N769UA
Registered owner: UNITED AIRLINES INC, IL (owner ≠ operator)
Operators of this aircraft
Who operated this tail, and how firmly we know it.
| Operator | Role | Period | Basis |
|---|---|---|---|
| UNITED AIRLINES, INC. (CALA) | Operator | on 2026-10-21 | Operator named in NTSB report |
Accident & incident history
Operated by UNITED AIRLINES INC (per NTSB report)
Not yet finalized — may be revised.Maintenance disclosures
Service Difficulty Reports filed with the FAA for this airframe. Filing is largely voluntary — the number of reports is not a measure of reliability. To verify a report, search its control number at the FAA SDRS site.
228 reports on file, 1995-07-17 – 2026-10-03.
Part: LIGHT — DETACHED (ZONE 200) · airframe 111,757 hrs · 20,492 cycles
EMERGENCY PATH LIGHT NEA R SEAT 24D IS LOOSE AND HANGING. SECURED LOOSE EMERGENCY LIGHT AT. 24D WITH TAPE. APPLIED MEL REPLACED EPL HOUSING, IAW CMM 25-21-56. OPS CHKD GOOD
Part: UNKNOWN — ODOR (CABIN) · airframe 111,743 hrs · 20,490 cycles
SMOKE ODOR CONDITIONAL INSP REQUIRED PER AMM 05-51-XX DUE TO AN INCIDENT REPORTED BY THE CREW.SLIGHT ELEC ODOR NOTICED BY THE FLIGHT ATTENDANTS BY MID GALLEY AT GATE. PERFORMED A VISUAL INSPECTION OF THE MID GALLEY AND BUSINESS CLASS CABIN PER REFERENCE TASK 05-51-58-800-801-C3, INCLUDING OVENS, COFFEE MAKERS, WARMER, CIRCUIT BREAKERS, IN-FLIGHT ENTERTAINMENT, POWER OUTLETS, AND CABIN LIGHTS. THE MONITORS AND POWER OUTLETS AT SEATS 3D AND 3E HAVE BEEN DEFERRED UNDER MEL/NEF. NO OTHER FAULTS WERE NOTED AT THIS TIME. OPERATIONAL CHECK SATISFACTORY.OKAY TO CONTINUE.
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 3R POWER SUPPLY M33404 REF TO HAECO NON-ROUTINE NO.9453344, REPLACED POWER BATTERY PACK AT DOOR R3 (M33404) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 2L POWER SUPPLY M33096 REF TO HAECO NON-ROUTINE NO.9455173, REPLACED POWER BATTERY PACK AT DOOR L2 (M33096) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 1L POWER SUPPLY M33424 REF TO HAECO NON-ROUTINE NO.9455172, REPLACED POWER BATTERY PACK AT DOOR L1 (M33424) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 1L POWER SUPPLY M33093 REF TO HAECO NON-ROUTINE NO.9453342, REPLACED POWER BATTERY PACK AT DOOR L1 (M33093) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 3L POWER SUPPLY M33406 REF TO HAECO NON-ROUTINE NO.9453343, REPLACED POWER BATTERY PACK AT DOOR L3 (M33406) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 4L POWER SUPPLY M33407 REF TO HAECO NON-ROUTINE NO.9453345, ORIGINATED BY EMP V905359, 86-3350-1-0002 PERFORMED BY EMP V905359 AND IDT BY EMP V903667 - REPLACED POWER BATTERY PACK AT DOOR L4 (M33407) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 110,351 hrs · 20,203 cycles
THE EMERGENCY LIGHT BATTERY PACK DEEP CYCLE CHECK FOUND BATTERY LOW ON THE DOOR 4R POWER SUPPLY M33409 REF TO HAECO NON-ROUTINE NO.9455174, REPLACED POWER BATTERY PACK AT DOOR R4 (M33409) AND PERFORMED INSTALLATION TEST WAS NORMAL PER AMM 33-51-06-960-802 REV 106
Part: BATTERY PACK — DISCHARGED (ZONE 200) · airframe 109,709 hrs · 20,059 cycles
POWER SUPPLY - BATTERY PACK CAPACITY CHECK PROCEDURE - 4, PROXIMITY LIGHTS LT & RT AND 4 MAIN AISLE RT SIDE SEAT ROWS 33 TO 36. AND 3 MAIN AISLE LIGHTS LEFT SIDE IN FIRST CLASS DID NOT STAY ILLUMINATED AT LEAST 15 MIN DURING TEST. REPLACED THE BATTERY PACK FOR POWER SUPPLY M33404 & BATTERY PACK AT POWER SUPPLY M33424 IAW AMM 33-51-06. OPS CHECKED GOOD.
Earlier reports · 1995–2025 · 218 reports
2025
Part: FITTING — OUT OF ADJUST (GIRT BAR) · airframe 109,270 hrs · 19,969 cycles
R4 DOOR, NOT ABLE TO OPEN FROM OUTSIDE & INSIDE WHILE TROUBLESHOOTING, ARMING HANDLE WILL NOT FULLY DISARM. WHEN IN DISARM POSITION GIRT BAR IS NOT FULLY CAPTURED CREATING BINDING PREVENTING DOOR FROM OPENING. DOOR OPENS NORMALLY WHEN GIRT BAR IS NOT ATTACHED. UPON FURTHER INSPCTION, FOUND GIRT BAR MECHANISM IS NOT FULLY DISARMING ON AFT FLOOR FITTING. FOUND PLAY WITH TORQUE TUBE HOOK MECHANISM AND FLOOR FITTING. ADJUSTED BOTH FWD AND AFT FLOOR GIRT BAR FITTINGS. OP CHECKED GOOD. IAW AMM 52-00-00-001, INSPECTED GIRT BAR FITTINGS VERIFIED PINS REMOVED AND DOOR OPS CHKD OK.
Part: ELEC CONNECTOR — FAULTED (ZONE 200) · airframe 108,771 hrs · 19,856 cycles
EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - FLOOR PROXIMITY LIGHTS ON CENTER SEAT ROWS 25DEFG TO 32DEFG INOPERATIVE FOUND DAMAGED EMERGENCY LIGHT CONNECTOR PLUG UNDER SEAT G25. REPLACED PLUG AT LOCATION, REF WDM 33-51-64 AND SWPM 20-61-28. OP CHECK GOOD.
Part: WARNING MESSAGE — FALSE ACTIVATION (ZONE 800) · airframe 108,351 hrs · 19,762 cycles
DOOR FLIGHT LOCK 3R EICAS STATUS R3 DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SENSOR DISAGREEMENT.DB PSEU 2 (R2) DB PSEU 2 (L2) PERFORMED FIM 52-11 TASK 806. GROUND TEST PASSED. DOOR.LOCKS. OPS CHECK GOOD, DOOR DOES NOT LOCK DUE TO MEL LP 6168339.
Part: WARNING MESSAGE — ILLUMINATED (ZONE 800) · airframe 108,306 hrs · 19,752 cycles
DOOR FLIGHT LOCK 3R EICAS STATUS R3 DOOR FLIGHT LOCK COMMAND, FLT LK RELAY & SENSOR DISAGREEMENT. MESSAGE IS NOT LATCHED, NO HISTORY, OK PER FIM 52-11-TASK 806 ITEM #E.
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 108,011 hrs · 19,694 cycles
R4 DOOR AREA INTERNAL EMERGENCY LIGHT DIM. M33408 BATTERY FAILED. REPLACED THE M33408 BATTERY PACK AT R 4 AND FUNCTION TEST NORMAL IAW AMM 33-51-06-960-802 REV.104.
Part: BATTERY PACK — NO TEST (ZONE 200) · airframe 108,011 hrs · 19,694 cycles
R3 DOOR AFT EMERGENCY EXIT IDENTIFIER DIM. M33401 BATTERY FAILED. REPLACED THE M33401 BATTERY PACK AT R 3 DOOR AND FUNCTION TEST NORMAL IAW AMM 33-51-06-960-802 REV. 104.
2024
Part: ANTI-ICE VALVE — FAULTED (NR 2 ENGINE) · airframe 106,017 hrs · 19,240 cycles
ICING ENG EICAS CAUTION PRIMARY ICE DETECTION SYSTEM (LEFT OR RIGHT ICE DETECTORS) DETEC TS ICE, AND LEFT AND/OR RIGHT ENGINE ANTI-ICING SWITCH IS OFF. CAUTION LVL ADVISORY DURING CLIMB IN IMC. EXTINGUISHED EVENTUA LLY REPLACED RH EAI VLV REF AMM TASK 30-21-02-400-806-003. ACP ANTI-ICE ( ENG RUNNING) SYS TEST. REF AMM TASK 30-21-00-730-806-003. TEST PASSED. OK TO CONTINUE PARTS USED: 1332080,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1332080 SN OFF 0412 VALVE, ANTI-ICE OFF 25-3021-9-0001 0412 ON 25-3021-9-0001 7010
Part: FAIRING — BROKEN (ZONE 500) · airframe 105,449 hrs · 19,101 cycles
UPON WALKAROUND FOUND PANEL 193DL MISSING ABOVE LH WING PART NIS IAD. PARTS UPDATED IN MATERIALS. MORE ITEMS ADDED TO MATERIALS AS PRECAUTIONARY. ALSO REQUIRES 12 EA BACB30LH3-5 (BOLTS), CANNOT ADD MORE ITEMS INTO MATERIALS. GVI OF THE PANEL ATTACH BRACKETS, FUSELAGE, AND HORIZONAL STAB MATCH DRILLED AND COUNTERSUNK REPLACEMENT FAIRING TO AIRCRAFT WAS PERFORMED ON LOG #9678178. REF SRM 51-40-05 AND 51-40-08. INSTALLED NEW WING TO BODY FAIRING PANEL (139DL). REF: AMM 53-46-01-400-801
Part: FAIRING — DAMAGED (ZONE 100) · airframe 105,445 hrs · 19,100 cycles
UPON WALKAROUND FOUND PANEL 193DL MISSING ABOVE LH WING PART NIS IAD. PARTS UPDATED IN MATERIALS. MORE ITEMS ADDED TO MATERIALS AS PRECAUTIONARY. ALSO REQUIRES 12 EA BACB30LH3-5 (BOLTS), CANNOT ADD MORE ITEMS INTO MATERIALS. GVI OF THE PANEL ATTACH BRACKETS, FUSELAGE, AND HORIZONAL STAB WAS PERFORMED ON LOG #9678178. MATCH DRILLED AND COUNTERSUNK REPLACEMENT FAIRING TO AIRCRAFT REF SRM 51-40-05 AND 51-40-08. INSTALLED NEW WING TO BODY FAIRING PANEL (139DL). REF: AMM 53-46-01-400-801
Part: SKIN — CRACKED (BS 2195.75) · airframe 103,098 hrs · 18,554 cycles
EA 5300-01986 REV A OP.001 ( AD 2008- 16-12 ) FX SKIN STA 2195.75 STR 6L-7L 1EA CRACK FOUND NOT MORE THAN 1 INCH CREATE OP.007 FOR REPAIR , TASK TRANSFER TO WO.2724398. FUSELAGE SKIN REPAIRED AS PER EA5300-01986 REV A OP007 AND ECRA 5385-01016 REV - JUST AT STA2195.75 BETWEEN STR5L AND STR10L.
Part: SKIN — DEFORMED (AFT CARGO DR) · airframe 103,098 hrs · 18,554 cycles
SUPPORT TASK - AFT CARGO COMPT DOOR AFT LOWER CORNER EXISTING REPAIRED DOUBLER FOUND DEFORM TRANSFER REF HXWO 2713494 AND AFT CARGO COMPT DOOR AFT LOWER CORNER REPAIRED AS PER SRM52-30-01-2R17 REPAIR 17 FIG.202 , ATTACH FORM 44-0008 WORKSHEET ITEM 1 TO 20.
2023
Part: TIRE — DAMAGED (RT MLG) · airframe 100,298 hrs · 17,858 cycles
#12 RT MAIN GEAR AFT OB TIRE WHEEL ASSY HAS DAMAGE . UPON ARRIVAL RAMP REPORTED FIRE COMING FROM UNDER DAMAGED HUB CAP. BRAKE ASSY AND TIRE ASSY ARE TILTED IB AT TOP. FIRE DEPT RESPONDED AND PUT OUT FIRE COMING FROM INSIDE AXLE. AXLE AND WHEEL NUT HAVE MELTED AND ARE NOW OVAL SHAPED. NEEDS NEW AXLE. FLAGGED AS AN SDR EVENT REPLACED MLG TIRE AT POSITION 12. PLEASE REF LOG PAGE 3694294 FOR CORRECTED ACTION. AMM 32-45-01.
2022
Part: APU — CONTAMINATED (COCKPIT) · airframe 100,040 hrs · 17,780 cycles
CAPT REPORTED SMOKE IN COCKPIT AND AFT GALLEY. AIR RETURN. CREW NOTICED THE ODOR & TURNED APU BLEED OFF, APU WAS NOT RUNNING. C BLEED AIR ISLN IAW 49-10 TASK 808 SMOKE INSPECTION PERFORMED APU INSPECTION. ONCE IN COCKPIT, NOTICED PACKS, STRONGER. ONCE AT CRUISE ALTITUDE, F/A IN AFT GALLEY VALVE OFF, L PACK OFF, L TRIM AIR OFF. NOTICED THE AMM 49-21-00 UP TO STEP B)3)B, FOUND OIL CONTAMINATION AT AIR APU BLEED WERE OFF. HE CYCLED APU BLEED AND BOTH PACKS TO ON. HE REPORTED SMELL AND A CLEAR/WHITE HAZE IN THE AIR. FIRST OFFICER SMOKE/SMELL STARTED TO DISSIPATE. WE WERE ABLE TO DUPLICATE. REPLACED APU
Part: CTC — UNCONTROLLABLE (ZONE E CABIN) · airframe 99,810 hrs · 17,717 cycles
ZONE E CABIN TEMP UNCONTROLLABLE, WITH TRIM AIR ON TEMP IS 55-60 F WHILE FWD CABIN IS TOO HOT LOCKED . REMOVED AND REPLACED LEFT CTC P# 810200-3 S# 98064644 OFF P# TEMP CONTROLER OPS NORMAL AT THIS TIME. NOTE CTC WAS CHANGED DUE 810200-3 S# C96080208 ON IAW AMM 21-61-01. INSTALLED CTC OPC P# TO POSSIBLY BAD FROM STOCK CAUSING NEW TEMP FAULTS PARTS 2173BCG015-13 ONTO CHANNELS A AND B.
Part: SENSOR — FAILED (ENG #2) · airframe 98,936 hrs · 17,499 cycles
RIGHT ENG FUEL FLTR EICAS. AHM DID NOT EVEN PICK UP . FILTER MSG LATCHED. NOT ACTIVE FOUND DIFFERENTIAL PRESSURE SWITCH S73001 PIN "A" SHORT TO ERASED MSG POWERED EEC PICKED UP MSG 73-60922. ACTIVE WHEN EEC GROUND 2 OHMS. NEEDS NEW SWITCH WDM 73-34-71-1 POWERED VERIFIED MALFUNCTION IS IN THE ALERTING SYSYTEM.FUEL DRAINED NO APPLIED MEL, SWITCH NEEDED P/N 42D395 NOT STOCKED AT STATION. CONTAMINANTS FOUND. WILL ALSO NEED 2 PACKINGS, M25988-1-010. TOMC APPROVES THE MEL 7334B RIGHT ENG FUEL FLTR EICAS. VERIFIED DP SWITCH IS BAD. RPL DIFF PRESS SWITCH REF AMM 73-34-01, DRY MOTOR ENG NO LEAKS. THIS REQUIRES ENG RUN TEST #3 FOR LEAK CHECK ANDVOPS CHK. THRUST "REG ENGINE RUN." REV CLSD FOR ENGINE RUN. ACOMPLISHED 5 MIN IDLE LEAK CHECK . MSG 73-60922 NOT ACTIVE ON MAT . LEAK CHECK GOOD CLOSED COWLS
2021
Part: FILTER — LEAKING (HYD SYSTEM) · airframe 98,927 hrs · 17,495 cycles
LEAK AND OPS CHECK DUE ON LEFT SYSTEM HYDRALIC DUE TO FILTERS BEING CHANGED. LEAK AND OPS CHECKED LEFT HYDRAULIC FILTER.OPS HECKED GOOD
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33404 RESTORE FAIL R EFER TO NR LP:9130256 M33404 EMER LT BATT PACK REPLACED AND TESTED NORMAL AS PER AMM 3 3-51-06 ADD EMP:V920570 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33093 RESTORE FAIL R EFER TO NR LP:9130252 M33406 EMER LT BATT PACK REPLACED AND TESTED NORMAL AS PER AMM 3 3-51-06 ADD EMP:V920570 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 EMER LT BATTERY PACK M33409 RESTORE FAIL REFER TO NR LP:9130264 EMER LT BATTERY M33409 BATTERY PACK REPLACED AND INSTALLATION TE ST NORMAL IAW AMM 33-51-06 ADD EMP:V920595 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33424 RESTORE FAIL REFER TO NR LP:9130255 EMER LT BATTERY M33409 BATTERY PACK REPLACED AND INSTALLATION TE ST NORMAL IAW AMM 33-51-06 ADD EMP:V920595 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33405 RESTORE FAIL R EFER TO NR LP:9130257 M33406 EMER LT BATT PACK REPLACED AND TESTED NORMAL AS PER AMM 3 3-51-06 ADD EMP:V920570 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33408 RESTORE FAIL R EFER TO NR LP:9130262 EMER LT BATTERY M33409 BATTERY PACK REPLACED AND INSTALLATION TE ST NORMAL IAW AMM 33-51-06 ADD EMP:V920595 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33406 RESTORE FAIL R EFER TO NR LP:9130259 M33406 EMER LT BATT PACK REPLACED AND TESTED NORMAL AS PER AMM 3 3-51-06 ADD EMP:V920570 IDT BY HX 147282, APPROVED
Part: BATTERY — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33407 RESTORE FAIL R EFER TO NR LP:9130268 EMER LT BATTERY M33409 BATTERY PACK REPLACED AND INSTALLATION TE ST NORMAL IAW AMM 33-51-06 ADD EMP:V920595 IDT BY HX 147282, APPROVED
Part: BATTERY PACK — FAILED (EMERGENCY LIGHTS) · airframe 98,909 hrs · 17,491 cycles
B777-33-3-7019 CABIN- EMER LT BATTERY PACK M33094 RESTORE FAIL R EFER TO NR LP:9130254 EMER LT BATTERY M33409 BATTERY PACK REPLACED AND INSTALLATION TE ST NORMAL IAW AMM 33-51-06 ADD EMP:V920595 IDT BY HX 147282, APPROVED
Part: PRESSURE DECK — CRACKED (FUSELAGE) · airframe 98,909 hrs · 17,491 cycles
AD 2001-18-09 SUPPORT TASK EA 5300-01502 REV A OP 1 - HORIZONTAL PRESSURE DECK WEB FOUND 6EA CRACKS AS MARKED, DETAILS REFER ATTACHED FIGURE. PLEASE PRINT AND ACCOMPLISH OP 02 FOR MODIFICATION. REF NR LP 9130415. HORIZONTAL PRESSURE DECK WEB 6EA CRACKED AREA TRIMMED OUT AS PER EA 5300-01502 REV A OP 002 AND DRAWING 624W0008 SHEET 8, HFEC INSP CARRIED OUT AS PER B777 NTM PART 6 51-00-01 PROC 2 REV 78, DATE: MAR 01/2020, RESULT: CRACK FREE, PLUG FABRICATED AND INSTALLED AS PER EA 5300-01502 REV A OP 002 AND DRAWING ADD EMP:V923418 624W0008 SHEET 2, EA 5310-01502 REV A OP 002 ACCOMPLISHED. RII INSPECTION DONE BY HX179805.
Part: SKIN — CRACKED (FUSELAGE) · airframe 98,909 hrs · 17,491 cycles
AD 2008-16-12 SUPPORT TASK - EA 5300-01986 OP5 RH STATION 2221.65 BETWEEN STRINGER 5 & 10,1EA FASTENER FOUND CRACK AT RH STA 2221.65 BETWEEN STR 9 & 10. REF NR LP 9130148. FUSELAGE RH STA 2221.65 BETWEEN STR 9 AND STR 10 CRACKED SKIN CUT AND REMOVED AS PER EA 5300-01986 REV A OP 005 STEP 6.0, HFEC INSPECTION CARRIED OUT AS PER B777 NTM PART 6, 51-00-00 PROC 2 AND 51-00-02 PROC3, 51-00-07 REV 78, MAR 01/2020, RESULT: CRACK FREE, EA 5300-01986 REV A OP 011 ACCOMPLISHED. ADD EMP:V896888 RII INSPECTION DONE BY HX146606.
Part: SKIN — CRACKED (FUSELAGE) · airframe 98,909 hrs · 17,491 cycles
AD 2008-16-12 SUPPORT TASK EA 5300-01986 OP 4 RH STA 2195.75 BETWEEN 5 & 10, 1EA FASTENER FOUND CRACK AT RH STATION 2195.75 BETWEEN STR 7 & 8. ACCOMPLISH REPAIR PER OP 004 STEP 6.0. REF NR LP 9130150. FUSELAGE RH STA 2195.75 BETWEEN STR 7 AND STR 8 CRACKED SKIN CUT AND REMOVED AS PER EA 5300-01986 REV A OP 004 STEP 6.0, HFEC INSPECTION CARRIED OUT AS PER B777 NTM PART 6, 51-00-01 PROC 2 AND 51-00-02 PROC 3, 51-00-07, REV 78, MAR 01/2020, RESULT: CRACK FREE, EA 5300-01986 REV A OP 010 ACCOMPLISHED. ADD EMP:V896888 RII INSPECTION DONE BY HX146606.
2020
Part: GUIDE VANE — DAMAGED (NR 2 ENG FAN) · airframe 97,695 hrs · 17,144 cycles
PDA 2 FAN EXIT VANE ASSY DAMAGED AT THE 2 O`CLOCK POSITION OF NR 1 ENG, LOWER PORTION DEPARTED ENGINE REMOVED THE BROKEN FEGV ON NR 1 ENGINE IAW AMM 72-33-02. PERFORMED STEP 2 OF ECRA 7200-05592 REV A. UPON PERFORMING STEP 2 ANOTHER FEGV. FOUND DAMAGED. IT WAS REMOVED IAW AMM 72-33-03-200-801-N01. REMOVED TWO BROKEN FAN EXIT GUIDE VANES ADJACENT TO EACH OTHER AT THE 2 O''CLOCK POSITION. NEED TO HAVE ENGINE REMOVED WITHIN 2 CYCLES. AS PER ECRA 7200-05592 REF ECRA 7200-05592A ACCOMPLISH INTERIM REPAIR FOR MX FERRY TO REPAIR FACILITY WHERE ENG REPLACMENT CAN BE ACCOMPLISHED. WITHIN 2 CYCLES.
2018
Part: BEAM — CRACKED (BS 1715) · airframe 89,450 hrs · 15,459 cycles
AFT CARGO DOOR UPPER INTERNAL FRAME, UPPER SURFACE HAS A DENT AT BS 1715 WITH EVIDENCE OF A CRACK AT THE INBOARD RADIUS. REPAIRED IAW ECRA 5230-02054, PART 1, AND ECRA 5230-02054, PART 1, ITEM 2.
Part: SKIN — CHAFED (FUSELAGE) · airframe 89,448 hrs · 15,458 cycles
RIGHT FUSELAGE STA 2110-2121 STR2R FND CHAFING. CARRIED OUT REPAIR AS PER EC/RA 5330-06315.
Part: SKIN — CHAFED (FUSELAGE) · airframe 89,448 hrs · 15,458 cycles
LEFT FUSELAGE SKIN STA2110-2120 STR2L FND CHAFING. LEFT FUSELAGE SKIN STA2110-2120 STR 2L REPAIRED AS PER SRM 53-70 -01 REPAIR 2 REV 75 AND ECRA 5330-06315.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHT) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CPACITY CHECK, FOUND THE R4 DOOR BATTERY PACK INOPERATIVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960-802, REV 81.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND THE L2 DOOR BATTERY INOPERATIVE. THE BATTERY PACK WAS REPLACED. OP TESTED NORMAL IAW AMM 33-51-06-960-802, REV 81.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND THE BATTERY INOPERATIVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960-8 02, REV 81.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND THE BATTERY INOPERATVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960- 802, REV 81.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 89,448 hrs · 15,458 cycles
AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND THE R4 DOOR BATTERY PACK INOPERATIVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960-802, REV 81.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND THE L4 DOOR BATTERY PACK INOPERATIVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960-802, REV 81.
Part: BATTERY PACK — NO TEST (EMERGENCY LIGHTS) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND L2 DOOR BATTERY PACK INOPERATIVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960-802, REV 81.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHT) · airframe 89,448 hrs · 15,458 cycles
DURING AN EMERGENCY LIGHT BATTERY PACK CAPACITY CHECK, FOUND THE BATTERY INOPERATIVE. THE BATTERY PACK WAS REPLACED. OPS TESTED NORMAL IAW AMM 33-51-06-960-8, 02, REV.81
Part: SIGN — CRACKED (CABIN) · airframe 89,448 hrs · 15,458 cycles
SPEC NO.B777-53-3-6219 - DOOR 1R, 2L, 3R, 4R AFT EMERGENCY EXIT IDENTIFIERS BASE FOUND CRACK MARK. THE DEFECTIVE EXIT IDENTIFIERS REPLACED THE LIGHT TEST PERFORMED AND THE RESULT WAS NORMAL AS PER AMM 33-51-01-960-802 REV.81.
Part: STRINGER — CRACKED (BS 265) · airframe 89,448 hrs · 15,458 cycles
MAIN DECK, BS 265, STRINGER 27R, CRACKED AROUND FASTENER HEAD. THE STRINGER WAS REPAIRED IAW SRM 53-10-03, REPAIR 5, FIG 201, REV 75.
2017
Part: BRACKET — BROKEN (FLASHLIGHT) · airframe 89,260 hrs · 15,426 cycles
EMERGENCY FLASHLIGHT HOLDER BROKEN AT DOOR 3R. FLASHLIGHT CRADLE HAS ONE CLIP BROKEN AT 3R. REMOVED AND INSTALLED NEW EMERGENCY FLASHLIGHT BRACKET REF AMM 25-00-00
Part: LAMP — INOPERATIVE (L3 DOOR SLIDE) · airframe 88,564 hrs · 15,281 cycles
L3 DOOR SLIDE EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMP IAW 33-40-00. OPS CHECKED GOOD.
Part: FLASHLIGHT — NOT SEATED (R4 DOOR AREA) · airframe 87,121 hrs · 14,989 cycles
R4 DOOR, F/A FLASHLIGHT INOPERATIVE. SEATED THE FLASHLIGHT. FLASHLIGHT TESTED NORMAL.
Part: ELECTRICAL BOX — FAILED (SEAT 32G) · airframe 86,353 hrs · 14,812 cycles
ELECTRIC IFE/SEATS SWITCH WAS TURNED OFF. DUE TO PAX SEAT AT 32G BEING HOT, FOUND DC ELECTRIC BOX FAULTY. VERIFIED AS SOURCE OF SMOKE ODOR IN CABIN. CONFIRMED FAULT, REMOVED AND REPLACED SEAT 32DEFG DC-SEB IAW AMM 23-32-87. REMOVED AND REPLACED SEAT 32DEFG SPM IAW AMM 23-81-04. REMOVED AND REPLACED SEAT 32DEFG DPCU IAW AMM 23-32-50. SEAT 30DEFG THRU 32DEFG ALL OPS CHECKED NORMAL.
Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
BATTERY CHARGER DISCHARGED. THE BATTERY CHARGER WAS REPLACED AND TEST NORMAL IAW AMM 33-51-00.
Part: CHARGER — INOPERATIVE (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
M33400 BATTERY PACK CHARGER INOPERATIVE. THE CHARGER WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-00.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
BATTERY PACK M33400 DISCHARGED. BATTERY PACK REPLACED AND TESTED NORMAL IAW AMM 33-51-00
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
BATTERY PACK FOUND DISCHARGED. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-00.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
BATTEY PACK DISCHARGED. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-00.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHT) · airframe 86,083 hrs · 14,748 cycles
BATTERY PACK DISCHARGED. THE BATTERY PACK WAS REPLACED AND TEST NORMAL IAW AMM 33-51-00.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
BATTERY PACK DISCHARGED. THE BATTERY PACK WAS REPLACED AND TESTED NORMAL IAW AMM 33-51-00.
Part: BATTERY PACK — DISCHARGED (EMERGENCY LIGHTS) · airframe 86,083 hrs · 14,748 cycles
AFTER POWER RESUME EMERGENCY LIGHT OP TEST FOUND ZONE 1 RT EXIT IDENTIFIER DIM, ZONE 1. RT BATTERY PACK REPLACED AND EXIT IDENTIFIER LAMP TESTED NORMAL IAW AMM 33-51-00
Part: LIGHT — CRACKED (LAVATORY) · airframe 86,083 hrs · 14,748 cycles
LAVATORY 3A-LC EMERGENCY LIGHT SURROUND FOUND CRACKED IN FOUR PLACES. REPLACED AND TESTED NORMAL IAW AMM 33-51-00
2016
Part: OVEN — FIRE (GALLEY) · airframe 84,459 hrs · 14,512 cycles
OVEN FIRE IN "B" GALLEY. FLAMES IN BACK OF OVEN CONTAINED WITH DOOR CLOSED. R & R OVEN AND CONNECTOR INSPECTION ACCOMPLISHED OK.
2015
Part: PUMP — LEAKING (HYDRAULIC SYS) · airframe 81,080 hrs · 14,041 cycles
LEFT HYD SYS RESERVOIR QTY LOW, QTY < .40 ADVISORY MSG 01. ACTIVE CRUISE HARD, RESERVOIR LT FLUID QTY IS LOW. DB HYD INTERFACE MODULE, HYDIM LT MSG 02. ACTIVE CRUISE HARD, RESERVOIR LT FLUID QTY IS LOW. MSG 2910340 ACTIVE ER HARD. FOUND LT EDP HYD PUMP LEAKING. REPLACED PUMP IAW MM 29-11-05. NO OTHER LEAK PRESENT. SYS TESTED NORMAL ON ENG RUN.
Part: DOOR — DEFORMED (CARGO BAY) · airframe 79,437 hrs · 13,823 cycles
AFT CARGO DOOR AFT LOWER CORNER FOUND DEFORMED. PERMANENT REPAIR ACP IAW SRM 52-30-01 REPAIR 17.
Part: DOOR — DENTED (CARGO BAY) · airframe 79,437 hrs · 13,823 cycles
DENT FWD CARGO DOOR FWD EDGE AREA. MEASUREMENTS IN INCHES DEPTH .230, LENGTH 4.168, & WIDTH 1.067. NO VISUAL CRACKS, SLIGHT GOUGE .019 DEEP. PERMANENT REPAIR ACP IAW SRM52-30-01 REPAIR 17.
2014
Part: UNKNOWN — ODOR (CABIN) · airframe 74,620 hrs · 13,174 cycles
CREW REPORTS ELECTRIC SMELL AT SEATS 8CD & VIDEOS TURNED OFF. FLIGHT ATTENDANT TRIED RESET, NO HELP. ACCOMPLISHED FIM 21-00T808 PARTS J & K FOR CABIN ELECTRIC SMELL. RESET IFE SYS, VIDEO & HANDSETS AT SEATS 8CD INOPERATIVE. DISCONNECTED CONNECTORS AT PANASONIC S EB BEHIND SEAT 8C.
Part: WARNING MESSAGE — ACTIVATED (COCKPIT) · airframe 74,518 hrs · 13,158 cycles
AUTO SPEED BRAKE EICAS MESSAGE DISPLAYED ON BRAKE RELEASE, FAILED MAT TEST. COMPLIED WITH MEL 2762A, CBS PULLED & COLLARED ON LT & RT PSA IAW MEL 2762A.
2013
Part: UNKNOWN — VIBRATION (CABIN) · airframe 74,194 hrs · 13,107 cycles
FLOOR AREA IN ROW 22 - 24 RT SIDE VIBRATES. TURNED OFF LOWER RECIRCULATING FAN & ACCOMPLISHED VISUAL INSPECTION AT RT AC BAY PACK COMPONENTS INCLUDING ALL SUPPORTS BRACKETS, RAM AIR INLET IAW AMM 21-52-20-401, MT21-UA7 & AT FWD BULK PIT AFT WALL AIR PLENUM, RECIRCULATING FAN & SURROUNDING STRUCTURES, NO DEFECTS NOTED. CHECKED SEAT ROWS 22 - 24 AT RT SIDE FOR SECURITY AT FLOOR ATTACHMENTS.
Part: DUCT — DAMAGED (CABIN) · airframe 74,163 hrs · 13,103 cycles
HOT AIR AT SEAT 10A ZONE C IS AT 88 DEGREES. DUCT PRESS FLUCTUATES. SEE SEQUENCE NUMBERS 0272007, 0272014 & 0272011. INFO NOTED CREATED NEW SMC FOR DUCT FOUND BAD.
Part: AIR DUCT — BROKEN (CABIN) · airframe 74,027 hrs · 13,083 cycles
HOT AIR FROM VENTS NEAR SEAT 10A & FLOOR IS HOT. REPLACED BROKEN AIR DUCT.
Part: AIR DUCT — BROKEN (ZONE C) · airframe 74,027 hrs · 13,083 cycles
DEFERRAL DF708 IS OPEN FOR THE ZONE C TRIM AIR VLV BEING DEACTIVATED CLOSED IAW MEL2161J. CREW REPORT THE AREA AROUND ROW 10 IS STILL EXPERIENCING VERY HOT AIR COMING FROM THE FLOOR VENTS. RUNNING TEMP CONTROL IN MAN WITH THE TRIM AIR OFF RESULTED IN AN UNCOMFORTABLY COOL TEMPERATURE IN THE COCKPIT. REPLACED BROKEN AIR DUCT, REACTIVATED TRIM AIR VLV FOR ZONE C. RAN & LEAK CHECKED OK.
Part: DUCT — BROKEN (ZONE C) · airframe 74,027 hrs · 13,083 cycles
ZONE C TRIM AIR INOPERATIVE WITH ASSOCIATED ZONE TRIM AIR MODULATION VLV DEACTIVATED IN THE CLOSED POSITION. COMPLY WITH MEL 2161J DEACTIVATED TRIM AIR VLV IN CLOSED POSITION. REACTIVATED TRIM AIR VLV FOR ZONE C, RAN & LEAK CHECKED FOR REPLACEMENT OF BROKEN DUCT.
Part: RELAY — FAILED (ELECTRICAL SYS) · airframe 73,304 hrs · 12,982 cycles
ELECTRICAL STANDBY SYSTEM ADVISORY & STATUS MESSAGE EXISTING FAULT MX MESSAGE 24-13037, IAW FIM 24-32 802. R & R K24013 IAW AMM 24-32-10 DC TIE RELAY. MESSAGES DISAPPEARED & FINAL CHECKED GOOD.
Part: SLAT SYSTEM — MALFUNCTIONED · airframe 73,271 hrs · 12,976 cycles
SLATS FAIL PRIMARY. ACCOMPLISHED FIM 27-82 TASK 827, TEST OF HIGH LIFT SYSTEM, LRU REPLACEMENT TEST, SLATS PRIMARY CONTROL VALVE TEST FSEU 2 PASSED. SYSTEM OK FOR SERVICE.
Part: WARNING HORN — INOPERATIVE (NLG APU) · airframe 73,066 hrs · 12,949 cycles
NOSE LANDING GEAR APU FIRE HORN INOPERATIVE. NLG APU FIRE HORN REPLACED & TESTED NORMAL PER AMM.
Part: CIRCUIT CARD — FAULTY (FIRE DETECTION) · airframe 72,950 hrs · 12,933 cycles
LT ENGINE FIRE DETECTION SYSTEM LOOP 1 FAILURE. REPLACED LT ENGINE FIRE DETECTION CARD IAW AMM. NO ACTIVE FAULTS PAST TEST.
Part: TRANSCEIVER — INOPERATIVE (RIGHT) · airframe 71,710 hrs · 12,762 cycles
RIGHT HF RADIO INOPERATIVE. INTERNAL FAULT IN TRANSCEIVER. REPLACED RIGHT HF TRANSCEIVER PER MM
Part: SWITCH — FAILED (CARGO HEAT) · airframe 71,704 hrs · 12,761 cycles
AFT CARGO HEAT HEAT SHUTOFF VALVE STATUS MESSAGES. REPLACED AFT CARGO HEAT SHUTOFF VALVE V21441, NO HELP. DURING MAT TEST OF VALVES VISUALLY CHECKED AND VALVES OPERATING NORMALLY. REPLACED SWITCH REF 21-44-10. CHECKED GOOD REF FIM 21--44 TASKS 801-801.
Part: CONNECTOR — FAILED · airframe 71,434 hrs · 12,718 cycles
SCREWS FOR CONNECTORS BROKE DURING REMOVAL. REPLACED CONNECTOR. OPS CHECKED GOOD IAW AMM 24-09-00.
Part: COMPUTER — MALFUNCTIONED (NR 1) · airframe 70,963 hrs · 12,651 cycles
RIGHT CURSOR CONTROL DEVICE INOPERATIVE. REPLACED CURSOR.
2012
Part: BLOCK — CORRODED (CABIN) · airframe 70,179 hrs · 12,535 cycles
EMERGENCY OVERHEAD LIGHTS, RIGHT SIDE ROW 38 TO 46 INOP. FOUND GROUND BLOCK 20691 CORRODED. ATTACHED WIRES TO TEMPORARY GROUND, LIGHTS ALL CHECK GOOD. NEEDS NEW GROUND BLOCK INSTALLED & WIRES INSTALLED. REINSTALLED NEW GROUND BLOCK, STILL NEEDS TO BE REWIRED. REPLACED PINS REF SWPM 20-90-15 AND SECURED WIRES AT TERMINAL BLOCK GB20691DC REF WDM 33-51-16. ALL EMERGENCY LIGHTS OP CHECKED GOOD PER AMM.
Part: CONTROL PANEL — FAULTY (COCKPIT) · airframe 69,958 hrs · 12,504 cycles
MODE CONTROL PANEL LANE STS MESSAGE. REPLACED MCP PER MM, ACFT RETURNED TO FULL AUTOLAND STATUS.
Part: UNKNOWN — MALFUNCTIONED (FUEL SYSTEM) · airframe 69,896 hrs · 12,495 cycles
FUEL PUMP CENTER R RIGHT CENTER (OVERRIDE) FUEL PUMP SWITCHED ON AND PUMP OUTPUT PRESSURE LOW. STATUS CREW COMMENTS: FUEL PUMP CENTER R STATUS MSG. DEFERRED RT CTR FUEL PUMP PER MEL. RESET CB TO PUMP AND ACP TEST REF MM. PUMP OPERATED NORMAL AND ALL MSG'S CLEARED.
Part: CDU — FAULTY (COCKPIT) · airframe 69,558 hrs · 12,446 cycles
STATUS MESSAGES CDU-L AND FMC DISPLAYED. SWAPPED TO CENTER POSITION VERIFIED CENTER CDU INTERMITTENTLY BLANKS. MR34611 DASH 241 IN CENTER POS. DASH 117 LEFT. LEFT CDU OPERATION NORMAL. INSTALLED NEW FMC-CDU CAPT'S LEFT HAND SIDE AND REINSTALLED PREVIOUSLY INSTALLED ON LF SIDE TO ORIGINAL POSITION CENTER POSITION, REF AMM 34-61-02-401
Part: SEAL — LEAKING (R2 DOOR) · airframe 69,173 hrs · 12,389 cycles
F/A REPORTS HISSING SOUND AT DOOR 2R. IN REF TO LOG 2 SEAL DAMAGE IS APPROX 5 INCHES IN LENGTH ON AFT LOWER SIDE OF DOOR. DAMAGE IS A SPLIT AND HAS HAD A PREVIOUS REPAIR. NEW SEAL KIT ON HAND. REPLACED PRESSURE SEAL.
Part: BATTERY — FAULTY (MASTER) · airframe 68,723 hrs · 12,327 cycles
CREW REPORTED A MAIN BATTERY AND CHARGER MESSAGE. REPLACED MAIN BATTERY AND MAIN BATTERY CHARGER PER MM, OPS CHECKED NORMAL, MESSAGES CLEARED.
Part: COMPUTER — FAULTED (POSIT 1) · airframe 68,356 hrs · 12,276 cycles
CREW REPORTS ACFT REQUIRED SIGNIFICANT AILERON TRIM INPUT, FOUND LEFT FLAPERON DRIFTING UP. REACHED POINT TO AFFECT ACFT STABILITY AND SNAPPED BACK DOWN. ON GROUND HAD LEFT PFC LANE FAULT AND ACE L2 FAILED GROUND TEST. REPLACED LEFT PFC AS PER AMM, ALL TEST PASSED. REPLACED L2 ACE AS PER AMM, ALL TEST SUCCESSFUL. ALSO CHECKED WIRING ON NR 10 SPOILER, FOUND OK. ACCOMPLISHED TEST AS PER FIM 27-61-809-810, ALL OK. ACFT OK FOR SERVICE.
Part: CONVERTER — FAULTY (BACKUP GENERATOR) · airframe 68,105 hrs · 12,241 cycles
BACK UP GENERATOR RIGHT STATUS MESSAGE. REPLACED BACKUP GENERATAOR CONVERTER.
Part: CONTROLLER — FAULTY (POSIT 1) · airframe 67,569 hrs · 12,167 cycles
OPBC LEFT STATUS MESSAGE PRESENT. REPLACED CONTROLLER (OVER-HEAD POWER BUSS CONTROLLER), MR23931-21 "ON"UNIT, -56"OFF" UNIT, AS PER MM.
Part: IDG — FAILED (NR 2) · airframe 67,539 hrs · 12,162 cycles
RIGHT GEN LIGHT NOT DISPLAYED. REPAIRED E2 IDG, REPLACED IAW PTT 5392016. REPLACED, OPS AND LEAKED CHECKED E2 IDG.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 67,071 hrs · 12,097 cycles
REF FCD#3321-01019 CONNECTOR D5188J IS INCORRECT PART NUMBER AT STA 1585 S-12R ABOVE SEAT ROW 34R. REPLACED CONNECTOR D5188J WITH CORRECT PART NUMBER BACC65AK231P PER FCD3331-01019.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 67,071 hrs · 12,097 cycles
REF FCD3321-01019 CONNECTOR DM33036C IS IN CORRECT PART NUMBER AT STA 1990 LBL 90 ABOVE LAV. REPLACED CONNECTOR DM33036 WITH CORRECT PART NUMBER BACC65AJ111S PER FCD 3321-01019.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 67,071 hrs · 12,097 cycles
REF FCD#3321-01018 CEILING LIGHT ASSY CONNECTOR AT STA 530 RBL 90 ABOVE SEAT ROW 6R HAS INCORRECT PART NUMBER. CORRECTION STA 570 RBL 90 REPLACED CONNECTOR AT LIGHT ASSY L33145 WITH CORRECT PART NUMBER BACC65AK211P PER FCD 3321-01018.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 67,071 hrs · 12,097 cycles
REF FCD#3321-01019 CONNECTOR DM33021B IS INCORRECT PART NUMBER AT STA 690 RBL 90 ABOVE STOWBIN RAIL OUTBOARD. REPLACED CONNECTOR DM33021B WITH CORRECT PART NUMBER CONNECTOR BACC65AJ112S PER FCD 3321- 01019.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 67,071 hrs · 12,097 cycles
REF FCD#3321-01019 CONNECTOR DM33036C IS INCORRECT PART NUMBER STA 1990 RBL 90 ABOVE LAV. REPLACED CONNECTOR DM33036C WITH CORRECT PART NUMBER BACC65AJ111S PER FCD 3321 -01019.
Part: CONNECTOR — IMPROPER PART (CABIN) · airframe 67,071 hrs · 12,097 cycles
REF FCD#3321-01019 CONNECTOR D5188P IS INCORRECT PART NUMBER AT STA1585 S-12R ABOVE SEAT ROW 34R. REPLACED CONNECTOR D5188P WITH CORRECT PART NUMBER CONNECTOR BACC65AJ131S PER FCD 3321-01 019.
Part: REVEAL — CRACKED (CABIN) · airframe 67,004 hrs · 12,087 cycles
PLASTIC WINDOW PANE CRACKED ROW 43 RIGHT SIDE. ALSO WINDOW 38 RIGHT AND 1K. REPLACED ALL 3 WINDOW REVEAL ASSEMBLIES.
Part: SENSOR — FAULTY (AC BAY) · airframe 66,607 hrs · 12,030 cycles
RIGHT PACK STATUS MESSAGE. REPLACED SENSOR 21517 OPERATION AND INDICATION NORMAL. ALSO REPLACED RIGHT PACK TEMP CONTROLLER PRECAUTIONARY. RELOADED SOFTWARE AND ACCOMPLISHED GROUND TEST.
Part: VALVE — FAULTY (AC BAY) · airframe 66,528 hrs · 12,019 cycles
CABIN CTRL TEMP ISSUE, FLIGHT DIVERTED. REPLACED LT FAMV AS PER AMM. ALSO REPLACED ASCPC AS PER AMM, ALL OPS AND INDICATIONS NOW NORMAL FAMV IS A BORROWED PART FROM AA, PART # 3290744-10, SER #1098. ASCPC IS A BORROWED PART 130344FROM BA, PART# 1151100-7, SER # 081C0971, POS L-H. REFERENCE ERRATIC TEMP CONTROL PROBLEMS IN CABIN AND FLIGHT DECK. REPLACED LT FAMV AS PER AMM. ALSO REPLACED ASCPC AS PER AMM, ALL OPS AND INDICATIONS NOW NORMAL.
Part: FAN — FAILED (CARGO BAY) · airframe 66,515 hrs · 12,016 cycles
DET FAN 2 CARGO AFT AFT CARGO COMPARTMENT SMOKE DETECTOR FAN NR 2 FAILURE. STATUS; DEFERRED IAW MEL 2616B. RPLC'D NR 2 DETECTOR FAN AFT CARGO STS MSG CLEARED AND FAULT NO LONGER ACTIVE.
Part: SOLENOID — FAULTY (LT ENGINE) · airframe 66,515 hrs · 12,016 cycles
L ENG CONTROL EICAS AND STS MSG AFTER ENG START. REPLACED NR 1 ENG 2.9 BLEED VALVE SOLENOID PER MM. TESTED OKAY PER MM. ACP 5 MIN IDLE RUN NO FAULTS AT THIS TIME.
Part: SEAT — FAILED (COCKPIT) · airframe 66,386 hrs · 11,997 cycles
WHILE ELECTRICALLY MOVING FIRST OFFICER'S SEAT, THERE WAS A SPARK. SEAT MANUAL CONTROLS OKAY. CIRCUIT BREAKER PULLED AND COLLAR. SEAT CHECKED AND NO DAMAGED FOUND. REPLACED SEAT PER AMM. OPS CHECKED NORMAL.
2011
Part: SLIDING WINDOW — NOISY (COCKPIT) · airframe 66,133 hrs · 11,958 cycles
HIGH PITCH TONE AUDIBLE TO BOTH PILOTS IN CRZ. MAYBE CAPTS WINDOW. CREW VERBAL SLIGHT NOISE COMING FROM BOTTOM AFT CORNER OF CAPTS SLIDING WINDOW. FOUND EXCESSIVE AMOUNT OF SEALANT ON INSIDE OF AFT BOTTOM CORNER. REMOVED EXCESSIVE SEALANT. NOISE RECURRED. ADJUSTED WINDDOW PER MM. PRESSURIZED AC UP TO 4 DP, NO LEAKS NOTED. DUE TO CHRONIC REPORTS OF HIGH PITCHED SQUEAL FROM CAPTAIN'S SLIDING WINDOW WITH SEAL RPLCMNT & WINDOW ADJUSTMENT ACCOMPLISHED PRIOR, REPLACE 2L SLIDING WINDOW (PCN 120-7773). RMV'D AND REPLACED WINDOW PER MM. ALL OPS CKS GOOD. ALSO PRESS TESTED TO 4.5, NO NOISES NOTED ALL OKAY.
Part: OIL SYSTEM — LEAKING (APU) · airframe 65,994 hrs · 11,938 cycles
CREW COMPLAINED OF STRONG ODOR IN CABIN WITH APU BLEED AND PACKS ON. SUSPECT OIL ODOR COMING FROM APU. ACCOMPLISHED TASK 49-10-808. FOUND LOAD CONTROL VALVE WITH OIL LEAK AND OIL FROM TAILPIPE, NO OIL IN OIL TANK, HAVE STATUS MESSAGE APU AND APU OIL SHOWS 0 .00 ON EICAS. ADDED 6.0 QUARTS OIL ENTERED INTO OIL SVC. RAN APU AFTER 10 MINUTES OIL QUANTITY DOWN 1.5 QUARTS. APU REPLACED.
Part: SEAL — LEAKING (NR 2 WINDOW) · airframe 65,852 hrs · 11,917 cycles
AIR LEAK AT CAPTAIN'S WINDOW. APPEARS TO BE LOW LEFT CORNER. INSTALLED NR 2 WINDOW SEAL PER AMM. WINDOW SEAL INSTALLATION CHECKED OKAY. APPLIED SEALANT.
Part: PBE — DAMAGED (R3 DOOR) · airframe 65,781 hrs · 11,906 cycles
PBE AT DOOR 3R IS SPONGY AND SOFT PER "A" CHECK. REPLACED PBE.
Part: PBE — DAMAGED (R4 DOOR) · airframe 65,781 hrs · 11,906 cycles
PBE AT DOOR 4R IS SPONGY AND SOFT PER "A" CHECK. REPLACED PBE.
Part: SOLENOID — FAULTY (NR 1 ENGINE) · airframe 65,405 hrs · 11,853 cycles
ENG 1 2.9 START BLEED. 2369-1 ENG 777029 EICAS 'ENG CONTROL L' MAINT MSG 75-60471 2.9 START BLEED VALVE (L ENG) NOT IN COMMANDED POS' AFTER ENGINE START. ACP'D INSPECTION OF 2.9 START BLEED VLV MUSCLE LINES, NO DEFECTS FOUND. CLEANED PS3 FILTER. TESTED START BLEED VALVE IAW TASK 71-08 818 ITEM F. VLV OPS NORMAL. RAN ENG FOR 5 MIN NO MSG'S PRESENT. SYSTEM NORMAL.
Part: UNKNOWN — MALFUNCTIONED (FUEL SYSTEM) · airframe 65,201 hrs · 11,822 cycles
STATUS MSG R CTR FUEL PUMP INOP. MESSAGE 28-12021 ELCU CTR R OVRD FUEL PUMP IN P200 IS OPEN. -INF- :BOEING AHM REPORTS MMSG 28-12011 REF FIM 28-22 TASK 815. ACCOMPLISHED FIM 28-22 TASK 815. MESSAGE CLEARED OK.
Part: CONTROLLER — FAULTY (COCKPIT) · airframe 65,010 hrs · 11,793 cycles
OPBC L OVERHEAD PANEL BUS CONTROLLER (OPBC) FAULT STATUS MSG. WILL NEED PCN 583-9017 PART AVAIL IN HAM. WILL BE ON FLT 2075 ETD 1730 ETA 1845. REPLACED LEFT OPBC IAW AMM. ALL RELEVANT CHECKS OKAY. CLEARED MSG.
Part: FEEDER CABLE — DAMAGED (NR 1 IDG) · airframe 65,002 hrs · 11,792 cycles
THE T2 LUG ON THE NR 1 IDG IS BURNED AND NEEDS TO BE REPLACED. REMOVED IDG FEEDER CABLES PER MM. OLD HARNESS ON TABLE BY ENGINE ALONG WITH ALL ATTACHING HARDWARE. REPLACED FEEDER CABLE HARNESS W0650 ON NR 1 ENGINE FROM IDG TO TERMINAL BLOCK ASSY.
Part: HOUSING — DAMAGED (NR 1 ENGINE) · airframe 65,002 hrs · 11,792 cycles
NR 1 ENG OIL FILTER HOUSING HAS THREE PULLED STUDS HOUSING AND STUDS ON AOG. (X4919, C4407, C4606. FOUND HOUSING IN ATL) NR 1 ENGINE MAIN OIL FILTER 3 OF 4 STUDS THAT HOLD OIL FILTER COVER PULLING OUT. REMOVED MAIN OIL FILTER HOUSING PER MM. NEED TO REINSTALL NEW HOUSING PER MM. INSTALLED MAIN OIL FILTER HOUSING & SERVO FUEL HEATER, AWAITING AOG'S D0779 & B2462 FOR ITEM 90 IPC 79-21-00-010 & ITEM 1 IPC 79-21-00-011. INSTALLED ITEM 90 ON IPC 79-21-00-010 AND ITEM 1 ON IPC 79-21-00-011.
Part: TERMINAL BLOCK — UNSECURE (IDG) · airframe 65,002 hrs · 11,792 cycles
IDG TERMINAL BLOCK UNABLE TO TIGHTEN FEEDER CABLES STUD LOOSE. REPLACED TERMINAL BLOCK. BLOCK IN PLACE, COVER IS OFF WAITING FOR NEW NUTS. COVER AND SCREWS LOOSELY SECURED TO SIDE OF IDG. SECURED FEEDER TERMINALS AND COVER AFTER REPLACEMENT OF FEEDER HARNESS W0650.
Part: UNKNOWN — OVERFLOW (GALLEY) · airframe 65,002 hrs · 11,792 cycles
CM, M62, AFT GALLEY, CM OVERFLOWS. REPLACED CM.
Part: LINE — DAMAGED (HYD SYSTEM) · airframe 64,781 hrs · 11,759 cycles
PRESSURE LINE FOR ENG HYD PUMP INSULATION MELTED AT PYLON CONNECTION FROM HYD LEAK. REPLACED NR 2 ENG PRESSURE LINE PER MM. FOUND NO LEAKS ON RETURN LINE. LEAK CHECK OK. REPLACED INSULATION BLANKET AND 2 CLAMPS.
Part: BLEED VALVE — FAILED (BLEED SYS) · airframe 64,781 hrs · 11,759 cycles
BLEED FAMV R RIGHT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN OR CLOSED, OR RIGHT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. STATUS MSG-3610532 LATCHD ER MODE. REPLACED NR 2 FAMV PER MM.
Part: SEALANT — OUT OF TOLERANCE (COCKPIT WINDOW) · airframe 63,760 hrs · 11,612 cycles
F/O SLIDING WINDOW NOISE BEGAN 30 MIN AFTER T/O AND LEVEL OFF FL340. PRESSURIZED AIRCRAFT AND FOUND AREA UPPER AFT CORNER OF WINDOW R1 LEAKING AIR. RETORQUED WINDOW R1 IAW MM AND REPLACED 3 INCHES OF SEALANT IN SAID AREA. APPLIED TAPE OVER SEALANT FOR SMOOTHING.
Part: FAN — FAULTY (CABIN) · airframe 63,479 hrs · 11,572 cycles
CREW REPORTS CABIN CREW HAD SMOKE IN CABIN WITH ACRID SMELL AND SHORTLY AFTER A "RECIRC FAN" STATUS MSG APPEARED. CREW TURNED OFF RECIRC FAN SW AND HAD CABIN CREW TURN OFF ALL CABIN LIGHTS AND GALLEY PWR. AHM SHOWS LWR LEFT RECIRC FAN FAULT (MAINT MSG#21-24600). SMOKE AND SMELL CLEARED IN THE CABIN. REPLACED LT LOWER RECIRC FAN, FOUND CB A18 OPEN WHEN PREPPING FOR REPLACEMENT, FOUND SOOT AND BURN SMELL IN FAN. RAN PACKS AFTER, NO BURNING SMELL OR SMOKE NOTED.
Part: DISPLAY — INOPERATIVE (COCKPIT) · airframe 62,541 hrs · 11,441 cycles
F/O INBD IDU IS BLANK. REPLACED F/O'S RIB DISPLAY UNIT AND OPS TESTED OK.
Part: GIRT BAR — DIRTY (R3 DOOR) · airframe 62,430 hrs · 11,427 cycles
IAW FLIGHT CREW, DOOR 3R DIFFICULT TO DISARM. CLEANED GIRT BAR. DOOR OPS CHECKED GOOD DOOR 3R.
Part: STARTER — FAULTY (LT ENGINE) · airframe 62,347 hrs · 11,416 cycles
LEFT ENGINE WOULD NOT START AUTO OR MANUAL. REPLACED LEFT ENGINE STARTER IAW AMM.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 62,262 hrs · 11,404 cycles
MID AFT GALLEY CENTER EMERGENCY LIGHT INOP BETWEEN GALLEY CARTS. REPLACED LIGHT ASSY LIGHT OP CHECKED OKAY.
2010
Part: SATCOM — FAULTY · airframe 61,947 hrs · 11,360 cycles
SDU INTERNAL FAULT GIVING MSG 23-60541. REPLACED SDU IAW MM, NO FAULTS AFTER UNIT WAS REPLACED.
Part: RECEPTACLE — DIRTY (GIRT BAR) · airframe 61,926 hrs · 11,356 cycles
DOOR 4L SLIDE DOES NOT DISARM COMPLETELY. CLEANED AND LUBED GIRT BAR RECEPTACAL, OPS NORMAL
Part: FSEU — FAULTY (TE FLAPS) · airframe 61,163 hrs · 11,249 cycles
FLAPS PRIMARY FAIL EICAS WHEN FLAP HANDLE EXTENDED FROM UP TO 5. REPLACED FSEU NR 2 PER AMM. FLAP OPS CHECKS OKAY.
Part: FAIRING — DAMAGED (RT WING TO BODY) · airframe 61,021 hrs · 11,228 cycles
RT WING TO BODY LOWER FAIRING 196FR IS DAMAGED AND 60% OF PANEL MISSING. INSTALLED NEW PNL AT POS 196FR. PANEL SECURED IN PLACE, ALL CHECKS OKAY.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHT) · airframe 60,923 hrs · 11,215 cycles
EMERGENCY CEILING LIGHT IS OUT. SECOND LIGHT FROM AFT CABIN IN COACH RT SIDE. REPLACED M33208, M33209 AND RELAMPED, CHECKED OKAY.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 60,923 hrs · 11,215 cycles
AFT GALLEY EMERGENCY LIGHTS AT FLOOR LEVEL ARE OUT. REPLACED ONE LIGHT ASSY AND M33409 AND M33408. RESPLICED SM4 DUE TO HIGH RESISTANCE. LIGHTS CHKD OKAY.
Part: LIGHT — INOPERATIVE (SEAT 1E) · airframe 60,923 hrs · 11,215 cycles
SEAT 1E AFT EMERGENCY LIGHT IS OUT. REPLACED LIGHT ASSY. OPS C HECKS GOOD.
Part: CHARGER — FAILED (NR 1) · airframe 60,262 hrs · 11,120 cycles
MAIN BATTERY MAIN BATTERY FAILURE. STATUS MSG01- ACTIVE CRUISE HARD; MAIN BATTERY IS WEAK. MAIN BATTERY CHARGER IAW MM. OPS ARE NORMAL.
Part: BATTERY — FAULTY (MASTER) · airframe 60,262 hrs · 11,120 cycles
MAIN BATTERY OVERHEAT, MAIN BATTERY OVER TEMPERATURE. STATUS MSG01- ACTIVE CRUISE HARD; MAIN BATTERY IS OVERHEATED. DB- ELMS P310 ELECTRONICS UNIT MSG02- ACTIVE CRUISE HARD; MAIN BATTERY IS OVERHEATED. REPLACED MAIN BATTERY, ALL FAULTS CLEARED. BATTERY CHECKS GOOD.
Part: CONVERTER — FAILED (GENERATOR) · airframe 59,824 hrs · 11,054 cycles
ELECTRICAL BACKUP SYS STATUS MSG. BOTH BACK UP GEN OFF IN FLT. FLT CREW CYCLED BOTH PUSH BUTTON SWS AND BACK UP GENERATORS WORKED FINE AGAIN FOR THE REMAINDER OF THE FLT. CHECKED MAT-SHOWS MTC MSG FOR L AND R BUG 24-45490-NOT ACTIVE. CHECKED BUG OIL-INDICATES NORMAL. CONTACTED SAMC. NO HISTORY. BUG CONVERTER TEST VIA MAT TEST PASSED. CLEARED AFTER BACKUP GEN CKLIST DONE. REPLACED BUG CONVERTER IAW MM. GROUND CHECKS NORMAL. ACFT RETURNED TO SVC.
Part: CIRCUIT CARD — FAULTY (ELECTRICAL SYS) · airframe 59,657 hrs · 11,028 cycles
MAIN BATTERY MAIN BATTERY FAILURE. STATUS MSG-2413054 ACTIVE ER INTER. REPLACED ELMS FILTER CARD M24406A16. MSG'S ERASED, SOFTWARE OKAY.
Part: CONVERTER — FAULTY (ELECTRICAL SYS) · airframe 59,657 hrs · 11,028 cycles
VSCF, BEPS STATUS MSG. CONVERTER FOUND FAULTY. REPLACED BACK UP CONVERTER. ENGINE RUN PERFORMED. OPS CHECK TEST PASSED.
Part: BATTERY — FAULTY (MASTER) · airframe 59,655 hrs · 11,027 cycles
MAIN BATTERY DISCH MAIN BATTERY DISCHARGING OR HOT BATTERY BUS UNPOWERED. ADVISORY CREW COMMENTS: MAIN BATTERY DISCH. REPLACED SHIPS MAIN BATTERY AND MAIN BATTERY CHARGER. ALL CHECK OK.
Part: CHARGER — FAULTY (MASTER BATTERY) · airframe 59,655 hrs · 11,027 cycles
NEED TO REPLACE SHIPS MAIN BATTERY CHARGER PRECAUTIONARY, WITH OPBLM CONCURRENCE, DUE TO OVERHEAT PROBLEM. EICAS MESSAGE MAIN BATTERY DISCHARGE. REPLACED MAIN BATTERY CHARGER. OPS ARE GOOD.
Part: CHECK VALVE — LEAKING (RT FUEL TANK) · airframe 59,653 hrs · 11,026 cycles
3400 POUND FUEL IMBALANCE DURING CRUISE WHILE CTR TANK FEEDING. LT SIDE L. ACCOMPLISHED MT 28-008R2. FOUND RT TANK FWD PUMP DISCHARGE CHECK VALVE LEAKING. REPLACED VALVE.
Part: ACTUATOR — LEAKING (THRUST REVERSER) · airframe 59,593 hrs · 11,017 cycles
NR 1 ENGINE HAS BROKEN REV LATCH AND NR 1 VSV ACTUATOR LEAKING. REPLACED SVA PER MM AND ACCOMPLISHED ENGINE TESTS 2A, 3, 6 AND 15. REPLACED FWD LATCH.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 59,383 hrs · 10,983 cycles
EMERGENCY LIGHTS INOP AT SEATS 1F, 2E, 3F. REPLACED LAMP ASSYS, OPS CK OK.
Part: ACM — FAILED (LEFT) · airframe 59,381 hrs · 10,982 cycles
CREW REPORT ELECT ODOR IN CABIN FOR APPROX (5) MINUTES. F/A REPORT GRINDING VIBRATION FELT, REPORTED RT SIDE OF ACFT. GRINDING STOPPED, AND ODOR DISSIPATED. FOLLOWED BY PACK MODE L ADV MSG, AND PACK ACM L STATUS MSG. CMC MSG 21-24821 (ACM L DOES NOT COOL) REPLACED LEFT PACK ACM, OPS CHECKED NORMAL.
Part: OVEN — FAULTY (GALLEY) · airframe 58,969 hrs · 10,923 cycles
30 MINUTES AFTER T/O ELECT ODOR IN 1ST CLS GALLEY AND ROW 15. ODOR LASTED ABOUT 3 HOURS AND THEN DISSIPATED. REPLACED 1ST CLASS GALLEY OVEN R11. OPS OK.
Part: IDG — DISCONNECTED (LT ENGINE) · airframe 58,669 hrs · 10,871 cycles
LEFT IDG DISCONNECTED. REPLACED LEFT ENG IDG. ACCOMPLISHED LEFT ENG IDLE RUN AND ALL INDICATIONS OK NOW. LEFT IDG SYS OK FOR SERVICE.
Part: IDG — FAULTY (NR 1 ENGINE) · airframe 58,609 hrs · 10,861 cycles
LOST LEFT GEN. LEFT GEN DRIVE LIGHT CAME ON. REPLACED NR 1 IDG AND REPLACED IDG OIL SEAL.
Part: PIN — UNSAFETIED (GIRT BAR) · airframe 58,600 hrs · 10,856 cycles
PASSENGER DOOR 1L REMOVED FOR TRAINING. FOUND SAFETY WIRE MISSING ON GIRT RELEASE SAFETY PIN. REPLACED SLIDE.
Part: SKIN — DAMAGED (RT WING AILERON) · airframe 58,600 hrs · 10,856 cycles
RT WING TIP HAS DAMAGE. NEED TO REMOVE AILERON PRIOR TO UPPER AND LWR SKIN REMOVAL. AILERON REMOVED. SKIN PANELS READY FOR REMOVAL. RT SKIN PANELS ON AOG. LOWER SKIN PANEL INSTALLED, UPPER SKIN PANEL APPROX 80 PERCENT COMPLETE. DAMAGED PARTS REPLACED PER DRAWINGS LISTED AND APPLICABLE SRMS REGARDING PROCEDURES AND INSPECTIONS COMPLETED AS COVERED IN UAEVA-73537. DWG NUMBERS ARE 112W4600, 112W3600, 112W5700, 116W4520, 116W4001, 112W4400, 115W4114, 115W4501 USED FOR INSTALLATION AND REQUIRED INSPECTIONS OF THESE PSE'S COMPLETED. VERIFIED REQUIRED INSPECTIONS COMPLETED IN REFERENCE TO EACH PSE INSTALLATION PER ABOVE LISTED DRAWINGS AND BOEING SR 1-1520642598, REF EVA-73537.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 58,579 hrs · 10,852 cycles
SIDEWALL LIGHT INOP AT ROW 9A. RELAMPED. CHECKS OK.
Part: STARTER — FAULTY (RIGHT) · airframe 58,430 hrs · 10,824 cycles
ENG START VALVE R RT STARTER AIR VALVE POSITION DISAGREES WITH COMMANDED POSITION OR STARTER AIR VALVE POSITION INDICATION IS LOST. REPLACED STARTER AND START VALVE IAW MM. OP CKS NORMAL.
2009
Part: CONTROLLER — FAULTY (PAX ADDRESS SYS) · airframe 57,994 hrs · 10,760 cycles
PASSENGER ADDRESS STATUS MESSAGE ON EICAS. REPLACED PASSENGER ADDRESS CONTROLLER AND CABIN SYS MANAGEMENT UNIT, RESET ACFT. OP CHKS NORMAL.
Part: VALVE — FAULTED (ANTI ICE SYS) · airframe 57,986 hrs · 10,759 cycles
RT WING ANTI-ICE (WAI) VALVE FAILURE. FOUND WAI VALVE AT FAULT. REPLACED VALVE AND OPS CHECKS OK.
Part: ENGINE — MAKING METAL (NR 1) · airframe 57,820 hrs · 10,732 cycles
EXCESSIVE METAL PARTICLES FOUND ON NR 1 ENG MASTER CHIP DETECTOR AND MAIN GEARBOX CHIP DETECTOR. NR 1 ENG NO ROTATION. DUE TO REPORT OF ENGINE NOT CRANKING AT START ALONG WITH PMA-N2 MSG AS REPORTED BY SFOEP, MX FOUND EXCESSIVE METAL PARTICLES ON NR1 ENG MASTER CHIP DETECTOR & MAIN GEARBOX CHIP DETECTORS. POSSIBLE GEAR BOX "MB7" BRG FAILURE. REQUIRES LT ENG CHANGE. ENG REPLACED BY ESN 777029.
Part: WIRE — GROUNDED (FLIGHT CONTROL) · airframe 57,820 hrs · 10,732 cycles
FLIGHT CONTROL SYS ANY CONDITION OF THE FLIGHT CONTROL SYSTEM OR IT'S SYSTEM INTERFACES WHICH WOULD PREVENT DISPATCH. FLIGHT CONTROLS SYSTEM BELOW MINIMUM DISPATCH REQUIREMENTS. FOUND W7754-3001B-20 GROUNDED TO SHIELDING REPAIRED SAME, OPS CHECKED GOOD.
Part: WIRE — MALFUNCTIONED · airframe 57,809 hrs · 10,731 cycles
FLIGHT CONTROL SYS STATUS MSG WITH ACTIVE MNT MSGS 27-10003 AND 27-10014. FURTHER T-S SHOWED THAT STABILIZER OPERATES WITH RT SYSTEM ONLY BY MANUAL OVERRIDE. NO MOVEMENT USING EITHER CONTROL COLUMN SWITCHES. NORMAL OPERATION WITH CENTER SYSTEM. PERFORMED FIM 27-41 TASK 802, CONFIRMED RT STCM SHUTOFF VALVE (M27213 V6) AT FAULT. NEEDS TO REPLACE RT STCM. FOUND SHORT IN WIRE FROM PRESSURE BULKHEAD TO STAB MODULE CONNECTOR. REPLACED CONNECTOR AT RT STCM -NO HELP. CONNECTOR DM27122AC STILL SHOWS GROUND AT PIN A2. NEED TO ACCESS CONNECTOR D7894P AT STA 2162. FOUND W7754-3001B-20 BETWEEN CONNECTORS D7894P AND DM27213B GROUNDED. REPAIRED SAME AND OPS CHECKED GOOD.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 57,488 hrs · 10,671 cycles
EXTERIOR EMERGENCY LIGHT AT DOOR 3 RIGHT INOP. RELAMPED EMERGENCY LIGHT AT DOOR 3R. OP CHECKS GOOD.
Part: ISOLATION VALVE — MALFUNCTIONED (BLEED AIR SYS) · airframe 57,381 hrs · 10,652 cycles
BLEED AIR ISOLATION VALVE STATUS MESSAGE DISPLAYED, PER CREW. REPLACED RIGHT BLEED AIR ISOLATION VALVE. TESTED AND OP CHECKS GOOD. DURING ACCOMPLISHMENT OF PROCEDURES PER MEL 3612B (RECYCLED) VALVE AND DEVICE RETURNED TO NORMAL OPERATION.
Part: PROCESSOR — FAULTY (FUEL SYSTEM) · airframe 57,055 hrs · 10,599 cycles
BOTH RIGHT MAIN REFUELING VALVES WILL NOT OPEN. REPLACED FUEL QTY PROCESSOR, CHECKS OKAY.
Part: DUCT — CRACKED (CARGO BAY) · airframe 56,948 hrs · 10,584 cycles
DUCTS FOUND CRACKED. CEILING SUPPORT REMOVED REPLACING 8FT DUCT IN AFT PIT SIDE WALL, WILL NEED TO ACP ADP DUCT SYST SECURITY & LEAK CHECKS AFTER DUCT INSTALL. ALSO FOUND DUCT FLANGE TO ADP SUPPLY CRACKED (T-FLANGE DOWN FROM DUCT CENTER). REPLACED DUCTS. PRESSURIZED DUCTS. NO LEAKS NOTED.
Part: COUPLER — FAULTY (HF COMM) · airframe 56,496 hrs · 10,515 cycles
LEFT HF CAN BE TUNED AND RECEIVED BUT ONLY TUNING SQUEAL HEARD WHEN ATTEMPTED. MAINT MESSAGE 23-51010 LEFT COUPLER HAS INTERNAL FAULT. REPLACED COUPLER. GROUND CHECKED OK.
Part: OVEN — DIRTY (GALLEY) · airframe 55,746 hrs · 10,407 cycles
WARMING OVEN - SMOKING, NEEDS CLEANING DR-1 LT GAL 410. CLEANED WARMING OVEN GAL 410 DR-1. CHECK OK NOW, NO SMOKING FOUND.
Part: PACKING — DAMAGED (NR 2 ENGINE) · airframe 55,144 hrs · 10,311 cycles
EVIDENCE OF FUEL LEAK AND FIRE DAMAGE AT NR 2 ENGINE MAIN FUEL HOSE AT DISCONNECT PANEL. SPRAY SHIELD HAS BURN THROUGH BELOW CONNECTION. REPLACED LINE PACKING AND INSULATION BLANKET, LEAKED CHECKED WITH ENGINE MOTOR.
Part: WINDOW — LEAKING (#2 SLIDING) · airframe 55,035 hrs · 10,291 cycles
AIR LEAK IN WINDSCREEN. RTFL. CAPTAIN'S NR 2 SLIDING WINDOW NEEDS REPLACEMENT. WINDOW REPLACED.
Part: LIGHT — INOPERATIVE (EXTERIOR) · airframe 54,407 hrs · 10,189 cycles
DOOR 3 LEFT EXTERNAL EEL LIGHT INOP. RELAMPED, OP CHECKS GOOD.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 54,407 hrs · 10,189 cycles
SEAT 22C EEL LIGHT INOP. RELAMPED, OP CHECKS GOOD.
Part: EXCITER — DEFECTIVE (LT ENGINE) · airframe 54,407 hrs · 10,189 cycles
ENG IGNITOR L1 LEFT ENGINE FAILED TO IGNITE USING IGNITER 1. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; IGNITION SYSTEM NR 1 (L ENG) FAILED TO LIGHT ENGINE. DB- ELECTRONIC ENGINE CONTROL (L ENG, CH B) MSG-7461491 INACTIVE ES MODE. REPLACED EXCITER BOX.
Part: EXCITER — MALFUNCTIONED (LT ENGINE) · airframe 54,407 hrs · 10,189 cycles
ENG IGNITER L1 LEFT ENGINE FAILED TO IGNITE USING IGNITER 1. STATUS MSG01- NOT ACTIVE ENGINE START MODE DEPENDENT; IGNITION SYSTEM NR 1 (L ENG) FAILED TO LIGHT ENGINE. DB- ELECTRONIC ENGINE CONTROL (L ENG, CH B) MSG-7461491 INACTV ES MODE. REPLACED EXCITER BOX.
Part: CONNECTOR — DAMAGED (CABIN) · airframe 54,407 hrs · 10,189 cycles
SEAT 2E AFT EEL LIGHT INOP. CONNECTOR DAMAGED ON SEAT HARNESS.
Part: CONNECTOR — DAMAGED (CABIN) · airframe 54,407 hrs · 10,189 cycles
SEAT 2E AFT EEL LIGHT INOP. CONNECTOR DAMAGED ON SEAT HARNESS.
Part: LIGHT — INOPERATIVE (CABIN) · airframe 54,407 hrs · 10,189 cycles
SEAT 20G EEL LIGHT INOP. RELAMPED AND REPLACED MISSING LIGHT COVER, OP CHECKS GOOD.
Part: CASTING — BROKEN (R4 DOOR) · airframe 54,008 hrs · 10,125 cycles
UNABLE TO OPEN DOOR 4R UPON ARRIVAL. FOUND AFT GIRT BAR MECHANISM MOUNT CASTING BROKEN IN HALF. REPLACED BROKEN CASTING. NO RIGGING REQUIRED. DOOR ARM, DISARM AND OPEN AND CLOSE. OPS GOOD.
Part: GIRT BAR — BROKEN (DOOR 4R) · airframe 54,008 hrs · 10,125 cycles
UNABLE TO OPEN DOOR 4R UPON ARRIVAL. FOUND AFT GIRT BAR MECHANISM MOUNT CASTING BROKEN IN HALF. REPLACED BROKEN CASTING. NO RIGGING REQUIRED. DOOR ARM, DISARM AND OPEN & CLOSE, OPS GOOD.
2008
Part: SLIDE — FAULTY (L4 DOOR) · airframe 53,841 hrs · 10,100 cycles
THE 4L ENTRY DOOR WILL NOT OPEN GIRT BAR JAMS ON FLOOR. REMOVED SLIDE. INSTALLING NEW SLIDE AT DOOR 4L. INSTALLED GIRT BAR. COMPLETED INSTALLATION OF SLIDE AT DOOR 4L. CHECKED DOOR OPENING AND CLOSING AND ARMING AND DISARMING, CHECKS GOOD.
Part: NOSE COWL — DENTED (NR 2 ENGINE) · airframe 53,477 hrs · 10,045 cycles
BIRD STRIKE NR 2 ENGINE INLET COWL AT 1 O'CLOCK POSITION. BAD COWL REMOVED.
Part: PUMP — FAILED (FUEL BOOST) · airframe 53,233 hrs · 10,008 cycles
FUEL PUMP R FWD RIGHT FORWARD (BOOST) FUEL PUMP SWITCH ON AND PUMP OUTPUT PRESSURE LOW. STATUS MSG01- ACTIVE CLIMB MODE DEPENDENT; RELAY (R FWD FUEL BST PMP SWITCH) IN P110 IS NOT IN COMMANDED POSITION. DB- ELMS P110 ELECTRONICS UNIT MSG-2811007 ACTIVE CL MODE. FOUND FAULTY BOOST PUMP. REPLACED RIGHT FWD BOOST PUMP. OP CHECKS GOOD.
Part: SMOKE DETECTOR — FAULTY (E/E BAY) · airframe 52,566 hrs · 9,899 cycles
DET CHAN 2 E-E SMOKE ELECTRICAL EQUIPMENT (E-E) COOLING SMOKE DETECTOR CHANNEL 2 FAILS BITE CHECK. STATUS MSG01- ACTIVE CRUISE HARD; E-E COOLING SMOKE DETECTOR HAS NO OUTPUT OR IS FAILED. DB- CARGO SMOKE DETECTOR CH 2 (LWR FWD) MSG02- ACTIVE CRUISE HARD; E-E COOLING SMOKE DETECTOR HAS NO OUTPUT OR IS FAILED. MSG-2620070 ACTIVE ER HARD.
Part: SMOKE DETECTOR — FAULTY (E&E BAY) · airframe 52,566 hrs · 9,899 cycles
DET CHAN 2 E-E SMOKE ELECTRICAL EQUIPMENT (E-E) COOLING SMOKE DETECTOR CHANNEL 2 FAILS BITE CHECK. STATUS MSG01- ACTIVE CRUISE HARD; E-E COOLING SMOKE DETECTOR HAS NO OUTPUT OR IS FAILED. DB- CARGO SMOKE DETECTOR CH 2 (LWR FWD) MSG02- ACTIVE, CRUISE HARD; E-E COOLING SMOKE DETECTOR HAS NO OUTPUT OR IS FAILED. MSG-2620070 ACTIVE ER HARD, MSG-2620070 ACTIVE ER HARD. *S/D* REPLACED EE COOLING SMOKE DETECTOR.
Part: FAN — SMOKE (COCKPIT) · airframe 52,564 hrs · 9,898 cycles
SMOKE/FUMES IN COCKPIT. FLIGHT DIVERTED. FOUND RECIRC FAN FAILURE CAUSE OF SMELL. REPLACED UPPER FWD RECIRC FAN. REPLACED EE SMOKE DETECTOR (P/N 2118860-4). A/C CLEARED FOR SERVICE.
Part: STARTER — MISRIGGED (NR 1 ENGINE) · airframe 51,181 hrs · 9,662 cycles
NR 1 ENGINE START VALVE APPEARS TO BE ASSEMBLED IMPROPERLY TO ALLOW MANUAL START, VALVE DOES NOT ALIGN WITH TUBE IN COWL. FOUND ALIGNMENT TANG TO BE 30 DEGREES OFF WHEN ASSEMBLED IN SHOP. REPLACED STARTER VALVE REF MM 80-11-02, OPS CHECKS OK.AC OK FOR SERVICE.
Part: ACM — FROZEN (LEFT) · airframe 51,095 hrs · 9,647 cycles
LEFT PACK AIR CYCLE MACHINE FROZEN.
Part: WIRE — BROKEN (GIRT BAR) · airframe 50,618 hrs · 9,568 cycles
WHILE REMOVING SLIDE FOUND BREAK AWAY WIRE ON GIRT BAR LANYARD BROKEN.
2007
Part: LAMP — BROKEN (EMERGENCY LIGHTS) · airframe 49,682 hrs · 9,419 cycles
SEAT 1E AFT EMERGENCY LIGHT ON ARMREST BROKEN OFF. RELAMPED.
Part: LAMP — BROKEN (CABIN) · airframe 49,527 hrs · 9,395 cycles
EEL LIGHTING AT SEAT 1E BROKEN. INSTALLED LAMP
Part: UNKNOWN — VIBRATION (LT ENGINE) · airframe 49,360 hrs · 9,369 cycles
ON STARTING LEFT ENGINE, LOUD RUMBLING NOISE AND HEAVY VIBRATION FELT IN CABIN. RAN NUMEROUS DIAGNOSTIC TESTS ON LT ENGINE. NO ENGINE PROBLEM NOTED. DURING DRY MOTORING, AIR SURGES THROUGH ENG CORE, SIMILAR TO PREVIOUS APU SURGE CONTROL VALVE FAULT, ACCOMPLISHED NR 2 ENG START. ACCOMPLISHED DUAL ENG START FROM OUTSIDE AIR SOURCE, UNABLE TO DUPLICATE PROBLEM. ALL OPS NORMAL.
Part: SLIDE — FAULTY (L3 DOOR) · airframe 49,319 hrs · 9,363 cycles
NR 3 LT MED SLIDE IS FAULTY. REPLACED SLIDE ASSY. OK FOR RETURN FOR SERVICE.
Part: BOTTLE — FAULTY (DOOR SLIDE) · airframe 49,319 hrs · 9,363 cycles
NR 3 MED EMERG SLIDE DOOR ASST BOTTLE NEEDS SERVICING. REPLACED BOTTLE AND SQUIB ASSEMBLY. OK FOR SERVICE
Part: COVER — DAMAGED (SEAT 24D) · airframe 48,448 hrs · 9,216 cycles
COVER AT 24D HAS SHARP EDGE AT PAX FEET. [08-08-07] REPOSITIONED COVER PLATE AT SEAT 24D. NO LONGER HAS SHARP EDGE AT CONTACT POINT. OPERATES SATISFACTORIALLY.
Part: BATTERY PACK — UNRELIABLE (L2 DOOR) · airframe 48,293 hrs · 9,192 cycles
DOOR 2L EPAS BATTERY PACK -DATE LAST SERVICED OR MFG- IS UN-READABLE. [07-27-07] REPLACED DOOR 2L EPAS BATTERY PACK. AIRCRAFT READY FOR SERVICE.
Part: LAMP — INOPERATIVE (EMERGENCY LIGHTS) · airframe 47,830 hrs · 9,114 cycles
EXTERIOR EMERGENCY LIGHT AT DOOR 2R IS OUT. [SUP 06-06-07] RELAMPED.
Part: LIGHT — BROKEN (CABIN) · airframe 47,701 hrs · 9,226 cycles
AFT EMERGENCY LIGHT ON SEAT 2F IS BROKEN. REPLACED LIGHT.
Part: LIGHT — UNSECURE (CABIN) · airframe 47,568 hrs · 9,073 cycles
EEL STRIP ON SEAT 2E LOOSE. SECURED STRIP ON SEAT. NO DEFECTS NOTED.
Part: SIGN — DAMAGED (EMERGENCY LIGHTS) · airframe 46,703 hrs · 8,928 cycles
FOUND DOORS 4R 4L EMERGENCY EXIT SIGNS ARE DAMAGED. DOOR 4R EXIT LIGHT COVER MISSING AT POSITIONS FORE & AFT OF DOOR AT KNEE LEVEL. REPLACED BOTH EEL LIGHT LENS. COVERS ALSO MISSING FROM DR-4L LOWER AFT SIGN. LENS REPLACED ON LEFT SIDE AS WELL. A/C RETURNED TO NORMAL SERVICE. SUSPECT IMPACTS W/ GND EQUIP.
Part: LIGHT — INOPERATIVE (SEATS 3E & 22C) · airframe 46,143 hrs · 8,842 cycles
EMERGENCY LIGHT INOP AT 3E AND 22C. *S/D* REPLACED AFT LIGHT ASSY AT SEAT 3E. OP CHECKS GOOD. REPLACED LIGHT BULB AT SEAT 22C. OP CHECKS GOOD.
2005
Part: LIGHT — INOPERATIVE (CABIN) · airframe 41,069 hrs · 7,955 cycles
EEL LIGHT AT 18G AND 39G INOP. REPLACED EEL LIGHT.
Part: HOUSING — BROKEN (LAVATORY TOILET) · airframe 38,435 hrs · 7,511 cycles
MALFUNCTIONING LAVATORY. FWD LAV AT DOOR 3L WASTE COMING UP FROM TOILET BOWL IN FLIGHT AT APPROX 3000 FEET. BLOCKAGE ON THE WASTE LINE DOWNSTREAM TO THE WASTE TANK CAUSED ALL THE LAVS ASSOCIATED TO THE WASTE TANK TO BE INOPERABLE. WITH LAV 3L FLUSH VALVE HOUSING BROKEN, WASTE FOUND A PATH TO OVERFLOW. BLOCKAGE WAS SUBSEQUENTLY REMOVED AND DOOR 3L TOILET ASSEMBLY WAS REPLACED.
2004
Part: SURVIVAL KIT — MISINSTALLED (ESCAPE SLIDE)
SURVIVAL KIT PACKED IN INCORRECT LOCATION AND LOCATOR LIGHT BATTERY CORD WRAPPED AROUND THE BATTERY. SLIDE WAS PACKED INCORRECTLY AT OVERHAUL JAN 04, BUT NOT ORDERED FOR AN A/C UNTIL OCT 04. WHEN SLIDE INSTALLATION WAS ATTEMPTED, IT WAS REJECTED DUE TO BEING OVERSIZE. SLIDE WAS NOT INSTALLED ON A/C. SLIDE WAS REPACKED AND MADE SERVICEABLE.
2003
Part: LIGHT — MISSING (SEAT 1F) · airframe 33,276 hrs · 6,573 cycles
SEAT 1F OB SIDE EMERGENCY LIGHT HAS SECTION MISSING. REPLACED LIGHT.
Part: ADAPTER — CRACKED (NR 1 ENGINE) · airframe 32,257 hrs · 6,386 cycles
RETURN TO FIELD DUE TO NR 1 ENGINE OIL TEMP. INDICATED OVER TEMP. THE TUBE-TO-BOSS ADAPTER, WHICH SECURES THE 12TH STAGE AIR COOLING LINE FROM THE NR 3 BEARING BUFFER AIR COOLER WAS FOUND CRACKED. THIS FAILURE RESULTED IN LOSS OF 12TH STAGE COOLING AIR FROM THE BUFFER AIR COOLER TO THE NO. 3 BEARING COMPARTMENT. THIS IS A "FIRST-OF-KIND" FAILURE.
2002
Part: SKIN — DELAMINATED (NR 14 SLAT)
NR 14 SLAT T/E WEDGE DELAMINATED MAJOR REPAIR ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
Part: SKIN — DELAMINATED (NR 3 SLAT)
NR 3 SLAT T/E WEDGE DELAMINATED MAJOR REPAIR ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
Part: SKIN — DENTED · airframe 29,810 hrs · 5,912 cycles
FUSELAGE DENTED AT STATION 2108 RH SIDE, WL 192. MAJOR REPAIR ACCOMPLISHED. DOUBLER APPLIED TO DENTED AREA ON FUSELAGE, STATION 2108 RH SIDE, WL 192.
Part: WEDGE — DELAMINATED (#12 SLAT)
TRAILING EDGE WEDGE DELAMINATED, #12 SLAT MAJOR REPAIR ACCOMPLISHED. AD 2002-11-02 ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
Part: WEDGE — DELAMINATED (#2 SLAT)
T/E WEDGE DELAMINATED, #2 SLAT. MAJOR REPAIR ACCOMPLISHED. AD 2002-11-02 ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
Part: WEDGE — DELAMINATED (#13 SLAT)
DELAMINATED T/E WEDGE, #13 SLAT MAJOR REPAIR ACCOMPLISHED. AD 2002-11-02 ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
Part: WEDGE — DELAMINATED (#11 SLAT)
T/E WEDGE DELAMINATED, SLAT #11 MAJOR REPAIR ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
Part: WEDGE — DELAMINATED (L/E SLAT)
TRAILING EDGE SLAT DELAMINATED SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. CORE, WEDGE AND SKIN REBUILT.
2001
Part: RIVET — WRONG PART (FUSELAGE) · airframe 26,515 hrs · 5,280 cycles
THERE IS A PROTRUDING HEAD RIVET IN THE EXTRA CRITICAL AREA (REF RVSM). RIVET IS LOCATED LEFT SIDE OF FUSELAGE APPROXIMATELY 2 FEET FORWARD OF STATIC PORTS BELOW DOOR 2L. MAJOR REPAIR ACCOMPLISHED. REPLACED RIVET WITH ONE SIZE OVER FLUSH HEAD AND MICROSHAVED.
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 26,034 hrs · 5,180 cycles
STATION 246 RBL 26.06 CHORD CRACKED 2 PLACES UNDER WEB. MAJOR REPAIR ACCOMPLISHED. REPAIR NR 2 SPLICED IN NEW SECTION OF CHORD, RBL 50 TO LBL 21. NOTED CRACKING OF THE 141W8519-1 MID CHORD IS DUE TO THERMAL CONTRACTION THAT RESULTS IN HIGHER THAN EXPECTED IN-SERVICE LOADING OF THE DOUBLE DEPTH STATION 246 FLOORBEAM. PART IS BEING REPAIRED.
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 26,034 hrs · 5,180 cycles
STA 246 WEB CRACKED AT RBL 26.06 JUST OUTBOARD OF UPPER FASTENER COMMON TO MID-CHORD. MAJOR REPAIR: DAMAGE REMOVED AND DOUBLER INSTALLED. NOTED CRACKING OF THE 141W8518-17 WEB IS DUE TO THERMAL CONTRACTION THAT RESULTS IN HIGHER THAN EXPECTED IN-SERVICE LOADING OF THE DOUBLE DEPTH STATION 246 FLOORBEAM. PART IS BEING REPAIRED.
Part: SLIDE — CUT (R1 DOOR) · airframe 25,868 hrs · 5,148 cycles
DOOR 1 RT SLIDE/RAFT P/N 62771-118, S/N 0284 FOUND TO HAVE 5 CUTS IN INFLATABLE. CUTS FOUND DURING SHOP OVERHAUL OF THE UNIT. THERE WERE 3 CUTS IN TOP TUBE AND 2 IN BOTTOM TUBE ON RT SIDE OF SLIDE/RAFT ABOVE BOTTOM TUBE RELIEF VALVE. CUTS IN THE INFLATABLE APPEAR TO BE CAUSED BY A SNAP ON THE REBOARD LINE BEING PUSHED INTO THE BACK OF THE BOTTOM TUBE RELIEF VALVE CUTTING THE INFLATABLE MATERIAL. THIS HAPPENED WHEN THE UNIT WAS REPACKED.
Part: CONTROL UNIT — MALFUNCTIONED (RT FLAPERON) · airframe 25,015 hrs · 4,967 cycles
45 MINUTES OUT FROM JFK (JFK-LHR) EICAS MESSAGES FOR FLIGHT CONTROL SYSTEM AND FUEL FILTER. RETURN TO JFK. FUEL DUMPED. A FLIGHT CONTROL SYS EICAS STATUS MSG WAS CAUSED BY THE RT OUTBD FLAPERON MSG 2710303 PCU DOES NOT FOLLOW COMMAND. MAINT PERFORMED FIM TASK 27-11-817 WITH TEST PASS. RT OUT FLAPERON PCU WAS REPLACED 7/13/01. AIRPLANE HAS REPORTED NO FURTHER FLIGHT CONTROL PROBLEMS.
Part: CONTROL PANEL — OVERHEATED (CABIN) · airframe 24,580 hrs · 4,881 cycles
ELECTRICAL SMELL IN CABIN BY DOOR 2L. *S/D* THE TWO BACKLIGHTS FOR THE TOUCHSCREEN ON THE CACP AT DR 2L HAD FAILED. THE FAILURE CREATED AN OVERHEAT CONDITION AT THE LIGHT INSULATION. THE OVERHEAT OF THE INSULATION WAS THE SOURCE OF THE ODOR. THE CACP WAS DEACTIVATED UNTIL PART WAS REPLACED.
2000
Part: FLOORBEAM — CRACKED (FUSELAGE) · airframe 22,474 hrs · 4,494 cycles
STA 246 FORWARD STIFFENERS DAMAGED:TWO CRACKED IN THE RADIUS AT RBL 27.34 & LBL 7.88. TWO BUCKLED IN THE FREE FLANGE AT RBL 7.88 AND LBL 26.06. SUPPLEMENTAL DATA UPDATE, REPLACED STIFFENERS PER SRM 53-10-51.
Part: STRUCTURE — VIBRATION (FUSELAGE) · airframe 21,325 hrs · 4,278 cycles
EN ROUTE IAD-FRA, PRONOUNCED VIBRATION IN FLOOR AT DOOR 2R. VIBRATION WORSE IN CLIMB, DIMINISHED AT LEVEL OFF. AIRCRAFT RETURNED TO FIELD. *S/D* MAINTENANCE CHECKED AIR CONDITIONING RAM AIR DOORS AND FOUND CONDITION ACCEPTABLE. ALSO ENGINEERING CALLED FOR CHECK OF SLAT EXTENSION ARM DOOR AND FOUND NO DISCREPANCIES. AIRCRAFT RETURNED TO SERVICE WITH NOT FURTHER WRITE-UPS.
1999
Part: SEAL — FAILED (APU COMPRESSOR)
OUTBOUND CREW SMELLED OIL IN COCKPIT. PREVIOUS REPORT OF SMOKE AND SMELL IN CABIN AND COCKPIT ON FLIGHT 918-12. *S/D* APU (S/N 1059) (P/N 3800550-1) WAS REMOVED FROM A/C 2069 ON 4/23/99. APU HAD SUFFERED SEVERE ENGINE COMPRESSOR DAMAGE DUE TO SOFT (ICE) FOD. THE DAMAGE WAS EXTENSIVE. THE RESULTING EFFECT OF THE DAMAGE WAS LEAKAGE OF OIL PAST THE ENGINE COMPRESSOR SEAL ALLOWING OIL INTO THE BLEED AIR.
1997
Part: SUPPORT — BROKEN (RT WING)
ON WALKAROUND, FOUND FAIRING SUPPORT ROD BRACKET (115W2266-5) FOR RIGHT HAND TRAILING EDGE ASSEMBLY LOWER INBOARD FIXED FAIRING BROKEN. THE SUPPORT BEAM (115W2214-2) WAS ALSO DAMAGED. *S/D* ACCOMPLISHED INTERIM REPAIR UNTIL REPLACEMENT PARTS AVAILABLE FROM BOEING.
Part: BELLCRANK PIN — FAILED (2.5 BLEED VALVE)
RIGHT ENGINE OVER TEMPERATURE DURING REDUCED POWER TAKEOFF. AT LEVEL OFF, TRIED TO BRING POWER BACK BUT TEMPERATURE WOULD RISE AGAIN. *S/D* REPLACED NR 2 ENGINE. FOUND 2.5 BLEED VALVE BELLCRANK (P/N 51D125) WITH PIVOT PIN BROKEN (51D271). ENGINE SENT TO PRATT AND WHITNEY FOR REPAIR. CAMPAIGN INITIATED TO REPLACE ORIGINAL DESIGN 2.5 BLEED HARDWARE WITH IMPROVED DESIGN.
Part: CONNECTOR — CORRODED (DOOR 4 L)
DURING CRUISE, ALL CABIN EMERGENCY LIGHTS CAME ON EXCEPT LIGHTS AT DOOR 4L. NEW POWER SUPPLY AND BATTERY NO HELP. FOUND LOW VOLTAGE AT PIN 22 AT DM33407. SUSPECT FAULT IN WIRE BETWEEN D6222P AND DM33407. *S/D* REPLACED CORRODED CONNECTOR D6219P AND D6207J. ALSO, REPOSITIONED CONNECTOR TO MINIMIZE CONDENSATION IN FUTURE.
Part: SOLENOID — FAILED (EFSS)
ENGINE FIRE SHUT-OFF SWITCH SOLENOID ASSY RETURNED OF REPAIR WITH A REPORTED FAULT 'POPS SOLENOID CIRCUIT BREAKER'. DURING RECEIVING INSPECTION, THE OVERRIDE BUTTON WOULD NOT FULLY DEPRESS USING NORMAL FORCE. CONTINUITY TEST CONFIRMED THE SOLENOID HAD FAILED. BOEING NOTIFIED FOR FURTHER EVALUATION OF THE FAILURE.
Part: SLAT — CRACKED (NR 9 LE SLAT)
LEADING EDGE SLAT NR 9 (114W4160-8) CENTER COVER PANEL HAS TWO CRACKS, 2 INCH AND 8 INCH. INTERNALLY FOUND THREE ADDITIONAL CRACKS ON NOSE BEAM WEB 1 INCH TO 3 INCH IN LENGTH UNDER STIFFENERS BETWEEN OUTBOARD MAIN TRACK RIB ASSY AND O/B DEFLECTION CONTROL RIB ASSY. PRELIMINARY FINDINGS INDICATE CRACKING APPEARS TO BE THE RESULT OF HIGH CYCLE SONIC FATIGUE.
Part: P2/T2 PROBE — BLOCKED (NR 2 ENGINE)
ON TAKEOFF, NR 2 ENGINE DID NOT DEVELOP FULL TAKEOFF EPR. ENGINE RPM ALSO LOWER THAN TARGET. MAX EPR LIMIT FOR NUMBER 2 ENGINE WAS LOWER THAN NUMBER 1 ENGINE. ENGINE THRUST RETURNED TO NORMAL AFTER TAKEOFF AND REMAINED NORMAL. *S/D* MAINTENANCE REPLACED THE NUMBER 2 ENGINE P2/T2 PROBE. MANUFACTURER HAS TESTED PROBE FOR DE-ICE HEATER FUNCTION IN WIND TUNNEL. ADDITIONAL INSPECTION FOR FOREIGN OBJECT CONTAMINANTS USING N-RAY METHOD TO BE CONDUCTED. UNDER INVESTIGATION. ***8/5/97 UPDATE: PROBE PASSED ALL INSPECTIONS. NO DISCREPANCIES FOUND. SUSPECT TEMPORARY BLOCKAGE OF T2 AIR PASSAGE BASED ON ENGINE RESPONSE.***
Part: ARMING CABLE — BROKEN (CABIN DOOR 2L)
ESCAPE SLIDE AT DOOR 2 LEFT DROPPED ONTO FLOOR WITHOUT DEPLOYING PRIOR TO DEPARTURE. EPAS (EMERGENCY POWER ASSIST SYSTEM) SYSTEM FUNCTIONED NORMALLY. DOOR ASSIST BOTTLE WAS DEPLETED, READS ZERO PRESSURE. REPLACED SLIDE AND EPAS RESERVOIR. REPLACED CABLE PN 2603820-3. CAUSE OF CABLE FAILURE UNDER INVESTIGATION.
1996
Part: GENERATOR — MALFUNCTIONED (RIGHT)
DURING CLIMB, RIGHT GENERATOR OFF LIGHT ILLUMINATED. ATTEMPTED ONE RESET PER HANDBOOK, DID NOT RESET. STARTED APU AND CONTINUED.
Part: FUEL TANK — LEAKING (RT MAIN TANK)
FUEL LEAKING FROM RIGHT MAIN TANK INTO CENTER TANK. CENTER TANK AND FUEL IMBALANCE ADVISORY. TAKEOFF FUEL WAS IN BALANCE AND NO FUEL IN CENTER TANK. FUEL MOVING AT A RATE OF 100 POUNDS EVERY 6 TO 8 MINUTES.
Part: RETRACT MECH — OUT OF ADJUST (NR 7 LE FLAP)
AFTER TAKEOFF, NOTICED LOUD SUSTAINED VIBRATION IN CABIN FROM LEADING EDGE OF WING AFT INTO MID CABIN AREA. ALSO, FELT IN FLOOR OF COCKPIT. VIBRATION REMAINS AT ALL POWER SETTINGS. AIRCRAFT RETURNED TO FIELD. *S/D* ADJUSTED NR 7 SLAT PER AMM 27-81-00.
Part: SEAM — LEAKING (SLIDE)
SLIDE REMOVED FROM AIRCRAFT DUE TO INADVERTENT DEPLOYMENT. SLIDE HAS A SEAM LEAK AT THE LT CORNER OF THE SLIDE. REPAIRED SEAM LEAK, NON-STRUCTURAL.
1995
Part: TILT ACTUATOR — FAILED (RT MLG)
AFTER TAKEOFF RIGHT MLG DOOR WOULD NOT CLOSE, RETURNED TO FIELD. *S/D* FOUND RT MLG TRUCK TILT ACTUATOR BYPASSING. REPLACED SAME, SWUNG GEAR OPERATES NORMAL.