N69SC

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
GULFSTREAM INT'L AIRLINESOperatoron 1992-03-18Operator named in NTSB report
THE SLOSMAN CORPORATIONOperatoron 1982-06-18Operator named in NTSB report

Accident & incident history

Incident · 1992-03-18 Operator named in NTSB report
CESSNA 402C No injuries Part 135GULFSTREAM INT'L AIRLINES

Operated by GULFSTREAM INT'L AIRLINES INC (per NTSB report)

Source: NTSB case MIA92IA100
Accident · 1982-06-18 Operator named in NTSB report
CESSNA 402C No injuries Part 91THE SLOSMAN CORPORATION

Operated by THE SLOSMAN CORPORATION (per NTSB report)

Source: NTSB case ATL82DA172

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

21 reports on file, 1995-09-09 – 2017-09-14.

OTHER · 2017-09-14 Matched by certificate designator
ATA 5743

Part: FITTING — CRACKED (RT MLG) · airframe 33,221 hrs · 35,946 cycles

DURING A ROUTINE INSPECTION, A CRACK WAS DISCOVERED AT THE RT MLG ACTUATOR ATTACH FITTING RWS 88.62. THE CRACK ORIGINATED AT A LOCK FASTENER AND EXTENDED DOWN APPROXIMATED .60 INCH AND UPWARD THROUGH THE UPPER RADIUS OF PART APPROXIMATELY .70 INCH. THE UPPER PORTION OF CRACK WAS NOT VISIBLE UNTIL REMOVED FROM ACFT. THE LWR PORTION OF CRACK WAS CONFIRMED WHEN PAINT AND PRIMER WERE REMOVED. AREAS OF CORROSION COMMON TO SEVERAL FASTENER LOCATIONS, INCLUDING ASSUMED CRACK ORIGIN, WERE IDENTIFIED WHEN COATINGS WERE REMOVED. A RECORDS REVIEW IDENTIFIED THE FITTING IS ORIGINAL TO THE AIRFRAME. ALL FASTENERS WERE DETERMINED TO BE INSTALLED CORRECTLY AND NO ADDITIONAL DAMAGE TO UNDERLYING STRUCTURE WAS IDENTIFIED AFTER PART WAS REMOVED. AREAS OF CORROSION COMMON TO FASTENER LOCATIONS WERE IDENTIFIED WHEN COATINGS WERE REMOVED.

Source: SDR HYIA20171030001
Earlier reports · 1995–2016 · 20 reports

2016

OTHER · 2016-10-30 Matched by certificate designator
ATA 8530

Part: EXHAUST VALVE — DAMAGED (NR 4 CYLINDER) · airframe 32,529 hrs

CYLINDER REMOVED DUE TO LOW COMPRESSION AT INSPECTION; EXHAUST VALVE DISPLAYS EVIDENCE OF HEAT DAMAGE.

Source: SDR HYIA20161108192
OTHER · 2016-09-30 Matched by certificate designator
ATA 8530

Part: EXHAUST VALVE — DAMAGED (NR 6 CYLINDER) · airframe 34,253 hrs

CYLINDER REMOVED DUE TO LOW COMPRESSION AT INSPECTION. EXHAUST VALVE DISPLAYS EVIDENCE OF HEAT DAMAGE.

Source: SDR HYIA20161010170
OTHER · 2016-08-19 Matched by certificate designator
ATA 8530

Part: EXHAUST VALVE — DAMAGED (NR 3 CYLINDER) · airframe 32,371 hrs

CYLINDER REMOVED DUE TO LOW COMPRESSION AT INSPECTION, EXHAUST VALVE DISPLAYS EVIDENCE OF HEAT DAMAGE.

Source: SDR HYIA20160825086
OTHER · 2016-08-19 Matched by certificate designator
ATA 8530

Part: EXHAUST VALVE — DAMAGED (NR 1 CYLINDER) · airframe 32,371 hrs

CYLINDER REMOVED DUE TO LOW COMPRESSION AT INSPECTION; EXHAUST VALVE DISPLAYS EVIDENCE OF HEAT DAMAGE.

Source: SDR HYIA20160825085
SMOKE/FUMES/ODORS/SPARKS · 2016-01-14 Matched by certificate designator
ATA 3397

Part: WIRE — DEFECTIVE (CABIN) · airframe 31,871 hrs · 32,996 cycles

PILOT REPORTED SMOKE IN COCKPIT. PANEL IN FRONT OF EMER EXIT WINDOW WAS GLOWING RED. CORRECTED NON-STANDARD WIRING, BETWEEN THE CLOCK CIRCUIT & THE CABIN LIGHT CB. NO FURTHER DEFECTS NOTED.

Source: SDR HYIA20160121001

2015

OTHER · 2015-07-09 Matched by certificate designator
ATA 5410

Part: BEAM — CRACKED (RT NACELLE) · airframe 31,592 hrs

DURING SCHEDULED INSPECTION, THE LWR U CHANNEL OF RT NACELLE CROSSOVER BEAM, 5654104-12, WAS FOUND TO BE CRACKED, TRANSVERSE TO LENGTH OF CHANNEL THROUGH EACH RADIUS. CORRECTIVE ACTION WILL BE A COMPLETE REPLACEMENT OF BEAM, FOLLOWING A DETAILED INSPECTION OF SURROUNDING STRUCTURE. A SUPPLEMENT ILLUSTRATING DAMAGE AREA WILL BE SUBMITTED.

Source: SDR HYIA07092015001

2013

PARTIAL RPM/PWR LOSS; FLUID LOSS; WARNING INDICATION · 2013-10-01 Matched by certificate designator
ATA 8120

Part: TURBOCHARGER — FAILED (RT ENGINE) · airframe 30,173 hrs · 29,141 cycles

RIGHT ENGINE STEADY, LOSS OF MAP IN CRUISE WITH CORRESPONDING DECREASE IN OIL PRESSURE. ELECTED TO SHUTDOWN AND SECURE RT ENGINE IN FLIGHT AND MADE AN UNSCHEDULED LANDING. DURING INSPECTION, RT ENGINE TURBOCHARGER FOUND TO BE AT FAULT. REPLACED RT TURBOCHARGER, VISUALLY INSPECTED ENGINE AND COMPONENTS FOR ADDITIONAL DEFECTS, AND GROUND RUN ACFT TO VERIFY ENGINE PRODUCES RATED MAP AND DOES NOT LEAK OIL.

Source: SDR HYIA20131003001

2012

OTHER · 2012-11-28 Matched by certificate designator
ATA 3230

Part: DRAG BRACE — CRACKED (NLG) · airframe 2,202 hrs

AT SCHEDULED INSPECTION, NLG DRAG BRACE, PN 5142002-5 WAS FOUND TO BE CRACKED IN THE AREA OF NLG ACTUATOR ATTACH POINT. METHOD OF INSPECTION WAS DYE PENETRANT. THIS CRACK WAS FOUND TO BE BEYOND LIMIT ALLOWABLE OF MEB91-11R1. THIS UNIT HAS BEEN SCRAPPED & A REPLACEMENT DRAG BRACE HAS BEEN INSTALLED IN ACFT.

Source: SDR HYIA20140414031

2011

OTHER · 2011-06-24 Matched by certificate designator
ATA 8530

Part: NUT — CRACKED (NR 3 CYLINDER) · airframe 28,004 hrs

RIGHT ENGINE NR 3 CYLINDER HAS ONE CRACKED HOLD DOWN NUT.

Source: SDR HYIA
OTHER · 2011-04-13 Matched by certificate designator
ATA 3230

Part: DRAG BRACE — CRACKED (NLG) · airframe 27,225 hrs

AT SCHEDULED INSPECTION, NLG DRAG BRACE, OEM PN 5142002-5, WAS FOUND TO BE CRACKED IN THE AREA OF NLG ACTUATOR ATTACH POINT. METHOD OF INSPECTION WAS DYE PENETRANT. THIS CRACK WAS FOUND TO BE WITHIN ALLOWABLE LIMIT. THIS UNIT HAS BEEN REPAIRED IAW PROCEDURE OUTLINED IN MEB941-11R1 & RETURNED TO SERVICE.

Source: SDR HYIA20140415049

2010

SMOKE/FUMES/ODORS/SPARKS · 2010-11-24 Matched by certificate designator
ATA 3110

Part: SWITCH — BURNED (INSTRUMENT LIGHT) · airframe 27,268 hrs

CREW REPORTED ODOR IN COCKPIT. INTIALLY SUSPECTED HEATER, BUT ODOR REMAINED AFTER HEATER WAS TURNED OFF. CREW NOTICED SMOKE COMING FROM INSTRUMENT PANEL LIGHTING SWITCH. TURNED OFF SWITCH, SMOKE STOPPED, LANDED WITHOUT INCIDENT. MX R & R INSTRUMENT PANEL DIMMER ASSY. ACFT RELEASED BACK TO SERVICE.

Source: SDR HYIA69SC1124
OTHER · 2010-08-02 Matched by certificate designator
ATA 3213

Part: AXLE — CRACKED (MLG) · airframe 26,913 hrs

UPON TAXING INTO POSITION TO HOLD FOR TAKEOFF,CREW REPORTED EXPERIENCING TAXIING/ BRAKING DIFFICULTIES. MX FOUND RT MAIN GEAR LOWER BARREL AND AXLE ASSY CRACKED. MX R & R RT MAIN GEAR LOWER BARREL AND AXLE ASSY. ACFT RETURNED TO SERVICE.

Source: SDR HYIA69SCRXL802
SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 2010-02-17 Matched by certificate designator
ATA 2916

Part: SIGHT TUBE — UNSERVICEABLE (HYD RESERVOIR) · airframe 26,372 hrs

CREW REPORTED, DURING CRUISE CONFIGURATION, HYDRAULIC PRESSURE LIGHT ILLUMINATED, FOLLOWED BY WHAT APPEARED TO BE SMOKE COMING FROM UNDER THE INSTRUMENT PANEL. FOLLOWED CHECKLIST TO ALLEVIATE SMOKE FROM CABIN. DIVERTED TO CLOSEST AIRPORT. LANDED WITHOUT INCIDENT. MX INSPECTED ACFT, FOUND HYD RESERVOIR SIGHT TUBE RUPTURED, AND RESERVOIR EMPTY. NO EVIDENCE OF SMOKE OR FIRE WAS FOUND. WHAT WAS THOUGHT TO BE SMOKE BY THE CREW WAS ATOMIZED HYD FLUID FROM RUPTURED SIGHT TUBE. MX REMOVED AND REPLACED SIGHT TUBE, SERVICED RESERVOIR, AND RELEASED ACFT BACK TO SERVICE.

Source: SDR HYIA69SCHYDLK
OTHER · 2010-01-07 Matched by certificate designator
ATA 2460

Part: MASTER SWITCH — UNSERVICEABLE (ELECTRICAL) · airframe 26,242 hrs

PREFLIGHT, CREW REPORTED AVIONICS MASTER SWITCH INOPERATIVE. MX REMOVED AND REPLACED CIRCUIT BREAKER SWITCH. SYS CHECKS OK. ACFT RELEASED BACK TO SERVICE.

Source: SDR HYIA69SC AVMSTR

2008

PARTIAL RPM/PWR LOSS; WARNING INDICATION · 2008-07-11 Unresolved
ATA 2823

Part: SELECTOR VALVE — DAMAGED (LT WING FUEL)

AT CLIMB POWER-RT FUEL FLOW DROPPED TO 90 PPH. AUX PUMP ON LOW FIXED PROBLEM TEMPORARILY. FUEL FLOW DROPPED AGAIN AND LT ENGINE SURGE. RETURNED TO DEPARTURE AIRPORT AND LANDING WITHOUT INCIDENT. MX REMOVED AND REPLACED LT FUEL SELECTOR VALVE. ALSO REPLACED AUX FUEL PUMP AND CROSSFEED VALVE AS A PRECAUTIONARY MEASURE. (A)

Source: SDR YBS2008F00000

2007

VIBRATION/BUFFET · 2007-06-12 Matched by certificate designator
ATA 8530

Part: CYLINDER — FAILED (NR 6) · airframe 23,072 hrs

LEFT ENGINE FAILURE WITH CASE PENETRATION BELIEVED TO BE CAUSED BY A VALVE FAILURE AT THE NR 6 CYLINDER. A TCM ENGINEER WAS ON HAND AT THE TIME AND THE ENGINE HAS BEEN SENT TO TCM FOR TEARDOWN. LEFT ENGINE WAS REMOVED AND REPLACED AS A CORRECTIVE ACTION ON 6/13/2007.

Source: SDR 135N69SC

2006

ELECT. POWER LOSS-50 PC · 2006-07-28 Matched by certificate designator
ATA 2400

Part: CIRCUIT BREAKER — FAILED (COCKPIT)

CREW REPORTED AVIONICS MASTER SWITCH INOP. MX CHANGED CIRCUIT BREAKER SWITCH.

Source: SDR 1350522N69SC

2003

OTHER · 2003-09-11 Matched by certificate designator
ATA 7320

Part: FMU — FAILED (RT ENGINE)

RT ENGINE FAILED TO SHUT OFF IN IDLE CUT OFF. REMOVED AND REPLACED FUEL METERING UNIT AND RELEASED AIRCRAFT BACK TO SERVICE.

Source: SDR HYI2003F00017

2000

OTHER · 2000-06-05 Unresolved
ATA 3230

Part: DRAG BRACE — CRACKED (NOSE GEAR)

ON PRE-FLIGHT, CREW FOUND SUSPECTED CRACK AT DRAG BRACE TO ACTUATOR ATTACH LUG AREA. MAINTENANCE PERFORMED NDT. FOUND TO BE CRACKED AT SUSPECTED AREA. REMOVED AND REPLACED DRAG BRACE AND ROD END (PN ADNE4JW) WITH NEW AND RETURNED AIRCRAFT TO SERVICE. (X)

Source: SDR 20000721SH032

1995

VIBRATION/BUFFET; FLT CONT AFFECTED · 1995-09-09 Unresolved
ATA 2730

Part: ACTUATOR ASSY — FAILED (ELEV PITCH SYST)

MHH/FLL - FLT 446 - AFTER TAKEOFF, THE AIRCRAFT EXPERIENCED A PITCH UP, PITCH DOWN, AND SEVERE VIBRATION. THE AIRCRAFT DIVERTED TO FPO AND LANDED WITHOUT INCIDENT. MAINTENANCE WAS DISPATCHED TO FPO TO REMOVE AND REPLACE THE ELEVATOR PITCH TRIM ACTUATOR. THE ROLL PINS (2) HAD VIBRATED OUT OF THE ELEVATOR PITCH TRIM ACTUATOR.

Source: SDR 95ZZZX5390