N7444U

No registry detail on file · not in current registry

Operators of this aircraft

Who operated this tail, and how firmly we know it.

OperatorRolePeriodBasis
UNITED AIRLINES, INC. (CALA)Operatoron 1979-09-15Operator named in NTSB report

Accident & incident history

Incident · 1979-09-15 Operator named in NTSB report
BOEING 727 Serious injuryUNITED AIRLINES, INC.

Operated by UNITED AIR LINES INC (per NTSB report)

Source: NTSB case CHI79DA080

Maintenance disclosures

Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.

14 reports on file, 1996-01-10 – 2001-02-03.

OTHER · 2001-02-03 Unresolved
ATA 3350

Part: SIGN — MISSING (CABIN) · airframe 61,001 hrs · 35,465 cycles

CENTER AISLE EXIT SIGN IS MISSING. *S/D* AIRCRAFT RETURNED TO GATE BECAUSE FLIGHT ATTENDANT NOTICED CENTER EXIT SIGN WAS MISSING FROM CEILING. REINSTALLED LIGHT ASSEMBLY ABOVE CEILING PANEL. OPERATIONS CHECK NORMAL.

Source: SDR 2001UALA00074
Earlier reports · 1996–2000 · 13 reports

2000

WARNING INDICATION · 2000-10-11 Unresolved
ATA 2782

Part: ACTUATOR — MALFUNCTIONED (SLATS) · airframe 60,383 hrs · 35,094 cycles

ON DEPARTURE FROM PVD, NR 2 LEADING EDGE SLAT REMAINED IN THE EXTENDED POSITION. DIVERTED TO BOSTON. *S/D* FOUND FAILED TAI TELESCOPING DUCT AND RESULTING DAMAGE TO NR 2 L/E SLAT. REPLACED FAILED DUCT AND NR 2 L/E SLAT ASSY PER MAINTENANCE MANUAL. SYSTEM OPS CHECK NORMAL.

Source: SDR 2000UALA00589
NO TEST · 2000-08-01 Unresolved
ATA 3350

Part: RELAY — FAILED (CABIN) · airframe 59,949 hrs · 34,836 cycles

AT DEPARTURE TIME CREW REPORTED EMERGENCY EXIT LIGHTS WOULD NOT EXTINGUISH. *S/D* REPLACED RELAY R70, LIGHTS OPS NORMAL.

Source: SDR 2000UALA00460
NO TEST · 2000-07-11 Unresolved
ATA 3350

Part: BATTERY PACK — INOPERATIVE (CABIN) · airframe 59,865 hrs · 34,787 cycles

INTERIOR EMERGENCY EXIT LIGHTS BOTH FORWARD AND AFT RIGHT HAND OVERWING DOORS ARE INOPERATIVE. *S/D* BATTERY PACK AND BATTERY CARTRIDGE AT STATION 800,OPERATIONAL CHECK OK.

Source: SDR 2000UALA00415
OVER TEMP; WARNING INDICATION · 2000-01-04 Unresolved
ATA 3610

Part: REGULATOR — FAILED (DEICE SYSTEM) · airframe 58,512 hrs · 33,922 cycles

ON CLIMBOUT OF ORD, NR 2 DUCT OVERHEAT OCCURRED WITH ANTI-ICE ON. RETRACTED THROTTLE NR 2 AND DUCT TEMPERATURE REDUCED AND STABLIZED. *S/D* THERMOSTATIC REGULATOR REPLACED.

Source: SDR 2000UALA00013

1999

SMOKE/FUMES/ODORS/SPARKS; WARNING INDICATION · 1999-12-14 Unresolved
ATA 2120

Part: UNKNOWN — SMOKE (CABIN) · airframe 58,364 hrs · 33,826 cycles

ON LANDING WHILE ENGINES WERE IN REVERSE SMOKE APPEARED IN CABIN. ENGINE BLEEDS AND PACKS WERE SHUT OFF PROBLEM WENT AWAY. *S/D* UNKNOWN CAUSE. SEATTLE MAINTENANCE TRIED TO DUPLICATE PROBLEM BY RUNNING ALL ENGINES AND PACKS, AND CYCLEING REVERSERS. PROBLEM COULD NOT BE DUPLICATED.

Source: SDR 99UAL900654
NO TEST · 1999-04-01 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (GALLEY)

OVERHEAD EMERGENCY EXIT SIGN AT AFT GALLEY LOCATION IS INOP. REPLACED BATTERY PACK, CHECKS NORMAL.

Source: SDR 99UAL900185

1997

FLT CONT AFFECTED · 1997-08-05 Unresolved
ATA 2210

Part: YAW DAMPER — FAILED (E/E COMPT)

THREE UNCOMMANDED RUDDER KICKS TO THE LEFT. APPEARS TO BE BOTH UPPER AND LOWER RUDDERS. HAPPENED ONLY AT 30,000 FEET. *S/D* REPLACED YAW DAMPER COUPLER AND SYSTEM CHECKED OK.

Source: SDR 97UAL900600

1996

FLUID LOSS · 1996-12-31 Unresolved
ATA 2810

Part: CHECK VALVE — BROKEN (RT WING)

CREW REPORTED FUEL ALL OVER THE RAMP AFTER HOSE DISCONNECTED FROM AIRCRAFT. *S/D* MAINTENANCE FOUND FILL CONNECTION CHECK VALVE MISSING. REMOVED ELBOW, BROKEN PIECES AND INSTALLED POPPET VALVE.

Source: SDR 96UAL901010
OTHER · 1996-12-06 Unresolved
ATA 2565

Part: INFLATION TUBE — LEAKING (DOOR SLIDE)

SLIDE REMOVED PER AIR CRUISERS SERVICE INFORMATION LETTER 25-98. DURING SHOP OVERHAUL A SEAM LEAK DEVELOPED ON THE INFLATION TUBE. SLIDE SCRAPPED.

Source: SDR 96UAL900921
OTHER · 1996-06-24 Unresolved
ATA 2820

Part: FUEL VENT TUBE — BROKEN (NR 1 FUEL TANK)

NUMBER 1 MAIN FUEL QUANTITY INOPERATIVE, GAUGE ERRATIC, ROLLS UP AND DOWN. CROSS-FEED OPEN, NR 2 MAIN PUMPS ON AND NR 1 PUMPS OFF. *S/D* MAINTENANCE REMOVED BROKEN VENT ELBOW IN NR 1 TANK, HAD ELBOW WELDED AND IT WAS REINSTALLED AND LEAK CHECKED OKAY.

Source: SDR 96UAL900481
NO TEST · 1996-05-30 Unresolved
ATA 2611

Part: SMOKE DETECTOR — DAMAGED (RT LAV)

LAVATORY SMOKE ALARM DISCONNECTED IN FORWARD RIGHT HAND LAVATORY. *S/D* THE CAUSE OF THE FORWARD RIGHT HAND LAVATORY SMOKE DETECTOR BEING DISCONNECTED IS UNKNOWN. A NEW DETECTOR WAS INSTALLED AND IT CHECKED OK.

Source: SDR 96UAL900381
NO TEST · 1996-01-15 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (CABIN)

EMERGENCY LIGHT JUST FORWARD OF FORWARD GALLEY ON THE CEILING OVER THE AISLE IS INOPERATIVE. REPLACED WEAK BATTERY PACK.

Source: SDR 96UAL900032
NO TEST · 1996-01-10 Unresolved
ATA 3350

Part: BATTERY PACK — DISCHARGED (AFT ENTRY DOOR)

AFT ENTRY DOOR EMERGENCY EXIT SLIDE LIGHT INOPERATIVE. REPLACED BATTERY PACK.

Source: SDR 96UAL900025