 908-12. RPL'D LEFT EICAS COMPUTER PER MM, CHECKED WIRES TO XMITTR. NO INDICATION PROBLEMS, SYSTEM OPS NORMAL.
LEFT IRS FAULT ON ALIGNMENT. REPLACED LEFT IRU PER MM, ACCOMPLISHED TEST 30 PER MM. OPS CHECK GOOD.
RUDDER RATIO LIGHT & EICAS MSG, RTFL. FAULT BALL FOUND IN PCA POSTION ON BOTH RRCM'S. REPLACED RRCA WITH BORROWED PART S-N 1008. OPS CHECKS GOOD, NO FAULTS.
LEFT ENG ANTI-ICE VALVE LIGHT ON. VERIFIED SOLENOID AND VALVE OPERATION PER MEL ITEM 3021C. MEL REF: 3021C. PARTS: 643-9002 MR30133 VALVE ASSY. REPLACED WITH NEW TAI VLV, OPS CHECKED NORMAL PER MM
LEFT ENG ANTI ICE VALVE LT ON WITH ENG SHUT DOWN AND SWITCH IN OFF POS. CLEANED ELEC CONNECTOR ON ENG INLET THERMAL ANTI-ICE VLV. LIGHT EXTINGUISHED. PROBLEM RECURRED.
AT DEPARTURE CENTER FUEL PUMPS REMAINED ON WHEN THEY SHOULD HAVE SHUTOFF. FOUND FUELING DOOR AJAR SECURED FUELING DOOR, OPS CKS OKAY.
FOUND RT ENG INB TR DAMAGED AND STRUT FAIRING COVER MISSING AT THE 9 O'CLOCK POSITION. DAMAGE IS APPROX 7"X .5" WIDE WITH A DEPTH OF .5". PER AVO #1103 COMPLETED REPAIR STEPS 1-5. SEALANT NEEDS TO BE CONFIRMED CURED AND STEP 6 & 7 NEED TO BE COMPLETED. REF EC-RA #7831-01716 PERFORMED TEMP REPAIR OF CRACK AND GOUGE WITH RE-CHECK DUE AT EVERY #3SV & PERM REPAIR WITHIN 412 NOT TO EXCEED PTT 80652 HOURS. RE-CHECKED TO BE ACCMP'D EVERY 2SV NOT 3SV. -INF- :EC-RA #7831-01716 REVISED TO EC-RA 7831-01716 REV A TO ACCOMPLISH INSPECTION AT EACH 2 SVC. -INF- :MF8446 CREATED TO ACCOMPLISH RECHECK AT EACH #2SV.
EEL LIGHTS ON SEATS 19J THRU 22J ARE INOP. REPLACED CHARGER AND BATTERY, CHECKS GOOD.
EXTERNAL EEL LIGHT INOP BY NR 1 RIGHT DOOR. REPLACED LIGHT ASSY, CHECKS GOOD.
5 UNITS LEFT RUDDER TRIM NEEDED BOTH AT CRUISE AND DESCENT. ADJUSTED TOP RUDDER PCA FOR CTR SYS INPUT ROD PER MM. AIRCRAFT TRIM DISCREPANCY CHECK ACCOMPLISHED PER MM.
RT ELEVATOR MOVEMENT INDICATOR DOESN'T MOVE. DEFERRED PER SAMC. IF NEEDED REPLACE XMTR PER MM. RPL : TROUBLESHOOT PER FIM 27-3 1-00, NO FAULTS FOUND. REPLACED RIGHT ELEVATOR POSITION CB (4102 ) PRECAUTIONARY. ELEVATOR POSTION INDICATONS ARE NORMAL.
AT CRUISE, LEFT OIL PRESS FLUCTUATED FROM 190-400,THEN STAYING FROM 350-400. ALL ELSE NORMAL. REPLACED NR 1 ENG OIL PRESSURE TRANSMITTER PER MM. ACP'D ENG RUNS AND OIL PRESSURE INDICATIONS NORMAL. NO LEAKS NOTED.
COCKPIT EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT ASSY, OPS CHECKED OKAY.
ON ARRIVAL FOUND EVIDENCE OF HYDRAULIC LEAKING LEFT SIDE FUSELAGE BY APU. FURTHER INVESTIGATION SHOWED FLUID COMING FROM LOWER RUDDER AFT TRAILING EDGE DRAIN HOLE. FOUND UPPER RUDDER PCU PISTON SEAL LEAK POINT SEAPING UNDER 5 DROPS PER MINUTE AND CYCLE.
FUEL LEAK FROM THE TOP OF LEFT ENGINE FROM THE FUELING LINES. MAINT TEXT: DURING FUELING OPERATION, FUEL LEAKING FROM PYLON DRAIN AND IMMEDIATELY OUTBOARD OF FWD PYLON AREA ADJACENT TO L/E SLAT. FOUND FUEL LEAKING AT INBD FUELING ADAPTER, TIGHTENED ALL BOLTS AND PRESSURIZED FUEL MANIFOLD, ADDED ADDITIONAL 2000 LBS TO VERIFY NO FURTHER LEAKAGE AT MANIFOLD ADAPTER NOR PYLON DRAIN OF L/E AREA. SECURED PANELS.
EQUIPMENT COOLING OVERHEAT. REPLACED EQUIP COOLING SUPPLY FAN 1 DUE TO PRIOR HISTORY, VIBE SENSOR TRIPS NEW SUPPLY FAN, TRIED NEW VIBE SENSOR, STILL TRIPS NEW FAN. ORDERED ANOTHER NEW FAN OSTF U4874, NEED TO REPLACE FAN AGAIN.
FUSELAGE DAMAGED RT SIDE JUST AFT OF WING TO BODY FAIRING. GOUGED STA 1197 & 48 BETWEEN STRINGERS 32R AND 33R GOUGE IS 17 INCHES LONG BY 1-4 INCH WIDE AND 3-8 INCH AT THE DEEPEST POINT. PHOTOS ON THE RVI SITE. DAMAGE WAS CUTOUT AND RPR'D REF SRM RPR 14 BY INSTALLING FILLERS AND TWO DOUBLERS. INSPECTION THRESHOLD FOR THIS CAT-B RPR IS PTC:37500 WITH REPEAT INSPECTION INTERVAL OF 3,000 FLIGHT CYCLES REF SRM 53-00-01 RPR 14 TABLE V. THICKNESS OF EACH DOUBLER IS .071. ACCOMPLISH EXTERNAL LFEC REF NDT PART 6 AND EXTERNAL DETAILED INSPECTION.
LT ENG BLEED VALVE STUCK CLOSED ON GROUND. BITE TEST OF AIR SUPPLY MODULE FAULTS "PRSOV". REPLACED PRSOV FAILED HEALTH CHECK. REPLACED PRSOV. RAN NR 1 ENG PRSOV, OPERATES NORMAL.
ELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). REPLACED IDG PER MM AND ALSO REPLACED IDG DRIVE SEAL.
F/O WINDSHIELD WIPER WON'T STOP. ALSO THE CAPT'S OUTER PORTION OF WINDSHIELD WIPER DOES NOT CLEAN RAIN FROM WINDOW. REPLACED F/O WIPER ARM ASSY IAW MM. REPLACED CAPT'S WIPER BLADE. OPS CHECK NORMAL.
CREW REPORT: JUST PRIOR TO TAKING RUNWAY L AC BUS FAILED. ACP TROUBLESHOOTING PER TABLE 102 REF MM P163 FOR DP TRIP AND MAIN BUS-OVERLAP. ALL WIRE CHECKS SAT. CREW ALSO REPORTED THE LEFT GENERATOR CONTROL TRIPPED AND THE LEFT TIE BUS ALSO FAILED. BOTH THE LEFT GEN CONTROL AND TIE BUS WERE ABLE TO BE RESET. WHEN THE LEFT AC BUS WAS NOT POWERED THE RIGHT GEN POWER DIDN'T AUTO TRANSFER TO THE LEFT AC BUS. REMOVED AND REPLACED NR 1 ENG IDG PER MM. OPS CHECKED GOOD. NO LEAKS.
PER INBOUND CREW, LEFT BUSS TRIPPED ON THROTTLE ADVANCE DURING T/O. RESET AS REQUIRED. ITEM HAS HISTORY. DUE HISTORY OF THIS FAULT, THIS ITEM IS GENERALLY CAUSED BY A DEFECTIVE IDG. SUSPECT IDG INSTALLED BY PREVIOUS STATION FOR ANOTHER TYPE FAULT, NEEDS RPL. NO TIME TO T-S. IDG DISCONNECTED PER MEL AND APU SERVICED TO FULL PRIOR TO DEPARTURE. IDG REPLACED. AFTER TROUBLESHOOTING AND LOOKING AT HISTORY. REPLACED GCU AND OPS CHECK LEFT IDG. OPS OKAY.
LEFT GENERATOR DRIVE EICAS & DRIVE LIGHT ON DRIVE DISCONNECTED. REPLACED NR 1 ENGINE IDG, OPS CHECKED NORMAL.
EXIT SIGN DOOR 1R AS WELL AS FLOOR LIGHTING STRIP BY SAME DOOR ARE FLASHING ON AND OFF. REPLACED POWER SUPPLY BATTERY PACK M1552, OPS CHECKED OKAY.
APU WILL NOT START. REPLACED IGNITION UNIT.
EMERGENCY LIGHT ABOVE FLIGHT DECK DOOR IS INOPERATIVE. RESEATED LIGHT ASSY. WORKS NORMAL.
EMEGENCY LIGHT BY FWD GALLEY IS INOPERTIVE. REPLACED BATTERY, WORKS NORMAL.
SMALL EMERGENCY EXIT SIGN BY DOOR 1 RIGHT IS INOPERATIVE. REPLACED BATTERY, WORKS NORMAL.
EXTERNAL EEL LIGHT ON AFT RT DOOR IS INOPERATIVE. RELAMPED & REPLACED POWER SUPPLY ASSY, WORKS NORMAL.
EMERGENCY LIGHT ON SEAT 19K IS INOPERATIVE. SECURED SEAT CONNECTOR, CHECKED GOOD.
FLAP LT ON FMA W-FLAPS IND UP & VERIFIED UP VISUALLY AT 250 KTS. FMA CLR'D LATER. *SUPPLEMENTAL DATA UPDATE* PERFORMED MCDP GRD TEST PER MM, FOUND LAST FLT FAULTS, AP CTR MODE ERR, DIAGNOSTIC CODES, 110780, 120780, 130780, NO CURRENT FAULT ON TEST 30, FLAP SLAT ELECTRONIC UNIT BITE TEST OK. CREW REPORTED THAT AFTER MOVING THE FLAPS DOWN TO 1 DEG AND UP AGAIN ALL RETURNED TO NORMAL THROUGH THE FLIGHT.
CREW REPORTED CENTER TANK RIGHT FUEL PUMP PRESSURE LIGHT IS NOT ON WITH PUMP SELECTED ON PRIOR TO START. REPLACED THE LOW PRESSURE SWITCH S424 PER AMM. NO LEAKS NOTED. PRESSURE SWITCH SWAPPED FROM S806 R FUEL JETTISON PUMP. LOW PRESSURE SWITCH S806 INOP. REPLACED PRESSURE SWITCH S806. OPS CHECK OKAY.
PRIOR TO START RIGHT CENTER FUEL PUMP SHOWED ON. DEFERRED RT CENTER FUEL PUMP AS PER MEL 2822H. ACP TEST OF RT CT OVERRIDE JETTISON PUMP PER MM, TEST OKAY. OPERATED PUMP TO TRANSFER FUEL FROM THE AUX TANK TO LEFT AND RIGHT MAIN TANKS, PUMP OPERATED OKAY. NEEDS TO FUEL AUX TANK AND PERFORM ENG START TO SEE IF FAULT RETURNS. COMPLETED TEST PER MM. ALL CHKS WERE GOOD.
RT ENGINE REAR STATOR MISSING WHOLE LOWER SKIN, UPPER SKIN BEGINNING TO COME OFF. INSPECT INTERMEDIATE CASE STRUT FAIRING IAW MM. INSPECTED COMPRESSOR INTERMEDIATE CASE STRUT AT 3 O'CLOCK POS. LOWER FAIRING MISSING. DAMAGE. CF IAW AMM.
MAIN BATTERY CHARGER STATUS MSG WILL NOT CLEAR. CHANGED APU CHARGER WITH MAIN BATTERY CHARGER. STATUS MESSAGE CLEARED, CHARGER OPERATES SATISFACTORY.
OXYGEN MASK INSP FOUND NUMEROUS O2 MASKS NOT PROPERLY PACKED. REPACKED AND STOWED 416 PASSENGER O2 MASKS IAW MM.
RT REAR ENTRY DOOR IS MISSING EMERGENCY LIGHT ILLUMINATION FOR DOOR RELEASE HANDLE. REPLACED RT REAR (4RT) EMERGENCY LIGHT ASSY. OPS CHECKS GOOD.
BLEED AIR DUCT PRESSURE INTERMITTENTLY SURGING BTWN 20-40 PSI AT ALTITUDES BELOW 8000 FT. OCCURRED TWICE ON CLIMB POWER SETTINGS (1.46 EPR). ON ARRIVAL IDLE POWER (1.02-.99EPR) WITH BOTH ISOLATION VALVES CLOSED AND RT PRESSURE WAS SLIGHTLY HIGHER SURGING. SEEMS OK (1.05-1.20 EPR RANGE). REPLACED PRSOV IAW MM, CHECKS OK.
RAMP REPORTED WHILE TOWING ACFT TO GATE EQUIPMENT COOLING HORN CAME ON AND AT GATE FOUND FWD EQ SUP FAN 1 STATUS MESSAGE. T-S IAW FIM 21-23-08 PAGE 107 BLOCK 6, WILL NEED RELAYS K1325, K1326 TO CONT. T-S. REPLACED RELAY K1319 AND NO HELP. REPLACED M876 EQUIP COOLING ANNUNCIATOR CARD, OPS CKS NORMAL.
WINDOW EICAS MESSAGE DISPLAYED. INOP LIGHT ILLUMINATED & DID NOT EXTINGUISH WHEN SWITCH WAS RECYCLED TO OFF/ON. SWAPPED WINDOW HEAT CONTROLLER, NO HELP. SUSPECT BAD WINDOW. WINDSHIELD CONTROL BITE FAILED, UNIT REPLACED; NOW FAULTS WINDOW 3R. INTERNAL RESISTANCE OUT OF LIMITS BETWEEN J12 AND J9. OPS CHECK FAILS 3R. REPLACED WINDOW ASSY.
RECENT HISTORY OF 'SPOILER' EICAS MSG WITH 'PCA' FAULT BALL SET ON SCM 2L. DUE TO RECENT HISTORY OF 'SPOILER' EICAS MSG WITH 'PCA' FAULT BALL SET ON SCM 2L. DUE TO SUCCESSFUL RESET AFTER REMOVAL & CLEANING OF PCA CONNECTORS; REMOVE INSPECT AND REPLACE IF NECESSARY NR3 & NR10 CA CONNECTORS, CHECK THE RESISTANCE OF NR3 AND NR10 PCA CONNECTORS IAW FIM AND DOCUMENT MEASURED RESISTANCE. IF RESISTANCE OK REPLACE SCM 2L WITH A -200 SERIES SPOILER CONTROL MODULE (481-9211). CONSULT ON-LINE IPC FOR PARTS LIST CURRENCY. RESISTANCE READINGS NR3 1-3 940 2-4 950. NR10 1-3 945 2-4 940. REPLACED SCM 2. OPS CHECKS OK.
RIGHT TANK FUEL SUMP HAS FUEL SEEP AT OUTER CIRCUMFERENCE. REPLACED RT TANK SUMP DRAIN VALVE. OPS NORMAL.
FLOOR CABLE EXPOSED 30B. SECURED CABLE.
RIGHT ENGINE BLEED OFF LIGHT ON & RT ENG BLEED OFF EICAS MESSAGE, WITH ENG RUNNING, ENG BLEED SWITCH ON, LT & RT ISOLATION VALVES CLOSED, AC PACK SELECTED ON, & DUCT PSI IS ZERO. OFF LIGHT STAYS ON WHEN N1 IS ABOVE 41%. REPLACED PRSOV PER MM. ACP ENG RUN PER JRH ALL OPERATION AND INDICATIONS NORMAL.
FO'S ALT FAILURE, RTFL. REPLACED F-O'S ALTITUDE INDICATOR PER MM, OPS CKS GOOD.
DAMAGE TO RT WING L/E. RT WING INBD SLAT OTBD TIE ROD DAMAGED. PANEL R & R TO SHOP 273 (AOG D0385). WORKING WITH EG FOR REPAIR OF L/E WHERE PANEL SCREWS UP TO. ALSO ROBBING PANEL FROM TPA. REPLACED CONTROL ROD. ACCMP'D INSTALLATION INSP.
RIGHT ENGINE BLEED LIGHT CYCLED ON AND OFF 3 OR 4 TIMES DURING DESCENT AT 80 PERCENT N2. AIR SUPPLY BITE MODULE FAULTS HPC. DEFFERED IAW MEL AND LOCKED HPSOV. REPLACED RT ENG HPC, OPS NORMAL DURING ENG RUN.
EICAS RT PACK OFF. RAN C-L.PACK RETURNED TO NORMAL OPS. PROBLEM REOCURRED. ACCOMPLISHED TROUBLESHOOTING. NO FAULTS ON PACK TEMP CONTROLLER. PACK INOP ON GROUND. SUSPECT FLOW CONTROL VALVE PCN 643-9118. FLOW CONTROL VALVE LOCKED. REPLACED RT FLOW CONTROL VALVE, TESTED OK.
RIGHT ENGINE BLEED LIGHT CYCLED ON AND OFF 3 OR 4 TIMES DURING DESCENT AT 80 PERCENT N2. AIR SUPPLY BITE MODULE FAULTS HPC. DEFFERED PER MEL AND LOCKED HPSOV. REPLACED RIGHT ENG HPC PER MM, OPS NORMAL DURING ENG RUN.
EICAS R PACK OFF. RAN C-L. PACK RETURNED TO NORM OPS. THEN PROB REOCCURRED. ACCOMPLISHED TROUBLESHOOTING. NO FAULTS ON PACK TEMP CONTROLLER. PACK INOP ON GROUND. SUSPECT FLOW CONTROL VALVE FLOW CONTROL VALVE LOCKED. REPLACED RT FLOW CONTROL VALVE, TESTED OKAY.
NR 1 ENGINE VALVE LIGHT INDICATION, RTFL. FMU FOUND FAULTY. REPLACED FMU. GROUND TEST NR 3 IDLE RUN TEST NORMAL.
BSTR PUMP LOW PRESS LIGHT-ON, RTFL. REPLACED RT AFT BOOST PUMP. FOUND R AFT FUEL BOOST PUMP CB (G21) TRIPPED. REPLACED CIRCUIT BREAKERS C371, C370 AND WIRES CONNECTED TO CB'S. ALL BOOST PUMPS TEST GOOD.
EXTERIOR EEL LIGHT BY DOOR 1 RIGHT IS INOPERATIVE. RELAMPED, NO HELP. CLEANED AND ADJUSTED LAMP CONTACTS, CHECK OKAY.
LOWER EEL EXIT SIGN BY RIGHT AFT OVERWING EXIT DOOR IS INOP. BY- 116760 REPLACED BATTERY, CHECKS GOOD.
EEL LOWER EXIT SIGN BY FWD RIGHT OVERWING EXIT DOOR IS INOPERATIVE. REPLACED BATTERY, CHECKS GOOD.
EEL LIGHT SWITCH GUARD ON FLIGHT DECK OVERHEAD PANEL IS LOOSE. SECURED GUARD.
EMERGENCY FLOOR STRIP BY RIGHT MID LAV IS INOP. REPLACED BATTERY, CHECKS GOOD.
GROUND HANDLING TRU CB ON P34 POPPED. REPLACED TRU AND TRU CB PER MM, NO HELP. CB APPEARED TO POP WHEN UNDER LOAD AND WOULD ONLY STAY IN WHEN FWD AND AFT CARGO HANDLING CBS WERE PULLED. REMOVED AND CLEANED CONNECTOR D4926P. INSPECTED WIRING IN P34 PANEL AND ACCOMPLISHED SHAKE CHECK OF WIRING AROUND P34 PANEL. CB NOW STAYS SET EVEN WHEN UNDER HIGH LOAD.
R AFT BOOST PUMP C/B POPPED, FLT DIVERTED. REPLACED RIGHT BOOST PUMP PER MM, ALL OPS AND CHECKS NORMAL.
FUEL CROSSFEED VALVE LIGHT-ON-& "FUEL CROSSFEED" EICAS MSG. DISPLAYED WHEN CROSSFEED SWITCH -OPEN OR CLOSED- SELECTED. AFT CROSSFEED VALVE WILL NOT OPEN- VALVE LIGHT ON WITH SWTCH IN OPEN POSIT. VALVE LIGHT OUT WITH SWITCH CLEARS DEFERRED AFT CROSSFEED VALVE INOP IAW MEL 2822R PROCEDURES. REPLACED ACTUATOR FOR AFT CROSS FLOW VALVE. OPS NORMAL.
RUDDER RATIO LIGHT ILLUMINATED, FLT DIVERTED. ACCOMPLISHED OVERWEIGHT LANDING CHECK. CREW REPORTED SOFT LANDING NO DAMAGE FOUND. ACCOMPLISHED TROUBLESHOOTING IAW FIM, NO FAULTS INDICATED. ACCOMPLISHED CSEU CKS IAW MM. NO FAULTS INDICATED. UNABLE TO DUPLICATE FAULT ON GRD LHR.
L FUEL PUMPS OVERRIDING CENTER. DID FUEL CONFIG IRREG PROC TO CORRECT PROBLEM. OK NOW WITH 3000 LBS SPLIT UNTIL CENTER USED. LEFT CENTER PUMP INOP. REPLACED SLEEVE IAW WITH COA. ALSO REPLACED PUMP. SYSTEM OPS CK'D AND REACTIVATED.
DOOR 2R BUSTLE UPPER AFT LATCH IS CRACKED. BOTH ITEMS ON AOG. (160-1143 = AOG K1897, 160-1158 = AOG N1993) LATCH CLOSES, LATCHES AND LOCKS NORMAL, BUT ONE SIDE OF LATCH IS BROKEN AND NEEDS TO BE REPLACED. LATCH ASSY PCN 160-1158 ON EXP E1777.
NR 2 ENG N1 VIB INDICATION FLUCTUATES WITH EPR CHANGE. NO VIBES FELT IN STABLE CRUISE. NO ACTUAL VIB FELT, CREW FELT ISSUE TO BE FAULTY IND. REPLACED AVM UNIT.
38E, OVRHEAD BIN, STILL DRIPPING WATER, SEEMS TO BE ONLY IN FLIGHT. REPLACED SEVERAL CROWN ARE A INSULATION BLANKETS THAT WERE FOUND WET WITH CONDENSATION. REPLACED CEILING PANELS.
RT INBD AILERON IS GOUGED ON LOWER SURFACE. DAMAGE MEASURES .5" BY 10" IN LENGTH. PREPPING TO REMOVE AILERON. DURING THE RT INBD AIL OPS TEST, ACFT FAILS TEST. ALL OTHER TEST REQUIREMENTS CK NORMAL. ACCOMPLISHED REMOVAL AND INSTALLATION OF ROBBED AILERON IAW MM. COMPLETED INSTALL OF AILERON IAW MM. DURING TEST FOUND SPOILERS 6 & 7 DO NOT FUNCTION PROPERLY DURING SINGLE HYDR SYS OPS. AFTER RESET THEY WILL WORK TWICE AND LOCK OUT. TRIED SEVERAL SCM'S 3R. SEVERAL FROM STOCK AND SWAPPED POSITION WITH OTHER SCM'S, NO HELP. WILL REQUIRE FURTHER TROUBLESHOOTING. RT WING INBD AILERON POSITION TRANSMITTER CONTROL CRANK EARS ARE CRACKED. REPLACED AS REQUIRED. REPLACED CONTROL CRANK AND ADJUSTED, OPS NORMAL.
CARGO DOOR EICAS MSG, RTFL FOUND BURNED PIN ON FWD CARGO DOOR HARNESS CONNECTOR D6266.PIN 20 POWER FOR DOOR LTS, ARCING TO PIN 8 WHICH IS PROX SENSOR S215. REPLACED CONNECTOR D6266 AND BACK CONNECTOR. DOOR OPS CHECKS GOOD.
RT WING SLIDE EICAS, RTFL. FOUND S219 PROX SENSOR WIRING CHAFED AT AFT SIDE OF SLIDE COMPARTMENT, REPLACED SENSOR AND ASSOCIATED WIRING. FOUND HARD FAULT ON PSEU FOR PROX, LOGIC AND DRIVER CARDS FOR S219 SENSOR. REPLACED PROX, LOGIC AND DRIVER CARDS FOR S219 IN POSITIONS 3 - 5 AND 7 RESPECTIVELY. OP CHECKS NORMAL.
EICAS MSG ENG ANTI-ICE DISPLAYED AND ENG ANTI-ICE VALVE LIGHT REMAINED ILLUM WITH SWITCH OFF, POSITION 1. PERFORMED T-S FOUND ENG ANTI-ICE VALVE INOP. REPLACED VALVE. RAN ENGINE. ENG ANTI-ICE VALVE WORKS OKAY.
RIGHT EDP EICAS MSG. OVERHEAT LIGHT CAME ON WITH LOW PRESS, CREW TURNED THE PUMP OFF AND OVERHEAT LIGHT WENT OUT, PUMP LOW PRESS LIGHT ON. REPLACED NR 2 ENG EDP. OP CHECKS NORMAL.
NO LIGHT OFF ON START OF LEFT ENG. RAN QRC. PUSH CREW ADVISED SPARKS SEEN FROM FRONT OF ENG. FOUND STARTER FAILED. REPLACED STARTER AND START VALVE. ACP'D IDLE RUN AND ALL OPS GOOD.
LEFT EXTERIOR EMERGENCY LIGHT INOP 2EA AT FUSELAGE JUST AFT OF T/E FLAPS. REPLACED BOTH LAMPS, OPS CHECKED OKAY.
R EICAS COMPUTER MSG ON STATUS: WHEN RIGHT EICAS COMP SELECTED, BOTH UPPER AND LOWER EICAS DISPLAYS ARE BLANK. REPLACED RIGHT EICAS COMPUTER, DOWN LOADED SOFTWARE BOTH RIGHT AND LEFT ARE THE SAME, RAN TEST AND BOTH UPPER AND LOWER SCREENS ARE OK.
VERY STRONG SMELL IN MID GALLEY (SMELLS LIKE BURNING PLASTIC). NEEDS DEEP CLEAN OVEN W41. CLEANED MELTED PLASTIC TRAY FROM BOTTOM OF WARMING OVEN.
FOUND DENT AT 10 O'CLOCK POSITION AT 18 INCHES FROM RADOME AFT EDGE. AREA COVERED WITH TAPE. INSPECTED RADOME. DENT IS WITHIN LIMITS. REPLACED RADOME.
NR 1 VHF COMM XMISSION & RECEPTION INOP. REPLACED LT VHF RECEIVER TRANSMITTER, OP CHECKED OKAY.
EQUIP COOLING EICAS AND OVERHEAD. REPLACED EQUIP COOLING INDICATION CIRCUIT BOARD. REMOVED AND CLEANED LOW FLOW SENSORS, HAVE HAD NO FAULTS FOR 1.5 HOURS AT ORD. EQUIP COOLING TEST OKAY.
RIGHT HF ISSUE. FLIGHT DIVERTED. REPLACED RIGHT HF COUPLER. SAFTIED ALL CONNECTORS AS REQUIRED. FOUND D4839P AND D4841P LOOSE, MADE WRITE UP. NEED TO ACCOMPLISH OP CK OF LEFT AND RIGHT HF. PERFORMED MM23-11-00 AND MADE CALLS FROM AIRPLANE TO AIRPLANE AND AIRPLANE TO ANDREWS AIR FORCE BASE BOTH LEFT AND RIGHT OPS OK.
RIGHT L/E NR 7 SLAT CLOSURE PANEL HAS DAMAGE. NR 7 LEADING EDGE SLAT REPAIRED BY SFO SHOP ON R&R R42774, REINSTALLED ORIGINAL SLAT WITH NO ADJUSTMENTS DISTURBED DURING REMOVAL OR INSTALL. CHECKED FIT & FAIR AFTER INSTALLATION AND SOLD TO INSPECTION. INSPECTED SAFETY AND SECURITY OF NR 7 SLAT, VERIFIED FIT AND FAIR AND PROPER OPERATION.
LEFT AFT DOOR EMERGENCY LIGHT (EXTERNAL) IS INOP. RELAMPED AND OPS CHECKS GOOD.
MAIN CABIN STA 1307, STR 17R DRILL DAMAGE IN RADIUS OF STRINGER. MAJOR REPAIR ACCOMPLISHED: BLENDED BEAR STRAP DAMAGE AND INSTALLED STRINGER SPLICE REPAIR.
EXT FUSELAGE SKIN STA 1542, BL 0 IS CORRODED AROUND DRAIN HOLE STR 39L - 39R. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SKIN AND INSTALLED DOUBLER TRIPLER REPAIR.
DURING G4 GALLEY CHILLER CIRCUIT BREAKER INSP, FOUND BUS WIRE DISCONNECTED AT C-B C9032 A1 POSITION. INSTALLED BUSS WIRE. OPS CHECKS GOOD.
NR 2 PYLON HYD BATTERY HARNESS WIRE W394-8-18 FOR T-R PRESSURE SWITCH IS CHAFED PAST PRIMARY CONDUCTOR. REMOVED DAMAGED WIRE FROM PLUG D2138 AND JACK D41705. INSTALLED NEW WIRE. T-R OPS CHECKS GOOD.
NR 1 PYLON HYD BATTERY HARNESS WIRE W390-082-18 FOR L ENG T-R HYD ISLN VALVE PRESSURE SWITCH IS CHAFED TO PRIMARY CONDUCTOR. REMOVED WIRE FROM PLUG D20 122, INSTALLED NEW SOCKET AND RE-ASSEMBLED. INSTALLED NEW WIRE. OPS CHECKS GOOD.
STA 1307 STR 17R STR CLIP CORRODED. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED NEW STRINGER CLIP.
DURING INSPECTION OF APU GEN POWER CABLES, FOUND EVIDENCE OF OVERHEATING AT SPLICE AREAS. DAMAGE AT STA 1809 BULKHEAD BELOW RT HORIZ STAB PIVOT PIN. REMOVED OLD APU GENERATOR SPLICES. INSTALLED NEW SPLICES REF BSWPM 20-30-13 AND INSTALLED STAR SPACERS. OPS CHECKS GOOD.
NR 1 ENG IDG FEEDERS ARE DETERIORATED. INSTALLED NEW FEEDER IDG CABLES. OPS CHECKS GOOD.
DOOR R2 SLIDE UNLACED. REPLACED SLIDE DEPLOY PEN.
AFT CARGO PIT STATION 1562 FAIL SAFE CHORD CORRODED AT BL 0. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED SECTION OF FAIL SAFE CORD. FABRICATED & INSTALLED REPAIR ANGLE DOUBLER AND FILLER.
NR 1 PYLON HYD BAY HARNESS WIRE W398-201R-18 FOR L ENG HYD PUMP HAS AN IMPROPER SPLICE INSTALLED. REPAIRED WIRING REF BSWPM 20-00-13, 20-61-11 AND B767 WDM 29-11-12. RE-ASSEMBLED PLUG 0916 AND JACK D4280J TO INSTALL NEW SECTION OF WIRING.
AFT CARGO COMPT SHEAR TIE CLIP EVIDENCE OF CORROSION AT LWR AFT SIDE OF WEB STA 1351, LBL 12- LBL 17, STR 35L -37L. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
EVIDENCE OF CORROSION AT LWR SKIN TO FLOOR WEB AFT SHEAR TIE STA 1285, STR 39R - 39L. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT CARGO COMPT BILGE SHEAR TIE EVIDENCE OF CORROSION AT LWR SKIN ATTACH POINT AFT SIDE OF FLOOR WEB STA 1307, STR 35L TO 36L. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT CARGO COMPARTMENT BILGE SHEAR TIE CORRODED STA 1219, STR 39R TO 38R. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
EVIDENCE OF CORROSION AT LWR SKIN TO FLOOR WEB AFT SHEAR TIE STA 1285, BL 0, STR 39R TO 38R. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
DOOR 2R SLIDE RELEASE CABLE UNLACED. REINSTALLED RELEASE CABLE.
EXTERNAL FUSELAGE SKIN GOUGED-DENTED, STA 1317 TO 1320, STR 31L TO 31L. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGED SKIN. FABRICATED AND INSTALLED DOUBLER REPAIR.
BULK COMPARTMENT STA 1563 DRAIN HOLE AT CENTER LINE CORRODED AT AFT SIDE OF SHEAR TIE STA 1563, STR 39L - STR 39R. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT FUSELAGE STA 1540 SHEAR TIE BETWEEN STR 37R AND 36R IS CORRODED. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT FUSELAGE STA 1540 SHEAR TIE BETWEEN STR 38R AND 37R IS CORRODED. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT FUSELAGE LWR INTERIOR SHEAR TIE STA 1540 BETWEEN STR 39L AND 39R CORRODED. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT CARGO COMPT BILGE SHEAR TIE CORRODED STA 1219, STR 39R TO 39L. MAJOR REPAIR ACCOMPLISHED: FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT CARGO COMPARTMENT BILGE SHEAR TIE CORRODED STA 1197+132, STR 39L. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED SHEAR TIE.
CABIN, LT FWD OVERWING HATCH, LINER HANDLE PULL SHROUD FWD AND AFT CLIPS MISSING. REPLACED CLIPS.
MAIN CABIN SEAT TRACK HAS SEVERAL AREAS OF CORROSION STA 754 - 786, RBL 88. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED NEW SEAT TRACK SECTION.
AFT FUSELAGE LWR INTERIOR SHEARTIE STA 1540 BETWEEN 38L AND 37L IS CORRODED. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
AFT CARGO COMPARTMENT BILGE SHEAR TIE CORRODED STA 1197+132, STR 39R. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED NEW SHEAR TIE.
MAIN CABIN FLOORBEAMS FLANGE WORN AT CLIPNUT HOLES BS 1197 - BS 1197, RBL 12 - 50. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGE AND INSTALLED REPAIR STRAP AND ANGLE DOUBLER.
MAIN CABIN FLOOR LEVEL SEAT TRACK HAS A BROKEN SECTION STA 786.0, LBL 89.5. MAJOR REPAIR ACCOMPLISHED, CUTOUT DAMAGED SEAT TRACK, FABBED AND INSTALLED NEW TRACK SECTION.
NR 2 PYLON INBOARD SAILTAIL AT AFT LOWER STRUT FAIRING, 3 -8TH HUCK BOLT INSTALLED. MAJOR REPAIR ACCOMPLISHED, REMOVED DAMAGED SKIN SECTION. FABRICATED NEW SKIN FROM .05 INCH INCONEL AND INSTALLED.
AFT FUSELAGE LWR INTERIOR SHEAR TIE STA 1549 BETWEEN STR 39L AND 38L IS CORRODED. MAJOR REPAIR ACCOMPLISHED, INSTALLED NEW SHEAR TIE P-N 140T2102U585.
MAIN CABIN, STA 1330 FAR RT OTBD SEAT TRACK, RBL 88, CORROSION IN SEAT TRACK. MAJOR REPAIR ACCOMPLISHED, INSTALLED NEW SECTION OF SEAT TRACK STA 1197 +44 TO 1430, RBL 88.5. PN 654T0513-1146.
AFT FUSELAGE LWR INTERIOR SHEAR TIE STA 1540 BETWEEN STR 39R AND 38R CORRODED. MAJOR REPAIR ACCOMPLISHED, INSTALLED NEW SHEAR TIE P-N 140T2102U585.
R-H OVERWING SLIDE DISCONNECT HOUSING CRACKED. SUPPLEMENTAL DATA UPDATE INSTALLED NEW DISCONNECT HOUSING. OPS CHECKED CABLE, OPS CHECKS GOOD.
R-H OVERWING SLIDE DOOR LATCHES REQUIRE REPLACEMENT DUE TO PLANNED SLIDE DEPLOYMENT. INSTALLED NEW SLIDE DOOR LATCHES. ADJUSTED LATCHES AS REQUIRED.
RT OVERWING SLIDE DOOR ALIGNMENT PIN SHEARED. REPLACED SHEARED PIN.
ASPIRATOR LEAKS. BARREL LEAKS, NO EXTERNAL DAMAGE, CAUSE UNKNOWN. REPLACED ASPIRATOR.
ALT FLAP SYSTEM WILL NOT EXTEND AND THE TRAILING EDGE INDICATION COMES ON EVEN WITH HYDRAULICS. NO MOVEMENT OF THE ALT SYSTEM (T/E SELECTED ONLY). REPLACED ALTERNATE FLAP MOTOR.
EMERGENCY EXIT LIGHT STRIP HAS EXPOSED WIRES LEFT SIDE FIRST CLASS. REPAIRED EMERGENCY LIGHTS STRIP.
LEFT WING NR 4 OUTBOUND SLAT LINKAGE PANEL HANGING DOWN. REPLACED LEFT WING NR 4 OUTBOARD SLAT LINKAGE PANEL, OPERATED SLATS, OPS CHECK NORMAL.
EICAS "C HYD PRIM 1" DISPLAYED. REPLACED NR 1 ACMP AND CONNECTOR D482. CASE AND DRAIN FILTERS REPLACED. ALL CHECKS OKAY. NO FAULTS NOTED.
LOSING UPPER EICAS DISPLAY INTERMITTENT NO COLOR AND DISPLAY MSG. REPLACED UPPER EICAS DISPLAY.
LT ASI DURING TAKEOFF ROLL WENT TO ZERO KNOTS. REPLACED LT PITOT STATIC PROBE.
FOUND NR 2 SPOILER ACTUATOR POURING HYD FLUID FROM PCU. NR 2 SPOILER ACTUATOR LEAKING. REPLACED ACTUATOR. VERIFIED RIG AND OPS CHECKS.
EEL EMERGENCY LIGHT STRIPS INOP ON LEFT AISLE IN THE VICINITY 1AB THRU 5AB. SECURED CONNECTOR, TEST OK.
HF INTERFERENCE FAULTS. REPLACED LT & RT COUPLER. OPS CHECKED. NO FAULTS. REPLACED LT TRANSCEIVER.
EMERGENCY LIGHT STRIP LOOSE AT 14B. SECURED EMERGENCY LIGHT PLASTIC COVER AT SEAT 14B. OPS GOOD.
RUDDER AND AILERON TRIM EXCESSIVE WITH AILERON DEFLECTED. SUSPECT LEFT INBD AILERON STUCK IN UP POSITION, AS IND ON EICAS FLT CONT, IS DEFLECTED APPX HALF UP AND NOT RESPONDING TO INPUT. RUDDER AND AIL TRIM IS EXCESSIVE. AILERON FOR 6 HRS WAS ABOUT HALF DEFLECTED AND THEN WORKED ITS WAY TO ABOUT 1-4 DEFLECTION AS SEEN IN YOKE AND TRIM USED. FOUND LT INBOARD AIL, BOTH LT & CNTR SYS PCA'S HAVE QUICK DROOP & ARE BYPASSING (BOTH PCA'S MANUAL MANIPULATION WITH SYS PRESS APPLIED). REPLACED CTR SYS PCA. REPLACED LT INBOARD & OUTBOARD AILERON LEFT SYSTEM PCA. REPLACED RT NR 7 OVERRIDE SPOILER ACTUATOR & LT SPOILER OVERRIDE ACTUATOR.
L HYD SYS MAINT STATUS MESSAGE. FOUND L EDP SHAFT SHEARED, REPLACED PUMP, OKAY.
DURING CLIMB LEFT ENG OIL PRESS PEGGED OUT AT 400 PSI AT LEVEL OFF PRESS JUMPED TO 200. REPLACED OIL PRESSURE TRANSMITTER.
WINDOW L2 LOWER TRACK BRACKET CASTING CRACKED AT FWD OUTBOARD EDGE. REPLACED 2L WINDOW BRACKET.
ASPIRATOR LEAKING. SUSPECT FAULTY O-RING. REPLACED ASPIRATOR. AC OK FOR SERVICE.
ON WALK AROUND, FOUND FRONT END OF LT GEAR BOGIE LOWER TRAY DAMAGED 4 RIVETS BROKEN AND 1 INCH CRACK ON MOUNTING BRACKET, BRACKET BEND. INSTALLED NEW FWD MOUNT BRACKET AND STRAIGHTENED LOWER TRAY. AC OK FOR SERVICE.
RTFL DUE TO DOUBLE TRANSPONDER FAILURE. RPLACED ATC ANTENNA SWITCH.
FLOOR LIGHT STRIP AFT OF 9AB BROKEN.
STATUS LIGHT ON FLASHLIGHT AT BUSINESS GALLEY NOT ON. REPLACED BATTERY OPS CHECKED GOOD. AC OK FOR SERVICE.
EEL LIGHT COVER ON FLOOR AT 13AB AND 14AB IS PULLED UP. SUSPECT NORMAL CREW AND PASSENGER BOARDING AND DEBOARDING. SPLICED IN NEW EEL STRIP OPS CHECK GOOD. AC OK FOR SERVICE.
EMERGENCY LIGHTS ON LEFT + MID SIDE OF 1ST CLASS GALLEY + LEFT SIDE OF CABIN FROM 1L TO MID LAVS. REPLACED EEL BATTERY.
END CAPS MISSING FROM EEL LIGHTING AT SEATS 1B AND 1F. INSTALLED END CAPS
LEFT SIDE CABIN FLOOR LIGHTING INOP IN BUSS AND 1ST CLASS. REPLACED LIGHTS, OPS CHECKS GOOD.
CREW REPORTED SMOKE IN CABIN AND RETURN TO FIELD.
RTFL UNDER AMBER ALERT DUE TO ELECTRICAL ODOR. REMOVED NR 2 ENGINE AFTER CONFIRMATION OF DIAGNOSTIC TEST FLT. LABEL ENGINE REMOVAL REASON AS CABIN OIL ODOR & CHRONIC HUNG START. OIL SMOKE ENTERING THROUGH THE BLEED INLETS.
EICAS MSG R GEN OFF DISPLAYED. GEN OFF LIGHT ILLUM. CREW COMMENTS: A-C DID NOT PICK UP AC BUS AFTER RT ENGINE STARTED.
FLIGHT DIVERTED DUE TO RIGHT ENGINE CORE COWL PROBLEM.
NR 1 ACMP DOES NOT COME ON LINE WHEN IN AUTO MODE AND EDP IS SWITCHED OFF.
EXTERIOR EMERGENCY LIGHT AT L-1 DOOR IS INOP.
RIGHT OVERWING SLIDE CYLINDER BOTTLE BALL IS BELOW THE SPRING FORCE MECHANISM.
EEL EXTERIOR DOOR 1R AND 2L INOP.
RIGHT FUSELAGE EVACUATION (EMERGENCY) LIGHT LOOSE STA 1230, STR 23R.
BS 246 FLOORBEAM STIFFENER CRACKED RBL 26. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED STIFFENER.
B-ZONE LEFT SIDE FWD 2 EA EEL LIGHT STRIPS ARE INOP.
EMERGENCY EXIT LIGHT AT LEFT AND RIGHT AFT DOORS, LWR PORTION OF LIGHT (DOOR HANDLE ILLUMINATION) IS INOP.
BIRD STRIKE TO NR 1 ENGINE. ACCOMPLISHED BOROSCOPE INSP OF NR 1 ENG HPC 5TH, 6TH, 10TH AND 11TH STG BLADES PER MM 72-00-00. FOUND 1 EA 6TH STG BLADE WITH LARGE TEAR IN AREA C OF L/E BEYOND FLYBACK LIMITS, 18 EA 10TH STG BLADES WITH DAMAGE BEYOND LIMITS IN AREA B AND C, AND 2 EA 11TH STG BLADES WITH LARGE TEARS BEYOND LIMITS IN AREA C. BY- 41440: REMOVED ENG 717676 & REPLACED. COMPLETED VERIFICATION FLIGHT & ENGINE TESTED GOOD.
F/O`S NR 1 WINDOW & CAPT'S SIDE WINDOW HEAT INOP. FOUND WINDOW HEAT WIRES BURNT BEHIND E2-1 RACK AT CONN D4294P, REF WDM 30-41-12. CONTROL SENSOR FOR LEFT WINDOW 2 MELTED AND OTHER WIRES HAVE HEAT DAMAGE. PWR WIRE W1120-203B-12 EXTENSIVELY DAMAGED. WIRES WERE REPAIRED AND HARNESS REINSTALLED IN A/C. HARNESS OPERATED OK. SUSPECT LOOSE PINS CAUSED HIGH CURRENT DRAW & C-B FAILED TO OPEN SOON ENOUGH TO PROTECT WIRES.
FWD GALLEY CROSS AISLE EEL STRIP INOP.
EMERGENCY POWER SUPPLY AT SEAT 20FG IS INOP. REPLACED POWER SUPPLY PER MM 33-51-07 AND OPS CHECK GOOD.
LT OVERWING SLIDE DOOR ACTUATOR SQUIB SHUNT CAP MISSING INSERT. REPLACED 3SF5951-501 SHORTING CAP. OK FOR RETURN TO SERVICE.
RIGHT DOWN LOCK SPRING ON NOSE LANDING GEAR SHEARED. REPLACED DEFECTIVE SPRING DUE TO WEAR WAS BEYOND LIMIT.
FAILURE OF F/O AIR DRIVEN COMPUTER AND ALTIMETER. RT AIR DATA COMPUTER RPL, MR41190, NO DASH, BUT S/N=88041280. A/C HAD PREVIOUS HISTORY ON 18 MAY. NO UNIT HISTORY AVAILABLE IN CIDER FOR THIS S/N, SUSPECT THIS IS 1ST REMOVAL.
LT O/W HATCH FAILS INTEGRATOR TORQUE CHECK. REPLACED LATCHES.
FLIGHT DIVERTED DUE TO RIGHT HYDRAULIC SYSTEM QUANTITY LOSS. REPLACED RIGHT SYSTEM EDP. NO FURTHER REPORTS NEXT 20 AC CYCLES.
MAIN CABIN BETWEEN BS 785.9 AND BS 814, LBL 55, SEAT TRACK CORRODED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SPLICE SECTION.
AFT PIT FRAME HAS 3 INCH PUNCTURE STA 1351, STR 24R TO 25R. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER REPAIR.
MAIN CABIN AT STA 1197+80 LBL 89 SEAT TRACK HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPLACEMENT TRACK AND SPLICES.
MAIN CABIN BETWEEN STA 774 AND 785 AND LBL 55, SEAT TRACK HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SECTION WITH SPLICE DOUBLERS.
CORROSION OUT OF LIMITS ON FLOOR SUPPORT ANGLE AT STA 368. OTBD BY LWR AFT R-2 DOOR ON STRUCTURE. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION.
MAIN CABIN SEATTRACK AT STA 654+14 RBL 89 IS CORRODED OUT OF LIMITS. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW SEAT TRACK SECTION WITH SPLICE DOUBLERS.
LEFT MOST FWD EMERGENCY EEL STRIP INOPERATIVE. SECURED EEL STRIP, OPS CHECK OK.
RT PRIM HYD OVERHEAT EICAS AND LIGHT. RIGHT HYDRAULIC QUANTITY DROPPED TO ZERO. RIGHT ENGINE DRIVEN PUMP REPLACED. FAILURE DUE TO FROZEN BEARINGS, PUMP OVERHEATED DUE TO LACK OF LUBRICATION.
PASSENGER BREATHING EQUIPMENT DAMAGED AT CLOSET 309. REPLACED PBE.
ON CLIMB FROM SFO RIGHT HAND GENERATOR DROPPED OFFLINE AND WAS UNABLE TO BE RESET. SUPPLEMENTAL DATA UPDATE REPLACED RIGHT GENERATOR.DEFECTIVE PARTS - FOUND DIODE, ROTOR AND EXCITER FAILED.
CAPTAINS OXYGEN MASK ASSEMBLY HEADBAND LEAKS AND WILL NOT COLLAPSE AROUND HEAD. MASK FAILED DUE TO NORMAL WEAR AND TEAR.
"MAIN BATT CHGR" MESSAGE DISPLAYED ON EICAS.
RT ENG OVHT EICAS MESSAGE. FOLLOWED FLIGHT MANUAL PROCEDURE, REDUCED THROTTLE, MESSAGE REMAINED. SHUTDOWN ENGINE. *S/D* THE EICAS RT ENG OVHT MSG WITHOUT DISCRETE LIGHT ON WAS CAUSED BY AFOLTS CARD M10274. THE CARD WAS REPLACED AND SYSTEM CHECKED OK. SHOP CHECK OF THE CARD CONFIRMED THE FAULT WAS A SHORTED COMPONENT ON THE CARD.
FIRE IN MID GALLEY OVEN, LOCATION R31 RECON-OVEN. HAND HELD EXTINGUISHER USED. DIVERTED PHL. OVERWEIGHT LANDING. *S/D* FOUND PAPER BURNED BETWEEN TOP OF OVEN RACK AND EXHAUST FAN OPENING. THE OVEN WAS REMOVED AND THE ELECTRICAL CONNECTORS WERE INSPECTED. NO DAMAGE WAS NOTED. THE C-B PANEL ABOVE THE OVEN WAS ALSO REMOVED AND INSPECTED. NO DAMAGE WAS NOTED. THE OVEN AND ALL GALLEY EQUIPMENT WERE OPERATED FOR 1 HOUR WITH NO FAULTS FOUND. THE OVEN WAS TESTED PER MM 25-31-00.
REJECTED TAKEOFF AT 100 KT DUE TO FLIGHT DECK WINDOW PROBLEM. *S/D* AIRCRAFT INSPECTED FOR HIGH SPEED RTO. NO DISCREPENCIES FOUND. NUMBER 1 SLIDING WINDOW WAS APPARENTLY NOT FULLY SECURED PRIOR TO DEPARTURE.
STRONG ELECTRICAL SMELL IN MID CABIN. NO SMOKE OBSERVED, UNABLE TO CLEAR SMELL FROM CABIN. DIVERTED OMA. *S/D* TRACED SMELL TO SEAT 10C VDU. ISOLATE WIRING TO MONITOR ASSY AND SEAT ELEC BOX. CAPS AND SECURE CABLES. (DEFERRED) REPLACED VDB (VIDEO DISTRIBUTION BOX) AND CONNECTED CABLES. OPS CHECKED NORMAL.
FORWARD SERVICE DOOR 1 RIGHT REQUIRES INTERIOR HANDLE TO BE PUSHED FULLY UP TO CLOSE. *S/D* MAINTENANCE FOUND THE INTERIOR HANDLE NOT HOLDING THE CORRECT POSITION WITH THE DOOR OPEN. THE SPRING HYDRAULIC SNUBBER WAS DEFECTIVE. REPLACED SNUBBER PER MM 52-11-31. OPS CHECKS WERE NORMAL.
SMOKE REPORTED FROM OVEN NR 305, FLT ATTENDANT DISCHARGED HALON FIRE EXTINGUISHER INTO OVEN. CB PULLED. CAUSE DUE TO PLASTIC AND PAPER MELTING AND OVERHEATING IN THE FAN AREA ON THE BAFFLE. OVEN REPLACED.
AIRCRAFT RETURNED TO BLOCKS WITH REPORT OF LEFT AFT EXTERIOR EMERGENCY LIGHTS ILLUMINATED. *S/D* PERFORMED EXTERIOR EMERGENCY LIGHTS TEST PER MM. NO PARTS REPLACED, NO FURTHER REOCCURRENCE OF DISCREPANCY.
AFTER LANDING GEAR EXTENSION, EICAS GEAR DISAGREE AND TAIL SKID WARNINGS. GEAR AND TAIL SKID WARNING LIGHTS ILLUMINATED ON LANDING GEAR INDICATION PANEL BUT HAD ALL GEAR DOWN LIGHTS GREEN. RECYCLED LANDING GEAR AND GOT ALL NORMAL INDICATIONS WITH NO ABNORMAL EICAS OR GEAR WARNINGS.
AIRCRAFT RETURNED TO SFO AFTER BOTH UTILITY BUS OFF LIGHTS CAME ON DURING TAKEOFF. *S/D* LEFT GENERATOR CONTROL BREAKER AUXILIARY CONTACT FAILED. REPLACED LEFT AND RIGHT GENERATOR CONTROL BREAKERS.
THE LEFT OVERWING EXIT DOOR REQUIRED 12 POUNDS OF FORCE TO OPEN DURING A MAINTENANCE CHECK. THE TARGET SENSOR WAS MISALIGNED IN THE INBOARD CORE OF THE DOOR. ADJUSTED TARGET SENSO, THE DOOR THEN OPENED FREELY AND THE ACTUATORS OPERATED PER DESIGN.
THE APU SHUTDOWN PRIOR TO ENGINE START. THE APU WOULD NOT RESTART. *S/D* THE SURGE CONTROL VALVE WAS DEFECTIVE AND REPLACED, OPERATIONS CHECK NORMAL. NO OTHER APU DISCREPANCIES HAVE OCCURRED SINCE THIS INCIDENT.
THE RIGHT NR 6 SLIDE LIGHT IS INOP. REPLACED LAMP, OPS CHECK NORMAL.