N6818
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| AMERICAN AIRLINES, INC. (AALA) | Operator | on 1974-07-10 | Operator named in NTSB report |
Accident & incident history
Operated by AMERICAN AIRLINES INC (per NTSB report)
Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
11 reports on file, 1995-10-10 – 1998-12-27.
Part: LIGHT — DEFECTIVE (ROW 30)
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH EXIT DECAL AT SEAT ROW 30 NOT PROPERLY LIGHTED. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT SEAT ROW 30. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: LIGHT — DEFECTIVE (ROW 3E)
DFW - DURING OVERNIGHT CHECK, EMERGENCY EXIT FLOOR PATH EXIT LIGHT AT SEAT 3E INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT SEAT 3E. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: LIGHT — INOPERATIVE (CABIN)
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY OVERHEAD EXIT SIGN LIGHT AT L2 SERVICE DOOR INOPERATIVE. REPLACED L2 EMERGENCY OVERHEAD EXIT SIGN LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: PIN — PUSHED OUT (L1 DOOR)
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EVACUATION DOOR MOUNTED SLIDE LIGHT ON FORWARD L1 DOOR INOPERATIVE. INSTALLED PIN ON LIGHT ASSEMBLY WIRE TO SWITCH. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
Part: WIRE — BROKEN (CABIN)
ORD - DURING OVERNIGHT CHECK, DISCOVERED AFT CABIN EMERGENCY EXIT FLOOR PATH LIGHTING INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH WIRE. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
Part: WEB — CRACKED (BS 740)
TUL - NR 2 CENTER WING TANK, SEVERAL BULGES AND CRACKS AT STATION 740 LOWER CHORD, WEB FROM RBL 14 TO RBL 27. INSTALLED DOUBLER REPAIR PER ESO 11782. (M)
Part: RIVET — POPPED (BS 740)
TUL - POPPED RIVET TAIL STATION 740 RBL 3, INSIDE NR 2 TANK CENTER LOWER CHORD AREA. INSTALLED REPAIR DOUBLER PER ESO 11782. (M)
Part: FLOORBEAM — CORRODED (BS 1070)
TUL - BS 1070 RBL 45.5 HEAVY CORROSION ON TOP LEG OF FLOORBEAM. REMOVED CORRODED PORTION OF FLOORBEAM. INSTALLED NEW PORTION PER SRM 53-10-8. (M)
Part: FLOOR SKIN — CORRODED (BS 1176)
TUL - CORROSION ON CHORD AND RT AFT LAV FLOOR SKIN, BS 1176.9 RBL 29-32 WL 208.1. REMOVED CORROSION TREATED AND PRIMED AREA PER MM 51-20-0. INSTALLED DOUBLER ON LAV FLOOR SKIN. (M)
Part: CASTING — CRACKED (WS 243.93)
TUL - FOUND INBOARD AILERON QUADRANT CASTING AND WEB AT CASTING CRACKED. REMOVED AND INSTALLED NEW WEB AND QUADRANT AND CASTING. (M)
Part: EEL CONNECTOR — DEFECTIVE (CABIN)
DFW - DURING OVERNIGHT CHECK, FOUND THE MID CABIN EMERGENCY LIGHT SIGN INOPERATIVE. REPAIRED CONNECTOR, SYSTEM GROUND CHECKED NORMAL OPERATION. (M)